Hazardous Location

Catalogs > Industrial Controls Catalog > Push Buttons > Hazardous Location > Bulletin 800H Type 7&9 Hazardous Location Push Buttons

Bulletin 800H Type 7&9 Hazardous Location Push Buttons

Introduction Standards Compliance and Certifications Product Selection Product Selection for Stations
Modifications and Accessories Pilot Light Wiring Diagrams Specifications Approximate Dimensions
Product Selection for Stations

Ordering Information for Stations

Stations

Bulletin 800H Type 7 & 9 stations are available as factory assembled or as components for field assembly.

Factory-Assembled Stations

Bulletin 800H Type 7 & 9 control stations are designed to meet the requirements of the National Electrical Code. These stations are listed by Underwriters Laboratories, Inc. for Class I, Divisions 1 & 2, Groups C & D Hazardous Gases or Vapors, Class II, Divisions 1 & 2, Groups E, F & G Hazardous Dust and Class III Hazardous Fiber Locations. In addition the single gang shallow base, Cat. No. 800H‑IHZX7, meets Class I, Group B requirements as defined in the National Electrical Code.

Factory-assembled stations may be ordered in three ways:



Components for Field Assembled Stations

Eight-gang maximum⋆ . These 2- and 3-gang modules may be assembled into the multi-gang stations by installing a coupler kit between the enclosures. These separate bases, covers, or bases with covers are Underwriters Laboratories, Inc. listed when properly assembled. These enclosures meet the requirements of Class I, Division 1 & 2, Groups C & D, Class II, Divisions 1 & 2, Groups E, F & G, and Class III hazardous locations as defined in the National Electrical Code. Bulletin 800H Type 7 & 9 components are designed for these modular enclosures and are UL Listed for this purpose.

Note: Components may be assembled as multi-gang units up to an eight-gang maximum⋆ .

To select components for field assembly, follow the instructions for ordering a custom-built station.


Instructions for Ordering Custom-Built Stations

1.  Select operators required from Complete Assembled Stations (Supplied with 3/4 in. Dead End Conduit Entry — Cat. No. 800H‑1HZX7). (If lever type, select covers from Covers, Lever Type Actuator and go to Step 3).

2.  Select covers based on mounting requirements on Covers, Lever Type Actuator.

3.  Select an assembled base from Assembled Bases (for Field Assembly and Custom Stations) in accordance with the number of covers selected in Step 2.

4.  Select legend plates from Legend PlatesLegend Plates, Continued (and accessories, if required, from pages Modifications and AccessoriesLocking Attachments).

5.  If a particular sequence of operators or mounting orientation (vertical versus horizontal) is required, include a rough sketch.


Station Design Guidelines

(Also see Applicable Codes and Standards)

1.  Push-to-test pilot lights, illuminated push buttons, push-to-pull units, 4-position selector switches, and all operators with two contact blocks fastened along side one another or with a power module and contact block along side one another must be installed in a single hole cover.

2.  Dual push button units may only be installed in a single-hole cover or the specially designed two-hole cover (Cat. No. 800H-NP33), which can accommodate the dual push button and the special pigtail pilot light (Cat. No. 800H-LPK10R).


3.  When two components are installed in one cover, contact blocks are restricted to one side of the operator. Contact blocks of each operator must face each other.

4.  One level of contact blocks is maximum in a shallow base or deep base when used with a sealing well. Contact blocks, except sealed switch type, may be mounted two deep in other bases.

5.  If sealed switch contact blocks or a sealing well are used, a deep enclosure is required.


6.  a. START push buttons should be green or black flush, installed to the left or above STOP push buttons.
b. EMERGENCY STOP push buttons should be a red mushroom.
c. STOP push buttons should be red extended, installed to the right or below START push button.
d. STOP push buttons should be installed in the last position (bottom or right) of each unit when required.
e. Pilot lights should be installed in the first position (top or left side) of each unit when required.


Click to enlarge - 800H-2_23a-7


Design Guideline #1

Push-to-test pilot lights, illuminated push buttons, push-pull units, 4-position selector switches, all operators with two contact blocks fastened along side one another or with a power module and contact block along side one another must be installed in a single hole cover.

Click to enlarge - 800H-2_23a-9


Design Guideline #2

Dual push button units may only be installed in a single hole cover or the specially designed two hole cover (Cat. No. 800H‑NP33), which can accommodate the dual push button and the special pigtail pilot light (Cat. No. 800H‑LPK10R).

Click to enlarge - 800H-2_23a-8


Design Guideline #3

When two components are installed in one cover, contact blocks are restricted to one side of the operator. Contact blocks of each operator must face each other.

Design Guideline #4

One level of contact blocks is maximum in a shallow base or deep base when used with a sealing well. Contact blocks, except sealed switch type, may be mounted two deep in other bases.

⋆ Flange width is designed to comply with Underwriters Laboratories standards to enclosures with an internal free volume of up to 300 cubic inches (a maximum 8-gang assembly).


Product Selection

Covers, Lever Type Actuator

Note:Lever type covers are furnished without contact blocks. Legend plate for half lever is STOP; full lever momentary and maintained is a START-STOP. To order without legend plate, add suffix X to the cat. no.

