SLC Processors
SLC ProcessorsThe SLC processors offer a wide range of choices in memory, I/O capacity, instruction set, and communication ports to allow you to tailor a control system to your exact application requirements. These products have a strong reliability history covering hundreds of thousands of installations in a broad range of applications.
SLC 5/01 processors let you configure modular controllers of up to 960 I/O and a 1K- or 4K-instruction memory capacity.
SLC 5/02 processors let you configure modular controllers of up to 4096 inputs plus 4096 outputs nominally and a 4K-instruction memory. By installing an optional scanner module into one of the 30 I/O module slots, you can add ControlNet I/O, DeviceNet I/O, or Universal Remote I/O to the system. They offer 19 additional instructions, including a message instruction for initiating peer-to peer communication.
SLC 5/03 processors let you configure modular controllers of up to 4096 inputs plus 4096 outputs and a memory of 8K, 16K, or 32K words. In addition to the features of the SLC 5/02, they have a second built-in communication port—an RS-232-C port that can be configured for ASCII or DF1 protocol, and can be configured for connection to a 1761-NET-AIC converter to provide access to a DH-485 network. SLC 5/03 processors provide bit-instruction execution times of 0.44 ms and an overall system throughput of up to 10 times faster than competitive processors. Additional capabilities include: floating-point math, online programming and run-time editing, flash memory upgrades, built-in key-switch, and a built-in real-time clock and calendar.
SLC 5/04 and 5/05 processors let you configure modular controllers of up to 4096 inputs plus 4096 outputs and a memory of either 16K, 32K, or 64K words. They have all the features of the SLC 5/03 processors, plus a faster communication port and shorter execution times (bit-instruction execution times of 0.37ms). Instead of a DH-485 port, the SLC 5/04 has a built-in DH+ port for communication with other SLC 5/04 and PLC processors, operator interfaces, and programming terminals. Communication via the DH+ network is three times faster than DH-485 communication. SLC 5/05 processors provide a 10/100BASE-T, 10 or 100 Mbps Ethernet port.
Benefits
- Simple and affordable processors with broad capabilities to address applications such as material handling, HVAC control, assembly operations, small process control, and SCADA applications.
- Advanced instruction set based on PLC-5 mid-size processors.
- Broad line of digital and analog I/O modules, including intelligent I/O modules and including I/O modules available from third-party (Encompass™ program) vendors.
- Each SLC 5/01 processor has a DH-485 port for programming and processor-to-processor communication initiated from the other node.
- SLC 5/02, SLC 5/03, SLC 5/04 and SLC 5/05 processors have communication ports (Ethernet, DH+, DH-485, or RS-232-C) that can initiate communication.
- Add ControlNet I/O (1771-, 1746-, 1793-, 1794-, 1797-I/O modules) with a 1747-SCNR15 scanner module.
- Add DeviceNet I/O (1791D-, 1793-, and 1794-I/O module and 1792-I/O blocks) with a 1747-SDN scanner module.
- Add Universal Remote I/O (1746-, 1771-, 1793-, and 1794-I/O modules and 1791-I/O blocks) with a 1747-SN scanner module.
- Add BASIC programming capability and DH-485 and RS-232 communication ports with a 1746-BAS or 1746-BAS-T module.
Specifications
| Battery, SLC 5/01, 5/02, 5/03, 5/04, 5/05 | 1747-BA |
| Module Compatibility | SLC 5/01 processors are not compatible with 1746-BLM, 1746-BTM, 1746-MPM, 1746-HS, 1746-HSCE, 1746-QV, 1747-SN, 1747-SDN, and 1747-SCNR15 modules SLC 5/02 processors are not compatible with 1746-BLM and 1746-MPM modules |
| Operating Shock | 30 g (modular hardware) |
| Vibration | |
| 0.015 inches peak-to-peak at 5…57 Hz | |
| 2.5 g at 57…2000 Hz | |
| 1 hr per axis (x, y, z) (fixed hardware) | |
| Environmental conditions | |
| 0…60 °C (32…140 °F) | |
| -40…85 °C (-40…185 °F) | |
| 5…95% noncondensing | |
| Programming devices | RSLogix 500 Software |
Selecting the Processor Category
| Processor Category | I/O, Max. | I/O Communication | User Memory, Max. | General Communication Ports |
| SLC 5/01 | 960 | Processor-resident local I/O | 1K or 4K instructions | DH-485 (cannot initiate messages) |
| SLC 5/02 | 4096 in + 4096 out | Processor-resident local I/O I/O at remote locations⋆ |
4K instructions | DH-485 |
| SLC 5/03 | 4096 in + 4096 out | Processor-resident local I/O I/O at remote locations⋆ |
8K, 16K, or 32K words total | DH-485 RS-232 |
| SLC 5/04 | 4096 in + 4096 out | Processor-resident local I/O I/O at remote locations⋆ |
16K, 32K, or 64K words total | DH+ RS-232 |
| SLC 5/05 | 4096 in + 4096 out | Processor-resident local I/O I/O at remote locations⋆ |
16K, 32K, or 64K words total | Ethernet RS-232 |
| ⋆ This type of I/O in this type of controller system requires a separate I/O scanner installed in an I/O module slot to provide a ControlNet, DeviceNet, or Universal Remote I/O port. Configurable for communication through a 1761-NET-AIC in a DH-485 network or through a 1761-NET-DNI in a DeviceNet network. |
||||
SLC Processors
- Use the following tables to select the SLC processor that fits your application.
- Data table maximum words is user configured.
