Software
Software for a ControlLogix SystemYour selection of modules and network configuration determines what software packages you need to configure and program your system.
The FactoryTalk suite from Rockwell Software extends the Rockwell Automation Integrated Architecture by providing an information tier of software applications and services for production and performance management. Tight integration with the Rockwell Automation Logix control platform, as well as connectivity to third-party and legacy systems can help deliver a seamless flow of high-fidelity data across your enterprise.
1756 System Software
| If you have | You need | Order |
| 1756 ControlLogix controller | RSLogix 5000 Enterprise Series software | 9324 series |
| 1756 SERCOS or analog motion module | ||
| 1756-CN2, 1756-CN2R 1756-CN2RXT 1756-CNB, 1756-CNBR ControlNet communication module |
RSNetWorx for ControlNet software (comes with the Standard/NetWorx and Professional Editions of RSLogix 5000 Enterprise Series software) |
9324-RLD300NXENE (RSNetWorx option) or 9324-RLD700NXENE (RSLogix 5000 Professional software) or 9357-CNETL3 (RSNetWorx for ControlNet) |
| 1756-DNB DeviceNet communication module |
RSNetWorx for DeviceNet software (comes with the Standard/NetWorx and Professional Editions of RSLogix 5000 Enterprise Series software) |
9324-RLD300NXENE (RSNetWorx option) or 9324-RLD700NXENE (RSLogix 5000 Professional software) or 9357-DNETL3 (RSNetWorx for DeviceNet) |
| 1756-EN2F, 1756-EN2T 1756-EN2TXT 1756-ENBT, 1756-EWEB EtherNet/IP communication module (set the IP address) |
RSLinx software or BOOTP/DHCP server utility to set IP addresses (RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software) Optional RSNetWorx for EtherNet/IP software (comes with the Standard/RSNetWorx and Professional Editions of RSLogix 5000 Enterprise Series software) |
9324 series Optional 9357-ENETL3 (RSNetWorx for EtherNet/IP) |
| 1756-DHRIO, 1756-DHRIOXT communication module 1756-DH485 communication module |
RSLinx software | 9324 series |
| 1757-FFLD2, 1757-FFLD4 1757-FFLDC2, 1757-FFLDC4 Foundation Fieldbus linking device |
RSFieldbus Configuration Software | 9308 series |
| Communication card in a workstation | RSLinx software (RSLinx Lite comes with RSLogix 5000 Enterprise Series software) |
9324 series |
RSLogix 5000 Programming Software
RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms. RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder, structured text, function block diagram, and sequential function chart editors for you to develop application programs. Create your own instructions by encapsulating a section of logic in any programming language into an Add-On Instruction.
RSLogix 5000 Enterprise Series Software Packages
- Replace xx in the catalog number with the appropriate language designation: ZH=Chinese, EN=English, FR=French, DE=German, IT=Italian, JP=Japanese, KO=Korean, PT=Portuguese, and ES=Spanish.
- For upgrades from one package to another, see the StepForward program.
- Programming features available for purchase as a separate software package are noted, and the corresponding catalog number is listed in bold. For example, DriveExecutive Lite is available separately, and can be ordered using catalog number 9303-4DTE01ENE.
| RSLogix 5000 Development Features | |||||||
| Edition | Service Edition | Mini Edition | Lite Edition | Standard Edition | Standard/ NetWorx Edition | Full Edition | Professional Edition |
| Cat. No. | 9324-RLD000xxE | 9324-RLD200xxE | 9324-RLD250xxE | Node Locked: 9324-RLD300xxE Concurrent License: 9324-RLD300xxF |
9324-RLD300NXxxE | Node Locked: 9324‑RLD600xxE Concurrent License:⋆ 9324‑RLD600xxF |
Node Locked: 9324‑RLD700NXxxE Concurrent License:⋆ 9324‑RLD700NXxxF |
| Logix5000 controllers supported | All | CompactLogix | CompactLogix | All | All | All § | All |
| Relay ladder diagram editor ♣ | Upload/download and view | Full support | Full support | Full support | Full support | Full support | Full support |
| Function block diagram 9324-RLDFBDENE ♣ |
Upload/download and view | Upload/download Available separately |
Full support | Upload/download Available separately |
Upload/download Available separately |
Full support | Full support |
| Sequential function chart editor 9324-RLDSFCE ♣ ∆ |
Upload/download and view | Upload/download Available separately |
Full support | Upload/download Available separately |
Upload/download Available separately |
Full support | Full support |
| Structured text editor 9324-RLDSTXE ♣ |
Upload/download and view | Upload/download Available separately |
Full support | Upload/download Available separately |
Upload/download Available separately |
Full support | Full support |
| PhaseManager 9324-RLDPME |
Upload/download and view | Upload/download Available separately |
Upload/download Available separately |
Upload/download Available separately |
Upload/download Available separately |
Full support | Full support |
| GuardLogix Safety Editor 9324-RLDGLXE ♦ |
Upload/download and view | Upload/download Available separately |
Full Support | Upload/download Available separately |
Upload/download Available separately |
Full support | Full support |
| Highly integrated motion | Upload/download and view | Full Support | Full support | Full support | Full support | Full support | Full support |
| Graphical trending | Full support | Full support ♠ | Full support ♠ | Full support | Full support | Full support | Full support |
| DriveExecutive Lite 9303-4DTE01ENE |
Available separately | Available separately | Available separately | Included | Included | Included | Included |
