Bulletin 800MB Push Buttons
|
Bulletin 800MB
- 22.5 mm mounting hole
- Type 13 oiltight
- Square backlit operators
Standards Compliance and Certifications
UL Listed — File: E14840
Guide: NKCR
CSA Certified (File No. LR1234)
Product Selection
Momentary Contact Push Button Units, Non-Illuminated
Contact Terminations
Devices come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. For small screw terminations, add the letter S.
|
|
|
| Flush Head Unit Cat. No. 800MB-CA1B |
Extended Head Unit Cat. No. 800MB-CB1B |
Push Buttons, Illuminated
Momentary Contact Push Button Units, Illuminated
Contact Terminations
Devices come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. For small screw terminations, add the letter S.
|
|
|
| Flush Head Unit Cat. No. 800MB-CPA16GA |
Extended Head Unit Cat. No. 800MB-CQB24RA |
Momentary Contact Push Button Units, Non-Illuminated
| 800 | MB | | CA | 1 | A | ||||
| a | b | c | d | e |
| a | b | c | d | d (contd) | e | |||||||||||
| Bezel Color | Operator Type | Color Insert | Contact Block(s) | Contact Block(s) | Contact Block Termination Type |
|||||||||||
| Standard | Logic Reed with Stab Terminals | |||||||||||||||
| Code | Color | Code | Description | Code | Color | Code | Description | Code | Description | Code | Description | |||||
| MB | Black | CA | Flush head | X | No color insert | Blank | No contacts | D1R | 1 N.O. | Blank | Stab terminals | |||||
| MS | Gray | CB | Extended head | 1 | Green | D1 | 1 N.O. | D2R | 1 N.C. | K | Large screwT | |||||
| 3 | Orange | D2 | 1 N.C. | AR | 1 N.O. - 1 N.C. | S | Small screwT | |||||||||
| 4 | Gray | A | 1 N.O. - 1 N.C. | A2R | 2 N.O. | |||||||||||
| 5 | White | A2 | 2 N.O. | A4R | 2 N.C. | |||||||||||
| 6 | Red¬ | A4 | 2 N.C. | BR | 2 N.O. - 2 N.C. | |||||||||||
| 7 | Blue | A7 | 1 N.C.L.B. - 1 N.C. | |||||||||||||
| 9 | Yellow | B | 2 N.O. - 2 N.C. | |||||||||||||
|
Momentary Contact Push Button Units, Illuminated
| 800 | MB | | CQ | A | L | 06 | R | A | |||||||
| a | b | c | d | e | f | g | h |
| a | b | c | d | e | |||||||||
| Bezel Color | Power Module Type | Operator Type | Illumination Options | Voltage | |||||||||
| Full Voltage | |||||||||||||
| Code | Color | Code | Description | Code | Description | Code | Description | Code | Description | ||||
| MB | Black | CQ | Full Voltage | A | Flush | Blank | Incandescent | 06 | 6V AC/DC | ||||
| MS | Gray | CP | Transformer | B | Extended | L | LED § | 12 | 12V AC/DC | ||||
| 24 | 24V AC/DC | ||||||||||||
| 10 | 120V AC§ | ||||||||||||
| Transformer | |||||||||||||
| Code | Description | ||||||||||||
| 16 | 120V AC | ||||||||||||
| 26 | 240V AC | ||||||||||||
| f | g | g (contd) | h | |||||||
| Color Insert | Contact Block(s) | Contact Block(s) | Contact Block Termination Type |
|||||||
| Standard | Logic Reed with Stab Terminals | |||||||||
| Code | Color | Code | Description | Code | Description | Code | Description | |||
| Blank | No contacts | Blank | No contacts | D1R | 1 N.O. | Blank | Stab terminals | |||
| X | Packet of colored insertsØ | D1 | 1 N.O. | D2R | 1 N.C. | K | Large screwT | |||
| A | Amber | D2 | 1 N.C. | AR | 1 N.O. - 1 N.C. | S | Small screwT | |||
| B | Blue | A | 1 N.O. - 1 N.C. | A2R | 2 N.O. | |||||
| C | Clear | A2 | 2 N.O. | A4R | 2 N.C. | |||||
| G | Green | A4 | 2 N.C. | BR | 2 N.O. - 2 N.C.z | |||||
| R | Red¬ | A7 | 1 N.C.L.B. - 1 N.C. | |||||||
| B | 2 N.O. - 2 N.C.z | |||||||||
|
¬ Red flush head push buttons are not suitable for applications requiring extended head or other unguarded buttons capable of being operated quickly in emergencies, and they may not comply with applicable codes or standards.
