Bulletin 800MR/800MB Push Buttons
| Product Overview |
|
Bulletin 800MR
Build a Catalog Number
- 22.5 mm mounting hole
- Type 13 oiltight
- Round operators
| Product Overview |
|
Bulletin 800MB
Build a Catalog Number
- 22.5 mm mounting hole
- Type 13 oiltight
- Square backlit operators
Certifications
UL Listed —File: E14840,
E10314
Guide: NKCR, NOIV
CSA Certified: LR1234, LR11924
IEC Compliance, IEC 529
Bul. 800MR Product Selection - Momentary Contact Push Buttons
Momentary Contact Push Button Units, Non-Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
||
| Flush Head Unit Cat. No. 800MR-A1B |
Extended Head Unit Cat. No. 800MR-B2A |
Mushroom Head Unit Cat. No. 800MR-D2B |
Momentary Contact Push Button Units, Non-Illuminated
|
| 800MR | | A | 1 | A | ||||
| a | b | c | d |
| a | b | c | d | |||||||
| Operator Type⋆ | Button Color | Standard Contact Cartridges | Contact Block Termination Type |
|||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||
| A | Flush head | 1 | Green | Blank | No contacts | Blank | Stab terminals | |||
| B | Extended head | 2 | Black | A | 1 N.O. - 1 N.C. | K | Large screw | |||
| D | Mushroom head | 3 | Orange | A2 | 2 N.O. | |||||
| 4 | Grey | A3 | 1 N.O.E.M. - 1 N.C.L.B. | |||||||
| 5 | White | A4 | 2 N.C. | |||||||
| 6 | Red | A7 | 1 N.C.L.B. - 1 N.C. | |||||||
| 7 | Blue | B | 2 N.O. - 2 N.C. | |||||||
| 9 | Yellow | D1 | 1 N.O. | |||||||
| D2 | 1 N.C. | |||||||||
⋆ Guards must be ordered separately.
Logic Reed and small screw blocks can be ordered separately.
Momentary Contact Push Button Units, Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
||
| Flush Head Unit Cat. No. 800MR-QA24GA |
Extended Head Unit Cat. No. 800MR-PB16RA |
Mushroom Head Unit Cat. No. 800MR-QMB24RA |
Momentary Contact Push Button Units, llluminated
| 800MR | | PA | L | 24 | R | |||||||
| a | b | c | d | e | f |
| a | b | c | d | e | f | |||||||||||
| Operator | Illumination Options | Input Voltage | Lens Color | Standard Contact Cartridges | Contact Block Termination Type♠ |
|||||||||||
| Transformer | Full Voltage | |||||||||||||||
| Code | Description | Code | Description | Code | Description | Code | Color | Code | Description | Code | Description | |||||
| PA | Flush♦ | Blank | Standard illumination as determined by power module type | 12 | 12V AC/DC | A | Amber | Blank | No contacts | Blank | Stab terminals | |||||
| PB | Extended | L | LED§ | 24 | 24V AC/DC | B | Blue | A | 1 N.O. - 1 N.C. | K | Large screw | |||||
| PMB | Mushroom | 10 | 120V AC♣ | C | Clear | A2 | 2 N.O. | |||||||||
| Full Voltage | Transformer | G | Green | A3 | 1 N.O.E.M. - 1 N.C.L.B. | |||||||||||
| Code | Description | Code | Description | R | Red | A4 | 2 N.C. | |||||||||
| QA | Flush♦ | 16 | 120V AC 50/60 Hz | W | White | A7 | 1 N.C.L.B. - 1 N.C. | |||||||||
| QB | Extended | 26 | 240V AC 50/60 Hz | X | No lens with contact blocks | B | 2 N.O. - 2 N.C.∆ | |||||||||
| QMB | Mushroom | Blank | No lens without contact blocks | D1 | 1 N.O. | |||||||||||
| D2 | 1 N.C. | |||||||||||||||
§ LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED.
♣ Only available with LED Illumination option.
∆ Only available with full voltage power module option and standard stab terminations.
♦ Guards must be ordered separately.
♠ Logic Reed and small screw blocks must be ordered separately.
Bul. 800MR Product Selection - Push‑Pulls
2-Position Push-Pull and Push-Pull/Twist Release Units, Non-Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| 2-Position Push-Pull Cat. No. 800MR-FX6A |
2-Position Push-Pull/Twist Cat. No. 800MR-FXT6A4 |
3-Position Push-Pull Units, Non-Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
2-Position Push-Pull and Push-Pull/Twist Release and 3-Position Push-Pull Units, Non-Illuminated
| 800MR | | FX | T | 6 | A | |||||||
| a | b | c | d | e | f |
(2-Position)
| 800MR | | FX | N | 6 | A | |||||||
| a | b1 | c | d | e | f |
(3-Position)
|
| d | e | f | |||||
| Button Color | Contact Cartridges | Contact Block Termination Type | |||||
| Code | Description | Code | Description | ||||
| Code | Color | Blank | No contacts | Blank | Stab terminals | ||
| 1 | Green | A | 1 N.O. - 1 N.C. | K | Large screw | ||
| 2 | Black | A2 | 2 N.O. | ||||
| 3 | Orange | A4 | 2 N.C. | ||||
| 4 | Grey | A7 | 1 N.C.L.B. - 1 N.C. | ||||
| 5 | White | B | 2 N.O. - 2 N.C. | ||||
| 6 | Red | D1 | 1 N.O. | ||||
| 7 | Blue | D2 | 1 N.C. | ||||
| 9 | Yellow | Note: See Table 1 for Target description. | |||||
| Blank | No cap | ||||||
Table 1. Target Selection
Note:X = Closed/O = Open
⋆ Not available in twist release.
Logic Reed and small screw blocks must be ordered separately.
2-Position Push-Pull and Push-Pull/Twist Release Units, Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Illuminated 2-Position Push-Pull Cat. No. 800MR-FXQ24RA |
Illuminated 2-Position Push-Pull/Twist Cat. No. 800MR-FXTP16RA |
3-Position Push-Pull Units, Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
2-Position Push-Pull and Push-Pull/Twist Release and 3-Position Push-Pull Units, Illuminated
| 800MR | | FX | T | P | 16 | R | A | |||||||||
| a | b | c | d | e | f | g | h |
(2-Position)
| 800MR | | FX | N | P | 16 | R | A | |||||||||
| a | b1 | c | d | e | f | g | h |
(3-Position)
|
| e | f | g | h | |||||||
| Voltage | Button Color | Contact Cartridges | Contact Block Termination Type∆ | |||||||
| Full Voltage | ||||||||||
| Code | Description | Code | Color | Code | Description | Code | Description | |||
| 12 | 12V AC/DC | A | Amber | Blank | No contacts | Blank | Stab terminals | |||
| 24 | 24V AC/DC | B | Blue | A | 1 N.O. - 1 N.C. | K | Large screw | |||
| 10 | 120V AC§ | C | Clear | A2 | 2 N.O. | |||||
| Transformer | G | Green | A4 | 2 N.C. | ||||||
| Code | Description | R | Red | A7 | 1.N.C.L.B. - 1 N.C. | |||||
| 16 | 120V AC 50/60 Hz | W | White⋆ | B | 2 N.O. - 2 N.C.♣ | |||||
| 26 | 240V AC 50/60 Hz | X | No cap | D1 | 1 N.O. | |||||
| D2 | 1 N.C. | |||||||||
| Note: See Table 1 for Target description. | ||||||||||
Table 2. Target Selection
Note:X = Closed/O = Open
⋆ Not available in twist release.
LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED.
§ Only available with LED Illumination option.
♣ Only available with full voltage power module option and standard stab terminations.
∆ Logic Reed and small screw blocks must be ordered separately.
Bul. 800MR Product Selection - Selector Switches
2-Position Selector Switch Units, Non-Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Standard Knob Operator Cat. No. 800MR-HH2BLA |
Knob Lever Operator Cat. No. 800MR-HK2BLA |
|
2-Position Selector Switch Units, Non-Illuminated
| 800MR | | H | H | 2 | B | L | A | |||||||
| a | b | c | d | e | e1 | f |
(Selector Switch)
| 800MR | | H | 31 | B | L | A | ||||||||||
| a | b | c1 | c2 | d | e | e1 | f |
(Cylinder Lock)
|
| a | b | c | c1 | c2 | ||||||||||
| Operator Positions | Operator Color and Type§ | Operator Function | Operator Function/Locking Position⋆ | Key Codes | ||||||||||
| Standard Knob | Standard Knob | Maintained | Code | Key No. | Master Key | |||||||||
| Code | Description | Code | Description | Code | Description | Code | Description | Blank | T100 (standard) | 1T | ||||
| H | 2-position selector switch | X | No knob | 2 | Maintained | 31 | Lock in left | 02 | T101 | 1T | ||||
| H | 2-position cylinder lock | H | Black | 4 | Spring return from left | 32 | Lock in right | 03 | T102 | 1T | ||||
| Knob Lever | 5 | Spring return from right | 33 | Lock in both | 04 | T106 | 1T | |||||||
| Code | Description | Spring Return From Left | 05 | T107 | 1T | |||||||||
| X | No knob lever | Code | Description | 07 | T109 | 2T | ||||||||
| K | Black | 42 | Lock in right | 08 | T134 | 2T | ||||||||
| Cylinder Lock | Spring Return From Right | 09 | T135 | 2T | ||||||||||
| Code | Description | Code | Description | 10 | T136 | 2T | ||||||||
| Blank | Key | 48 | Lock in left | 14 | T147 | 2T | ||||||||
| d | e | e1 | f | ||||||||
| Cam Type | Contact Cartridge Position | Contact Cartridges | Contact Block Termination Type♣ | ||||||||
| Code | Description | Code | Description | Code | Description | Code | Description | ||||
| B | B cam | Blank | Both left and right | Blank | No contacts | Blank | Stab terminals | ||||
| L | Left | ∆ | A | 1 N.O. - 1 N.C. | K | Large screw | |||||
| ∆ | A2 | 2 N.O. | |||||||||
| ∆ | A4 | 2 N.C. | |||||||||
| ♦ | B | 2 N.O. - 2 N.C. | |||||||||
| ∆ | D1 | 1 N.O. | |||||||||
| ∆ | D2 | 1 N.C. | |||||||||
| ♦ | P1 | 3 N.O. | |||||||||
| ♦ | P2 | 3 N.C. | |||||||||
| ♦ | P3 | 2 N.O. - 1 N.C. | |||||||||
| ♦ | P4 | 2 N.C. - 1 N.O. | |||||||||
| ♦ | P5 | 4 N.O. | |||||||||
| ♦ | P6 | 4 N.C. | |||||||||
| ♦ | P7 | 3 N.O. - 1 N.C. | |||||||||
| ♦ | P8 | 1 N.O. - 3 N.C. | |||||||||
| Note:See Table 1 for Target arrangements | |||||||||||
Table 1. Selector Switch Cam Targets
3-Position Selector Switch Units, Non-Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Standard Knob Operator Cat. No. 800MR-JH2BB |
Knob Lever Operator Cat. No. 800MR-JK2BB |
|
3-Position Selector Switch Units, Non-Illuminated
|
| 800MR | | J | H | 2 | B | L | A | |||||||
| a | b | c | d | e | e1 | f |
(Selector Switch)
| 800MR | | J | 41 | B | L | A | ||||||||||
| a | b | c1 | c2 | d | e | e1 | f |
(Cylinder Lock)
| a | b | c | c1 | ||||||||
| Operator Positions | Operator Color and Type§ | Operator Function | Operator Function/Locking Position⋆ | ||||||||
| Standard Knob | Description | Knob Lever | Maintained | ||||||||
| Code | Description | Code | Code | Code | Description | Code | Description | ||||
| J | 3-position selector switch | X | No knob | X | 2 | Maintained | 41 | Lock in left | |||
| J | 3-position cylinder lock | H | Black | K | 4 | Spring return from left | 42 | Lock in center | |||
| Blank | Key | Blank | 5 | Spring return from right | 43 | Lock in right | |||||
| 9 | Spring return from both | 44 | Lock in all positions | ||||||||
| 45 | Lock in left and center | ||||||||||
| 46 | Lock in right and left | ||||||||||
| 47 | Lock in right and center | ||||||||||
| Spring Return From Left | |||||||||||
| Code | Description | ||||||||||
| 50 | Lock in center | ||||||||||
| 52 | Lock in right | ||||||||||
| 51 | Lock in right and center | ||||||||||
| Spring Return From Right | |||||||||||
| Code | Description | ||||||||||
| 69 | Lock in left | ||||||||||
| 38 | Lock in center | ||||||||||
| 73 | Lock in left and center | ||||||||||
| Spring Return From Left and Right | |||||||||||
| Code | Description | ||||||||||
| 631 | Lock in center⋆ | ||||||||||
| c2 | d | e | e1 | f | |||||||||||
| Key Codes | Cam Type | Contact Cartridge Position | Contact Cartridges | Contact Block Termination Type♣ | |||||||||||
| 1T Master Series | Standard | Description | |||||||||||||
| Code | Key No. | Code | Description | Code | Description | Code | Left side | Right side | Code | Description | |||||
| Blank | T100 (standard) | B | B cam | Blank | Both left and right | Blank | No contacts | Blank | Stab terminals | ||||||
| 02 | T101 | K | K cam | L | Left | ∆ | A | 1 N.O.-1 N.C. | K | Large screw | |||||
| 03 | T102 | P | P cam | R | Right | ∆ | A3 | 1 N.O.E.M.-1 N.C.L.B. | |||||||
| 04 | T106 | U | U cam | ♦ | B | 1 N.O.-1 N.C. | |||||||||
| 05 | T107 | ♦ | P1 | 2 N.O. | 1 N.O. | ||||||||||
| 2T Master Series | ♦ | P2 | 2 N.C. | 1 N.C. | |||||||||||
| Code | Key No. | ♦ | P3 | 2 N.O. | 1 N.C. | ||||||||||
| 07 | T109 | ♦ | P4 | 2 N.C. | 1 N.O. | ||||||||||
| 08 | T134 | ♦ | P5 | 2 N.O. | 2 N.O. | ||||||||||
| 09 | T135 | ♦ | P6 | 2 N.C. | 2 N.C. | ||||||||||
| 10 | T136 | ♦ | P7 | 2 N.O. | 1 N.O. - 1 N.C. |
||||||||||
| 14 | T147 | ♦ | P8 | 2 N.C. | 1 N.O. - 1 N.C. |
||||||||||
| ♦ | P9 | 1 N.O. | 1 N.C. | ||||||||||||
| ♦ | T1 | 1 N.O. - 1 N.C. |
1 N.C. | ||||||||||||
Note:See Table 1 for cam and contact block selection.
