1792 ArmorBlock MaXum I/O

Product Overview
  
Click to enlarge - 1792D_ArmorBlk_Bevel_4C

ArmorBlock MaXum I/O

The 1792 ArmorBlock MaXum™ I/O family features space-saving, sealed-housing blocks suitable for On-Machine™ mounting. ArmorBlock MaXum I/O takes advantage of the KwikLink™ flat media system for DeviceNet™ communication. Up to sixteen 24V DC points can be addressed per DeviceNet node. Local control is accomplished through DeviceLogix™ Smart Component Technology.

Benefits


Product Design

An ArmorBlock MaXum I/O block contains digital I/O circuits, a built-in power supply, and a built-in DeviceNet I/O adapter. I/O blocks are available in sizes of 2, 4, 8, and 16 I/O. The DeviceNet network supplies power to the inputs and attached sensors. Electronic fusing provides protection for output load devices and easy resetting.

ArmorBlock MaXum I/O blocks are designed for back-panel or on-machine mounting. Blocks can be mounted vertically or horizontally. Enclosure costs are eliminated because each block is packaged in a sealed housing rated for IP67 and NEMA 4X and 6P. I/O terminations are M12 DC micro quick-disconnect terminations.


1792 ArmorBlock MaXum

Click to enlarge - 1792DMaXuminbase_BW


ArmorBlock MaXum I/O blocks have a compact style with a low profile. ArmorBlock MaXum blocks are packaged in a sealed housing rated for IP67 and NEMA 4X and 6P. Each I/O block requires a separate base for connection to a DeviceNet trunk or drop cable, using either the KwikLink flat media system or standard round media.

1792 ArmorBlock High-Current

Click to enlarge - 1792D-HC88HiCurrent_BW


ArmorBlock High-Current I/O blocks include solid-state outputs that can accommodate up to 40 A maximum per module. These blocks are packaged in a housing rated for IP52 and NEMA Type 5 and Type 12. They do not require a separate base.

Communication

A 1792 ArmorBlock MaXum I/O block has a built-in DeviceNet I/O adapter port that interfaces the I/O with a DeviceNet link to communicate with a scanner port for a programmable controller processor. DeviceNet I/O update period can be shortened by transferring I/O values only when a change-of-state has occurred.

Specifications

General Specifications

  ArmorBlock MaXum High-Current ArmorBlock
Enclosure Type Rating IP67, NEMA 4X and 6P IP52, NEMA Type 5 and Type 12
Mounting Type On-Machine Panel
Operating Temperature -25…60 °C (-13…140 °F) -20…60 °C (-4…140 °F)
Nonoperating Temperature -25…80 °C (-13…176 °F) -40…85 °C (-40…185 °F)
Relative Humidity 5…95% noncondensing 5…95% noncondensing
Operating Shock 30 g peak acceleration, 11(±1) ms pulse width
Nonoperating Shock 50 g peak acceleration, 11(±1) ms pulse width
Vibration 10 g at 10…500 Hz
Certifications⋆  CSA, CE, C-Tick, ODVA CSA, CE, C-Tick, ODVA
  
⋆ When product is marked. See the Product Certification link at www.ab.com for Declarations of Conformity, Certificates, and other certification details.

Dimensions and Weights

Cat. No. Dimensions (HxWxD), Approx. Weight
8-connector I/O blocks 48.26 x 68.6 x 174 mm⋆ 
(1.9 x 2.7 x 6.85 in⋆ )
0.6 kg
(1.3 lb)
4-connector I/O blocks 48.26 x 68.6 x 120 mm⋆ 
(1.9 x 2.7 x 4.7 in⋆ )
0.5 kg
(1.1 lb)
2-connector block 48.26 x 68.6 x 120 mm⋆ 
(1.9 x 2.7 x 4.7 in⋆ )
0.5 kg
(1.1 lb)
High-Current block 67 x 197 x 78 mm
(2.7 x 7.8 x 3.1 in)
0.7 kg
(1.5 lb)
Cable bases   0.2 kg
(0.5 lb)
⋆ Assembled to base.

