Catalogs > Automation Systems Catalog > I/O > Overview
Overview
Chassis-based I/OChassis-based I/O is specifically designed for a particular controller, as part of its family. Allen-Bradley chassis-based I/O systems are also capable of being mounted away from the controller via networks.
|
|
|
|
|
|
|
|
| 1756 ControlLogix I/O | 1769 Compact I/O | 1771 Universal I/O | 1746 SLC I/O | 1762 MicroLogix 1100 and 1200 I/O | 1755 GuardPLC 2000 I/O | |
| I/O Types | Digital, Analog, Thermocouple, RTD, Motion | Digital, Analog, Thermocouple, RTD | Digital, Analog, Thermocouple, RTD | Digital, Analog, Thermocouple, RTD | Digital, Analog, Thermocouple, RTD | Digital, Analog, Thermocouple, RTD |
| Module Density | 4 to 32 points per module | 4 to 32 points per module | 4 to 32 points per module | 4 to 32 points per module | 4 to 16 points per module | 4 to 40 points per module |
| Primary Controller (in bold) and Compatible Controllers |
ControlLogix, SoftLogix5800 | CompactLogix, MicroLogix 1500, SoftLogix5800 | PLC-5, ControlLogix, SoftLogix5800 | SLC 500, PLC-5 | MicroLogix 1100 and 1200 (Local Only) | GuardPLC 2000 |
| Specialty Modules | Counter In Positioning Module Hi-Res Frequency Monitor Flow Totalizer Rate Meter Serial ASCII Hydraulic Control Weigh Scale Resolver Interface Programmable Limit Switches LDT Interface Sequence of Events Input |
Counter In Resolver Interface Serial ASCII Address Reserve Module LDT Interface Weigh Scale Stepper Module Strain Gage Boolean |
Counter In Positioning Module Hi-Res Frequency Monitor Flow Totalizer Rate Meter Serial ASCII Temperature Control Hydraulic Control Weigh Scale Plastics Resolver Interface Programmable Limit Switches Serial Synchronous Interface (SSI) LDT Interface Time Stamp Die Monitoring Signature Analysis |
Counter In Positioning Module Serial ASCII Temperature Control Hydraulic Control Weigh Scale Plastics Resolver Interface Programmable Limit Switches LDT Interface Die Monitoring Signature Analysis |
— | — |
| Network Connectivity | ControlNet, EtherNet/IP, DeviceNet, Universal Remote I/O | DeviceNet | ControlNet, Universal Remote I/O | Universal Remote I/O, ControlNet | EtherNet/IP, DeviceNet, DH-485 (Local only) | GuardPLC Ethernet |
| Environmental Style | IP20, Class I, Division 2/Zone 2 | IP20, Class I, Division 2/Zone 2 | IP20, Class I, Division 2/Zone 2 | IP20, Class I, Division 2/Zone 2 | Class I, Division 2 | IP20 |
| Max. Modules per Chassis/Controller | Up to 16 modules per chassis | Up to 30 local modules | Up to 16 modules per chassis | Up to 13 modules per chassis Max. 3 chassis, 30 modules per CPU/node |
Up to 4 local modules for MicroLogix 1100 Up to 6 local modules for MicroLogix 1200 |
Up to 6 modules per chassis |
| For product certification information go to http://www.ab.com/certification. | ||||||
Cables and Cordsets
| Connect to your Allen-Bradley sensors or other field devices with the following cables and cordsets. | ||||||
|
|
|
|
|||
| Bulletin 1667 PanelConnect |
Plus | Bulletin 889 Patchcord |
Plus | Bulletin 898 Distribution Box |
Plus | Bulletin 889 Patchcord |
| OR | ||||||
|
|
|
|
|
|||
| Bulletin 888 Receptacle |
Plus | Bulletin 889 Patchcord |
Plus | Bulletin 898 Distribution Box |
Plus | Bulletin 889 Patchcord or Bulletin 879 Y-Cable |
| OR | ||||||
|
|
|
||||
| Bulletin 898 Distribution Box |
Plus | Bulletin 889 Patchcord or Bulletin 879 Y-Cable |
||||
| OR | ||||||
|
|
|
|||||
| Bulletin 888 Receptacle | Plus | Bulletin 889 Patchcord | ||||
| OR | ||||||
|
|
||||||
| Bulletin 889 Cordset | ||||||
| For additional information on Allen-Bradley wiring and connection systems, go to www.ab.com/io and www.ab.com/sensors. | ||||||