1792 ArmorBlock MaXum I/O
|
|
|
ArmorBlock MaXum I/O
The 1792 ArmorBlock MaXum™ I/O family features space-saving, sealed-housing blocks suitable for On-Machine™ mounting. ArmorBlock MaXum I/O takes advantage of the KwikLink™ flat media system for DeviceNet™ communication. Up to sixteen 24V DC points can be addressed per DeviceNet node. Local control is accomplished through DeviceLogix™ Smart Component Technology.
Benefits
- Sealed housing rated for IP67, and NEMA 4X and 6P eliminate enclosure costs.
- Low installation cost and easy to replace without rewiring, because industry-standard mini connectors are used for connection to the DeviceNet network and output-circuit power supply; and M12 micro connectors are used for connection to each sensor or actuator.
- Point-level diagnostics simplify troubleshooting.
- Only active device that connects directly to the DeviceNet KwikLink™ flat media system.
- Removal and Insertion Under Power (RIUP) makes it possible to replace a module without impacting the network operation.
- Isolated auxiliary power maintains power to the outputs if main power fails so that you can have the option of holding outputs in their last state.
- Outputs electronically protected from failing with option to auto-restart or latch off.
- Complies with Open DeviceNet Vendor Association, Inc. (ODVA) conformance test software.
- DeviceLogix™ Smart Component Technology lets you control outputs and manage status information locally, within the block.
Product Design
An ArmorBlock MaXum I/O block contains digital I/O circuits, a built-in power supply, and a built-in DeviceNet I/O adapter. I/O blocks are available in sizes of 2, 4, 8, and 16 I/O. The DeviceNet network supplies power to the inputs and attached sensors. Electronic fusing provides protection for output load devices and easy resetting.
ArmorBlock MaXum I/O blocks are designed for back-panel or on-machine mounting. Blocks can be mounted vertically or horizontally. Enclosure costs are eliminated because each block is packaged in a sealed housing rated for IP67 and NEMA 4X and 6P. I/O terminations are M12 DC micro quick-disconnect terminations.
1792 ArmorBlock MaXum
|
ArmorBlock MaXum I/O blocks have a compact style with a low profile. ArmorBlock MaXum blocks are packaged in a sealed housing rated for IP67 and NEMA 4X and 6P. Each I/O block requires a separate base for connection to a DeviceNet trunk or drop cable, using either the KwikLink flat media system or standard round media.
1792 ArmorBlock High-Current
|
ArmorBlock High-Current I/O blocks include solid-state outputs that can accommodate up to 40 A maximum per module. These blocks are packaged in a housing rated for IP52 and NEMA Type 5 and Type 12. They do not require a separate base.
Communication
A 1792 ArmorBlock MaXum I/O block has a built-in DeviceNet I/O adapter port that interfaces the I/O with a DeviceNet link to communicate with a scanner port for a programmable controller processor. DeviceNet I/O update period can be shortened by transferring I/O values only when a change-of-state has occurred.
Specifications
General Specifications
| ArmorBlock MaXum | High-Current ArmorBlock | |
| Enclosure Type Rating | IP67, NEMA 4X and 6P | IP52, NEMA Type 5 and Type 12 |
| Mounting Type | On-Machine | Panel |
| Operating Temperature | -25…60 °C (-13…140 °F) | -20…60 °C (-4…140 °F) |
| Nonoperating Temperature | -25…80 °C (-13…176 °F) | -40…85 °C (-40…185 °F) |
| Relative Humidity | 5…95% noncondensing | 5…95% noncondensing |
| Operating Shock | 30 g peak acceleration, 11(±1) ms pulse width | |
| Nonoperating Shock | 50 g peak acceleration, 11(±1) ms pulse width | |
| Vibration | 10 g at 10…500 Hz | |
| Certifications⋆ | CSA, CE, C-Tick, ODVA | CSA, CE, C-Tick, ODVA |
| ⋆ When product is marked. See the Product Certification link at www.ab.com for Declarations of Conformity, Certificates, and other certification details. | ||
Dimensions and Weights
| Cat. No. | Dimensions (HxWxD), Approx. | Weight |
| 8-connector I/O blocks | 48.26 x 68.6 x 174 mm⋆ (1.9 x 2.7 x 6.85 in⋆ ) |
0.6 kg (1.3 lb) |
| 4-connector I/O blocks | 48.26 x 68.6 x 120 mm⋆ (1.9 x 2.7 x 4.7 in⋆ ) |
0.5 kg (1.1 lb) |
