Modifications are ordered by adding the appropriate modification suffix code to the catalog number of the basic device. Add suffix codes to the catalog number in descending order.

Modifications

Lockout Solenoid
Description Coil Voltage AC Hz Suffix Code
In some applications, an accidental turn of the shaft may close the contacts and jog or start the motor. To guard against this, Bulletin 808 Speed Switches can be equipped with a lockout solenoid, which mechanically restrains the contacts from operating until the lockout coil is energized. To order, select a suffix code to identify the operating voltage and frequency of the lockout coil. Add the suffix code to the catalog number before any other modifications. 24 60 LA24
110/120 50/60 LA1
208 60 LA20
220/240 50/60 LA2
440/480 50/60 LA4
550/600 50/60 LA6
  

Speed Switch without External Shaft Bearing Seal
Description Suffix Code
The external bearing seal can be omitted at the factory if it causes mechanical mounting interference. Omitting the external seal will increase the usable shaft length from 1.05" (26.7 mm) to 1.38" (35 mm) permitting mounting the speed switch directly to an end bell housing. To order device without the external seal, add suffix code W5 to the end of the catalog number after all other modifications.
W5
  

Speed Switch with Bottom Conduit Opening
Description Suffix Code
In addition to the standard conduit openings on each side, an additional opening at the bottom can be supplied. To order, add Suffix Code X1 to the basic catalog number. Note: Not available for Type 7 & 9 enclosures. X1
  

Ordering Accessories

Accessories are ordered as separate catalog numbers. Select the appropriate accessories from the tables below.

Accessories

Replacement Bearing Seal
Type Cat. No.
Replacement Bearing Seal 808-N5
  

Mounting Brackets
Type Cat. No.
Base Mounting 808-N1
3-Point Flange 808-N2
4-Point Flange 808-N3
  

Lockout Solenoid Kit
Description Cat. No.
To order a Lockout Solenoid Kit, add the appropriate lockout solenoid suffix code (see Lockout Solenoid table under Modifications) to Cat. No. 808-N_. Example: to order a Lockout Solenoid Kit for a device operating at 110/120V AC, 50/60 Hz, the complete Cat. No. is 808-NLA1. 808-N_