Bulletin 800MB Push Buttons

Click to enlarge - 800MB-2_25-1


Bulletin 800MB


Standards Compliance and Certifications

UL Listed — File: E14840
Guide: NKCR
CSA Certified (File No. LR1234)


Product Selection

Momentary Contact Push Button Units, Non-Illuminated

Contact Terminations

Devices come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. For small screw terminations, add the letter S.

Click to enlarge - 800MB-2_26-1    Click to enlarge - 800MB-2_26-2
Flush Head Unit
Cat. No. 800MB-CA1B
   Extended Head Unit
Cat. No. 800MB-CB1B

Contact Type Button Color Flush Head Extended Head
Cat. No. Cat. No.
Click to enlarge - 800T_800H-1_6-5 1 N.O. Green 800MB-CA1D1
Gray 800MB-CA4D1 800MB-CB4D1
Red 800MB-CB6D1
Yellow 800MB-CA9D1 800MB-CB9D1
Click to enlarge - 800T_800H-1_6-6 1 N.C. Green 800MB-CA1D2
Gray 800MB-CA4D2 800MB-CB4D2
Red 800MB-CB6D2
Yellow 800MB-CA9D2 800MB-CB9D2
Click to enlarge - 800T_800H-1_3-4 1 N.O. - 1 N.C. Green 800MB-CA1A
Gray 800MB-CA4A 800MB-CB4A
Red 800MB-CB6A
Yellow 800MB-CA9A 800MB-CB9A
Click to enlarge - 800T_800H-1_3-4 2 N.O. - 2 N.C. Green 800MB-CA1B
Gray 800MB-CA4B 800MB-CB4B
Click to enlarge - 800T_800H-1_3-4 Red 800MB-CB6B
Yellow 800MB-CA9B 800MB-CB9B
  

Push Buttons, Illuminated

Momentary Contact Push Button Units, Illuminated

Contact Terminations

Devices come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. For small screw terminations, add the letter S.

Click to enlarge - 800MB-2_26-6    Click to enlarge - 800MB-2_26-7
Flush Head Unit
Cat. No. 800MB-CPA16GA
   Extended Head Unit
Cat. No. 800MB-CQB24RA

Contact Type Type Volts/Lamp Color Flush Head Extended Head
Cat. No. Cat. No.
  Full voltage 24 AC/DC
Incandescent
50/60 Hz
Red 800MB-CQB24RA
Green 800MB-CQA24GA
Amber 800MB-CQA24AA 800MB-CQB24AA
Transformer 120 AC
Incandescent
Red 800MB-CPB16RA
Green 800MB-CPA16GA
Click to enlarge - 800T_800H-1_3-4 Amber 800MB-CPA16AA 800MB-CPB16AA
Full voltage 12 AC/DC
LED
Red 800MB-CQBL12RA
Green 800MB-CQAL12GA
1 N.O. -
1 N.C.
Amber 800MB-CQAL12AA 800MB-CQBL12AA
24 AC/DC
LED
Red 800MB-CQBL24RA
  Green 800MB-CQAL24GA
Amber 800MB-CQAL24AA 800MB-CQBL24AA
Transformer 120 AC
LED
50/60 Hz
Red 800MB-CPBL16RA
Green 800MB-CPAL16GA
Amber 800MB-CPAL16AA 800MB-CPBL16AA
  

Momentary Contact Push Button Units, Non-Illuminated

800 MB CA    1    A      
   a    b    c    d    e

a    b    c    d    d (cont’d)    e
Bezel Color Operator Type Color Insert Contact Block(s) Contact Block(s) Contact Block
Termination Type
Standard Logic Reed with Stab Terminals
Code Color Code Description Code Color Code Description Code Description Code Description
MB Black CA Flush head X No color insert Blank No contacts D1R 1 N.O. Blank Stab terminals
MS Gray CB Extended head 1 Green D1 1 N.O. D2R 1 N.C. K Large screwT 
    3 Orange D2 1 N.C. AR 1 N.O. - 1 N.C. S Small screwT 
4 Gray A 1 N.O. - 1 N.C. A2R 2 N.O.  
5 White A2 2 N.O. A4R 2 N.C.
6 Red¬  A4 2 N.C. BR 2 N.O. - 2 N.C.
7 Blue A7 1 N.C.L.B. - 1 N.C.  
9 Yellow B 2 N.O. - 2 N.C.

