Catalogs > Industrial Controls Catalog > Push Buttons > Hazardous Location > Bulletin 800R Hazardous Location Push Buttons
Bulletin 800R Hazardous Location Push Buttons
Specifications⋆ | Electrical Ratings | ||
| Contact Ratings | Refer to the contact ratings (Sealed Switch Contact Ratings). | |
| Dielectric Strength | 2200V for one minute, 1300V for one minute (Logic Reed) | |
| Electrical Design Life Cycles | 1 000 000 at maximum rated load, 200 000 at maximum rated load (Logic Reed) | |
| Mechanical Ratings | ||
| Vibration | 10…2000 Hz 1.52 mm displacement (peak-to-peak) Max./10 G Max. (except Logic Reed) | |
| Shock | 1/2 cycle sine wave for 11 ms ³25 G (contact fragility) and no damage at 100 G | |
| Degree of Protection | Type 4/4X/13, 4/13; Watertight/Corrosion-Resistant IEC 529 IP66/65 | |
| Mechanical Design Life Cycles | ||
| Push Buttons | (Momentary, Non-Illuminated) (Momentary, Illuminated) (Push-Pull/Twist-to-Release) |
1 000 0000 min. 250 000 min. 250 000 min. |
| Selector Switches | (Non-Illuminated) (Illuminated) |
1 000 000 min. 200 000 min. |
| All other devices | 200 000 min. | |
| Contact Operation | Logic Reed and sealed switch contact blocks: single break magnetic | |
| Typical Operating Forces | ||
| Operators without contact blocks | Flush, extended, standard mushroom, jumbo plastic mushroom: 2 lb max. Maintained selector switch: 3.6 inlb maximum |
|
| Spring Return Selector Switches | 3.6 inlb to stop | |
| 0.2 inlb to return | ||
| Illuminated Push Buttons and Push-to-Test Pilot Lights | 5 lb maximum | |
| 3-Position Push-Pull | 8 lb maximum push to in position or pull to center position (15 lb maximum pull to out position) |
|
| Push-Pull and Push-Pull/Twist | 9 lb maximum push or pull | |
| 30 inoz maximum twist, 6 inoz minimum return | ||
| Contact Blocks | Logic Reed Sealed Switch Stackable Sealed Switch |
1 lb maximum 3 lb maximum at 0.205 in. plunger travel 1 lb maximum |
| Environment | ||
| Temperature Range | Operating Storage |
-40...+131 °F (-40...+55 °C) -40...+185 °F (-40...+85 °C) |
| Note:Operating temperatures below freezing are based on the absence of moisture and liquids. Consult your local Rockwell Automation sales office or Allen‑Bradley distributor for use in lower temperature applications. | ||
| Humidity | 50% at 104 °F (40 °C) | |
| ⋆ Performance Data — See Performance Data. | ||