- Maximum timers/counters is restricted only by memory.
| Cat. No. | User Memory, Max. | Number of I/O | Local Analog I/O, Max. | Program Scan Time/Kword | I/O Scan Time |
| SLC 5/01 Processor | |||||
| 1747-L511 | 1K instructions | 960 absolute maximum (local) | 480 | 8 ms (typ) | 2.6 ms (typ) |
| 1747-L514 | 4K instructions | ||||
| SLC 5/02 Processor | |||||
| 1747-L524 | 4K instructions | 4096 in + 4096 out absolute maximum § |
480 | 4.8 ms (typ) | 1.6 ms (typ) |
| SLC 5/03 Processor⋆ | |||||
| 1747-L531 | 8K words total (4K words for data or prog.) (4K words for data only) |
4096 in + 4096 out absolute maximum § |
480 | 1 ms (typ) | 0.225 ms (typ) |
| 1747-L532 | 16K words total (12K words for data or prog.) (4K words for data only) |
||||
| 1747-L533 | 32K words total (28K words for data or prog.) (4K words for data only) |
||||
| SLC 5/04 Processor | |||||
| 1747-L541 | 16K words total (12K words for data or prog.) (4K words for data only) |
4096 in + 4096 out absolute maximum § |
480 | 0.9 ms (typ) | 0.225 ms (typ) |
| 1747-L542 | 32K words total (28K words for data or prog.) (4K words for data only) |
||||
| 1747-L543 | 64K words total (60K words for data or prog.) (4K words for data only) |
||||
| SLC 5/05 Processor ♣ | |||||
| 1747-L551 | 16K words total (12K words for data or prog.) (4K words for data only) |
4096 in + 4096 out absolute maximum § |
480 | 0.9 ms (typ) | 0.225 ms (typ) |
| 1747-L552 | 32K words total (28K words for data or prog.) (4K words for data only) |
||||
| 1747-L553 | 64K words total (60K words for data or prog.) (4K words for data only) |
||||
| ⋆ Modbus slave protocol is embedded in the RTU-5/03 processors available from an Encompass partner. The Modbus slave protocol is supported on the RS-232 port (channel0). For information on the Encompass program visit: www.rockwellautomation.com/encompass/. The absolute maximum number of I/O for these processors only reflects the I/O addressing capability. It does not take into account the amount of memory that may be required for a ladder-logic program to monitor and control the I/O. The practical ratio of memory per I/O is totally dependant upon your specific application. § You cannot configure this number of I/O for these processors with local I/O only. To configure this number of I/O for these processors, you must add a 1747-SN Remote I/O Scanner module to configure I/O on a Universal Remote I/O link, add a 1747-SDN DeviceNet Scanner module to configure I/O on a DeviceNet network and/or add a 1747-SCNR ControlNet Scanner module to configure I/O on a ControlNet network. ♣ The 5/05 Series C processors can communicate to 100 Mbps and support increased Ethernet connections: 1747-L551=32 connections; 1747-L552=48 connections; 1747-L553=64 connections. |
|||||
SLC Processors (continued)
| Cat. No. | No. of Local I/O Chassis, Max. | No. of I/O Module Slots in the Local I/O Chassis, Max. | Communication Ports |
Backup Memory |
Battery-backed RAM |
Backplane Current Load |
| SLC 5/01 Processor | ||||||
| 1747-L511 1747-L514 |
3 | 30 | DH-485 | EEPROM | Option | 350 mA at 5V DC 105 mA at 24V DC |
| SLC 5/02 Processor | ||||||
| 1747-L524 | 3⋆ | 30 | DH-485 | EEPROM | Standard | 350 mA at 5V DC 105 mA at 24V DC |
| SLC 5/03 Processor | ||||||
| 1747-L531 1747-L532 1747-L533 |
3⋆ | 30 | DH-485 RS-232§ |
Flash | Standard | 500 mA at 5V DC 175 mA at 24V DC |
| SLC 5/04 Processor | ||||||
| 1747-L541 1747-L542 1747-L543 |
3⋆ | 30 | DH+ RS-232♣ |
Flash | Standard | 1 A at 5V DC 0 A at 24V DC∆ |
| SLC 5/05 Processor | ||||||
| 1747-L551 1747-L552 1747-L553 |
3⋆ | 30 | Ethernet RS-232♣ |
Flash | Standard | 1 A at 5V DC 0 A at 24V DC |
| ⋆ With this processor, you can also install a 1747-SN Remote I/O Scanner module to configure I/O on a Universal Remote I/O link and/or add a 1747-SDN DeviceNet Scanner module to configure I/O on a DeviceNet network. You can configure 32 I/O chassis per Universal Remote I/O scanner using complementary I/O. If you dont use complementary I/O, you can configure 16 I/O chassis per Universal Remote I/O scanner. With the DeviceNet scanner, you can address a maximum of 63 DeviceNet devices over the DeviceNet network. An SLC 5/01 processor can only receive messages and send reply messages to command messages sent from other nodes on the DH-485 network; it cannot initiate communication. § The SLC 5/03 has an RS-232 port, which can also be configured for a DH-485 network, enabling the SLC-5/03 to connect to two DH-485 networks simultaneously. ♣ The SLC 5/04 and SLC 5/05 have an RS-232 port, which can also be configured for a DH-485 network. ∆ SLC 5/04 processors manufactured prior to April 2002 draw 200 mA @ 24V DC. Check the processor label to verify current draw. |
||||||
Memory Devices
| Cat. No. | Description | For this Product | Function | Memory Size |
| 1747-M1 | EEPROM | SLC 5/01 | Program and data table storage | 8 Kbytes, 1K instructions |
| 1747-M2 | EEPROM | SLC 5/01, 5/02 | Program and data table storage | 32 Kbytes, 4K instructions |
| 1747-M13 | Flash | SLC 5/03, 5/04, 5/05 | Program and data table storage | 64 Kbyte |