Software

Your selection of modules and network configuration determines what software packages you need to configure and program your system.

Software

If you have You need Order
CompactLogix controller RSLogix 5000 Enterprise Series software 9324 series
(RSLogix 5000 Enterprise Series software)
Use Lite Edition or higher to support motion.
If no motion, you can use the Service Edition or Mini Edition.
SERCOS motion interface
(1768 controller only)
EtherNet/IP interface
(set the IP address)
RSLinx software
or
BOOTP/DHCP server utility to set IP addresses
(RSLinx Lite and BOOTP server come with RSLogix 5000 Enterprise Series software)

optional RSNetWorx for EtherNet/IP software
(comes with the standard/RSNetWorx option of RSLogix 5000 Enterprise Series software)
9324 series
(RSLogix 5000 Enterprise Series software)
or
9324-RLD300NXENE (RSLogix 5000 Enterprise Series software plus RSNetWorx option)

optional 9357-ENETL3 (RSNetWorx for EtherNet/IP)
ControlNet interface RSNetWorx for ControlNet software
(comes with the standard/RSNetWorx option of RSLogix 5000 Enterprise Series software)
9324-RLD300NXENE (RSLogix 5000 Enterprise Series software plus RSNetWorx option)
or
9357-CNETL3 (RSNetWorx for ControlNet)
DeviceNet interface RSNetWorx for DeviceNet software
(comes with the standard/RSNetWorx option of RSLogix 5000 Enterprise Series software)
9324-RLD300NXENE (RSLogix 5000
Enterprise Series software plus RSNetWorx option)
or
9357-DNETL3 (RSNetWorx for DeviceNet)
Communication card in a workstation RSLinx software
(RSLinx Lite comes with RSLogix 5000 Enterprise Series software)
9324 series
(RSLogix 5000 Enterprise Series software)
Logix-based system to emulate RSLogix Emulate 5000 software 9310-WED200ENE
  

RSLogix 5000 Programming Software

RSLogix 5000 Enterprise Series software is designed to work with Logix5000 controller platforms. RSLogix 5000 Enterprise Series software is an IEC 61131-3 compliant software package that offers relay ladder, structured text, function block diagram, and sequential function chart editors for you to develop application programs. Create your own instructions by encapsulating a section of logic in any programming language into an Add-On Instruction.

For more information on Rockwell Software products for the Logix control platform, go to: http://www.rockwellautomation.com/rockwellsoftware/products/.