⋆ Key removable in locked position only.
If no optional key code is specified, the standard key (T100) will be supplied.
§ Red, green, blue, yellow, orange, grey, and white non-illuminated selector switch knobs and lever knobs must be ordered separately.
♣ Logic Reed and small screw contact blocks must be ordered separately.
∆ Contact cartridge position code (Table e) must be L or R.
♦ Contact cartridge position code (Table e) must be --.
Table 1. Selector Switch Cam Targets
4-Position Selector Switch Units, Non-Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Standard Knob Operator Cat. No. 800MR-NH2QB |
Knob Lever Operator Cat. No. 800MR-NK2QB |
|
4-Position Selector Switch Units, Non-Illuminated
|
| 800MR | | N | H | 2 | Q | B | ||||||
| a | b | c | d | e | f |
(Selector Switch)
| 800MR | N | 31 | Q | B | ||||||||||
| a | b | c1 | c2 | d | e | f |
(Cylinder Lock)
| a | b | c | c1 | ||||||||
| Operator Positions | Operator Color and Type♣ | Operator Function | Operator Function/Locking Position⋆ | ||||||||
| Standard Knob | Description | Knob Lever | Standard Key | ||||||||
| Code | Description | Code | Code | Code | Description | Code | Description | ||||
| N | 4-position selector | X | No knob | X | 2 | Maintained | 31 | Lock in position 1 | |||
| N | 4-position cylinder lock | H | Black | K | 32 | Lock in position 2 | |||||
| Blank | Key | Blank | 33 | Lock in position 3 | |||||||
| 34 | Lock in position 4 | ||||||||||
| 41 | Lock in position 1-2 | ||||||||||
| 42 | Lock in position 1-3 | ||||||||||
| 43 | Lock in position 1-4 | ||||||||||
| 44 | Lock in position 2-3 | ||||||||||
| 45 | Lock in position 2-4 | ||||||||||
| 46 | Lock in position 3-4 | ||||||||||
| 51 | Lock in position 1-2-3 | ||||||||||
| 52 | Lock in position 1-2-4 | ||||||||||
| 53 | Lock in position 1-3-4 | ||||||||||
| 54 | Lock in position 2-3-4 | ||||||||||
| 61 | Lock in all positions | ||||||||||
♣ Red, green, blue, yellow, orange, grey, and white non-illuminated selector switch knobs and knob levers must be ordered separately.
⋆ Key removable in locked position only.
Operators are maintained in all positions.
§ If no optional key code is specified, the standard key (T100) will be supplied.
∆ Logic Reed and small screw contact blocks must be ordered separately.
2-Position Knob/Lever Type Selector Switch Units, Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Standard Knob Operator Cat. No. 800MR-24HA2BRA |
Knob Lever Operator Cat. No. 800MR-24HL2BRA |
3-Position Knob/Lever Type Selector Switch Units, Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Standard Knob Operator Cat. No. 800MR-24JA2BRA |
Knob Lever Operator Cat. No. 800MR-24JL2BRA |
2-Position and 3-Position Knob/Lever Type Selector Switch Units, Illuminated
|
| 800MR | | 24 | H | A | L | 2 | B | R | A | |||||||||
| a | b | c | d | e | f | g1 | g2 | h |
(2-Position)
| 800MR | | 24 | J | A | L | 2 | B | R | A | |||||||||
| a | b | c | d | e | f1 | g1 | g2 | h |
(3-Position)
| a | b | c | ||||||
| Input Voltage | Operator Positions | Operator Color and Type | ||||||
| Full Voltage | Standard Knob | Description | Knob Lever | |||||
| Code | Description | Code | Description | Code | Code | |||
| 12 | 12V AC/DC | H | 2-position | X | No knob | X | ||
| 24 | 24V AC/DC | J | 3-position | A | Red | L | ||
| 10 | 120V AC⋆ | B | Green | M | ||||
| Transformer | D | Amber | P | |||||
| Code | Description | Y | Clear | Z | ||||
| 16 | 120V AC 50/60 Hz | |||||||
| 26 | 240V AC 50/60 Hz | |||||||
| d | e | f | f1 | |||||||
| Illumination Options | Operator Function | Cam Type (2-Position) | Cam Type (3-Position) | |||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||
| Blank | Incandescent | 2 | Maintained | B | B cam | B | B cam | |||
| L | LED | 4 | Spring return from left | Note:For Target arrangements see Table 1. | K | K cam | ||||
| 5 | Spring return from right | P | P cam | |||||||
| 9 | Spring return from both | U | U cam | |||||||
| Note:For Target arrangements see Table 2. | ||||||||||
| g1 | g2 | h | |||||||
| Contact Cartridge Position | Contact Cartridges | Contact Block Termination Type♣ | |||||||
| Code | Description | Description | |||||||
| Blank | Both right and left | Code | Left side | Right side | Code | Description | |||
| R | Right | Blank | No contacts | Blank | Stab terminals | ||||
| ∆ | A | — | 1 N.O.-1 N.C. | K | Large screw | ||||
| ∆ ♠ | A2 | — | 2 N.O. | ||||||
| ∆ | A3 | — | 1 N.O.E.M.- 1 N.C.L.B. |
||||||
| ∆ ♠ | A4 | — | 2 N.C. | ||||||
| § ♦ | B | 1 N.O.-1 N.C. | 1 N.O.-1 N.C. | ||||||
| ∆ ♠ | D1 | — | 1 N.O. | ||||||
| ∆ ♠ | D2 | — | 1 N.C. | ||||||
| § ♦ | P1 | 2 N.O. | 1 N.O. | ||||||
| § ♦ | P2 | 2 N.C. | 1 N.C. | ||||||
| § ♦ | P3 | 2 N.O. | 1 N.C. | ||||||
| § ♦ | P4 | 2 N.C. | 1 N.O. | ||||||
| § ♦ | P5 | 2 N.O. | 2 N.O. | ||||||
| § ♦ | P6 | 2 N.C. | 2 N.C. | ||||||
| § ♦ | P7 | 2 N.O. | 1 N.O.-1 N.C. | ||||||
| § ♦ | P8 | 2 N.C. | 1 N.O.-1 N.C. | ||||||
| § ♦ | P9 | 1 N.O. | 1 N.C | ||||||
| § ♦ | T1 | 1 N.O.-1 N.C. | 1 N.C. | ||||||
| Note: See Table 1 for 2-position contact block selection. See Table 2 for 3-position contact block selection. |
|||||||||
⋆ Only available with LED Illumination option.
LEDs only available in red, green, amber and white. Knob color must match LED color, except clear knob supplied with white LED.
