Bulletin 800Z Zero-Force™ Touch Buttons
| Product Overview |
|
Bulletin 800Z — Zero-Force Touch Buttons™
Build a Catalog Number
Description
Bulletin 800Z Zero-Force Touch Buttons are ideally suited for use in two-hand machine control systems and highly repetitive applications.
Ergonomic Design — The contour shape fits the palm of the hand for ease of operation and helps deter attempts to defeat two-hand control.
Zero Force to Operate — The electronic design with two interlinked capacitive sensors in offset planes provides increased sensitivity and good ability for distinguishing between a person's hand, even through most industrial gloves, versus most foreign objects.
Features
- Internationally rated ergonomic touch buttons
- Zero force to operate
- EMC protection
- Diagnostic LEDs
- Replaceable relays (heavy industrial design)
|
ATTENTION: Not recommended for use in applications where there is high probability for exposure to liquid (e.g., cutting fluid) on the sensing surface area. |
See Specifications for Standards Compliance and Certifications.
Product Selection
General Purpose Line — Momentary Touch Buttons
|
|
|
| General Purpose Cat. No. 800Z‑GF2Q5 |
General Purpose Cat. No. 800Z‑GL3Q5B |
| Mounting Hole Size | Input Voltage | Output Type | Electrical Connection | No Guard | Black Guard |
| Cat. No. | Cat. No. | ||||
| 30.5 mm | 100...240V AC | Relay Output | 5-Pin QD | 800Z-GF3Q5 | 800Z-GF3Q5B |
| 6 ft Cabled — 5-Wire | 800Z-GF3065 | 800Z-GF3065B | |||
| 10...40V DC and 20...30V AC | Relay Output | 5-Pin QD | 800Z-GL3Q5 | 800Z-GL3Q5B | |
| 6 ft Cabled — 5-Wire | 800Z-GL3065 | 800Z-GL3065B | |||
| 22.5 mm | 100...240V AC | Relay Output | 5-Pin QD | 800Z-GF2Q5 | 800Z-GF2Q5B |
| 6 ft Cabled — 5-Wire | 800Z-GF2065 | 800Z-GF2065B | |||
| 10...40V DC and 20...30V AC | Relay Output | 5-Pin QD | 800Z-GL2Q5 | 800Z-GL2Q5B | |
| 6 ft Cabled — 5-Wire | 800Z-GL2065 | 800Z-GL2065B | |||
Use the configurator below to build a Bulletin 800Z touch button to suit your application.
| 800Z | | G | L | 3 | 065 | B | ||||
| a | b | c | d |
| a | b | c | d | |||||||
| Input Voltage and Output Type § | Mounting Hole Size ♣ | Electrical Connection | Guard Option | |||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||
| Relay Output | Sourcing Output ⋆ | |||||||||
| L | Input: 10…40V DC and 20…30V AC Output: relay |
2 | 22.5 mm | Q4 | 4-pin QD | Blank | No guard | |||
| F | Input: 100…240V AC Output: relay |
3 | 30.5 mm | 064 | 6 ft (1.8 m) cabled | B | Black guard | |||
| Transistor Output | 244 | 24 ft (7.2 m) cabled | Y | Yellow guard | ||||||
| P | 10…30V DC PNP (sourcing) output |
Relay Output | ||||||||
| Q5 | 5-pin QD | |||||||||
| 065 | 6 ft (1.8 m) cabled | |||||||||
| 245 | 24 ft (7.2 m) cabled | |||||||||
⋆ These devices are transistor outputs.
These devices have separate N.O. and N.C. output relays with a shared common.
§ Safety relays should be used in conjunction with two relay output type Zero-Force Touch Buttons™ in 2-hand control applications. Order separately, safety relay 440R-D23171 for 24V, 440R-D23169 for 120V, 440R-D23168 for 240V.
♣ 22.5 mm touch buttons use micro connector, 30.5 mm touch buttons use mini connector.
Heavy Industrial Line — Momentary Touch Buttons
|
|
|
| Heavy Industrial Cat. No. 800Z‑HF1 |
Heavy Industrial Cat. No. 800Z‑HL1Y |
| Button Type | Input Voltage | Output Type | Electrical Connection | No Guard | Yellow Guard |
| Cat. No. | Cat. No. | ||||
| Flush Mount | 10...40V DC and 20...30V AC | Relay Output | Terminal Block | 800Z-HL1 | 800Z-HL1Y |
| 100...240V AC | Relay Output | Terminal Block | 800Z-HF1 | 800Z-HF1Y | |
Use the configurator below to build a Bulletin 800Z touch button to suit your application.
| 800Z | | H | L | 1 | Y | |||
| a | b | c |
| a | b | c | |||||
| Voltage | Mounting Type ⋆ | Guard Option | |||||
| Code | Description | Code | Description | Code | Description | ||
| L | Input: 10…40V DC and 20…30V AC Output: relay |
1 | Flush mounting | Blank | No guard | ||
| F | Input: 100…240V AC Output: relay |
Y | Yellow guard | ||||
⋆ Heavy industrial devices have an 8-position terminal block connection. See wiring diagrams on Heavy Industrial Line for details.
