Control Transformers

Catalogs > Industrial Controls Catalog > Power Supplies > Control Transformers > Bulletin 1497D — General Purpose Transformers, 1-Phase

Bulletin 1497D — General Purpose Transformers, 1-Phase

Introduction Standards Compliance and Certifications Catalog Number Explanation Product Selection Approximate Dimensions
Product Selection

208V Primary with No Taps

Secondary — 120/240V
Click to enlarge - 1497_DiagramE1E
Primary — 208V
Winding Voltage Accuracy [V] Connect Line
Primary 208 H1-H2
Secondary 240 X2-X3 H1-H4
240/120¬  X2-X3 X1-X3-X4
120 X1X3-X2X4 X1-X4
  
¬ Three wire operation

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Cat. No.
0.050 60 115 (239) 1497D-A1-M20-0-N
0.075 1497D-A2-M20-0-N
0.100 1497D-A3-M20-0-N
0.150 1497D-A4-M20-0-N
0.250 1497D-A6-M20-0-N
0.500 1497D-A9-M20-0-N
0.750 1497D-A10-M20-0-N
1.0 1497D-A11-M20-0-N
1.5 1497D-A12-M20-0-N
2.0 1497D-A13-M20-0-N
3.0 1497D-A14-M20-0-N
5.0 1497D-A15-M20-0-N
7.5 1497D-A16-M20-0-N
10.0 1497D-A17-M20-0-N
15.0 1497D-A18-M20-0-N
25.0 1497D-A20-M20-0-N
  

240x480V Primary with No Taps

Secondary — 120/240V
Click to enlarge - 1497_DiagramA
Primary — 240x480V
Winding Voltage Accuracy [V] Connect Line
Primary 480 H2-H3 H1-H4
240 H1H3-H2H4 H1-H4
Secondary 240 X2-X3 H1-H4
240/120¬  X2-X3 X1-X3-X4
120 X1X3-X2X4 X1-X4
  
¬ Three wire operation

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Cat. No.
0.050 60 115 (239) 1497D-A1-M10-0-N
50/60 1497D-A1-M14-0-N
0.075 60 1497D-A2-M10-0-N
50/60 1497D-A2-M14-0-N
0.100 60 1497D-A3-M10-0-N
50/60 1497D-A3-M14-0-N
0.150 60 1497D-A4-M10-0-N
50/60 1497D-A4-M14-0-N
0.250 60 1497D-A6-M10-0-N
50/60 1497D-A6-M14-0-N
0.500 60 1497D-A9-M10-0-N
50/60 1497D-A9-M14-0-N
0.750 60 1497D-A10-M10-0-N
50/60 1497D-A10-M14-0-N
1.0 60 1497D-A11-M10-0-N
50/60 1497D-A11-M14-0-N
1.5 60 1497D-A12-M10-0-N
50/60 1497D-A12-M14-0-N
2.0 60 1497D-A13-M10-0-N
50/60 1497D-A13-M14-0-N
3.0 60 1497D-A14-M10-0-N
50/60 1497D-A14-M14-0-N
5.0 60 1497D-A15-M10-0-N
50/60 1497D-A15-M14-0-N
7.5 60 1497D-A16-M10-0-N
50/60 1497D-A16-M14-0-N
10.0 60 1497D-A17-M10-0-N
50/60 1497D-A17-M14-0-N
15.0 60 1497D-A18-M10-0-N
50/60 1497D-A18-M14-0-N
25.0 60 1497D-A20-M10-0-N
50/60 1497D-A20-M14-0-N
  

480V Primary with No Taps

Secondary — 120/240V
Click to enlarge - 1497_DiagramE1E
Primary — 480V
Winding Voltage Accuracy [V] Connect Line
Primary 480 H1-H2
Secondary 240 X2-X3 H1-H4
240/120¬  X2-X3 X1-X3-X4
120 X1X3-X2X4 X1-X4
  
¬ Three wire operation

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Cat. No.
0.050 60 115 (239) 1497D-A1-M21-0-N
0.075 1497D-A2-M21-0-N
0.100 1497D-A3-M21-0-N
0.150 1497D-A4-M21-0-N
0.250 1497D-A6-M21-0-N
0.500 1497D-A9-M21-0-N
0.750 1497D-A10-M21-0-N
1.0 1497D-A11-M21-0-N
1.5 1497D-A12-M21-0-N
2.0 1497D-A13-M21-0-N
3.0 1497D-A14-M21-0-N
5.0 50/60 115 (239) 1497D-A15-M22-0-N
7.5 1497D-A16-M22-0-N
10.0 1497D-A17-M22-0-N
15.0 1497D-A18-M22-0-N
25.0 1497D-A20-M22-0-N
  

Secondary — 208V
Click to enlarge - 1497_Diagram14_flipped
Primary — 480V

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Cat. No.
0.050 60 115 (239) 1497D-A1-M24-0-N
0.075 1497D-A2-M24-0-N
0.100 1497D-A3-M24-0-N
0.150 1497D-A4-M24-0-N
0.250 1497D-A6-M24-0-N
0.500 1497D-A9-M24-0-N
0.750 1497D-A10-M24-0-N
1.0 1497D-A11-M24-0-N
1.5 1497D-A12-M24-0-N
2.0 1497D-A13-M24-0-N
3.0 1497D-A14-M24-0-N
5.0 1497D-A15-M24-0-N
7.5 1497D-A16-M24-0-N
10.0 1497D-A17-M24-0-N
15.0 1497D-A18-M24-0-N
25.0 1497D-A20-M24-0-N
  