Click to enlarge - 800MB-2_27-1


Momentary Contact Push Button Units, Illuminated

800 MB CQ    A    L    06    R    A      
   a    b    c    d    e    f    g    h

a    b    c    d    e
Bezel Color Power Module Type Operator Type Illumination Options Voltage
Full Voltage
Code Color Code Description Code Description Code Description Code Description
MB Black CQ Full Voltage A Flush Blank Incandescent 06 6V AC/DC
MS Gray CP Transformer B Extended L LED‡ §  12 12V AC/DC
        24 24V AC/DC
10 120V AC§ 
Transformer
Code Description
16 120V AC
26 240V AC

f    g    g (cont’d)    h
Color Insert Contact Block(s) Contact Block(s) Contact Block
Termination Type
Standard Logic Reed with Stab Terminals
Code Color Code Description Code Description Code Description
Blank No contacts Blank No contacts D1R 1 N.O. Blank Stab terminals
X Packet of colored insertsØ  D1 1 N.O. D2R 1 N.C. K Large screwT 
A Amber D2 1 N.C. AR 1 N.O. - 1 N.C. S Small screwT 
B Blue A 1 N.O. - 1 N.C. A2R 2 N.O.  
C Clear A2 2 N.O. A4R 2 N.C.
G Green A4 2 N.C. BR 2 N.O. - 2 N.C.z 
R Red¬  A7 1 N.C.L.B. - 1 N.C.  
  B 2 N.O. - 2 N.C.z 

Click to enlarge - 800MB-2_27-1


¬ Red flush head push buttons are not suitable for applications requiring extended head or other unguarded buttons capable of being operated quickly in emergencies, and they may not comply with applicable codes or standards.
T Not available with Logic Reed contact blocks.
‡ LEDs are only available in red, green, amber, and white; lens color must match LED color.
§ White LED available in 24V AC/DC only.
§ LED only.
Ø Packet of colored inserts, one of each color. Not available with LED option for illuminated devices.
z Only available with full voltage illumination option and standard stab terminations.


Dual Lamp Momentary Contact Push Button Units, Illuminated

Contact Terminations

Devices come standard with stab terminations. Screw terminations are not available for these operators.

Click to enlarge - 800MB-2_28-1    Click to enlarge - 800MB-2_28-2
Flush Head Unit
Cat. No. 800MB-DA24GRBK
   Extended Head Unit
Cat. No. 800MB-DG12RGA

Type Contact Lamp Volts Color Flush Head Extended Head
Cat. No. Cat. No.
Full voltage Click to enlarge - 800T_800H-1_3-4 Incandescent 12 AC/DC Red (top)
Green (bottom)
800MB-DA12RGA 800MB-DG12RGA
24 AC/DC 800MB-DA24RGA 800MB-DG24RGA
12 AC/DC Blank with pack of color inserts 800MB-DA12XXA 800MB-DG12XXA
24 AC/DC 800MB-DA24XXA 800MB-DG24XXA
LED 12 AC/DC Red (top)
Green (bottom)
800MB-DAL12RGA 800MB-DGL12RGA
24 AC/DC 800MB-DAL24RGA 800MB-DGL24RGA
1 N.O. -
1 N.C.
Click to enlarge - 800T_800H-1_3-4 Incandescent 12 AC/DC Red (top)
Green (bottom)
800MB-DA12RGB 800MB-DG12RGB
24 AC/DC 800MB-DA24RGB 800MB-DG24RGB
12 AC/DC Blank with pack of color inserts 800MB-DA12XXB 800MB-DG12XXB
Click to enlarge - 800T_800H-1_3-4 24 AC/DC 800MB-DA24XXB 800MB-DG24XXB
LED 12 AC/DC Red (top)
Green (bottom)
800MB-DAL12RGB 800MB-DGL12RGB
24 AC/DC 800MB-DAL24RGB 800MB-DGL24RGB
2 N.O. -
2 N.C.
 