§ Only available with full voltage power module and standard stab terminations.
♣ Logic Reed and small screw contact blocks must be ordered separately.
∆ Contact cartridge position code (Table g1) must be R.
♦ Contact cartridge position code (Table g1) must be --.
♠ Only available for 2-position selector switches.
Table 1. Selector Switch Cam Targets
| Cam Description (2-Position) | |||
| B | |||
| Target | Operator Function | ||
|
|
|
Maintained and Spring Return From Right |
Spring Return From Left |
| X | O | N.C. | N.O. |
| O | X | N.O. | N.C. |
Note:X = Closed/O = Open
Table 2. Selector Switch Cam Targets
4-Position Knob/Lever Type Selector Switch Units, Illuminated
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Standard Knob Operator Cat. No. 800MR-24NA2QB |
Knob Lever Operator Cat. No. 800MR-24NL2QB |
4-Position Knob/Lever Type Selector Switch Units, Illuminated
|
| 800MR | | 24 | N | A | L | 2 | Q | B | ||||||||
| a | b | c | d | e | f | g | h |
(4-Position)
| a | b | c | d | ||||||||
| Input Voltage | Operator Positions | Operator Color and Type | Illumination Options | ||||||||
| Full Voltage | Standard Knob | Description | Knob Lever | ||||||||
| Code | Description | Code | Description | Code | Code | Code | Description | ||||
| 12 | 12V AC/DC | N | 4-position | X | No knob | X | Blank | Incandescent | |||
| 24 | 24V AC/DC | A | Red | L | L | LED§ | |||||
| 10 | 120V AC⋆ | B | Green | M | |||||||
| D | Amber | P | |||||||||
| Y | Clear | Z | |||||||||
Note:X = Closed/ O = Open
⋆ Only available with LED Illumination option.
Operator is maintained in all positions.
§ LEDs only available in red, green, amber and white. Knob color must match LED color, except clear knob supplied with white LED.
♣ Logic Reed contact blocks must be ordered separately.
Bul. 800MR Product Selection - Potentiometers, Pilot Lights, and Wobble Sticks
Potentiometer Operator Only
Description
This operator is suitable for mounting potentiometers or other small single turn rotary operated devices having 3/8 in. diameter bushings (1/4…3/8 in. long) and 1/4 in. diameter shaft (3/4…1-1/2 in. long), plus providing 600V electrical clearances to panel. Includes operator, instruction sheet, and graduated marking ring. This operator does not have a resistive potentiometer element.
|
| Type | Potentiometer |
| Cat. No. | |
| Operator Only (without Resistive Element) | 800MR-N37 |
Pilot Light Units
Contact Terminations
Operators come standard with stab terminations. To order large screw contact terminations for pilot lights add letter K to the end of the cat. no. For push-to-test pilot lights add the letter K.
|
|
|
| Pilot Light Cat. No. 800MR-Q24R |
Push-to-Test Pilot Light Cat. No. 800MR-QT24R |
| Lamp | Type | Volts | Color | Pilot Light | Push-to-Test | Dual Input | |
| Cat. No. | Cat. No. | Cat. No. | |||||
| Incandescent | Full Voltage | 12V AC/DC | Red | 800MR-Q12R | 800MR-QT12R | — | |
| Green | 800MR-Q12G | 800MR-QT12G | — | ||||
| Amber | 800MR-Q12A | 800MR-QT12A | — | ||||
| 24V AC/DC | Red | 800MR-Q24R | 800MR-QT24R | — | |||
| Green | 800MR-Q24G | 800MR-QT24G | — | ||||
| Amber | 800MR-Q24A | 800MR-QT24A | — | ||||
| Transformer⋆ | 120V AC 50/60 Hz | Red | 800MR-P16R | 800MR-PT16R | | 800MR-PDT16R | |
| Green | 800MR-P16G | 800MR-PT16G | | 800MR-PDT16G | |||
| Amber | 800MR-P16A | 800MR-PT16A | | 800MR-PDT16A | |||
| LED | Full Voltage | 24V AC/DC | Red | 800MR-QL24R | 800MR-QTL24R | — | |
| Green | 800MR-QL24G | 800MR-QTL24G | — | ||||
| Amber | 800MR-QL24A | 800MR-QTL24A | — | ||||
| 120V AC | Red | 800MR-QL10R | 800MR-QTL10R | — | |||
| Green | 800MR-QL10G | 800MR-QTL10G | — | ||||
| Amber | 800MR-QL10A | 800MR-QTL10A | — | ||||
| Transformer | 120V AC 50/60 Hz | Red | 800MR-PL16R | 800MR-PTL16R | — | ||
| Green | 800MR-PL16G | 800MR-PTL16G | — | ||||
| Amber | 800MR-PL16A | 800MR-PTL16A | — | ||||
| ⋆ Dual input transformer is transformer-relay type. | |||||||
| Comes standard with screw terminations. | |||||||
Pilot Light Units
| 800MR | | P | L | 24 | R | |||||
| a | b | c | d | e |
|
| a | b | c | |||||
| Operator | Illumination Options | Input Voltage | |||||
| Transformer | Full Voltage | ||||||
| Code | Description | Code | Description | Code | Description | ||
| P | Pilot light | Blank | Incandescent | 12 | 12V AC/DC | ||
| PDT | Pilot light — dual input transformer | L | LED | 24 | 24V AC/DC | ||
| PT | Pilot light — push-to-test | 10 | 120V AC§ | ||||
| Full Voltage | Transformer | ||||||
| Code | Description | Code | Description | ||||
| Q | Pilot light | 16 | 120V AC 50/60 Hz | ||||
| QT | Pilot light — push-to-test | 26 | 240V AC 50/60 Hz | ||||
| d | e | |||
| Lens Color | Contact Block Termination Type♣ | |||
| Pilot Lights | ||||
| Code | Color | Code | Description | |
| Blank | No lens | Blank | Stab terminals | |
| A | Amber | K | Large screw∆ | |
| B | Blue | Note:If large screw terminations are desired with a dual input transformer, (Cat. No. 800MR-PDT…), configurator space e must be left blank. | ||
| C | Clear | |||
| G | Green | |||
| R | Red | |||
| W | White | |||
LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED.
§ Only available with LED illumination option.
♣ Small screw contact blocks must be ordered separately.
∆ Only available with Push-to-test units.
Wobble Stick Units
Description
Designed for ease of operation. Wobble stick units have spring return action and may be operated from any angle. It is particularly useful with pendant stations.
Contact Terminations
Operators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations are sold separately.
|
| Contact Type | Cat. No. | Contact Type | Cat. No. | ||
|
|
1 N.O. - 1 N.C. | 800MR-M1A |
|
2 N.O. - 2 N.C. | 800MR-M1B |
|
|
|||||
Wobble Stick Units
|
| 800MR | | M1 | A | |||
| a | b | c |
| a | b | c | |||||
| Operator Type | Contact Cartridges | Contact Block Termination Type♦ | |||||
| Code | Description | Code | Description | Code | Description | ||
| M1 | Wobble stick | Blank | No contacts | Blank | Stab terminals | ||
| A | 1 N.O. - 1 N.C. | K | Large screw | ||||
| B | 2 N.O. - 2 N.C. | ||||||
♦ Logic Reed and small screw contact blocks must be ordered separately.
