Catalogs > Automation Systems Catalog > Programmable Controllers > ControlLogix System > ControlLogix Controllers
ControlLogix Controllers
CompatibilityControl Distributed I/O Modules
The ControlLogix controller can control these distributed I/O modules using the I/O Configuration tree in RSLogix 5000 programming software.
| I/O Modules | EtherNet/IP | ControlNet | DeviceNet | Remote I/O |
| 1732 ArmorBlock I/O | Yes | No | Yes | No |
| 1734 POINT I/O | Yes | Yes | Yes | No |
| 1734D POINTBlock I/O | No | No | Yes | No |
| 1738 ArmorPoint I/O | Yes | Yes | Yes | No |
| 1746 SLC I/O | No | No | No | Yes |
| 1756 ControlLogix I/O | Yes | Yes | No | No |
| 1769 Compact I/O | No | No | Yes | No |
| 1771 Universal I/O | No | YesT | No | Yes |
| 1790 CompactBlock LDX I/O | No | No | Yes | No |
| 1791D CompactBlock I/O | No | No | Yes | No |
| 1792D ArmorBlock MaXum I/O | No | No | Yes | No |
| 1794 FLEX I/O | Yes | Yes | Yes | Yes |
| 1797 FLEX Ex I/O | No | Yes | No | No |
| 1798 FLEX Armor I/O | No | No | Yes | No |
| 1799 Embedded I/O | No | No | Yes | No |
| ¬ Requires RSLogix 5000 programming software version 11 or later. Use the generic FLEX profile. T Use a 1771-ACN15, 1771-ACNR15 adapter module. Version 10 and later of RSLogix 5000 Enterprise Series software supports 1771 digital, analog, and specialty I/O modules. Previous versions of the software support only 1771 digital I/O modules. |
||||
Communicate with Display Devices
The ControlLogix controller can communicate with these display devices.
| Display Devices | EtherNet/IP | ControlNet | DeviceNet | DH+ | Remote I/O | RS-232 (DF1) | DH-485 |
| 2711P PanelView Plus terminal | Yes | Yes | Yes | Yes | Yes | Yes | No¬ |
| 6182H VersaView CE computer | Yes | Yes | Yes | Yes | Yes | Yes | No¬ |
| 2711 PanelView terminal | Yes | Yes | Yes | YesT | Yes | YesT | YesT |
| 2711 e PanelView terminal | No | Yes | No | YesT | Yes | No | No |
| 800E, 800T RediSTATION/RediPANEL operator module | No | No | Yes | No | Yes | No | No |
| 2706 InView message display | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| 2706 DL40 Dataliner message display | No | No | No | No | Yes | Yes | No |
| 2706 DL, DL50 DataLiner message display | No | No | No | No | No | Yes | No |
| 2707 DTAM Plus operator interface | No | No | Yes | No | Yes | YesT | YesT |
| ¬ These devices support DH-485 communication to FlexLogix and CompactLogix controllers. T Use PLC/SLC mapping. |
|||||||
Communicate with Other Controllers
The ControlLogix controller can communicate with these controllers.
| Controller | EtherNet/IP | ControlNet | DeviceNet | DH+ | RS-232 (DF1) | DH-485§ |
| 1756 ControlLogix 1756 GuardLogix |
Yes | Yes | Yes | Yes | Yes | Yes |
| 1768, 1769 CompactLogix | Yes | Yes | Yes | No | Yes | Yes |
| 1789 SoftLogix5800 | Yes | Yes | Yes | No | Yes | No |
| 1794 FlexLogix | Yes | Yes | Yes | No | Yes | Yes |
| 5720 PowerFlex 700S with DriveLogix | Yes | Yes | Yes | No | Yes | Yes |
| 1785 PLC-5 | Yes¬ T | Yes | Yes | Yes | Yes | N/A |
| 1747 SLC | Yes§ | Yes | Yes | Yes§ | Yes | Yes |
| 1761 MicroLogix | Yes | No | Yes | No | Yes | Yes |
| 1762 MicroLogix | Yes | No | Yes | No | Yes | Yes |
| 1763 MicroLogix | Yes | No | Yes | No | Yes | Yes |
| 1764 MicroLogix | Yes | No | Yes | No | Yes | Yes |
| 1772 PLC-2 | N/A | N/A | N/A | YesØ | Yesz | N/A |
| 1775 PLC-3 | N/A | N/A | N/A | Yesª | Yesv | N/A |
| 5250 PLC-5/250 | N/A | N/A | No | Yes | Yes | N/A |
| ¬ The Ethernet PLC-5 controller must be series C, firmware revision N.1 or later; series D, firmware revision E.1 or later; or series E, firmware revision D.1 or later. T The 1785-ENET Ethernet communication interface module must be series A, firmware revision D or later. The PLC-5, SLC, and MicroLogix processors appear as I/O points to the Logix controller. Use the appropriate DeviceNet interface for the controller. § Use a 1747-L55x controller with OS501 or greater. Ø The PLC-2 controller requires a 1785-KA module for DH+ communications. z The PLC-2 controller requires a 1771-KG module for serial (DF1) communications. ª The PLC-3 controller requires a 1775-S5 module for DH+ communications. v The PLC-3 controller requires a 1775-KA module for serial (DF1) communications. § The 1756-DH485 module supports full DH-485 functionality. |
||||||
Communicate with Other Communication Devices
The ControlLogix controller can communicate with these communication devices.
| Communication Device | EtherNet/IP | ControlNet | DeviceNet | DH+ | RS-232 (DF1) | DH-485 |
| 1770-KFD | N/A | N/A | Yes | N/A | N/A | N/A |
| 9355 RSLinx software | Yes | Yes | No | Yes | Yes | No |
| 1784-KTC, 1784-KTCx, 1784-KTCx15, 1784-PCIC(S), 1784-PCC | N/A | Yes | N/A | N/A | N/A | N/A |
| 1784-PCIDS, 1784-PCD | N/A | N/A | Yes | N/A | N/A | N/A |
| 1784-KTX, 1784-KTXD, 1784-PCMK | N/A | N/A | N/A | Yes | N/A | N/A |
| 1788-CN2DN | N/A | Yes | Yes | N/A | N/A | N/A |
| 1788-EN2DN | Yes | N/A | Yes | N/A | N/A | N/A |
| 1788-CN2FF | N/A | Yes | N/A | N/A | N/A | N/A |
| 1203-CN1 ControlNet module | N/A | Yes¬ | N/A | N/A | N/A | N/A |
| 1203-FM1/FB1 SCANport | N/A | YesT | N/A | N/A | N/A | N/A |
| ¬ Use the generic module configuration to configure the 1203-CN1 module and a CIP generic MSG instruction to communicate with the module. T Use a CIP generic MSG instruction to communicate with the 1203-FM1 SCANport module on a DIN rail that is remote to the controller. The remote DIN rail also requires a 1794-ACN(R)15 ControlNet adapter module. |
||||||