T Not available with Logic Reed contact blocks.
LEDs are only available in red, green, amber, and white; lens color must match LED color.
§ White LED available in 24V AC/DC only.
§ LED only.
Ø Packet of colored inserts, one of each color. Not available with LED option for illuminated devices.
z Only available with full voltage illumination option and standard stab terminations.
Dual Lamp Momentary Contact Push Button Units, Illuminated
Contact Terminations
Devices come standard with stab terminations. Screw terminations are not available for these operators.
|
|
|
| Flush Head Unit Cat. No. 800MB-DA24GRBK |
Extended Head Unit Cat. No. 800MB-DG12RGA |
| 800 | MB | | DA | L | 24 | G | R | A | |||||
| a | b | c | d | e | f | g |
| a | b | c | d | |||||||
| Bezel Color | Operator Type | Illumination Options | Power Module Type and Voltage | |||||||
| Full Voltage | ||||||||||
| Code | Color | Code | Description | Code | Description | Code | Description | |||
| MB | Black | DA | Flush head | Blank | Incandescent | 06 | 6V AC/DC | |||
| MS | Gray | DG | Extended head | L | LED¬ T | 12 | 12V AC/DC | |||
| 24 | 24V AC/DC | |||||||||
| 10 | 120V AC§ | |||||||||
| e | f | g | |||||
| Lens Color | Lens Color | Contact Block(s) | |||||
| Top Position | Bottom Position | Standard | |||||
| Code | Color | Code | Color | Code | Description | ||
| X | Packet of colored inserts§ | X | Packet of colored inserts§ | Blank | No contacts | ||
| A | Amber | A | Amber | D1 | 1 N.O. | ||
| B | Blue | B | Blue | D2 | 1 N.C. | ||
| C | Clear/white | C | Clear/white | A | 1 N.O. - 1 N.C. | ||
| G | Green | G | Green | A2 | 2 N.O. | ||
| R | Red | R | Red | A4 | 2 N.C. | ||
| A7 | 1 N.C.L.B. - 1 N.C. | ||||||
| B | 2 N.O. - 2 N.C. | ||||||
| Logic Reed with Stab Terminals | |||||||
| D1R | 1 N.O. | ||||||
| D2R | 1 N.C. | ||||||
| AR | 1 N.O. - 1 N.C. | ||||||
| A2R | 2 N.O. | ||||||
| A4R | 2 N.C. | ||||||
| BR | 2 N.O. - 2 N.C. | ||||||
|
¬ LEDs are only available in red, green, amber, and white; lens color must match LED color.
T White LED available in 24V AC/DC only.
Both lamps must be the same voltage.
§ LED only.
§ Packet of colored inserts, one of each color. Not available with LED illumination option.
Pilot Light Units
Contact Terminations
Devices come standard with stab terminations. For large screw contact terminations, add letter S to the end of the cat. no. For push-to-test pilot lights, add the letter K.
|
|
|
| Pilot Light Cat. No. 800MB-CQ24RS |
Push-to-Test Pilot Light Cat. No. 800MB-CPT16G |
| Lamp | Type | Volts | Color | Pilot Light | Push-to-Test |
| Cat. No. | Cat. No. | ||||
| Incandescent | Full voltage | 24 AC/DC | Red | 800MB-CQ24R | 800MB-CQT24R |
| Green | 800MB-CQ24G | 800MB-CQT24G | |||
| Amber | 800MB-CQ24A | 800MB-CQT24A | |||
| Transformer | 120 AC 50/60 Hz |
Red | 800MB-CP16R | 800MB-CPT16R | |
| Green | 800MB-CP16G | 800MB-CPT16G | |||
| Amber | 800MB-CP16A | 800MB-CPT16A | |||
| LED | Full voltage | 12 AC/DC | Red | 800MB-CQL12R | 800MB-CQTL12R |
| Green | 800MB-CQL12G | 800MB-CQTL12G | |||
| Amber | 800MB-CQL12A | 800MB-CQTL12A | |||
| 24 AC/DC | Red | 800MB-CQL24R | 800MB-CQTL24R | ||
| Green | 800MB-CQL24G | 800MB-CQTL24G | |||
| Amber | 800MB-CQL24A | 800MB-CQTL24A | |||
| Transformer | 120 AC 50/60 Hz |
Red | 800MB-CPL16R | 800MB-CPTL16R | |
| Green | 800MB-CPL16G | 800MB-CPTL16G | |||
| Amber | 800MB-CPL16A | 800MB-CPTL16A | |||
Pilot Light Units, Dual Lamp
Contact Terminations
Devices come standard with stab terminations. Screw terminations are not available for these operators.
