In-Cabinet Distributed I/O

Catalogs > Automation Systems Catalog > I/O > In-Cabinet Distributed I/O > 1734 POINT I/O

1734 POINT I/O

Introduction Product Design Environmentals and Certifications I/O Adapter and Communication Interface Modules 1734D POINTBlock I/O Modules
Digital I/O Modules Analog I/O Modules Specialty I/O Modules Power Supplies Terminal Base Assemblies and RTBs
Specialty I/O Modules

Counter Modules

The POINT I/O Counter/Encoder modules return the count or frequency in the form of a 24-bit binary number (0-16,777,215) expressed in a 32-bit word. Each counter has a user-selectable preset and rollover value associated with it. The counter mode only accepts single-phase inputs. The encoder mode only accepts 2-phase quadrature inputs.

Cat. No. Counters Voltage Category Compare Windows Output Groups Input Frequency, Max. Output Delay Time, Off to On On-State Current, Min. PointBus Current (mA) Power Dissipation, Max. Terminal Base Unit
1734-IJ 1 5V DC 1.0 MHz counter and encoder X1 configurations (no filter)
500 kHz encoder X2 configuration (no filter)
250 kHz encoder X4 configuration (no filter)
³5 mA 160 mA 1.1 W @ rated load 1734-TB or 1734-TBS
1734-IK 24V DC (15V DC…24V DC) 1.5 W @ rated load 1734-TB or 1734-TBS
1734-VHSC5 1 5V DC 4 1 group of 2 25 ms (load dependent)¬  180 mA 1.5 W @ rated load 1734-TB or 1734-TBS
1734-VHSC24 24V DC (15V DC…24V DC) 1.9 W @ rated load 1734-TB or 1734-TBS
¬ Off to On delay is time from a valid output “on” signal to output energization.

Serial I/O Modules

Cat. No. Inputs/Outputs Description PointBus Current (mA) External DC Supply Current, Nom. Power Dissipation, Max. Terminal Base Unit
1734-SSI 1  Encoder channel The Synchronous Serial Interface Absolute Encoder Module collects serial data from industrial absolute-position encoding sensors that use standard SSI protocol, including linear, rotary, and optical distance measuring devices. The module is inserted into a POINT I/O terminal base that provides common power, communications, and wiring connections for the SSI sensors. The module converts a serial data stream from an SSI sensor into absolute position data readable as a 32-hexadecimal value. Gray or Binary-code capable with gray to binary conversion, increasing or decreasing SSI count indication, 2 SSI word comparator values, and SSI word latching with I1 input. 110 mA 10…28V DC,
0.75 A max
0.94 W 1734-TB, 1734-TBS
1734-232ASC 1 Serial Interface channel The 1734-232ASC and 1734-485ASC serial-interface modules offer a serial-link communication interface solution for peripheral products with RS-232 (use the 1734-232ASC), RS-485, and RS-422 ports (use the 1734-485ASC). These modules allow a device with serial-interface output (i.e., bar code readers) to communicate up to 128 bytes of ASCII data onto any network supported by POINT I/O. Each module is a single-channel, full-duplex interface and is rated for up to 38.4k baud. LED indicators on the modules offer diagnostics for the module, POINTBus backplane, and transmit/receive status indication. 75 mA 10…28V DC
1.0 A max
0.75 W @ 28.8V DC 1734-TB or 1734-TBS
1734-485ASC 1 Serial Interface channel 75 mA 10…28V DC
1.0 A max
0.75 W @ 28.8V DC 1734-TB or 1734-TBS
 

Address Reserve Module

Cat. No. Description PointBus Current (mA) Power Dissipation, Max. Terminal Base Unit
1734-ARM The Address Reserve Module is a single-slot 12 mm wide smart slot filler. Use the module to retain a node address for later insertion of any future option. 75 max @ 5V DC 0.375 W @ 5V DC 1734-TB, 1734-TBS