Bul. 800MB Product Selection
Momentary Contact Push Button Units, Non-Illuminated
Contact Terminations
Devices come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Flush Head Unit Cat. No. 800MB-CA1B |
Extended Head Unit Cat. No. 800MB-CB1B |
Momentary Contact Push Button Units, Non-Illuminated
|
| 800 | MB | | CA | 1 | A | ||||
| a | b | c | d | e |
| a | b | c | d | e | |||||||||
| Bezel Color | Operator Type | Color Insert | Contact Block(s) | Contact Block Termination Type§ |
|||||||||
| Standard | |||||||||||||
| Code | Color | Code | Description | Code | Color | Code | Description | Code | Description | ||||
| MB | Black | CA | Flush head | X | No color insert | Blank | No contacts | Blank | Stab terminals | ||||
| CB | Extended head | 1 | Green | D1 | 1 N.O. | K | Large screw | ||||||
| 3 | Orange | D2 | 1 N.C. | ||||||||||
| 4 | Grey | A | 1 N.O. - 1 N.C. | ||||||||||
| 5 | White | A2 | 2 N.O. | ||||||||||
| 6 | Red⋆ | A4 | 2 N.C. | ||||||||||
| 7 | Blue | A7 | 1 N.C.L.B. - 1 N.C. | ||||||||||
| 9 | Yellow | B | 2 N.O. - 2 N.C. | ||||||||||
⋆ Red flush head must be ordered separately.
Grey bezel can be ordered separately.
§ Logic Reed and small screw contact blocks must be ordered separately.
Momentary Contact Push Button Units, Illuminated
Contact Terminations
Devices come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
|
|
|
| Flush Head Unit Cat. No. 800MB-CPA16GA |
Extended Head Unit Cat. No. 800MB-CQB24RA |
Momentary Contact Push Button Units, Illuminated
|
| 800 | MB | | CQ | A | L | 06 | R | A | |||||||
| a | b | c | d | e | f | g | h |
| a | b | c | d | e | |||||||||
| Bezel Color | Power Module Type | Operator Type | Illumination Options | Voltage | |||||||||
| Full Voltage | |||||||||||||
| Code | Color | Code | Description | Code | Description | Code | Description | Code | Description | ||||
| MB | Black | CQ | Full voltage | A | Flush | Blank | Incandescent | 12 | 12V AC/DC | ||||
| CP | Transformer | B | Extended | L | LED§ ♣ | 24 | 24V AC/DC | ||||||
| 10 | 120V AC∆ | ||||||||||||
| Transformer | |||||||||||||
| Code | Description | ||||||||||||
| 16 | 120V AC | ||||||||||||
| 26 | 240V AC | ||||||||||||
| f | g | h | |||||
| Color Insert | Contact Block(s) | Contact Block Termination Type∇ |
|||||
| Standard | |||||||
| Code | Color | Code | Description | Code | Description | ||
| Blank | No contacts | Blank | No contacts | Blank | Stab terminals | ||
| X | Packet of colored inserts♦ | D1 | 1 N.O. | K | Large screw | ||
| A | Amber | D2 | 1 N.C. | ||||
| B | Blue | A | 1 N.O. - 1 N.C. | ||||
| C | Clear | A2 | 2 N.O. | ||||
| G | Green | A4 | 2 N.C. | ||||
| R | Red⋆ | A7 | 1 N.C.L.B. - 1 N.C. | ||||
| B | 2 N.O. - 2 N.C.♠ | ||||||
⋆ Red flush head push buttons are not suitable for applications requiring extended head or other unguarded buttons capable of being operated quickly in emergencies, and they may not comply with applicable codes or standards.
Grey bezels can be ordered separately.
§ LEDs are only available in red, green, amber, and white; lens color must match LED color.
♣ White LED available in 24V AC/DC only.
∆ LED only.
♦ Packet of colored inserts, one of each color. Not available with LED option for illuminated devices.
♠ Only available with full voltage illumination option and standard stab terminations.
∇ Logic Reed and small screw contact blocks must be ordered separately.
Dual Operator Momentary Contact Push Button Units, Non-Illuminated
Contact Terminations
Devices come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.
Contacts
Operators are supplied as standard with 2 N.O. - 2 N.C. contacts.
|
Dual Operator Momentary Contact Push Button Units, Non-Illuminated
|
| 800 | MB | | DB16 | B | ||||||
| a | b | c | d | e |
| a | b | c | d | e | |||||||||
| Bezel Color⋆ | Operator Type | Contact Blocks | Contact Block Termination Type | Legend Options | |||||||||
| Standard | |||||||||||||
| Code | Description | Code | Description | Code | Description | Code | Description | Code | Description | ||||
| MB | Black | DB16 | Dual push button unit Upper — Flush green Lower — Extended red |
Blank | No contact | Blank | Stab terminals | Blank | Upper — Blank Lower— Blank |
||||
| B | 2 N.O. - 2 N.C. | K | Large screw | 50 | Upper — ON Lower— OFF |
||||||||
| 64 | Upper — START Lower— STOP |
||||||||||||
⋆ Grey bezels must be ordered separately.
Logic Reed and small screw contact blocks must be ordered separately.
Pilot Light Units
Contact Terminations
Devices come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. For push-to-test pilot lights, add the letter K.
|
|
|
| Pilot Light Cat. No. 800MB-CQ24RS |
Push-to-Test Pilot Light Cat. No. 800MB-CPT16G |
| Lamp | Type | Volts | Color | Pilot Light | Push-to-Test |
| Cat. No. | Cat. No. | ||||
| Incandescent | Full voltage | 24 AC/DC | Red | 800MB-CQ24R | 800MB-CQT24R |
| Green | 800MB-CQ24G | 800MB-CQT24G | |||
| Amber | 800MB-CQ24A | 800MB-CQT24A | |||
| Transformer | 120 AC 50/60 Hz |
Red | 800MB-CP16R | 800MB-CPT16R | |
| Green | 800MB-CP16G | 800MB-CPT16G | |||
| Amber | 800MB-CP16A | 800MB-CPT16A | |||
| LED | Full voltage | 12 AC/DC | Red | 800MB-CQL12R | 800MB-CQTL12R |
| Green | 800MB-CQL12G | 800MB-CQTL12G | |||
| Amber | 800MB-CQL12A | 800MB-CQTL12A | |||
| 24 AC/DC | Red | 800MB-CQL24R | 800MB-CQTL24R | ||
| Green | 800MB-CQL24G | 800MB-CQTL24G | |||
| Amber | 800MB-CQL24A | 800MB-CQTL24A | |||
| Transformer | 120 AC 50/60 Hz |
Red | 800MB-CPL16R | 800MB-CPTL16R | |
| Green | 800MB-CPL16G | 800MB-CPTL16G | |||
| Amber | 800MB-CPL16A | 800MB-CPTL16A | |||
Pilot Light Units
| 800 | MB | | CP | L | 24 | R | |||||
| a | b | c | d | e | f |
|
| a | b | c | |||||
| Bezel Color♠ | Power Module Type | Illumination Options | |||||
| Code | Color | Code | Description | Code | Description | ||
| MB | Black | CP | Transformer | Blank | Incandescent | ||
| CQ | Full voltage | L | LED⋆ | ||||
| T | Push-to-test | ||||||
| TL | Push-to-test with LED⋆ | ||||||
| d | e | f | |||||
| Voltage | Lens Color | Termination Type∇ | |||||
| Full Voltage | Pilot Lights | ||||||
| Code | Description | Code | Color | Code | Description | ||
| 12 | 12V AC/DC | X | Packet of colored inserts♣ | Blank | Stab terminals | ||
| 24 | 24V AC/DC | A | Amber | Push-to-Test Pilot Lights | |||
| 10 | 120V AC§ | B | Blue | Code | Description | ||
| Transformer | C | Clear/white | Blank | Stab terminals | |||
| Code | Description | G | Green | K | Large screw∆ | ||
| 16 | 120V AC | R | Red | ||||
| 26 | 240V AC | ||||||
⋆ LEDs are only available in red, green, amber, and white; lens color must match LED color.
