1609-S Industrial
| Introduction | Standards Compliance and Certifications | Catalog Number Explanation | Product Selection | Accessories | Specifications | Approximate Dimensions and Shipping Weights |
| 1609-S350NS | 1609-S350ES | ||
| Input | Wiring | Touch-proof terminal block | |
| Nominal Voltage | 120V | 208/230V | |
| Voltage Range, Default | 81…143V | 160…287V | |
| Voltage Range, Widest, On Line | 75…153V | 150…300V | |
| Nominal Current | 2.9 A | 1.5 A | |
| Capacity | 350VA/280 W | ||
| Frequency | 47…63 Hz | ||
| PFC | None, load power factor is reflected in the input line current | ||
| On Line Output | Wiring | Touch-proof terminal block | |
| Nominal Voltage | 120V | 208/230V | |
| Voltage Range, Default | 106…127V | 208…253V | |
| Voltage Range, Widest, On Line | 97…136V | 196…265V | |
| Transfer Point Accuracy | +/- (2% of transfer voltage + 1.3) | +/- (2% of transfer voltage + 2.6) | |
| Overload Protection | Alarm at 107% of rated load input circuit breaker | Alarm at 107% of rated load Premises branch protection 10 A or less |
|
| Efficiency | 96% @ 100% resistive load | ||
| Surge Protection | Per EN50091-2 | ||
| On Battery Output | Frequency | Nominal +/- 3 Hz (Locked), Nominal +/- 0.5 Hz (Free-running) | |
| THD | < 5% at full (linear) load | ||
| Voltage Regulation | +/- 5%, + 5…-15% after low battery warning | ||
| Crest Factor | 2.5:1 | ||
| Efficiency | 77% @ 100% resistive load | ||
| Overload Protection | Overload indication and shutdown @ 107% of rate load or electronic current limit and shutdown under short circuit condition | ||
| Battery Pack | Run Time | 12 minutes (full load) 24 minutes (50% full load) |
|
| Type | Sealed lead acid, valve-regulated hot-swappable, user-replaceable | ||
| Voltage | 24V | ||
| Charger | Temperature-compensated, current-limited, float charger | ||
| Recharge Time | Less than 3 hours to 90% capacity | ||
| Lifetime | 3…5 years @ 25 °C ambient Lifetime cut in half for every 10 °C above 25 °C |
||
| Environment | Temperature | 0…40 °C (operating), -15…45 °C (short-term storage) | |
| Altitude | 10 000 ft (operating) | ||
| Humidity | 0…95% non-condensing (operating) | ||
| Heat Output | On line, full load: 137 BTU per hour On line, full load, charging: 190 BTU per hour On battery, full load: 1706 BTU per hour |
||
| Audible Noise | <45 dB @ 1 m (full load) | ||
| Communication | Serial | Serial RS232 DB-9 | |
| Options | Dry contact I/O communication cable | ||
| Indicators and Controls | Status LEDs | On line (green) AVR low line (yellow) AVR high line (yellow) On battery (yellow) Overload and fault (red) Bad battery (red) Load percentage of full rating bar graph (green) Battery state of charge bar graph (green) Measured input voltage indicated by load bar graph when recessed switch is held |
|
| Control Buttons | On/self-test/alarm silence/cold start Output off |
||
| Audible Alarms | On Battery: 4 short beeps repeats about 20 seconds (mute capability) Low Battery: persistent 0.5 second beep every 1 second (mute capability) Disconnected Battery: continual chirping Failure: continuous tone Replace Battery: occasional On/off change: single beep |
||