| PIDE autotune 9323-ATUNEENE ∇ |
Available separately | Available separately | Available separately | Available separately | Available separately | Included | Included |
| Advanced Process Control instructions 9324-RLDAPCENE 9324-RLDAPCCLENE& |
Upload/download and view only | Available separately | Available separately | Available separately | Available separately | Available separately | Available separately |
| Routine source protection | Included | Included | Included | Included | Included | Included | Included |
| RSLogix 5000 project compare | Included | Included | Included | Included | Included | Included | Included |
| ⋆ As of RSLogix 5000 programming software, version 16. The software is designed to grab the highest functionality license first. For example, if Standard, Full and Professional Concurrent licenses are available on the FactoryTalk Activation server, RSLogix 5000 software will grab the highest functionality license first. Service Edition supports controllers with firmware revision 12 and later. § Full Edition supports controllers with firmware revision 10 and later. ♣ A multiple language editor package is available as 9324-RLDMLPE. It contains the function block, sequential function chart, and structured text editors. ∆ The Structured Text editor option (9324-RLDSTXE) is required to program SFC actions in structured text. ♦ As of RSLogix 5000 programming software, version 16. ♠ As of RSLogix 5000 programming software, version 15. ∇ PIDE Autotune is not supported on 1769-L23x controllers. & Select 9324-RLDAPCENE for a design license for software and a runtime license for one controller. Select 9324-RLDAPCCLENE for only a runtime license for one controller (for pay to deploy). |
|||||||
| RSLogix 5000 Integration with Other Applications | |||||||
| Edition | Service Edition | Mini Edition | Lite Edition | Standard Edition | Standard/ NetWorx Edition | Full Edition | Professional Edition |
| Cat. No. | 9324-RLD000xxE | 9324-RLD200xxE | 9324-RLD250xxE | Node Locked: 9324-RLD300xxE Concurrent License: 9324-RLD300xxF |
9324-RLD300NXxxE | Node Locked: 9324‑RLD600xxE Concurrent License:⋆ 9324‑RLD600xxF |
Node Locked: 9324‑RLD700NXxxE Concurrent License:⋆ 9324‑RLD700NXxxF |
| RSLinx Classic software | Lite included | Lite included | Lite included | Lite included | Lite included | Lite included | Lite included |
| RSNetWorx ControlNet, RSNetWorx DeviceNet, RSNetWorx EtherNet/IP software |
Available separately | Available separately | Available separately | Available separately | Included | Available separately | Included |
| FactoryTalk AssetCentre audit support | Included | Included | Included | Included | Included | Included | Included |
| FuzzyDesigner 9324-RLDFZYENE § |
NA | Available separately | Available separately | Available separately | Available separately | Available separately | Available separately |
| RSLogix Emulate 5000 9310-WED200ENE ♣ |
Available separately | NA | NA | Available separately | Available separately | Available separately | Included |
| FactoryTalk security server ∆ |
Included | Included | Included | Included | Included | Included | Included |
| Security server emulator ∆ | Included | Included | Included | Included | Included | Included | Included |
| RSLogix Architect 9326-LGXARCHENE ♦ |
Available separately | Available separately | Available separately | Available separately | Available separately | Available separately | Included |
| FactoryTalk View SE demo (50 tags/2 hours) |
Available separately | Available separately | Available separately | Available separately | Available separately | Available separately | Included |
| ⋆ As of RSLogix 5000 programming software, version 16. The software is designed to grab the highest functionality license first. For example, if Standard, Full and Professional Concurrent licenses are available on the FactoryTalk Activation server, RSLogix 5000 software will grab the highest functionality license first. RSNetWorx for ControlNet software is 9357-CNETL3. RSNetWorx for DeviceNet software is 9357-DNETL3. RSNetWorx for EtherNet/IP software is 9357-ENETL3. They are available together as 9357-ANETL3. § As of RSLogix 5000 programming software, version 16. ♣ RSLogix Emulate 5000 software does not support Microsoft Windows Vista at this time. ∆ FactoryTalk AP install required - included on disk. ♦ As of RSLogix 5000 programming software, version 15. |
|||||||
RSLogix 5000 Enterprise Series Software Requirements
| Description | Value |
| Minimum System Requirements for RSLogix 5000 | Pentium 4 2.8 GHz processor 1 GB RAM 16 GB available hard disk space 1024x768, True Color graphics device |
| Recommended System For Best User Experience And Faster Downloads | Intel Core i5 2.4GHz processor 8 GB available hard disk space 20GB available free disk space DirectX 9 graphics device with WDDM 1.0 or higher driver |
| Operating System Support | RSLogix 5000 V20 software has been tested on the following operating systems: Microsoft Windows 7 Professional (64-bit) with Service Pack 1a Microsoft Windows 7 Home Premium (64-bit) with Service Pack 1 a Microsoft Windows 7 Home Premium (32-bit) with Service Pack 1 a Microsoft Windows Vista Business (32-bit) with Service Pack 2 b Microsoft Windows XP Professional with Service Pack 3 Microsoft Windows Server 2008 R2 Standard Edition with Service Pack 1 Microsoft Windows Server 2008 Standard Edition with Service Pack 2 Microsoft Windows Server 2003 R2 Standard Edition with Service Pack 2 |
| Notes | 1. User account control (UAC) must be set to always notify. 2. User account control (UAC) must be turned on. |