| 2-connector block | 48.26 x 68.6 x 120 mm⋆ (1.9 x 2.7 x 4.7 in⋆ ) |
0.5 kg (1.1 lb) |
| High-Current block | 67 x 197 x 78 mm (2.7 x 7.8 x 3.1 in) |
0.7 kg (1.5 lb) |
| Cable bases | 0.2 kg (0.5 lb) |
|
| ⋆ Assembled to base. | ||
Typical Configurations
ArmorBlock MaXum Configuration with Standard DeviceNet Round Trunk Cable
|
ArmorBlock MaXum Configuration with Flat DeviceNet Trunk Cable
|
ArmorBlock MaXum Digital I/O
Digital Input Blocks
| Cat. No. | Number of Inputs | Number of Connectors | Diagnostics | Voltage, On-State Input, Nom. | Voltage Range, On-State Input | Current, Off-State Input, Max. | DeviceNet Current (mA) |
| 1792D-16BVT0D | 16 current sinking/current sourcing | 8 | Connector-level | 24V DC | 10V DC…25V DC | 1.5 mA | 700 mA⋆ |
| 1792D-16BVT0CD | Point-level | 650 mA⋆ | |||||
| 1792D-8BVT0D | 8 current sinking/current sourcing | 4 | Connector-level | 470 mA | |||
| 1792D-8BV0D | 8 | Point-level | 470 mA | ||||
| 1792D-4BV0D | 4 current sinking/current sourcing | 4 | Point-level | 220 mA§ | |||
| 1792D-2BV0D | 2 current sinking/current sourcing | 2 | Point-level | 130 mA♣ | |||
| ⋆ DeviceNet Current specified with 16 sensors drawing 25 mA @ 24V DC. DeviceNet Current specified with 8 sensors drawing 25 mA @ 24V DC. § DeviceNet Current specified with 4 sensors drawing 25 mA @ 24V DC. ♣ DeviceNet Current specified with 2 sensors drawing 25 mA @ 24V DC. |
|||||||
Digital Output Blocks
| Cat. No. | Number of Outputs | Number of Connectors | Diagnostics | Voltage, On-State Output, Nom. | Voltage Range, On-State Output | Current, On-State Output, Max. | DeviceNet Current (mA) |
| 1792D-0B4D | 4 current sourcing | 4 | Point-level | 24V DC | 10V DC…30V DC | 2.0 A | 80 mA |
| 1792D-0B8D | 8 current sourcing | 8 | Point-level | 1.0 A | 80 mA | ||
| 1792D-0VT16E | 16 current sinking | 8 | None | 0.3 A | 150 mA |
Digital Combination Blocks
| Cat. No. | Inputs | Outputs | DeviceNet Current (mA) | ||||||
| Number of Inputs | Number of Connections | Diagnostics | Operating Voltage | Current, Off-State Input, Max. | Number of Outputs | Operating Voltage | Current, On-State Output, Max. | ||
| 1792D-12BVT4D | 12 current sinking/current sourcing | 8 | Connector-level | 10V DC…25V DC | 1.5 mA | 4 current sourcing | 10V DC…30V DC | 0.5 A | 570 mA§ |
| 1792D-12BT4PE | 12 current sinking/current sourcing | Connector-level | 2.0 A | 1.6 A⋆ 2.0 A | |||||
| 1792D-8BVT8D | 8 current sinking/current sourcing | 8 | Connector-level | 8 current sourcing | 0.5 A | 470 mA♣ | |||
| 1792D-8BVT8CD | 8 | Point-level | 0.5 A | 470 mA♣ | |||||
| 1792D-8BT8PE | 8 current sinking/current sourcing | 8 | Connector-level | 0.5 A | 1.4 A | ||||
| 1792D-4BVT4D | 4 current sinking/current sourcing | 4 | Connector-level | 4 current sourcing | 1.0 A | 220 mA∆ | |||
| 1792D-4BV4D | 8 | Point-level | 1.0 A | 220 mA♦ | |||||
| 1792D-2BVA2D | 2 current sinking/current sourcing | 4 | Connector-level | 2 current sourcing | 1.0 A | 130 mA♠ | |||
| 1792D-8BIO8E | 8 current sinking | 8 | Block-level | 8 current sourcing (powered by network) | 0.3 A | 470 mA♣ | |||
| ⋆ 175 mA max (no sensors), up to 1.6 A (12 sensors @ 50 mA per sensor) Refer to the graphs in the DeviceNet Power Supply Requirements section of the ArmorBlock MaXum I/O and ArmorBlock I/O Selection Guide, pub. no. 1792-SG001. 175 mA max (no sensors), up to 1.4 A (8 sensors @ 50 mA per sensor) Refer to the graphs in the DeviceNet Power Supply Requirements section of the ArmorBlock MaXum I/O and ArmorBlock I/O Selection Guide, pub. no. 1792-SG001. § DeviceNet Current specified with 12 sensors drawing 25 mA @ 24V DC. ♣ DeviceNet Current specified with 8 sensors drawing 25 mA at 24V DC. ∆ DeviceNet Current specified with 4 sensors drawing 25 mA @ 24V DC. ♦ DeviceNet Current specified with 4 sensors drawing 25 mA at 24V DC. ♠ DeviceNet Current specified with 2 sensors drawing 25 mA @ 24V DC. |
|||||||||
ArmorBlock High-Current I/O
This 8 input/8output ArmorBlock module is capable of driving 5…10 amps per solid-state output, eliminating the need for interposing relays. These modules communicate over DeviceNet using polled, cyclic or change-of-state messaging. Local control is accomplished through DeviceLogix™ Smart Component Technology.
