Hazardous Location

Catalogs > Industrial Controls Catalog > Push Buttons > Hazardous Location > Bulletin 800H Type 7&9 Hazardous Location Push Buttons

Bulletin 800H Type 7&9 Hazardous Location Push Buttons

Introduction Standards Compliance and Certifications Product Selection Product Selection for Stations
Modifications and Accessories Pilot Light Wiring Diagrams Specifications Approximate Dimensions
Approximate Dimensions

Approximate Dimensions and Shipping Weights

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Standard Legend Plate
(used with two-hole cover)
  Jumbo Legend Plate
(used with one-hole cover)
Click to enlarge - 800H-2_33a-1   Click to enlarge - 800H-2_33a-2

Note: Mounting hole requirements for components — 3/4 in. - 14 NPSM.⋆ 
⋆ External thread major diameter: 1.034 in. max., 1.024 in. min.
Internal thread minor diameter: 0.958 in. min., 0.970 in. max.
‡ Sketch illustrates the minimum distance between center lines when mounting Bulletin 800H units with legend plates either side by side or one above the other in non Allen‑Bradley enclosures. Minimum spacing without legend plate: When units are mounted so that the contact block terminals face each other, the 2‑1/4 in. (57.2 mm) dimension must be used in order to get proper electrical clearance. When control units are mounted so that the contact block terminals do not face each other, the 1‑27/32 in. (46.8 mm) dimension can be used.


Panel Thickness Requirements

Standard Barrel
[devices will fit panels up to 1 in. (25.4 mm)]
  Long Barrel
[devices will fit panels up to 2-1/2 in. (63.5 mm)]
Click to enlarge - 800H-2_33a-3   Click to enlarge - 800H-2_33a-4

‡ When mounting in a panel thicker than 2-1/8 in. (54 mm) locking bracket not required.
§ This dimension for push buttons only.


Push Buttons

Dual Head

Click to enlarge - 800H-2_33a-5


Dim. A B C Ship. Wt.
[oz (kg)]
Standard Barrel 3-5/16
(84.1)
4-3/16
(106.4)
4-7/16
(112.7)
10-3/8
(0.30)
Long Barrel 4-19/32
(116.7)
5-15/32
(138.9)
5-23/32
(145.2)
13
(0.37)
  

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Push Buttons

Mushroom Head   Push Button with Extra Long Guard
Click to enlarge - 800H-2_34a-1   Click to enlarge - 800H-2_34a-3
 
Flush Head   Extended Head
Click to enlarge - 800H-2_34a-2   Click to enlarge - 800H-2_34a-4

Type Standard Barrel Long Barrel
A ⋆  B C Ship. Wt.
[oz (kg)]
A ‡  B C Ship. Wt.
[oz (kg)]
Mushroom, Flush and Extended Head 3-3/16 (81) 4-1/8 (105) 4-3/8 (111) 9-7/8 (0.28) 5 (127) 5-7/8 (149.2) 6-1/8 (155.6) 13-5/16 (0.38)
Extra Long Guard 3-3/16 (81) 4-1/8 (105) 4-3/8 (111) 10-7/8 (0.31) 5 (127) 5-7/8 (149.2) 6-1/8 (155.6) 14-5/16 (0.40)
  
⋆ When using sealed switch contact block, this dimension is 4-1/16 in. (103 mm).
‡ When using sealed switch contact block, this dimension is 5-7/8 in. (149.2 mm).

Selector Switches

Standard Operator   Knob Lever Operator
Click to enlarge - 800H-2_34a-5   Click to enlarge - 800H-2_34a-7
 
Wing Lever Operator   Cylinder Lock Operator
Click to enlarge - 800H-2_34a-6   Click to enlarge - 800H-2_34a-8

Type Standard Barrel Long Barrel
A ⋆  B C Ship. Wt.
[oz (kg)]
A ‡  B C Ship. Wt.
[oz (kg)]
Standard and Knob Lever 3-3/16 (81) 4-1/8 (105) 4-3/8 (111) 9-1/2 (0.27) 5 (127) 5-7/8 (149.2) 6-1/8 (155.6) 14-3/8 (0.41)
Wing Lever 3-3/16 (81) 4-1/8 (105) 4-3/8 (111) 10-1/2 (0.30) 5 (127) 5-7/8 (149.2) 6-1/8 (155.6) 15 (0.42)
Cylinder Lock 3-3/16 (81) 4-1/8 (105) 4-3/8 (111) 11-1/4 (0.32) 5 (127) 5-7/8 (149.2) 6-1/8 (155.6) 16 (0.45)
  
⋆ When using sealed switch contact block, this dimension is 4-1/16 in. (103 mm).
‡ When using sealed switch contact block, this dimension is 5-7/8 in. (149.2 mm).