800 MB DA    L    24    G    R    A
   a    b    c    d    e    f    g

a    b    c    d
Bezel Color Operator Type Illumination Options Power Module Type and Voltage‡ 
Full Voltage
Code Color Code Description Code Description Code Description
MB Black DA Flush head Blank Incandescent 06 6V AC/DC
MS Gray DG Extended head L LED¬ T  12 12V AC/DC
      24 24V AC/DC
10 120V AC§ 

e    f    g
Lens Color Lens Color Contact Block(s)
Top Position Bottom Position Standard
Code Color Code Color Code Description
X Packet of colored inserts§  X Packet of colored inserts§  Blank No contacts
A Amber A Amber D1 1 N.O.
B Blue B Blue D2 1 N.C.
C Clear/white C Clear/white A 1 N.O. - 1 N.C.
G Green G Green A2 2 N.O.
R Red R Red A4 2 N.C.
    A7 1 N.C.L.B. - 1 N.C.
B 2 N.O. - 2 N.C.
Logic Reed with Stab Terminals
D1R 1 N.O.
D2R 1 N.C.
AR 1 N.O. - 1 N.C.
A2R 2 N.O.
A4R 2 N.C.
BR 2 N.O. - 2 N.C.

Click to enlarge - 800MB-2_28-4


¬ LEDs are only available in red, green, amber, and white; lens color must match LED color.
T White LED available in 24V AC/DC only.
‡ Both lamps must be the same voltage.
§ LED only.
§ Packet of colored inserts, one of each color. Not available with LED illumination option.


Pilot Light Units

Contact Terminations

Devices come standard with stab terminations. For large screw contact terminations, add letter S to the end of the cat. no. For push-to-test pilot lights, add the letter K.

Click to enlarge - 800MB-2_29-1    Click to enlarge - 800MB-2_29-2
Pilot Light
Cat. No. 800MB-CQ24RS
   Push-to-Test Pilot Light
Cat. No. 800MB-CPT16G

Lamp Type Volts Color Pilot Light Push-to-Test
Cat. No. Cat. No.
Incandescent Full voltage 24 AC/DC Red 800MB-CQ24R 800MB-CQT24R
Green 800MB-CQ24G 800MB-CQT24G
Amber 800MB-CQ24A 800MB-CQT24A
Transformer 120 AC
50/60 Hz
Red 800MB-CP16R 800MB-CPT16R
Green 800MB-CP16G 800MB-CPT16G
Amber 800MB-CP16A 800MB-CPT16A
LED Full voltage 12 AC/DC Red 800MB-CQL12R 800MB-CQTL12R
Green 800MB-CQL12G 800MB-CQTL12G
Amber 800MB-CQL12A 800MB-CQTL12A
24 AC/DC Red 800MB-CQL24R 800MB-CQTL24R
Green 800MB-CQL24G 800MB-CQTL24G
Amber 800MB-CQL24A 800MB-CQTL24A
Transformer 120 AC
50/60 Hz
Red 800MB-CPL16R 800MB-CPTL16R
Green 800MB-CPL16G 800MB-CPTL16G
Amber 800MB-CPL16A 800MB-CPTL16A
 

Pilot Light Units, Dual Lamp

Contact Terminations

Devices come standard with stab terminations. Screw terminations are not available for these operators.

Click to enlarge - 800MB-2_29-3    Click to enlarge - 800MB-2_29-4
Pilot Light
Cat. No. 800MB-DL24GR
   Push-to-Test Pilot Light
Cat. No. 800MB-DT24RG

Type Lamp Volts Color Pilot Light Push-to-Test
Cat. No. Cat. No.
Full voltage Incandescent 12 AC/DC Red (top)
Green (bottom)
800MB-DL12RG 800MB-DT12RG
24 AC/DC 800MB-DL24RG 800MB-DT24RG
12 AC/DC Blank with pack of
color inserts
800MB-DL12XX 800MB-DT12XX
24 AC/DC 800MB-DL24XX 800MB-DT24XX
LED 12 AC/DC Red (top)
Green (bottom)
800MB-DLL12RG 800MB-DTL12RG
24 AC/DC 800MB-DLL24RG 800MB-DTL24RG
 