- 5…10 amp solid-state outputs
- AutoBaud
- Selectable off-to-on or on-to-off input filters
- Inputs are configured for PNP (sourcing) or NPN (sinking) devices
- Point level diagnostics: output no load and short circuit/overcurrent
- Auxiliary power detection
- DeviceLogix™ Smart Component Technology
| Cat. No. | Inputs | Outputs | Number of Connectors | Current, Off-State Input, Max. | Current Per Output, Max. | DeviceNet Current (mA) | Diagnostics | ||
| Number of Inputs | Operating Voltage Range | Number of Outputs | Operating Voltage Range | ||||||
| 1792D-88HC | 8 current sinking/current sourcing⋆ | 8V DC…30V DC | 8 current sourcing⋆ | 10V DC…30V DC | 1 | 1.2 mA | 6 outputs at 5 A each | 100 mA | Point-level |
| 2 outputs at 10 A each | |||||||||
| 40 A total | |||||||||
| 1792D-88HCCON | Components for a user-fabricated assembly for field connections. Includes connector, hood and pins. | ||||||||
| 1792D-88HCCBL | Pre-made cable assembly for field connections. | ||||||||
| ⋆ 2 sets of 4. |
|||||||||
ArmorBlock MaXum Cable Bases
Each ArmorBlock MaXum I/O block, except for the 1792D-88HC high current block, requires a separate cable base.
| Cat. No. | Description |
| 1792D-CB12 | ArmorBlock MaXum I/O Cable Base with Micro (M12) connectors. Accepts standard drop cables from round or flat media taps. |
| 1792D-CB12JP | ArmorBlock MaXum I/O Cable Base with Micro (M12) connectors and jumpered DeviceNet power |
| 1792D-CBFM | ArmorBlock MaXum I/O Cable Base for KwikLink flat media |
| 1792D-CB18 | ArmorBlock MaXum I/O Cable Base with Mini connectors and passthrough for DeviceNet |
| 1792D-CB18JP | ArmorBlock MaXum I/O Cable Base with Mini connectors and jumpered DeviceNet power |
| 1792D-CB18P | ArmorBlock MaXum I/O Cable Base with Mini connectors, DeviceNet pass-through, and auxiliary power input connection |
| 1792D-CB18PT | ArmorBlock MaXum I/O Cable Base with Mini round connectors, DeviceNet passthrough, and auxiliary power input and output connections⋆ |
| 1792D-CB23 | ArmorBlock MaXum I/O Cable Base with 17-Pin M23 Connectors |
| 1792D-KPLT | KEMPF Interface Plate |
| ⋆ Compatible only with MaXum blocks with a maximum of 4 I/O connectors. | |
Mating Cables
The mating cables shown represent straight PVC models. For additional configurations, materials, and specifications, consult the On-Machine Connectivity Products Catalog.
| Digital Input or Output Blocks Mating Cables | ||||
| ArmorBlock Cat. No. | End Device per Connector | Recommended Patchcord (double-ended) |
Recommended Male Cordset (single-ended) |
Recommended Field Attachable Connector |
| 1792D-0B4D 1792D-0B8D 1792D-2BV0D 1792D-4BV0D 1792D-8BV0D |
(1) DC Micro | 889D-F4ACDM-* | 889D-M4AC- | 871A-TS4-DM |
| (1) Pico 3-Pin | 889P-F3ABDM4-* | |||
| (1) Pico 4-Pin | 889P-F4ABDM-* | |||
| 1792D-0BVT16E 1792D-16BVT0D 1792D-8BVT0D |
(2) DC Micro | 879D-F4ACDM-* | 879D-C3ACD4M- | 871A-VS4-DM |
| (2) Pico 3-Pin | 879PZ-F3ABDM4-* | |||
| (2) Pico 4-Pin | 879PZ-F4ABDM-* | |||
| (1) DC Micro | 889D-F4ACDM-* | 889D-M4AC- | 871A-TS4-DM | |
| (1) Pico 3-Pin | 889P-F3ABDM4-* | |||