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Illuminated Push Buttons or Push-to-Test Pilot Lights

Transformer Type   Full Voltage, Dual Input or Neon Type
Click to enlarge - 800H-2_35a-1 Click to enlarge - 800H-2_35a-2

Illuminated Push Buttons, Push-to-Test Pilot Lights
Description Style A ⋆  B C Ship. Wt.
[oz (kg)]
Transformer Type Standard Barrel 3-5/32 (80.2) 3-29/32 (99) 4-1/8 (105) 14 (0.40)
Long Barrel 5-1/16 (128.6) 5-13/16 (147.6) 6-1/16 (154) 16-3/16 (0.45)
Full Voltage Dual Input or Neon Type Standard Barrel 3-1/32 (77) 3-29/32 (99) 4-1/8 (105) 11-5/8 (0.33)
Long Barrel 4-15/16 (125.4) 5-13/16 (147.6) 6-1/16 (154) 13-7/16 (0.38)
  

Push-Pull Units

Non-Illuminated   Illuminated
Click to enlarge - 800H-2_35a-3 Click to enlarge - 800H-2_35a-4

Push-Pull Units
Description Style A ⋆  B C D Ship. Wt.
[oz (kg)]
Illuminated Transformer Type Standard Barrel 3-9/16 (90.5) 4-9/16 (115.9) 4-5/8 (117.5) 2-1/8 (54) 15-1/2 (0.44)
Long Barrel 4-21/32 (118.3) 5-13/32 (137) 5-21/32 (143.7) 2-1/8 (54) 17-7/16 (0.49)
Illuminated Full Voltage Type Standard Barrel 3-7/16 (87.3) 4-9/16 (115.9) 4-5/8 (117.5) 1-31/32 (50) 12-13/16 (0.33)
Long Barrel 4-17/32 (115.1) 5-13/32 (137) 5-21/32 (143.7) 1-31/32 (50) 14-3/4 (0.41)
Non-Illuminated Push-Pull Units Standard Barrel 3-1/2 (88.9) 4-3/8 (111.1) 4-5/8 (117.5) 11-1/8 (0.32)
Long Barrel 4-17/32 (115.1) 5-13/32 (137) 5-21/32 (143.7) 12-5/16 (0.34)
  
⋆ When using sealed switch contact block add 7/8 in. (22.2 mm) to the listed dimension.

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Pilot Lights   Transformer Type
Click to enlarge - 800H-2_36a-1   Click to enlarge - 800H-2_36a-2
     
Full Voltage, Pigtail Type
Click to enlarge - 800H-2_36a-3

Description Style A Ship. Wt. [oz (kg)]
Transformer type and dual input transformer type pilot lights Standard Barrel 3-5/32 (80) 8-9/16 (0.24)
Long Barrel 4-9/16 (115.9) 30-1/4 (0.85)
Full voltage, neon or dual input diode and resistor type pilot lights Standard Barrel 3-1/32 (77) 5-13/16 (0.17)
Long Barrel 4-7/16 (112.7) 27-1/2 (0.77)
Full voltage pigtail type pilot lights Standard Barrel 2-3/16 (55.5) 5-5/8 (0.16)
Long Barrel 3-43/64 (94) 8-5/16 (0.24)
  

Potentiometer Units

Click to enlarge - 800H-2_36a-4


Style A Ship. Wt. [oz (kg)]
Standard barrel 3-1/8 (79.5) 5-3/8 (0.16)
Long barrel 4-1/2 (114.3) 8 (0.23)
  

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Shallow Base Stations

Figure 1
Shallow Base Station Lever Type
  Figure 2
Shallow Base Station Component Type
1-Gang (1 or 2 devices)
Click to enlarge - 10_165_800H7-9_dim1   Click to enlarge - 10_165_800H7-9_dim2
Shipping Wt. 3 lbs (1.36 kg)   Shipping Wt. 3-1/2 lbs (1.58 kg)

Deep Base Stations

Figure 3
Deep Base Station Lever Type
1-Gang
  Figure 4
Deep Base Component Lever Type
1-Gang (1 or 2 devices)
Click to enlarge - 800H-2_37a-3   Click to enlarge - 800H-2_37a-4
Shipping Wt. 4 lbs (1.81 kg)   Shipping Wt. 4-1/2 lbs (2.04 kg)

⋆ When using a flange seal, an approved drain fitting must be provided (refer to National Electrical Code).
‡ When used add the following to the max. depth: Flange seal add 3/16 in. (4.8 mm). Sealing well with or without integral flange seal add 1/2 in. (12.7 mm).


Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Factory-Assembled Stations

For depth dimension refer to Figure 3 or 4 on Shallow Base Stations.

Figure 3
Control Station, 2-Gang (up to 4 devices)
  Figure 4
Control Station, 3-Gang (up to 6 devices)
Click to enlarge - 800H-2_38a-1   Click to enlarge - 800H-2_38a-2
Shipping Wt. 10 lbs (4.54 kg) Shipping Wt. 16 lbs (7.26 kg)
 
Figure 5
Control Station, 2-Gang (up to 4 devices)
  Figure 6
Control Station, 4-Gang (up to 8 devices)
Click to enlarge - 800H-2_38a-3   Click to enlarge - 800H-2_38a-4
Shipping Wt. 10 lbs (4.54 kg) Shipping Wt. 20 lbs (9.07 kg)
 
Figure 7
Control Station, 6-Gang (up to 12 devices)
  Figure 8
Control Station, 8-Gang (up to 16 devices)
Click to enlarge - 800H-2_38a-5   Click to enlarge - 800H-2_38a-6
Shipping Wt. 32 lbs (14.5 kg) Shipping Wt. 40 lbs (18.1 kg)

⋆ When using a large flange seal, an approved drain fitting must be provided (refer to National Electric Code).