§ LED only.
♣ Packet of colored inserts, one of each color. Not available with LED illumination option.
∆ Only available with full voltage power module and standard stab terminations.
♠ Grey bezel can be ordered separately.
∇ Small screw contact blocks must be ordered separately.
Modifications and Accessories
Contact Blocks
Bulletin 800M contact blocks are available with quick connect type terminals and screw terminals with pressure plates (in two sizes). Each quick connect type termination will accept two 0.110 x 0.032 in. push-on connectors or one 0.250 x 0.032 in. connector. Each small screw terminal with pressure plate will accept a maximum of one #14 AWG wire or two #16 AWG wires. The large screw terminals with pressure plates are similar in size to the Bulletin 800T (full size) contact block terminals.
|
|
|
|
|||
| Cat. No. 800M-XA |
Cat. No. 800M-XAS |
Cat. No. 800M-XAK |
Cat. No. 800M-XAR |
| Contact Arrangement | Standard Block | Logic Reed Block | ||
| Quick Connect Terminals | Small Screw Terminals with Pressure Plates |
Large Screw Terminals with Pressure Plates |
Quick Connect Terminals | |
| Cat. No. | Cat. No. | Cat. No. | Cat. No. | |
| 1 N.O. | 800M-XD1 | 800M-XD1S | 800M-XD1K | 800M-XD1R |
| 1 N.C. | 800M-XD2 | 800M-XD2S | 800M-XD2K | 800M-XD2R |
| 1 N.O. - 1 N.C. | 800M-XA | 800M-XAS | 800M-XAK | 800M-XAR |
| 2 N.O. | 800M-XA2 | 800M-XA2S | 800M-XA2K | 800M-XA2R |
| 2 N.C. | 800M-XA4 | 800M-XA4S | 800M-XA4K | 800M-XA4R |
| 1 N.O.E.M. - 1 N.C.L.B. | 800M-XA3 | 800M-XA3S | 800M-XA3K | — |
| 1 N.C.L.B. - 1 N.C. | 800M-XA7 | 800M-XA7S | 800M-XA7K | — |
| Screw terminals with pressure plates are not available. | ||||
Note:For contact block rating information see Standard Contact Ratings.
Color Caps
Non-Illuminated Devices
|
|
|
|
|
||||
| Flush Head Push Buttons | Extended Head Push Buttons | Mushroom Buttons | Push-Pull Units | Twist or Pull Release Caps |
| Color | Flush Head Push Buttons |
Extended Head Push Buttons |
Mushroom Buttons | Push-Pull Units | Twist or Pull Release Caps |
| Cat. No. | Cat. No. | Cat. No. | Cat. No. | Cat. No. | |
| Green | 800MR-N41 | 800MR-N21 | 800MR-N56G | 800MR-N160B | 800MR-N30B |
| Black | 800MR-N42 | 800MR-N22 | 800MR-N56B | 800MR-N160H | 800MR-N30H |
| Orange | 800MR-N43 | 800MR-N23 | 800MR-N56O | 800MR-N160F | 800MR-N30F |
| Gray | 800MR-N44 | 800MR-N24 | 800MR-N56GR | 800MR-N160G | — |
| White | 800MR-N45 | 800MR-N25 | 800MR-N56W | 800MR-N160J | — |
| Red | 800MR-N46 | 800MR-N26 | 800MR-N56R | 800MR-N160A | 800MR-N30A |
| Blue | 800MR-N47 | 800MR-N27 | 800MR-N56BL | 800MR-N160C | 800MR-N30C |
| Yellow | 800MR-N49 | 800MR-N29 | 800MR-N56Y | 800MR-N160E | 800MR-N30E |
Illuminated Devices
|
|
|
|
|
||||
| Pilot Light | Push-to-Test Pilot Light and Illuminated Push Button |
Push-Pull Unit | Mushroom Button | Twist or Pull Release Caps |
| Color | Pilot Lights | Push-to-Test Pilots and Illuminated Push Buttons |
Illuminated Push-Pull Units |
Illuminated Mushroom Buttons |
Illuminated Twist or Pull Release Caps |
| Cat. No. | Cat. No. | Cat. No. | Cat. No. | Cat. No. | |
| Red | 800MR-N1R | 800MR-N2R | 800MR-N159R | 800MR-N156R | 800MR-N20R |
| Green | 800MR-N1G | 800MR-N2G | 800MR-N159G | — | 800MR-N20G |
| Amber | 800MR-N1A | 800MR-N2A | 800MR-N159A | 800MR-N156A | 800MR-N20A |
| Blue | 800MR-N1B | 800MR-N2B | 800MR-N159B | 800MR-N156B | 800MR-N20B |
| White | 800MR-N1W | 800MR-N2W | 800MR-N159W | 800MR-N156W | — |
| Clear | 800MR-N1C | 800MR-N2C | 800MR-N159C | 800MR-N156C | 800MR-N20C |
Replacement Selector Switch Knobs
|
|
|
|
|||
| Selector Knob Cat. No. 800MR-NG |
Selector Knob Lever Cat. No. 800MR-NK |
Selector Knob Cat. No. 800MR-LB |
Selector Knob Lever Cat. No. 800MR-LM |
Knobs
| Color | Selector Switch Knobs, Non-Illuminated | Color | Selector Switch Knobs, Illuminated | ||
| Standard Knob | Knob Lever | Standard Knob | Knob Lever | ||
| Cat. No. | Cat. No. | Cat. No. | Cat. No. | ||
| Gray | 800M-NG | 800M-NT | — | — | |
| Red | 800M-NA | 800M-NL | — | — | |
| Green | 800M-NB | 800M-NM | Red | 800M-LA | 800M-LL |
| Blue | 800M-NC | 800M-NN | Amber | 800M-LD | 800M-LP |
| Yellow | 800M-NE | 800M-NR | Clear | 800M-LY | 800M-LZ |
| Orange | 800M-NF | 800M-NS | Green | 800M-LB | 800M-LM |
| Black | 800M-NH | 800M-NK | — | — | |
| White | 800M-NJ | 800M-NV | — | — | |
Bul. 800MB Color Chip Kits
General Accessories
Boots
Miscellaneous
Miscellaneous, Continued
Miscellaneous, Continued
Replacement Lamps
Replacement Incandescent and Light Emitting Diode (LED) Lamps
All illuminated devices, except dual input transformer units, use T 1-3/4 wedge base units. Existing Bulletin 800M devices may have incandescent lamps replaced with shock and vibration resistant LEDs. Existing ANSI# 86, 73, or 85 lamps may be replaced by LEDs.