Click to enlarge - 800H-2_23a-1    Click to enlarge - 800H-2_23a-2
Half Lever    Double Lever Momentary

Half Lever Double Lever Momentary Double Lever Maintained Double Lever Momentary/Maintained⋆ 
Cat. No. Cat. No. Cat. No. Cat. No.
800H-NP14 800H-NP15 800H-NP16 800H-NP34
 
⋆ A normally open circuit configuration is recommended for use behind this momentary lever and a late break normally closed circuit configuration is required for use behind the maintained lever to achieve proper functioning of the device.

Covers, Component Type Button

Click to enlarge - 800H-2_23a-3    Click to enlarge - 800H-2_23a-4    Click to enlarge - 800H-2_23a-5    Click to enlarge - 800H-2_23a-6

Blank One Hole‡  Two Hole§  Two Hole Special♣ 
Cat. No. Cat. No. Cat. No. Cat. No.
800H-NP32 800H-NP30 800H-NP31 800H-NP33
 

‡ One-hole covers use a jumbo legend plate only.
§ Two-hole covers use a standard legend plate only.
♣ This special two-hole cover can accommodate the pigtail pilot light (Bulletin 800H-LPK10 series), the dual push button or any non-illuminated unit. Legend plates (Cat. No. 800H-Y140J green and red split-field) and (Cat. No. 800H-Y141J grey full field), are the only legend plates suitable for use with this cover.


Assembled Bases (for Field Assembly and Custom Stations)

Enclosure Covers See enclosure cover tables for a complete listing of covers for these bases.
Special Conduit Entries For conduit entries not listed, consult your local Rockwell Automation sales office or Allen-Bradley distributor.


Click to enlarge - 800H-2_24a-1    Click to enlarge - 800H-2_24a-2    Click to enlarge - 800H-2_24a-3
1-Gang Shallow⋆     1-Gang Deep‡     2-Gang Horizontal‡ 

Conduit Entry Cat. No. Cat. No. Cat. No.
3/4 in. Dead End 800H-1HZX7 800H-1HVX7
3/4 in. Feed Through 800H-1HVX7M1
1 in. Dead End 800H-1HVX7M2 800H-2HHX7
1 in. Feed Through 800H-1HVX7M3
 
⋆ Shallow base cannot accommodate sealing well, sealed switched contact blocks, or stacked contact blocks. Shallow base rated for Group B.
‡ Deep base can accommodate sealing well, sealed switch contact blocks, or up to 2 deep standard contact blocks.

Click to enlarge - 800H-2_24a-4    Click to enlarge - 800H-2_24a-5    Click to enlarge - 800H-2_24a-6
2-Gang Vertical‡     3-Gang Vertical‡     4-Gang‡ 

Conduit Entry Cat. No. Cat. No. Cat. No.
1 in. Feed Through 800H-2HYX7 800H-3HYX7 800H-4HVX7
 
‡ Deep base can accommodate sealing well, sealed switch contact blocks, or up to 2 deep standard contact blocks.

Click to enlarge - 800H-2_24a-7    Click to enlarge - 800H-2_24a-8
6-Gang‡     8-Gang‡ 

Conduit Entry Cat. No. Cat. No.
1 in. Feed Through 800H-6HVX7 800H-8HVX7
 
‡ Deep base can accommodate sealing well, sealed switch contact blocks, or up to 2 deep standard contact blocks.

Bases for Multi-Gang Stations

Click to enlarge - 800H-2_25a-1    Click to enlarge - 800H-2_25a-2    Click to enlarge - 800H-2_25a-3

Conduit Sizes Cat. No. Cat. No. Cat. No.
3/4 in. Feed Through 800H-NP40C 800H-NP41C
1 in. Feed Through 800H-NP40D 800H-NP41D
3/4 in. Dead End 800H-NP42A
1 in. Dead End 800H-NP42B
  

Click to enlarge - 800H-2_25a-4    Click to enlarge - 800H-2_25a-5    Click to enlarge - 800H-2_25a-6    Click to enlarge - 800H-2_25a-7

Conduit Sizes Cat. No. Cat. No. Cat. No. Cat. No.
3/4 in. Dead End 800H-NP43A 800H-NP44A 800H-NP46A
1 in. Dead End 800H-NP43B 800H-NP44B 800H-NP46B
None 800H-NP45
  

Example:
7-gang base with 1 in. through-feed conduit consists of:
3-Cat. No. 800H-NP42B
1-Cat. No. 800H-NP43B
1-Cat. No. 800H-NP44B
1-Cat. No. 800H-NP45
1-Cat. No. 800H-NP46B
6-Cat. No. 800H-NP7
Plus up to four 1 in. plugs (Cat. No. 800H-NP11) to close unused conduit openings.
Caution:
Do not assemble more than eight enclosure gangs together, to avoid exceeding the internal volume for which the flame path of these enclosures is designed.


Click to enlarge - 800H-2_25a-8


⋆ When coupling modular enclosures together, a coupler kit (Cat. No. 800H-NP7) is required between enclosures.
§ 1 in. conduit through-feed (all gangs).