Pilot Light Units

800 MB CP    L    24    R      
   a    b    c    d    e    f

Click to enlarge - 800MB-2_30-1


a    b    c
Bezel Color Power Module Type Illumination Options
Code Color Code Description Code Description
MB Black CP Transformer Blank Incandescent
MS Gray CQ Full voltage L LED¬ T 
    T Push-to-test
TL Push-to-test with LED¬ T 

d    e    f
Voltage Lens Color Termination Type
Full Voltage Pilot Lights
Code Description Code Color Code Description
06 6V AC/DC X Packet of colored inserts§  Blank Stab terminals
12 12V AC/DC A Amber S Large screw
24 24V AC/DC B Blue Push-to-Test Pilot Lights
10 120V AC‡  C Clear/white Code Description
Transformer G Green Blank Stab terminals
Code Description R Red K Large screw§ 
16 120V AC   S Small screw§ 
26 240V AC  

Pilot Light Units, Dual Lamp

800 MB DL    L    06    G    R      
   a    b    c    d    e    f    g

Click to enlarge - 800MB-2_30-2


a    b    c    d
Bezel Color Operator Type Illumination Options Power Module Type and VoltageØ 
Full Voltage
Code Color Code Description Code Description Code Description
MB Black DL Pilot light Blank Incandescent 06 6V AC/DC
MS Gray DT Push-to-test L LED ¬ T  12 12V AC/DC
      24 24V AC/DC
10 120V AC ‡ 

e    f    g
Lens Color Lens Color Termination Type
Top Position Bottom Position
Code Color Code Color Code Description
X Packet of colored inserts §  X Packet of colored inserts §  Blank Stab terminals
A Amber A Amber  
B Blue B Blue
C Clear/White C Clear/White
G Green G Green
R Red R Red

¬ LEDs are only available in red, green, amber, and white; lens color must match LED color.
T White LED available in 24V AC/DC only.
‡ LED only.
§ Packet of colored inserts, one of each color. Not available with LED illumination option.
§ Only available with full voltage power module and standard stab terminations.
Ø Both lamps must be the same voltage.


Accessories

Modifications and Accessories

Boots

  Description Cat. No.
Click to enlarge - 800MS-1_18-1 Insulation Boot
When properly combined with a Bulletin 800MR unit, this device meets CSA grounding requirements.
800M-N18
Cat. No. 800M-N18
  

Miscellaneous

  Description Cat. No.
Click to enlarge - 800MS-1_18-2 Lamp Remover
This tool can be used to remove and install wedge based lamps in Illuminated selector switches.
800M-N5
Cat. No. 800M‑N5
Click to enlarge - 800MB-2_31-3 Connectors
Used with wire sizes AWG 18…22. The connectors come in packages of 100 pieces.
¬  800M-NT2
Cat. No. 800M‑NT2
Click to enlarge - 800MS-1_18-4 Lens Remover
This device makes it easier to remove the lens.
800MS-N9
Cat. No. 800MS‑N9
  Description Style Color Cat. No.
Click to enlarge - 800MB-2_31-5 Additional Bezels
These bezels fit square traditional and backlit styles.
Flush button backlit Grey 800MS-N17
Black 800MB-N17
Extended button backlit Grey 800MS-N18
Black 800MB-N18
Cat. No. 800MS‑N17
  Description Type Cat. No.
Click to enlarge - 800MB-2_31-6 Legend Insert Do-It-Yourself Kits
These kits contain material necessary to create transparent backlit legend inserts
Legend marking start package 800MS-N13
Legend marking start package - French 800MS-N13F
Legend marking blank grid, bond paper 800MS-N14
Legend marking blank grid, vellum paper 800MS-N15
Cat. No. 800MS‑N13
  
¬ These must be ordered in multiples of 100.

Modifications and Accessories, Continued

  Description Type of Unit Color Cat. No.
Click to enlarge - 800MB-2_32-1 Color Chip Kits
These kits are available for replacement on backlit style devices. A packet of color chips containing one of each color is included in each kit.
Full-face illuminated Amber 800MS-N10A
Blue 800MS-N10B
Clear 800MS-N10C
Green 800MS-N10G
Red 800MS-N10R
Split-lens illuminated Amber 800MS-N11A
Blue 800MS-N11B
Clear 800MS-N11C
Green 800MS-N11G
Red 800MS-N11R
Non-illuminated Blue 800MS-N12B
Grey 800MS-N12GR
Green 800MS-N12G
Orange 800MS-N12O
Red 800MS-N12R
White 800MS-N12W
Yellow 800MS-N12Y
Cat. No. 800MS‑N10
  

Legend Plates

Special Legend Inserts

Special legend inserts are available. To order, specify Cat. No. 800MS-WC00E and marking required. A maximum of nine characters per line: one or two lines 0.140 in. high characters; three or four lines 0.110 in. high characters.