Bul. 800MR Legend Plates
|
|
|
| Standard Size Blank Legend Plate Gray (Cat. No. 800MR-W00) Red (Cat. No. 800MR-W600) |
Large Size Blank Legend Plate Gray (Cat. No. 800MR-W100) Red (Cat. No. 800MR-W6100) |
| Push Buttons/Pilot Lights | |||||
| Marking | Cat. No. | Marking | Cat. No. | Marking | Cat. No. |
| CLOSE | 800MR-W01 | LOWER | 800MR-W11 | SLOW | 800MR-W18 |
| DOWN | 800MR-W02 | OFF | 800MR-W09 | START | 800MR-W19 |
| EMERG. STOP (Red) | 800MR-W624 | ON | 800MR-W10 | STOP (Red) | 800MR-W620 |
| FAST | 800MR-W03 | OPEN | 800MR-W13 | TEST | 800MR-W21 |
| FORWARD | 800MR-W23 | OUT | 800MR-W12 | UP | 800MR-W22 |
| HIGH | 800MR-W04 | PUSH-TO-TEST | 800MR-W29 | 1ST SPEED | 800MR-W25 |
| IN | 800MR-W06 | RAISE | 800MR-W14 | 2ND SPEED | 800MR-W26 |
| INCH | 800MR-W07 | RESET | 800MR-W15 | 3RD SPEED | 800MR-W27 |
| JOG | 800MR-W08 | REV | 800MR-W16 | 4TH SPEED | 800MR-W28 |
| LOW | 800MR-W05 | RUN | 800MR-W17 | — | — |
| Selector Switches | |||||
| Marking | Cat. No. | Marking | Cat. No. | Marking | Cat. No. |
| OPEN-CLOSE | 800MR-W57 | STOP-START | 800MR-W64 | HAND-OFF-AUTO | 800MR-W78 |
| RAISE-LOWER | 800MR-W58 | SUM-WINT | 800MR-W65 | HIGH-LOW | 800MR-W53 |
| RUN-JOG | 800MR-W59 | UP-DOWN | 800MR-W66 | JOG-REV | 800MR-W54 |
| SAFE-RUN | 800MR-W60 | 1-2-3-4 | 800MR-W80 | JOG-RUN | 800MR-W55 |
| SLOW-FAST | 800MR-W61 | AUTO-OFF-HAND | 800MR-W79 | JOG-STOP-RUN | 800MR-W76 |
| SLOW-OFF-START | 800MR-W75 | FOR-OFF-REV | 800MR-W77 | LEFT-RIGHT | 800MR-W56 |
| START-JOG | 800MR-W62 | FOR-REV | 800MR-W51 | OFF-ON | 800MR-W50 |
| START-STOP | 800MR-W63 | HAND-AUTO | 800MR-W52 | — | — |
| Blank Legends | Custom Legends | ||
| Size — Color | Cat. No. | Number of Lines and Characters | Cat. No. |
| Standard — Gray | 800MR-W00 | 1 Line, 12 Characters | 800MR-W00E plus Custom Text |
| Large — Gray | 800MR-W100 | 2 Lines, 12 Characters | 800MR-W100E plus Custom Text |
| Standard — Red | 800MR-W600 | 1 Line, 12 Characters | 800MR-W600E plus Custom Text |
| Large — Red | 800MR-W6100 | 2 Lines, 12 Characters | 800MR-W6100E plus Custom Text |
Extra Large Legend Plates
An adapter ring is available for Bulletin 800MR push buttons when used with Bulletin 800T legend plates. Order Cat. No. 800MR-N50. Refer to Approximate Dimensions and Shipping Weights for dimension requirements.
|
|
|
|
|
||||
| Cat. No. 800MR-W645 |
Cat. No. 800MR-W646 |
Cat. No. 800MR-W647 |
Cat. No. 800MR-W130 |
Cat. No. 800MR-N50 |
| Format | Cat. No. | Format | Cat. No. |
| Large Size with Adapter Ring (Blank) | 800MR-W645 | For Push-Pull only Push Stop Pull Start |
800MR-W130 |
| Round with Adapter Ring (Blank) | 800MR-W646 | Adapter Ring⋆ Used with Bulletin 800T Legend Plates |
800MR-N50 |
| Pre-printed includes Adapter Ring (Cat. No. 800MR-N50) Push to Stop Twist or Pull Release |
800MR-W647 | — | — |
| ⋆ To use the Bulletin 800T legend plates with Bulletin 800MR devices, use adapter ring (Cat. No. 800MR-N50). | |||
Bul. 800MB Special Legend Inserts
Special legend inserts are available. To order, specify Cat. No. 800MS-WC00E and marking required. A maximum of nine characters per line: one or two lines 0.140 in. high characters; three or four lines 0.110 in. high characters.
Bul. 800MB Backlit Legends
The table lists standard legend markings that are available. To order legend insert only, add the suffix of the legend to Cat. No. 800MS-WC. Example: Cat. No. 800MS-WC03 would be a FAST legend insert only.