RSLogix 5000 Enterprise Series Software Packages


RSLogix 5000 Development Features
Edition Service Edition Mini Edition Lite Edition Standard Edition Standard/ NetWorx Edition Full Edition Professional Edition
Cat. No. 9324-RLD000xxE 9324-RLD200xxE 9324-RLD250xxE Node Locked:
9324-RLD300xxE
Concurrent License:
9324-RLD300xxF
9324-RLD300NXxxE Node Locked:
9324‑RLD600xxE
Concurrent License:¬ 
9324‑RLD600xxF
Node Locked:
9324‑RLD700NXxxE
Concurrent License:¬ 
9324‑RLD700NXxxF
Logix5000 controllers supported All T  CompactLogix
FlexLogix
CompactLogix
FlexLogix
All All All ‡  All
Relay ladder diagram editor §  Upload/download and view Full support Full support Full support Full support Full support Full support
Function block diagram
9324-RLDFBDENE § 
Upload/download and view Upload/download
Available separately
Full support Upload/download
Available separately
Upload/download
Available separately
Full support Full support
Sequential function chart editor
9324-RLDSFCE §  § 
Upload/download and view Upload/download
Available separately
Full support Upload/download
Available separately
Upload/download
Available separately
Full support Full support
Structured text
9324-RLDSTXE § 
Upload/download and view Upload/download
Available separately
Full support Upload/download
Available separately
Upload/download
Available separately
Full support Full support
PhaseManager
9324-RLDPME
Upload/download Upload/download
Available separately
Upload/download
Available separately
Upload/download
Available separately
Upload/download
Available separately
Full support Full support
GuardLogix Safety
9324-RLDGLXE Ø 
Upload/download and view NA NA Upload/download
Available separately
Upload/download
Available separately
Full support Full support
Highly integrated motion Upload/download and view Upload/download Full support Full support Full support Full support Full support
Graphical trending Full support Full support z  Full support z  Full support Full support Full support Full support
DriveExecutive Lite
9303-4DTE01ENE
Available separately Available separately Available separately Included Included Included Included
PIDE autotune
9323-ATUNEENE ª 
Available separately Available separately Available separately Available separately Available separately Included Included
Advanced Process Control instructions
9324-RLDAPCENE
9324-RLDAPCCLENEv 
Upload/download and view Available separately Available separately Available separately Available separately Available separately Available separately
Routine source protection Included Included Included Included Included Included Included
RSLogix 5000 project compare Included Included Included Included Included Included Included
¬ As of RSLogix 5000 programming software, version 16. The software is designed to grab the highest functionality license first. For example, if Standard, Full and Professional Concurrent licenses are available on the FactoryTalk Activation server, RSLogix 5000 software will grab the highest functionality license first.
T Service Edition supports controllers with firmware revision 12 and later.
‡ Full Edition supports controllers with firmware revision 10 and later.
§ A multiple language editor package is available as 9324-RLDMLPE. It contains the function block, sequential function chart, and structured text editors.
§ The Structured Text editor option (9324-RLDSTXE) is required to program SFC actions in structured text.
Ø As of RSLogix 5000 programming software, version 16.
z As of RSLogix 5000 programming software, version 15.
ª PIDE Autotune is not supported on 1769-L23x controllers.
v Select 9324-RLDAPCENE for a design license for software and a runtime license for one controller. Select 9324-RLDAPCCLENE for only a runtime license for one controller (for pay to deploy).

RSLogix 5000 Integration with Other Applications
Edition Service Edition Mini Edition Lite Edition Standard Edition Standard/ NetWorx Edition Full Edition Professional Edition
Cat. No. 9324-RLD000xxE 9324-RLD200xxE 9324-RLD250xxE Node Locked:
9324-RLD300xxE
Concurrent License:
9324-RLD300xxF
9324-RLD300NXxxE Node Locked:
9324‑RLD600xxE
Concurrent License:¬ 
9324‑RLD600xxF
Node Locked:
9324‑RLD700NXxxE
Concurrent License:¬ 
9324‑RLD700NXxxF
RSLinx Classic software Lite included Lite included Lite included Lite included Lite included Lite included Lite included
RSNetWorx ControlNet,
RSNetWorx DeviceNet,
RSNetWorx EtherNet/IP
software T 
Available separately Available separately Available separately Available separately Included Available separately Included
FactoryTalk AssetCentre audit support Included Included Included Included Included Included Included
FuzzyDesigner
9324-RLDFZYENE ‡ 
NA Available separately Available separately Available separately Available separately Available separately Available separately
RSLogix Emulate 5000
9310-WED200ENE § 
Available separately NA NA Available separately Available separately Available separately Included
FactoryTalk
security server § 
Included Included Included Included Included Included Included
Security server emulator §  Included Included Included Included Included Included Included
RSLogix Architect
9326-LGXARCHENE Ø 
Available separately Available separately Available separately Available separately Available separately Available separately Included
FactoryTalk View SE demo
(50 tags/2 hours)
Available separately Available separately Available separately Available separately Available separately Available separately Included
¬ As of RSLogix 5000 programming software, version 16. The software is designed to grab the highest functionality license first. For example, if Standard, Full and Professional Concurrent licenses are available on the FactoryTalk Activation server, RSLogix 5000 software will grab the highest functionality license first.
T RSNetWorx for ControlNet software is 9357-CNETL3. RSNetWorx for DeviceNet software is 9357-DNETL3. RSNetWorx for EtherNet/IP software is 9357-ENETL3. They are available together as 9357-ANETL3.
‡ As of RSLogix 5000 programming software, version 16.
§ RSLogix Emulate 5000 software does not support Microsoft Windows Vista at this time.
§ FactoryTalk AP install required - included on disk.
Ø As of RSLogix 5000 programming software, version 15.