|
|
|
| Pilot Light Cat. No. 800MB-DL24GR |
Push-to-Test Pilot Light Cat. No. 800MB-DT24RG |
| Type | Lamp | Volts | Color | Pilot Light | Push-to-Test |
| Cat. No. | Cat. No. | ||||
| Full voltage | Incandescent | 12 AC/DC | Red (top) Green (bottom) |
800MB-DL12RG | 800MB-DT12RG |
| 24 AC/DC | 800MB-DL24RG | 800MB-DT24RG | |||
| 12 AC/DC | Blank with pack of color inserts |
800MB-DL12XX | 800MB-DT12XX | ||
| 24 AC/DC | 800MB-DL24XX | 800MB-DT24XX | |||
| LED | 12 AC/DC | Red (top) Green (bottom) |
800MB-DLL12RG | 800MB-DTL12RG | |
| 24 AC/DC | 800MB-DLL24RG | 800MB-DTL24RG | |||
Pilot Light Units
| 800 | MB | | CP | L | 24 | R | |||||
| a | b | c | d | e | f |
|
| a | b | c | |||||
| Bezel Color | Power Module Type | Illumination Options | |||||
| Code | Color | Code | Description | Code | Description | ||
| MB | Black | CP | Transformer | Blank | Incandescent | ||
| MS | Gray | CQ | Full voltage | L | LED¬ T | ||
| T | Push-to-test | ||||||
| TL | Push-to-test with LED¬ T | ||||||
| d | e | f | |||||
| Voltage | Lens Color | Termination Type | |||||
| Full Voltage | Pilot Lights | ||||||
| Code | Description | Code | Color | Code | Description | ||
| 06 | 6V AC/DC | X | Packet of colored inserts§ | Blank | Stab terminals | ||
| 12 | 12V AC/DC | A | Amber | S | Large screw | ||
| 24 | 24V AC/DC | B | Blue | Push-to-Test Pilot Lights | |||
| 10 | 120V AC | C | Clear/white | Code | Description | ||
| Transformer | G | Green | Blank | Stab terminals | |||
| Code | Description | R | Red | K | Large screw§ | ||
| 16 | 120V AC | S | Small screw§ | ||||
| 26 | 240V AC | ||||||
Pilot Light Units, Dual Lamp
| 800 | MB | | DL | L | 06 | G | R | ||||||
| a | b | c | d | e | f | g |
|
| a | b | c | d | |||||||
| Bezel Color | Operator Type | Illumination Options | Power Module Type and VoltageØ | |||||||
| Full Voltage | ||||||||||
| Code | Color | Code | Description | Code | Description | Code | Description | |||
| MB | Black | DL | Pilot light | Blank | Incandescent | 06 | 6V AC/DC | |||
| MS | Gray | DT | Push-to-test | L | LED ¬ T | 12 | 12V AC/DC | |||
| 24 | 24V AC/DC | |||||||||
| 10 | 120V AC | |||||||||
| e | f | g | |||||
| Lens Color | Lens Color | Termination Type | |||||
| Top Position | Bottom Position | ||||||
| Code | Color | Code | Color | Code | Description | ||
| X | Packet of colored inserts § | X | Packet of colored inserts § | Blank | Stab terminals | ||
| A | Amber | A | Amber | ||||
| B | Blue | B | Blue | ||||
| C | Clear/White | C | Clear/White | ||||
| G | Green | G | Green | ||||
| R | Red | R | Red | ||||
¬ LEDs are only available in red, green, amber, and white; lens color must match LED color.
T White LED available in 24V AC/DC only.
LED only.