Safety relays should be used in conjunction with two relay output type Zero-Force Touch Buttons in 2-hand control applications. Order separately, safety relay 440R-D23171 for 24V, 440R-D23169 for 120V, 440R-D23168 for 240V.
Quick Disconnect Cables
|
|
|
| PD | PD |
| 889 | D | | F | 4A | C-2 | |||
| a | b | c | d |
| a | b | c | d | |||||||
| Mounting Hole Size | QD Type | Pin Style | Cable Length/Type | |||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||
| D | 22.5 mm (micro) | F | Straight QD cable | 4A | 4 pin | C-2 | 2 m (micro) | |||
| N | 30.5 mm (mini) | R | Right angle QD cable | 5A | 5 pin § | C-5 | 5 m (micro) | |||
| C-10 | 10 m (micro) | |||||||||
| E-6F | 6 ft. (mini) | |||||||||
| E-12F | 12 ft. (mini) | |||||||||
| E-20F | 20 ft. (mini) | |||||||||
§ No right angle QD cable (micro) for 5-pin (Cat. No. 889D-R5A_).
Accessories
Accessories — General Purpose
Accessories — Heavy Industrial
Wiring Diagrams — Touch Button Terminations
General Purpose Line
Electrical Connections: 10...40V DC and 20...30V AC Input Voltage (Relay Output); 100...240V AC Input Voltage (Relay Output)
Note: Separate N.O. and N.C. output relays with shared common.
5-Conductor Cabled (Relay Output)
For 800Z-GL_ _ _
For 800Z-GF_ _ _
|
Electrical Connections: 10...30V DC Input Voltage (Transistor Output); 150 mA Max. per Circuit Output
4-Conductor Cabled
|
Heavy Industrial Line
|
Specifications
Mechanical Ratings
| Description | General Purpose Line (800Z-G) |
Heavy Industrial Line (800Z-H) |
| Mechanical Ratings | ||
| Vibration Endurance | Tested @ 10 G, 1.52 mm displacement | |
| Mechanical Shock | Tested @ 100 G (mechanical durability) | |
| Degree of Protection |
Type 4/4X/13 IP66 1200 psi Washdown |
Type 4/13 IP66 |
| Operating Force | Zero | |
| Electrical Ratings | ||
| Input Voltage (Relay type) |
Low Voltage: 10…40V DC, 20…30V AC Full Voltage (800Z-GF): 100…240V AC (+10%, -15%) |
|
| Input Voltage (Solid-State type) |
Low Voltage (800Z-GN/GP): 10…30V DC | |
| Electrical Design Life (Relay type) |
Relay output 200 000 Operations @ 2 A inductive 4 A resistive |
Relay output 150 000 Operations @ 5 A inductive 2.5 A resistive |
| Degree of Protection | — | IP2X |
| Wire Range | #22…12 AWG (0.5…4 mm2) |
|
| Tightening Torque | 9 lbin (1 Nm) | |
| On-delay/Off-delay | Off 60 ms max. On 76 ms max. | |
| Current Draw (Solid-State type) |
100 mA at 24V DC = 2.23 W (no external load) | |
| Environmental | ||
| Temperature Range (Operating) |
-25...+55 °C (-13…+131 °F) | |
| Temperature Range (Storage) |
-40...+85 °C (-40…+185 °F) | |
| Humidity | 95% RH from 25...50 °C (77…122 °F) (full operation) | |
| Materials | ||
| Housing/Guard | Valox 357 | |
| Gasket | BUNA-N | 1/16 in. Cork-BUNA-N |
| Connector | Insulator material (micro connector) = nylon Insulator material (mini connector) = PVC |
|
| Standards and Certifications | ||
| Certifications | cULus, CE, C-TICK, CSA | |
| Standards Conformity |
UL 508, CSA 22.2 No. 14, EN/IEC 60947-5-1, EN50081-2, EN61000-6-2, EN60954-1, EN60204-1 |
|
Load Life Curves for General Purpose Product Line
|
|
Load Life Curves for Heavy Industrial Line
|
|
Applications Detail
| LED Blink Rate | Diagnostic | Description |
| ** ** ** | Power Up | Device touched during power up. Device will resume 10 seconds after removal of hand. |
| *** *** *** | Noise Detection | Device detected an unacceptable level of noise (>20 V/m). Device will resume once noise subsides. |
| **** **** **** | Margin Detection | A conductive film is building up on the sensing surface. Device will resume once cleared. |
Approximate Dimensions
Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
General Purpose
|
General Purpose With Guard
|
|
Heavy Industrial
|
|
Heavy Industrial With Guard
|
|
Cutout and Mounting Screw Locations for a Flush Mounted Cover
|