| Marking | Suffix | Marking | Suffix | Marking | Suffix | Marking | Suffix |
| CLOSE | 01 | LOW | 05 | RESET | 15 | UP | 22 |
| DOWN | 02 | LOWER | 11 | REV | 16 | 1ST SPEED | 25 |
| FAST | 03 | OFF | 09 | RUN | 17 | 2ND SPEED | 26 |
| FORWARD | 23 | ON | 10 | SLOW | 18 | 3RD SPEED | 27 |
| HIGH | 04 | OPEN | 13 | START | 19 | 4TH SPEED | 28 |
| IN | 06 | OUT | 12 | STOP | 20 | 0 | 40 |
| INCH | 07 | PUSH-TO-TEST | 29 | EMERG STOP | 24 | 1 | 41 |
| JOG | 08 | RAISE | 14 | TEST | 21 | — | — |
Specifications
Specifications⋆
| Electrical Ratings | ||
| Contact Ratings | Refer to the Contact Ratings tables below. | |
| Dielectric Strength | 1600V for one minute 1300V for one minute (Logic Reed) |
|
| Electrical Design Life Cycles | 750 000 at maximum rated load 200 000 at maximum rated load (Logic Reed) |
|
| Mechanical Ratings | ||
| Vibration | 10…2000 Hz 1.52 mm displacement (peak-to-peak) Max./10 G Max. (except Logic Reed) | |
| Shock | 1/2 cycle sine wave for 11 milliseconds ³ 25 G (contact fragility) and no damage at 100 G | |
| Degree of Protection | Type 13; IEC I44 IP65 Oiltight | |
| Mechanical Design Life Cycles | ||
| Push Buttons | 1 000 000 minimum | |
| Potentiometers | 100 000 minimum | |
| All other devices | 200 000 minimum | |
| Contact Operation | Contact blocks with Bifurcated spanner:Slow make and break, simple break. Logic Reed Contact Blocks:Snap-action |
|
| Typical Operating Forces | ||
| Operators without contact blocks | 2.45 lb (10.8 N) | |
| Push-Pull Units | 8 lb (35.3 N) push to in position 4 lb (17.7 N) maximum pull to out position |
|
| Contact Blocks | Standard — 1.5 lb (6.7 N) Logic Reed — 0.616 lb (2.6 N) |
|
| Environment | ||
| Temperature Range | Operating | 32…131 °F (0…55 °C) |
| Storage | -40…+185 °F (-40…+85 °C) | |
| Note:Operating temperatures at +32 °F (0 °C) are based on the absence of freezing moisture and liquids. | ||
| Humidity | 50% at 104 °F (40 °C) | |
| Panel Thickness Requirements | 1/16…1/4 in. (1.6…6.4 mm) | |
| ⋆ Performance Data — See Performance Data. | ||
Standard Contact Ratings
(IEC 337-1) (NEMA ICS 2-125) Maximum continuous current Ith 10 A. Bulletin 800M units have control circuit ratings with 800M contact blocks as follows:
| Maximum Operational Volts Ue |
Utilization Category | Rated Operational Currents | |||
| IEC | NEMA | Volts Ue | Make | Break | |
| AC 300 | AC-II | A300 | 120…300 | 7200 VA | 720 VA |
| 72…120 | 60 VA | 720 VA | |||
| 24…72 | 60 A | 10 A | |||
| For applications below 24V and 24 mA, Logic Reed contacts are recommended. | |||||
Logic Reed Contact Ratings
Maximum: 150V AC, 0.15 A, 8 VA and 30V DC, 0.06 A, 1.8 VA. Should only be used with resistive loads.
Wire Capacity
Stab Termination Contact Blocks —
Accepts two 0.110 x 0.032 in. push-on connectors or one 0.250 x 0.032 in. push-on connector.
Small Screw Contact Blocks —
Accepts one #14 or two #16 AWG solid or stranded wires.
Large Screw Termination Contact Blocks —
Accepts two #12 AWG solid or stranded wires.
Approximate Dimensions and Shipping Weights
Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bul. 800MR Extension in Front of Panel
Bul. 800MB Front View of Square Units
CAUTION: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction.
|
|
|
|
|||
| Unit without Insert and Backlit Unit |
Square Backlit with Guarded Bezel |
Square Backlit with Unguarded Bezel |
Dual Operator Unit |
Bul. 800MB Extension in Front of Panel
|
|
|
||
| Square Push Button Flush and Extended |
Square Push Button Large Extended |
Square Push Button Dual Operator |
Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Extension Behind Panel
|
Panel Depth Requirements —
1/16…1/4 in. (1.6…6.4 mm)
| Dimension A | |||||||||||||
| Description |
Push Button | Pilot Light | Sel. Switch | Cyl. Lock | Pot. | Push-Pull or Twist Release | Push Button | Pilot Light | Sel. Switch | Cyl. Lock | Pot. | Push-Pull or Twist Release | |
| Non-Illuminated | Units with Quick Connect Terminals | Units Having Small Screw Terminals with Pressure Plates | |||||||||||
| 2-1/4 (57.2) |
— — |
2-15/32 (62.7) |
3-1/2 (88.9) |
2-1/32 (51.6) |
2-3/4 (69.8) |
2-5/16 (59) |
— — |
2-17/32 (64.3) |
3-9/16 (90.5) |
2-1/32 (51.6) |
2-13/16 (71.4) |
||
| Illuminated | Full Voltage | 2-1/4 (57.2) |
2-1/4 (57.2) |
2-15/32 (62.7) |
— — |
— — |
2-3/4 (69.8) |
2-25/32 (70.6) |
2-25/32 (70.6) |
2-17/32 (64.3) |
— — |
— — |
2-13/16 (71.4) |
| Transformer | 2-23/32 (69.1) |
2-23/32 (69.1) |
2-29/32 (73.8) |
— — |
— — |
3-3/32 (78.6) |
2-25/32 (70.6) |
2-25/32 (70.6) |
2-31/32 (75.4) |
— — |
— — |
3-5/32 (80.1) |
|
| Non-Illuminated | Units Having Large Screw Terminals with Pressure Plates | ||||||||||||
| 2-45/64 (68.6) |
— — |
2-59/64 (74.2) |
3-15/16 (100) |
— — |
3-13/64 (81.4) |
||||||||
| Illuminated | Full Voltage | 3-11/64 (80.6) |
3-11/64 (80.6) |
3-23/64 (85.3) |
— — |
— — |
3-13/64 (81.4) |
||||||
| Transformer | 3-11/64 (80.6) |
3-11/64 (80.6) |
3-23/64 (85.3) |
— — |
— — |
3-35/64 (90.1) |
|||||||
Approximate Mounting Dimensions
Caution: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1‑1/2 in. (38.1 mm) minimum centers in one direction.
|
§ Large screw terminal contact blocks require a minimum vertical spacing of 1‑37/64 in. (40 mm); selector switches with wing lever knobs require 2‑1/4 in. (57.1 mm) vertical and horizontal minimum spacing and large round legend plates require 1‑1/2 in. (38.1 mm) minimum spacing.
| Shipping Weights in Ounces (kg) | |||||||
| Type of Unit | Weight | Type of Unit | Weight | ||||
| Push Buttons | Non-Illuminated | 3-1/4 (0.09) | Selector Switches |
Non-Illuminated | 4 (0.11) | ||
| Illuminated | Full Voltage | 3-1/2 (0.10) | Illuminated | Full Voltage | 4 (0.11) | ||
| Transformer | 5 (0.14) | Transformer | 5-1/2 (0.16) | ||||
| Pilot Lights | Pilot Light | 2-1/4 (0.06) | Push-Pull Units | Non-Illuminated | 4-1/2 (0.13) | ||
| Push-to-Test | 3 (0.09) | ||||||
| Pilot Light | 4-1/2 (0.13) | Illuminated | Full Voltage | 4-1/2 (0.13) | |||
| Push-to-Test | 5 (0.14) | Transformer | 5-1/2 (0.16) | ||||
| Cylinder Lock | 6 (0.17) | Potentiometer Units | 4 (0.11) | ||||
|
⋆ When using a padlocking cover and depending upon the types of adjacent units involved, the minimum vertical or horizontal spacing may have to be increased for operating clearance.
Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Legend Plates
|
|
|
|
|
||||
| Standard Half Round Legend Plate⋆ |
Standard Legend Plate§ | Large Size | Round | Small/Large Legend Plate |
⋆ The Bulletin 800MR large half round legend plates are not recommended for use with the twist-release units because of the operator knob size. The legend plate is virtually unreadable. Push-pull units can be mounted in a 1‑1/4 in. minimum horizontal spacing when no legend plate is used. Vertical spacing is 1‑1/2 in. when the Bulletin 800MR large half round legend plate is used.
These Bulletin 800MR legend plates consist of Bulletin 800T legend plates with Cat. No. 800MR-N50 adapter rings.