§ Packet of colored inserts, one of each color. Not available with LED illumination option.
§ Only available with full voltage power module and standard stab terminations.
Ø Both lamps must be the same voltage.
Accessories
Modifications and Accessories
Boots
| Description | Cat. No. | |
|
Insulation Boot When properly combined with a Bulletin 800MR unit, this device meets CSA grounding requirements. |
800M-N18 |
| Cat. No. 800M-N18 | ||
Miscellaneous
Modifications and Accessories, Continued
Legend Plates
Special Legend Inserts
Special legend inserts are available. To order, specify Cat. No. 800MS-WC00E and marking required. A maximum of nine characters per line: one or two lines 0.140 in. high characters; three or four lines 0.110 in. high characters.
Split Face Legend Inserts
When ordering dual lamp legend inserts, specify Cat. No. 800MS-WC88E and marking required. A maximum of nine characters per line: one or two lines 0.140 in. characters; three or four lines 0.110 in. characters.
Bulletin 800M Backlit Legends
The table lists standard legend markings that are available. To order legend insert only, add the suffix of the legend to Cat. No. 800MS-WC. Example: Cat. No. 800MS-WC03 would be a FAST legend insert only. To order a standard legend insert with the backlit style device, add the suffix from the table to the end of the cat. no. Example: Cat. No. 800MS-CP16R09.
| Marking | Suffix | Marking | Suffix | Marking | Suffix | Marking | Suffix |
| CLOSE | 01 | LOW | 05 | RESET | 15 | UP | 22 |
| DOWN | 02 | LOWER | 11 | REV | 16 | 1ST SPEED | 25 |
| FAST | 03 | OFF | 09 | RUN | 17 | 2ND SPEED | 26 |
| FORWARD | 23 | ON | 10 | SLOW | 18 | 3RD SPEED | 27 |
| HIGH | 04 | OPEN | 13 | START | 19 | 4TH SPEED | 28 |
| IN | 06 | OUT | 12 | STOP | 20 | 0 | 40 |
| INCH | 07 | PUSH-TO-TEST | 29 | EMERG STOP | 24 | 1 | 41 |
| JOG | 08 | RAISE | 14 | TEST | 21 | — | — |
Replacement and Light Emitting Diode (LED) Lamps
All illuminated devices, except dual input diode and dual input transformer units, use T 1-3/4 wedge base units. Existing Bulletin 800M devices may have incandescent lamps replaced with shock and vibration resistant LEDs. Existing ANSI# 86, 73, or 85 lamps may be replaced by LEDs.
Specifications
Specifications¬
| Electrical Ratings | ||
| Contact Ratings | Refer to the Contact Ratings tables below. | |
| Dielectric Strength | 1600V for one minute | |
| 1300V for one minute (Logic Reed) | ||
| Electrical Design Life Cycles | 750 000 at maximum rated load | |
| 200 000 at maximum rated load (Logic Reed) | ||
| Mechanical Ratings | ||
| Vibration | 10…2000 Hz 1.52 mm displacement (peak-to-peak) max./10 G max. (except Logic Reed) | |
| Shock | 1/2 cycle sine wave for 11 ms ³ 25 G (contact fragility) and no damage at 100 G | |
| Degree of Protection | Type 13; IEC 144 IP65 Oiltight | |
| Contact Operation | Contact blocks with bifurcated spanner: Slow, make and break, simple break. | |
| Logic Reed contact blocks: Snap-action | ||
| Typical Operating Forces | 2.45 lb (10.8 N) | |
| Operators without Contact Blocks | ||
| Contact Blocks | Standard | 1.5 lb (6.7 N) 0.62 lb (2.6 N) |
| Logic Reed | ||
| Environment | ||
| Temperature Range | Operating | +32…+131 °F (0…+55 °C) |
| Storage | 40…+185 °F (40…+85 °C) | |
| Note:Operating temperatures at +32 °F (0 °C) are based on the absence of freezing moisture and liquids. | ||
| Humidity | 50% at +104 °F (+40 °C) | |
| Panel Thickness Requirements | 1/16…1/4 in. (1.6…6.4 mm) | |
| ¬ Performance Data — See Performance Data. | ||
Standard Contact Ratings
(IEC 337-1) (NEMA ICS 2-125) Maximum continuous current Ith 10 A. Bulletin 800MB units have control circuit ratings with 800M contact blocks as follows:
| Max. Oprtnl. Volts Ue |
Utilization Category | Rated Operational Currents | |||
| IEC | NEMA | Volts Ue | Make | Break | |
| AC 300 | AC-II | A300 | 120…300 72…120 24…72 T |
7200 VA 60 A 60 A |
720 VA 720 VA 10 A |
| T For applications below 24V and 24 mA, Logic Reed contacts are recommended. | |||||
Logic Reed Contact Ratings
Maximum: 150V AC, 0.15 A, 8VA, and 30V DC, 0.06 A, 1.8VA. Should only be used with resistive loads.