Typical Configurations

ArmorBlock MaXum Configuration with Standard DeviceNet Round Trunk Cable

Click to enlarge - 1792DMaXumonDnetRnd_4C


ArmorBlock MaXum Configuration with Flat DeviceNet Trunk Cable

Click to enlarge - 1792DMaXumonDnetFlt_4C

ArmorBlock MaXum Digital I/O

Digital Input Blocks

Cat. No. Number of Inputs Number of Connectors Diagnostics Voltage, On-State Input, Nom. Voltage Range, On-State Input Current, Off-State Input, Max. DeviceNet Current (mA)
1792D-16BVT0D 16  current sinking/current sourcing 8 Connector-level 24V DC 10V DC…25V DC 1.5 mA 700 mA⋆ 
1792D-16BVT0CD Point-level 650 mA⋆ 
1792D-8BVT0D 8  current sinking/current sourcing 4 Connector-level 470 mA‡ 
1792D-8BV0D 8 Point-level 470 mA‡ 
1792D-4BV0D 4  current sinking/current sourcing 4 Point-level 220 mA§ 
1792D-2BV0D 2  current sinking/current sourcing 2 Point-level 130 mA♣ 
⋆ DeviceNet Current specified with 16 sensors drawing 25 mA @ 24V DC.
‡ DeviceNet Current specified with 8 sensors drawing 25 mA @ 24V DC.
§ DeviceNet Current specified with 4 sensors drawing 25 mA @ 24V DC.
♣ DeviceNet Current specified with 2 sensors drawing 25 mA @ 24V DC.

Digital Output Blocks

Cat. No. Number of Outputs Number of Connectors Diagnostics Voltage, On-State Output, Nom. Voltage Range, On-State Output Current, On-State Output, Max. DeviceNet Current (mA)
1792D-0B4D 4  current sourcing 4 Point-level 24V DC 10V DC…30V DC 2.0 A 80 mA
1792D-0B8D 8  current sourcing 8 Point-level 1.0 A 80 mA
1792D-0VT16E 16  current sinking 8 None 0.3 A 150 mA

Digital Combination Blocks

Cat. No. Inputs Outputs DeviceNet Current (mA)
Number of Inputs Number of Connections Diagnostics Operating Voltage Current, Off-State Input, Max. Number of Outputs Operating Voltage Current, On-State Output, Max.
1792D-12BVT4D 12  current sinking/current sourcing 8 Connector-level 10V DC…25V DC 1.5 mA 4  current sourcing 10V DC…30V DC 0.5 A 570 mA§ 
1792D-12BT4PE 12  current sinking/current sourcing Connector-level 2.0 A 1.6 A⋆ 2.0 A
1792D-8BVT8D 8  current sinking/current sourcing 8 Connector-level 8  current sourcing 0.5 A 470 mA♣ 
1792D-8BVT8CD 8 Point-level 0.5 A 470 mA♣ 
1792D-8BT8PE current sinking/current sourcing 8 Connector-level 0.5 A 1.4 A‡ 
1792D-4BVT4D 4  current sinking/current sourcing 4 Connector-level 4  current sourcing 1.0 A 220 mA∆ 
1792D-4BV4D 8 Point-level 1.0 A 220 mA♦ 
1792D-2BVA2D 2  current sinking/current sourcing 4 Connector-level 2  current sourcing 1.0 A 130 mA♠ 
1792D-8BIO8E 8  current sinking 8 Block-level 8  current sourcing (powered by network) 0.3 A 470 mA♣ 
⋆ 175 mA max (no sensors), up to 1.6 A (12 sensors @ 50 mA per sensor) Refer to the graphs in the DeviceNet Power Supply Requirements section of the ArmorBlock MaXum I/O and ArmorBlock I/O Selection Guide, pub. no. 1792-SG001.
‡ 175 mA max (no sensors), up to 1.4 A (8 sensors @ 50 mA per sensor) Refer to the graphs in the DeviceNet Power Supply Requirements section of the ArmorBlock MaXum I/O and ArmorBlock I/O Selection Guide, pub. no. 1792-SG001.
§ DeviceNet Current specified with 12 sensors drawing 25 mA @ 24V DC.
♣ DeviceNet Current specified with 8 sensors drawing 25 mA at 24V DC.
∆ DeviceNet Current specified with 4 sensors drawing 25 mA @ 24V DC.
♦ DeviceNet Current specified with 4 sensors drawing 25 mA at 24V DC.
♠ DeviceNet Current specified with 2 sensors drawing 25 mA @ 24V DC.