480V Primary with Two 5% Taps Below Rated Primary Volts

Secondary — 120/240V
Click to enlarge - 1497_DiagramF1F
Primary — 480V
Winding Voltage Accuracy [V] Connect Line
Primary 480 H1-H4
456 H2-H4
432 H2-H3
Secondary 240 X2-X3 H1-H4
240/120¬  X2-X3 X1-X3-X4
120 X1X3-X2X4 X1-X4
  
¬ Three wire operation

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Tap Quantity Cat. No.
0.250 50/60 115 (239) (2) 5% FCBN 1497D-A6-M22-0-2
0.500 1497D-A9-M22-0-2
0.750 1497D-A10-M22-0-2
1.0 60 1497D-A11-M21-0-2
50/60 1497D-A11-M22-0-2
1.5 60 1497D-A12-M21-0-2
50/60 1497D-A12-M22-0-2
2.0 60 1497D-A13-M21-0-2
50/60 1497D-A13-M22-0-2
3.0 60 1497D-A14-M21-0-2
50/60 1497D-A14-M22-0-2
5.0 60 1497D-A15-M21-0-2
7.5 1497D-A16-M21-0-2
10.0 1497D-A17-M21-0-2
15.0 1497D-A18-M21-0-2
25.0 1497D-A20-M21-0-2
  

480V Primary with Two 2.5% Taps Above & Two 2.5% Below Rated Primary Volts

Secondary — 120/240V
Click to enlarge - 1497_DiagramG1G
Primary — 480V
Winding Voltage Accuracy [V] Connect Line
Primary 504 H1-H5
492 H1-H4
480 H1-H3
468 H2-H4
456 H2-H3
Secondary 240 X2-X3 H1-H4
240/120¬  X2-X3 X1-X3-X4
120 X1X3-X2X4 X1-X4
  
¬ Three wire operation

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Tap Quantity Cat. No.
3.0 60 115 (239) (2) 2.5% FCAN
(2) 2.5% FCBN
1497D-A14-M21-0-22
5.0 1497D-A15-M21-0-22
7.5 1497D-A16-M21-0-22
10.0 1497D-A17-M21-0-22
15.0 1497D-A18-M21-0-22
25.0 1497D-A20-M21-0-22
  

600V Primary with No Taps

Secondary — 120/240V
Click to enlarge - 1497_DiagramE1E
Primary — 600V
Winding Voltage Accuracy [V] Connect Line
Primary 600 H1-H2
Secondary 240 X2-X3 H1-H4
240/120¬  X2-X3 X1-X3-X4
120 X1X3-X2X4 X1-X4
  
¬ Three wire operation

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Cat. No.
0.050 60 115 (239) 1497D-A1-M11-0-N
0.075 1497D-A2-M11-0-N
0.100 60 1497D-A3-M11-0-N
50/60 1497D-A3-M23-0-N
0.150 60 1497D-A4-M11-0-N
0.250 60 1497D-A6-M11-0-N
50/60 1497D-A6-M23-0-N
0.500 60 1497D-A9-M11-0-N
50/60 1497D-A9-M23-0-N
0.750 60 1497D-A10-M11-0-N
50/60 1497D-A10-M23-0-N
1.0 60 1497D-A11-M11-0-N
1.5 1497D-A12-M11-0-N
2.0 1497D-A13-M11-0-N
3.0 1497D-A14-M11-0-N
5.0 1497D-A15-M11-0-N
7.5 1497D-A16-M11-0-N
10.0 1497D-A17-M11-0-N
15.0 1497D-A18-M11-0-N
25.0 1497D-A20-M11-0-N
  

600V Primary with Two 5% Taps Below Rated Primary Volts

Secondary — 120/240V
Click to enlarge - 1497_DiagramF1F
Primary — 600V
Winding Voltage Accuracy [V] Connect Line
Primary 600 H1-H2
570 H1-H3
540 H2-H3
Secondary 240 X2-X3 H1-H4
240/120¬  X2-X3 X1-X3-X4
120 X1X3-X2X4 X1-X4
  
¬ Three wire operation

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Tap Quantity Cat. No.
0.250 50/60 115 (239) (2) 5% FCBN 1497D-A6-M23-0-2
0.500 1497D-A9-M23-0-2
1.0 60 1497D-A11-M11-0-2
50/60 1497D-A11-M23-0-2
1.5 60 1497D-A12-M11-0-2
2.0 1497D-A13-M11-0-2
3.0 60 1497D-A14-M11-0-2
50/60 1497D-A14-M23-0-2
5.0 60 1497D-A15-M11-0-2
7.5 1497D-A16-M11-0-2
10.0 1497D-A17-M11-0-2
  

Secondary — 120/240V
Click to enlarge - 1497_DiagramG1G
Primary — 600V
Winding Voltage Accuracy [V] Connect Line
Primary 600 H1-H5
585 H1-H4
570 H1-H3
555 H2-H4
540 H2-H3
Secondary 240 X2-X3 X1-X4
240/120¬  X2-X3 X1-X3-X4
120 X1X3-X2X4 X1-X4
  
¬ Three wire operation

Continuous kVA Frequency [Hz] Temp. Rise
[°C (°F)]
Tap Quantity Cat. No.
15.0 60 115 (239) (4) 2.5% FCBN 1497D-A18-M11-0-4
25.0 1497D-A20-M11-0-4