Split Face Legend Inserts

When ordering dual lamp legend inserts, specify Cat. No. 800MS-WC88E and marking required. A maximum of nine characters per line: one or two lines 0.140 in. characters; three or four lines 0.110 in. characters.

Bulletin 800M Backlit Legends

The table lists standard legend markings that are available. To order legend insert only, add the suffix of the legend to Cat. No. 800MS-WC. Example: Cat. No. 800MS-WC03 would be a FAST legend insert only. To order a standard legend insert with the backlit style device, add the suffix from the table to the end of the cat. no. Example: Cat. No. 800MS-CP16R09.

Marking Suffix Marking Suffix Marking Suffix Marking Suffix
CLOSE 01 LOW 05 RESET 15 UP 22
DOWN 02 LOWER 11 REV 16 1ST SPEED 25
FAST 03 OFF 09 RUN 17 2ND SPEED 26
FORWARD 23 ON 10 SLOW 18 3RD SPEED 27
HIGH 04 OPEN 13 START 19 4TH SPEED 28
IN 06 OUT 12 STOP 20 0 40
INCH 07 PUSH-TO-TEST 29 EMERG STOP 24 1 41
JOG 08 RAISE 14 TEST 21
  

Replacement and Light Emitting Diode (LED) Lamps

Lamp Type Lamp Voltage ANSI Number Cat. No.
Click to enlarge - 800MB-2_32-2 Full Voltage and Transformer 6.3V AC 86 800M-N15
Full Voltage 12V AC/DC 73 800M-N16
Incandescent 24V AC/DC 85 800M-N17
Click to enlarge - 800MB-2_32-3 Full Voltage 6.3V AC/DC ¬  800T-N60x
14V AC/DC ¬  800T-N61x
28V AC/DC T  800T-N62x
120V AC ¬  800T-N64x
Standard LED Transformer 6.3 AC ¬  800T-N60x
  
¬ To complete the cat. no. replace the x with the first letter of the desired color: Amber, Green, or Red.
T To complete the cat. no. replace the x with the first letter of the desired color: Amber, Green, Red, or White.

All illuminated devices, except dual input diode and dual input transformer units, use T 1-3/4 wedge base units. Existing Bulletin 800M devices may have incandescent lamps replaced with shock and vibration resistant LEDs. Existing ANSI# 86, 73, or 85 lamps may be replaced by LEDs.

Specifications

Specifications¬ 

Electrical Ratings
Contact Ratings Refer to the Contact Ratings tables below.
Dielectric Strength 1600V for one minute
1300V for one minute (Logic Reed)
Electrical Design Life Cycles 750 000 at maximum rated load
200 000 at maximum rated load (Logic Reed)
Mechanical Ratings
Vibration 10…2000 Hz 1.52 mm displacement (peak-to-peak) max./10 G max. (except Logic Reed)
Shock 1/2 cycle sine wave for 11 ms ³ 25 G (contact fragility) and no damage at 100 G
Degree of Protection Type 13; IEC 144 IP65 Oiltight
Contact Operation Contact blocks with bifurcated spanner: Slow, make and break, simple break.
Logic Reed contact blocks: Snap-action
Typical Operating Forces 2.45 lb (10.8 N)
Operators without Contact Blocks
Contact Blocks Standard 1.5 lb (6.7 N)
0.62 lb (2.6 N)
Logic Reed
Environment
Temperature Range Operating +32…+131 °F (0…+55 °C)
Storage –40…+185 °F (–40…+85 °C)
Note:Operating temperatures at +32 °F (0 °C) are based on the absence of freezing moisture and liquids.  
Humidity 50% at +104 °F (+40 °C)
Panel Thickness Requirements 1/16…1/4 in. (1.6…6.4 mm)
  
¬ Performance Data — See Performance Data.