Wire Capacity
Small screw contact blocks —
Accept 1 (one) #14 or 2 (two) #16 AWG solid or stranded wires.
Large screw contact blocks —
Accept 2 (two) #12 AWG wires.
Push-on connectors —
Accept 2 (two) 0.110 in x 0.032 in connectors or 1 (one) 0.250 in x 0.032 in connector.
Approximate Dimensions
Approximate Dimensions and Shipping Weights
Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Extension Behind Panel for Square Units
CAUTION: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction.
|
|
|
||
| Units with Quick Connect Terminal Contact Blocks (Typical View) |
Units with PC Pin Connector Contact Blocks (Typical View) |
Mounting Configuration¬ |
¬ Large screw terminal contact blocks require a minimum vertical spacing of 1-37/64 in. (40 mm); selector switches with wing lever knobs require 2-1/4 in. (57.1 mm) vertical and horizontal minimum spacing and large round legend plates require 1-1/2 in. (38.1 mm) minimum spacing.
|
| Shipping Weights in Ounces (kg) | |||
| Type of Unit | Weight | ||
| Push buttons | Non-illuminated | 3-1/4 (0.09) | |
| Illuminated | Full voltage | 3-1/2 (0.10) | |
| Transformer | 5 (0.14) | ||
| Pilot lights |
Full voltage | 2-1/4 (0.06) | |
| Transformer | 4-1/2 (0.13) | ||
| Potentiometer units | 4 (0.11) | ||
| Dimension A | |||||
| Description | Quick Connect Terminal | PC Pin Connector Terminal | |||
| Push Button | Pilot Light | Push Button | Pilot Light | ||
| Illuminated | Full voltage | 2-23/32 (69.1) |
2-23/32 (69.1) |
— | — |
| Transformer | 2-1/4 (57.2) |
2-1/4 (57.2) |
2-5/8 (66.7) |
2-5/8 (66.7) |
|
| Non-illuminated | 2-1/4 (57.2) |
— | 2-5/8 (66.7) |
— | |
Approximate Dimensions and Shipping Weights, Continued
Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Extension Behind Panel for Square Units, Continued
CAUTION: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction.
|
|
|
| Units Having Small Screw Terminals with Pressure Plate Contact Blocks (Typical View) |
Units Having Large Screw Terminals with Pressure Plate Contact Blocks (Typical View) |
Front View of Square Units
CAUTION: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction.
|
|
|
||
| Unit without Insert and Backlit Unit |
Square Backlit with Guarded Bezel |
Square Backlit with Unguarded Bezel |
| Shipping Weights in Ounces (kg) | |||
| Type of Unit | Weight | ||
| Push buttons | Non-illuminated | 3-1/4 (0.09) | |
| Illuminated | Full voltage | 3-1/2 (0.10) | |
| Transformer | 5 (0.14) | ||
| Pilot lights | Full voltage | 2-1/4 (0.06) | |
| Transformer | 4-1/2 (0.13) | ||
| Potentiometer units | 4 (0.11) | ||
| Dimension A | |||||
| Description | Small Screw Terminal | Large Screw Terminal | |||
| Push Button | Pilot Light | Push Button | Pilot Light | ||
| Illuminated | Full voltage | 2-25/32 (70.6) |
2-25/32 (70.6) |
3-11/64 (80.6) |
3-11/64 (80.6) |
| Transformer | 2-25/32 (70.6) |
2-25/32 (70.6) |
3-11/64 (80.6) |
3-11/64 (80.6) |
|
| Non-illuminated | 2-5/16 (59) |
— | 2-45/64 (68.6) |
— | |