ArmorBlock High-Current I/O

This 8 input/8output ArmorBlock module is capable of driving 5…10 amps per solid-state output, eliminating the need for interposing relays. These modules communicate over DeviceNet using polled, cyclic or change-of-state messaging. Local control is accomplished through DeviceLogix™ Smart Component Technology.


Cat. No. Inputs Outputs Number of Connectors Current, Off-State Input, Max. Current Per Output, Max. DeviceNet Current (mA) Diagnostics
Number of Inputs Operating Voltage Range Number of Outputs Operating Voltage Range
1792D-88HC 8  current sinking/current sourcing⋆  8V DC…30V DC 8  current sourcing⋆  10V DC…30V DC 1 1.2 mA 6 outputs at 5 A each 100 mA Point-level
2 outputs at 10 A each
40 A total
1792D-88HCCON Components for a user-fabricated assembly for field connections. Includes connector, hood and pins.
1792D-88HCCBL Pre-made cable assembly for field connections.
⋆ 2 sets of 4.

ArmorBlock MaXum Cable Bases

Each ArmorBlock MaXum I/O block, except for the 1792D-88HC high current block, requires a separate cable base.

Cat. No. Description
1792D-CB12 ArmorBlock MaXum I/O Cable Base with Micro (M12) connectors. Accepts standard drop cables from round or flat media taps.
1792D-CB12JP ArmorBlock MaXum I/O Cable Base with Micro (M12) connectors and jumpered DeviceNet power
1792D-CBFM ArmorBlock MaXum I/O Cable Base for KwikLink flat media
1792D-CB18 ArmorBlock MaXum I/O Cable Base with Mini connectors and passthrough for DeviceNet
1792D-CB18JP ArmorBlock MaXum I/O Cable Base with Mini connectors and jumpered DeviceNet power
1792D-CB18P ArmorBlock MaXum I/O Cable Base with Mini connectors, DeviceNet pass-through, and auxiliary power input connection
1792D-CB18PT ArmorBlock MaXum I/O Cable Base with Mini round connectors, DeviceNet passthrough, and auxiliary power input and output connections⋆ 
1792D-CB23 ArmorBlock MaXum I/O Cable Base with 17-Pin M23 Connectors
1792D-KPLT KEMPF Interface Plate
⋆ Compatible only with MaXum blocks with a maximum of 4 I/O connectors.

Mating Cables

The mating cables shown represent straight PVC models. For additional configurations, materials, and specifications, consult the On-Machine Connectivity Products Catalog.

Digital Input or Output Blocks Mating Cables
ArmorBlock Cat. No. End Device per Connector Recommended Patchcord
(double-ended)
Recommended Male Cordset
(single-ended)
Recommended Field Attachable Connector
1792D-0B4D
1792D-0B8D
1792D-2BV0D
1792D-4BV0D
1792D-8BV0D
(1) DC Micro 889D-F4ACDM-* 889D-M4AC-‡ 871A-TS4-DM
(1) Pico 3-Pin 889P-F3ABDM4-*
(1) Pico 4-Pin 889P-F4ABDM-*
1792D-0BVT16E
1792D-16BVT0D
1792D-8BVT0D
(2) DC Micro 879D-F4ACDM-* 879D-C3ACD4M-‡ 871A-VS4-DM
(2) Pico 3-Pin 879PZ-F3ABDM4-*
(2) Pico 4-Pin 879PZ-F4ABDM-*
(1) DC Micro 889D-F4ACDM-* 889D-M4AC-‡ 871A-TS4-DM
(1) Pico 3-Pin 889P-F3ABDM4-*
(1) Pico 4-Pin 889P-F4ABDM-*
1792D-16BVT0CD (2) DC Micro 879D-F4ACD5M-* 879D-F4D5M + (2)
889D-M4AC-‡
871A-VS5-DM
(2) Pico 3-Pin 879D-F4D5M + (2)
889P-F3ABDM4-*
(2) Pico 4-Pin 879D-F4D5M + (2)
889P-F4ABDM-*
(1) DC Micro 889D-F4ACDM-* 889D-M4AC-‡ 871A-TS4-DM
(1) Pico 3-Pin 889P-F3ABDM4-*
(1) Pico 4-Pin 889P-F4ABDM-*
* = length in meters (1, 2, 3, 5, and 10 standard).
‡ = length in meters (2, 5, and 10 standard).