Product Overview

Click to enlarge - RSLinxIcon_4C

RSLinx Software

RSLinx software is a complete communication server providing plant-floor device connectivity for a wide variety of software applications. In addition, several open interfaces are provided for third-party HMI, data collection and analysis packages, and custom client-application software.

RSLinx software, version 2.x, is joined by RSLinx Enterprise software, another product within the RSLinx family that provides unparalleled connectivity to Logix processors. RSLinx Enterprise software works as a data server.


Click to enlarge - RSLinxScreen_GS


RSLinx Software Requirements

RSLinx software can be used with these operating systems:


In most cases, RSLinx Lite software comes bundled with controller programming software packages.

You can also download RSLinx Lite for free from the Software Updates link on the Get Support Now website at http://support.rockwellautomation.com


RSLinx Software Packages

Cat. No. RSLinx Products
Available only bundled with other products such as RSLogix software products. RSLinx Lite
9355-WABSNENE RSLinx Single Node
9355-WABOEMENE RSLinx OEM
9355-WABGWENE RSLinx Gateway
9355-RSLETENE RSLinx Enterprise
  

Product Overview

Click to enlarge - RSNetWorxSoftwareIcon_BW

RSNetWorx Software

RSNetWorx software is the configuration tool for your control network. With RSNetWorx software you can create a graphical representation of your network configuration and configure the parameters that define your network.

Use RSNetWorx software for:



Click to enlarge - RSNetWorxCNetScreen_GS


Click to enlarge - RSNetWorxDNIScreen_GS


RSNetWorx Software Requirements

RSNetWorx software can be used with these operating systems:


In some cases, RSNetWorx software comes bundled with controller programming software packages.

RSNetWorx Software Packages

Cat. No. Description
9357-CNETL3 RSNetWorx for ControlNet software
9357-DNETL3 RSNetWorx for DeviceNet software
9357-ENETL3 RSNetWorx for Ethernet/IP software
9357-ANETL3 RSNetWorx for ControlNet, Ethernet/IP and DeviceNet software
9357-CNETMD3E
RSNetWorx for ControlNet software with MD, includes DriveExecutive Lite software
9357-DNETMD3E
RSNetWorx for DeviceNet software with MD
9357-ENETMD3E
RSNetWorx for EtherNet/IP software with MD
9357-ANETMD3E RSNetWorx for ControlNet, DeviceNet, and Ethernet/IP software with MD
  

Product Overview

Click to enlarge - RSEmulateIcon_GS

RSLogix Emulate 5000 Software

RSLogix Emulate 5000 software (9310-WED200ENE) is the emulation package for the Logix5000 controllers. RSLogix Emulate 5000 software, used in conjunction with RSLogix 5000 software, lets you run and debug your application code while at your computer. In addition, RSLogix Emulate 5000 software lets you test HMI screens, developed in FactoryTalk View SE software for example, without the need to connect to a real controller.

You can set tracepoint and breakpoint instructions (ladder diagram only) in your application code, use traces, and also vary the execution speed of the emulator. RSLogix Emulate 5000 software supports all the programming languages (ladder diagram, function block diagram, structured text, and sequential function chart). RSLogix Emulate 5000 software does not allow for control of real I/O.

Use RSLogix Emulate software for:



Click to enlarge - RSEmulateChassisScreen_GS


RSLogix Emulate 5000 Requirements

Description Value
Personal computer IBM-compatible Intel Pentium II 300 MHz or Celeron 300A
(Pentium III 600 MHz recommended)
Operating system Supported operating systems:
• Microsoft Windows XP with Service Pack 1or later
• Microsoft Windows 2000 with Service Pack 2 or later
• Microsoft Windows NT version 4.0 with Service Pack 6A or later
RAM 128 MB of RAM min
Hard disk space 50 MB of free hard disk space
Video requirements 16-color VGA graphics display
800 x 600 or greater resolution
  

RSLogix Emulate 5000 software is included with RSLogix 5000 Professional software.