| (1) Pico 4-Pin | 889P-F4ABDM-* | |||
| 1792D-16BVT0CD | (2) DC Micro | 879D-F4ACD5M-* | 879D-F4D5M + (2) 889D-M4AC- |
871A-VS5-DM |
| (2) Pico 3-Pin | 879D-F4D5M + (2) 889P-F3ABDM4-* |
|||
| (2) Pico 4-Pin | 879D-F4D5M + (2) 889P-F4ABDM-* |
|||
| (1) DC Micro | 889D-F4ACDM-* | 889D-M4AC- | 871A-TS4-DM | |
| (1) Pico 3-Pin | 889P-F3ABDM4-* | |||
| (1) Pico 4-Pin | 889P-F4ABDM-* | |||
| * = length in meters (1, 2, 3, 5, and 10 standard). = length in meters (2, 5, and 10 standard). |
||||
| Digital Combination Blocks Mating Cables | ||||
| ArmorBlock Cat. No. | End Device per Connector | Recommended Patchcord (double-ended) |
Recommended Male Cordset (single-ended) |
Recommended Field Attachable Connector |
| 1792D-2BVA2D 1792D-4BV4D |
(1) DC Micro | 889D-F4ACDM-* | 889D-M4AC- | 871A-TS4-DM |
| (1) Pico 3-Pin | 889P-F3ABDM4-* | |||
| (1) Pico 4-Pin | 889P-F4ABDM-* | |||
| 1792D-12BVT4D 1792D-4BVT4D 1792D-8BVT8D 1792D-8BIO8E |
(2) DC Micro | 879D-F4ACDM-* | 879D-C3ACD4M- | 871A-VS4-DM |
| (2) Pico 3-Pin | 879PZ-F3ABDM4-* | |||
| (2) Pico 4-Pin | 879PZ-F4ABDM-* | |||
| (1) DC Micro | 889D-F4ACDM-* | 889D-M4AC- | 871A-TS4-DM | |
| (1) Pico 3-Pin | 889P-F3ABDM4-* | |||
| (1) Pico 4-Pin | 889P-F4ABDM-* | |||
| 1792D-12BT4PE 1792D-8BT8PE 1792D-8BVT8CD |
(2) DC Micro | 879D-F4ACD5M-* | 879D-F4D5M + (2) 889D-M4AC- |
871A-VS5-DM |
| (2) Pico 3-Pin | 879D-F4D5M + (2) 889PF3ABDM4-* |
|||
| (2) Pico 4-Pin | 879D-F4D5M + (2) 889PF4ABDM-* |
|||
| (1) DC Micro | 889D-F4ACDM-* | 889D-M4AC- | 871A-TS4-DM | |
| (1) Pico 3-Pin | 889P-F3ABDM4-* | |||
| (1) Pico 4-Pin | 889P-F4ABDM-* | |||
| * = length in meters (1, 2, 3, 5, and 10 standard). = length in meters (2, 5, and 10 standard). |
||||
| ArmorBlock MaXum Network Mating Cables | ||||
| ArmorBlock Cat. No. | Network Connector Type | Flat Media | Thick Round | Thin Round |
| 1792D-CB12 1792D-CB12JP |
DeviceNet | 1485K-P§F5-R5 | 1485R-P§M5-R5 | 1485R-P§R5-D5 |
| 1792D-CB18 1792D-CB18JP |
DeviceNet | 1485K-P§F5-N5 | 1485R-P§N5-M5 | 1485R-P§D5-N5 |
| 1792D-CB18P 1792D-CB18PT |
DeviceNet | 1485K-P§F5-N5 | 1485R-P§N5-M5 | 1485R-P§D5-N5 1485R-P§M5-R5 |
| 1792D-CBFM | DeviceNet | 1485C-P1E* 1485C-P1G* 1485C-P1K* |
— | — |
| * = length in meters (75, 200, or 420). § = length in meters (1, 2, 3, 4, 5, and 6 standard). |
||||
| ArmorBlock MaXum Auxiliary Power Mating Cables | |||
| ArmorBlock Cat. No. | Flat Media | Round Media | |
| Auxiliary Power Flat Media Connection | Cordset (single-ended) | Patchcord (double-ended) | |
| 1792D-CB12 | 889D-F2ACDM-K§ | Cordset: 889D-F4AC- Patchcord: 889D-F2AEN4M-D§ |
Cordset: 889D-F4AC- Patchcord: 889D-F4ACDM-§ |
| 1792D-CB18 1792D-CB18P 1792D-CB18PT |
1485T-P1E4-C§-N4 | 889N-F4AFC-µF | 889N-F4AFNM-§ |
| 1792D-CB12JP 1792D-CB18JP |
Internally jumpered from network power | Internally jumpered from network power | Internally jumpered from network power |
| 1792D-CBFM | 1485C-P1L* | — | — |
| * = length in meters (75, 200, or 420). = length in meters (2, 5, and 10 standard). § = length in meters (1, 2, 3, 4, 5, and 6 standard). µ = length in feet (6, 12, and 20 standard). |
|||