Digital Combination Blocks Mating Cables
ArmorBlock Cat. No. End Device per Connector Recommended Patchcord
(double-ended)
Recommended Male Cordset
(single-ended)
Recommended Field Attachable Connector
1792D-2BVA2D
1792D-4BV4D
(1) DC Micro 889D-F4ACDM-* 889D-M4AC-‡ 871A-TS4-DM
(1) Pico 3-Pin 889P-F3ABDM4-*
(1) Pico 4-Pin 889P-F4ABDM-*
1792D-12BVT4D
1792D-4BVT4D
1792D-8BVT8D
1792D-8BIO8E
(2) DC Micro 879D-F4ACDM-* 879D-C3ACD4M-‡ 871A-VS4-DM
(2) Pico 3-Pin 879PZ-F3ABDM4-*
(2) Pico 4-Pin 879PZ-F4ABDM-*
(1) DC Micro 889D-F4ACDM-* 889D-M4AC-‡ 871A-TS4-DM
(1) Pico 3-Pin 889P-F3ABDM4-*
(1) Pico 4-Pin 889P-F4ABDM-*
1792D-12BT4PE
1792D-8BT8PE
1792D-8BVT8CD
(2) DC Micro 879D-F4ACD5M-* 879D-F4D5M + (2)
889D-M4AC-‡
871A-VS5-DM
(2) Pico 3-Pin 879D-F4D5M + (2)
889P–F3ABDM4-*
(2) Pico 4-Pin 879D-F4D5M + (2)
889P–F4ABDM-*
(1) DC Micro 889D-F4ACDM-* 889D-M4AC-‡ 871A-TS4-DM
(1) Pico 3-Pin 889P-F3ABDM4-*
(1) Pico 4-Pin 889P-F4ABDM-*
* = length in meters (1, 2, 3, 5, and 10 standard).
‡ = length in meters (2, 5, and 10 standard).

ArmorBlock MaXum Network Mating Cables
ArmorBlock Cat. No. Network Connector Type Flat Media Thick Round Thin Round
1792D-CB12
1792D-CB12JP
DeviceNet 1485K-P§F5-R5 1485R-P§M5-R5 1485R-P§R5-D5
1792D-CB18
1792D-CB18JP
DeviceNet 1485K-P§F5-N5 1485R-P§N5-M5 1485R-P§D5-N5
1792D-CB18P
1792D-CB18PT
DeviceNet 1485K-P§F5-N5 1485R-P§N5-M5 1485R-P§D5-N5
1485R-P§M5-R5
1792D-CBFM DeviceNet 1485C-P1E*
1485C-P1G*
1485C-P1K*
* = length in meters (75, 200, or 420).
§ = length in meters (1, 2, 3, 4, 5, and 6 standard).

ArmorBlock MaXum Auxiliary Power Mating Cables
ArmorBlock Cat. No. Flat Media Round Media
Auxiliary Power Flat Media Connection Cordset (single-ended) Patchcord (double-ended)
1792D-CB12 889D-F2ACDM-K§ Cordset: 889D-F4AC-‡
Patchcord: 889D-F2AEN4M-D§
Cordset: 889D-F4AC-‡
Patchcord: 889D-F4ACDM-§
1792D-CB18
1792D-CB18P
1792D-CB18PT
1485T-P1E4-C§-N4 889N-F4AFC-µF 889N-F4AFNM-§
1792D-CB12JP
1792D-CB18JP
Internally jumpered from network power Internally jumpered from network power Internally jumpered from network power
1792D-CBFM 1485C-P1L*
* = length in meters (75, 200, or 420).
‡ = length in meters (2, 5, and 10 standard).
§ = length in meters (1, 2, 3, 4, 5, and 6 standard).
µ = length in feet (6, 12, and 20 standard).