Standard Contact Ratings

(IEC 337-1) (NEMA ICS 2-125) Maximum continuous current Ith 10 A. Bulletin 800MB units have control circuit ratings with 800M contact blocks as follows:

Max. Oprtnl.
Volts Ue
Utilization Category Rated Operational Currents
IEC NEMA Volts Ue Make Break
AC 300 AC-II A300 120…300
72…120
24…72 T 
7200 VA
60 A
60 A
720 VA
720 VA
10 A
  
T For applications below 24V and 24 mA, Logic Reed contacts are recommended.

Logic Reed Contact Ratings

Maximum: 150V AC, 0.15 A, 8VA, and 30V DC, 0.06 A, 1.8VA. Should only be used with resistive loads.

Wire Capacity

Small screw contact blocks —
Accept 1 (one) #14 or 2 (two) #16 AWG solid or stranded wires.
Large screw contact blocks —
Accept 2 (two) #12 AWG wires.
Push-on connectors —
Accept 2 (two) 0.110 in x 0.032 in connectors or 1 (one) 0.250 in x 0.032 in connector.


Approximate Dimensions

Approximate Dimensions and Shipping Weights

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Extension Behind Panel for Square Units

CAUTION: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction.

Click to enlarge - 800MB-2_33-1    Click to enlarge - 800MB-2_33-2    Click to enlarge - 800MB-2_33-3
Units with Quick Connect
Terminal Contact Blocks
(Typical View)
   Units with PC Pin
Connector Contact
Blocks (Typical View)
   Mounting Configuration¬ 

¬ Large screw terminal contact blocks require a minimum vertical spacing of 1-37/64 in. (40 mm); selector switches with wing lever knobs require 2-1/4 in. (57.1 mm) vertical and horizontal minimum spacing and large round legend plates require 1-1/2 in. (38.1 mm) minimum spacing.


Click to enlarge - 800MB-2_33-4


Shipping Weights in Ounces (kg)
Type of Unit Weight
Push buttons Non-illuminated 3-1/4 (0.09)
Illuminated Full voltage 3-1/2 (0.10)
Transformer 5 (0.14)
Pilot
lights
Full voltage 2-1/4 (0.06)
Transformer 4-1/2 (0.13)
Potentiometer units 4 (0.11)
  

Dimension A
Description Quick Connect Terminal PC Pin Connector Terminal
Push Button Pilot Light Push Button Pilot Light
Illuminated Full voltage 2-23/32
(69.1)
2-23/32
(69.1)
Transformer 2-1/4
(57.2)
2-1/4
(57.2)
2-5/8
(66.7)
2-5/8
(66.7)
Non-illuminated 2-1/4
(57.2)
2-5/8
(66.7)
  

Approximate Dimensions and Shipping Weights, Continued

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Extension Behind Panel for Square Units, Continued

CAUTION: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction.

Click to enlarge - 800MB-2_34-1    Click to enlarge - 800MB-2_34-2
Units Having Small Screw Terminals
with Pressure Plate Contact Blocks
(Typical View)
   Units Having Large Screw Terminals
with Pressure Plate Contact Blocks
(Typical View)

Front View of Square Units

CAUTION: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction.

Click to enlarge - 800MB-2_34-3    Click to enlarge - 800MB-2_34-4    Click to enlarge - 800MB-2_34-5
Unit without Insert
and Backlit Unit
   Square Backlit
with Guarded Bezel
   Square Backlit
with Unguarded Bezel

Shipping Weights in Ounces (kg)
Type of Unit Weight
Push buttons Non-illuminated 3-1/4 (0.09)
Illuminated Full voltage 3-1/2 (0.10)
Transformer 5 (0.14)
Pilot lights Full voltage 2-1/4 (0.06)
Transformer 4-1/2 (0.13)
Potentiometer units 4 (0.11)
  

Dimension A
Description Small Screw Terminal Large Screw Terminal
Push Button Pilot Light Push Button Pilot Light
Illuminated Full voltage 2-25/32
(70.6)
2-25/32
(70.6)
3-11/64
(80.6)
3-11/64
(80.6)
Transformer 2-25/32
(70.6)
2-25/32
(70.6)
3-11/64
(80.6)
3-11/64
(80.6)
Non-illuminated 2-5/16
(59)
2-45/64
(68.6)