Power Supplies

ControlLogix Power Supplies Overview

Click to enlarge - 1756 Power Supply_BW


ControlLogix power supplies are used with the 1756 chassis to provide 1.2V, 3.3V, 5V, and 24V DC power directly to the chassis backplane. Select from these configurations:


Features


Environmentals and Certifications

ControlLogix Power Supplies Environmental Specifications

  ControlLogix Standard and Redundant Power Supplies ControlLogix-XT Power Supplies
Operating temperature
0…60 °C (32…140 °F) -25…70 °C (-13…158 °F)
Storage temperature
-40…85 °C (-40…185 °F) -40…85 °C (-40…185 °F)
Relative humidity
5…95% noncondensing 5…95% noncondensing
Vibration
2 g @ 10…500 Hz 2 g @ 10…500 Hz
Operating shock
30 g 30 g
Nonoperating shock
50 g 50 g

ControlLogix Power Supplies Certifications

Certifications: c-UL-us, CE, CSA, C-Tick, FM, ATEX, TÜV.

When product is marked. See the Product Certification link at www.ab.com for Declarations of Conformity, Certificates, and other certification details. For TÜV and SIL certification details, see the Safety Certifications and SIL link.


ControlLogix Standard Power Supplies

Click to enlarge - 1756 Power Supply_BW


You mount a standard power supply directly on the left end of the chassis, where it plugs directly into the backplane.

Specifications [PDF]

ControlLogix Standard Power Supplies

Cat. No. Description Voltage Category Operating Voltage Range Chassis
1756-PA72 ControlLogix standard power supply 120V/220V AC 85…265V AC Standard, series A and series B
1756-PB72 24V DC 18…32V DC Standard, series A and series B
1756-PA75 120V/220V AC 85…265V AC Standard series B
1756-PB75 24V DC 18...32V DC Standard series B
1756-PC75 48V DC 30…60V DC Standard series B
1756-PH75 125V DC 90…143V DC Standard series B

ControlLogix-XT Power Supplies

The ControlLogix-XT products include control and communication system components that, when used with FLEX I/O-XT products, provide a complete control system solution that can be used in environments where temperatures range from ‑20...70 °C (‑4...158 °F).

When used independently, the ControlLogix-XT system can withstand environments where the temperature ranges from ‑25...70 °C (‑13...158 °F).


ControlLogix-XT Power Supplies

Specifications [PDF]

Cat. No. Description Voltage Category Operating Voltage Range Chassis
1756-PBXT ControlLogix-XT power supply 24V DC 18…32V DC XT

ControlLogix Redundant Power Supplies

To build a redundant power supply system, you need:


The 1756-PSCA2 chassis adapter module is a passive device that funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane.

ControlLogix Redundant Power Supplies

Specifications [PDF]

Cat. No. Description Voltage Category Operating Voltage Range Chassis
1756-PA75R ControlLogix redundant power supply 120V/220V AC 85…265V AC Standard series B
1756-PB75R 24V DC 19.2…32V DC Standard series B

Accessories—Redundant Power Supplies

Cat. No. Description Specifications
1756-PSCA2 Chassis adapter module. Funnels power from the redundant power supplies to the single power connector on the ControlLogix series B chassis backplane. Mounts directly to left side of 1756 chassis
1756-CPR2 Chassis adapter cable. Connects redundant power supply to 1756-PCSA2 chassis adapter. Length: 0.91 m (3 ft)