Catalogs > Automation Systems Catalog > Programmable Controllers > SLC 500 System > SLC Processors
SLC Processors
SLC Processors- Use the following tables to select the SLC processor that fits your application.
- Data table maximum words is user configured.
- Maximum timers/counters is restricted only by memory.
| Cat. No. | User Memory, Max. | Number of I/O | Local Analog I/O, Max. | Program Scan Time/Kword | I/O Scan Time |
| SLC 5/01 Processor | |||||
| 1747-L511 | 1K instructions | 960 absolute maximum (local) | 480 | 8 ms (typ) | 2.6 ms (typ) |
| 1747-L514 | 4K instructions | ||||
| SLC 5/02 Processor | |||||
| 1747-L524 | 4K instructions | 4096 in + 4096 out absolute maximum § |
480 | 4.8 ms (typ) | 1.6 ms (typ) |
| SLC 5/03 Processor⋆ | |||||
| 1747-L531 | 8K words total (4K words for data or prog.) (4K words for data only) |
4096 in + 4096 out absolute maximum § |
480 | 1 ms (typ) | 0.225 ms (typ) |
| 1747-L532 | 16K words total (12K words for data or prog.) (4K words for data only) |
||||
| 1747-L533 | 32K words total (28K words for data or prog.) (4K words for data only) |
||||
| SLC 5/04 Processor | |||||
| 1747-L541 | 16K words total (12K words for data or prog.) (4K words for data only) |
4096 in + 4096 out absolute maximum § |
480 | 0.9 ms (typ) | 0.225 ms (typ) |
| 1747-L542 | 32K words total (28K words for data or prog.) (4K words for data only) |
||||
| 1747-L543 | 64K words total (60K words for data or prog.) (4K words for data only) |
||||
| SLC 5/05 Processor ♣ | |||||
| 1747-L551 | 16K words total (12K words for data or prog.) (4K words for data only) |
4096 in + 4096 out absolute maximum § |
480 | 0.9 ms (typ) | 0.225 ms (typ) |
| 1747-L552 | 32K words total (28K words for data or prog.) (4K words for data only) |
||||
| 1747-L553 | 64K words total (60K words for data or prog.) (4K words for data only) |
||||
| ⋆ Modbus slave protocol is embedded in the RTU-5/03 processors available from an Encompass partner. The Modbus slave protocol is supported on the RS-232 port (channel0). For information on the Encompass program visit: www.rockwellautomation.com/encompass/. The absolute maximum number of I/O for these processors only reflects the I/O addressing capability. It does not take into account the amount of memory that may be required for a ladder-logic program to monitor and control the I/O. The practical ratio of memory per I/O is totally dependant upon your specific application. § You cannot configure this number of I/O for these processors with local I/O only. To configure this number of I/O for these processors, you must add a 1747-SN Remote I/O Scanner module to configure I/O on a Universal Remote I/O link, add a 1747-SDN DeviceNet Scanner module to configure I/O on a DeviceNet network and/or add a 1747-SCNR ControlNet Scanner module to configure I/O on a ControlNet network. ♣ The 5/05 Series C processors can communicate to 100 Mbps and support increased Ethernet connections: 1747-L551=32 connections; 1747-L552=48 connections; 1747-L553=64 connections. |
|||||
SLC Processors (continued)
| Cat. No. | No. of Local I/O Chassis, Max. | No. of I/O Module Slots in the Local I/O Chassis, Max. | Communication Ports |
Backup Memory |
Battery-backed RAM |
Backplane Current Load |
| SLC 5/01 Processor | ||||||
| 1747-L511 1747-L514 |
3 | 30 | DH-485 | EEPROM | Option | 350 mA at 5V DC 105 mA at 24V DC |
| SLC 5/02 Processor | ||||||
| 1747-L524 | 3⋆ | 30 | DH-485 | EEPROM | Standard | 350 mA at 5V DC 105 mA at 24V DC |
| SLC 5/03 Processor | ||||||
| 1747-L531 1747-L532 1747-L533 |
3⋆ | 30 | DH-485 RS-232§ |
Flash | Standard | 500 mA at 5V DC 175 mA at 24V DC |
| SLC 5/04 Processor | ||||||
| 1747-L541 1747-L542 1747-L543 |
3⋆ | 30 | DH+ RS-232♣ |
Flash | Standard | 1 A at 5V DC 0 A at 24V DC∆ |
| SLC 5/05 Processor | ||||||
| 1747-L551 1747-L552 1747-L553 |
3⋆ | 30 | Ethernet RS-232♣ |
Flash | Standard | 1 A at 5V DC 0 A at 24V DC |
| ⋆ With this processor, you can also install a 1747-SN Remote I/O Scanner module to configure I/O on a Universal Remote I/O link and/or add a 1747-SDN DeviceNet Scanner module to configure I/O on a DeviceNet network. You can configure 32 I/O chassis per Universal Remote I/O scanner using complementary I/O. If you dont use complementary I/O, you can configure 16 I/O chassis per Universal Remote I/O scanner. With the DeviceNet scanner, you can address a maximum of 63 DeviceNet devices over the DeviceNet network. An SLC 5/01 processor can only receive messages and send reply messages to command messages sent from other nodes on the DH-485 network; it cannot initiate communication. § The SLC 5/03 has an RS-232 port, which can also be configured for a DH-485 network, enabling the SLC-5/03 to connect to two DH-485 networks simultaneously. ♣ The SLC 5/04 and SLC 5/05 have an RS-232 port, which can also be configured for a DH-485 network. ∆ SLC 5/04 processors manufactured prior to April 2002 draw 200 mA @ 24V DC. Check the processor label to verify current draw. |
||||||