Bulletin 800P Palm-Operated Push Buttons

Product Overview


Click to enlarge - 800P-2_21-1


Bulletin 800P — Palm-Operated Push Buttons

Build a Catalog Number

The Bulletin 800P palm-operated push button is designed for applications requiring electromechanical operation for safety, resistance to RFI, and an ergonomically sensitive design to reduce risk factors associated with cumulative trauma disorders. Bulletin 800P units with articulated operation offer reduced operating force over standard drive units by permitting the button head to tilt for added comfort and mechanical advantage. Bulletin 800P operators are intended for applications requiring two-hand control wiring, per OSHA standards.

Standards Compliance and Certifications

UL 508
CSA 22.2, No 14
UL Listed —File: E14840
Guide: NKCR
CSA Certified: LR1234
CE Compliant


Product Selection

Palm-Operated Push Buttons

Click to enlarge - 800P-2_22-1   Click to enlarge - 800P-2_22-2
Palm-Operated Flush Mount Button
Cat. No. 800P‑F2CA
Palm-Operated Surface Mount with Guard
Cat. No. 800P‑S2CG1A

Operation Type Contact Type Guard Option Flush Mounting Surface Mounting
Cat. No. Cat. No.
Articulated 1 N.O. - 1 N.C. None 800P-F2CA 800P-S2C1A
Guard 800P-F2CGA 800P-S2CG1A
2 N.O. - 2 N.C. None 800P-F2CB 800P-S2C1B
Guard 800P-F2CGB 800P-S2CG1B
Standard Drive 1 N.O. - 1 N.C. None 800P-F1CA 800P-S1C1A
Guard 800P-F1CGA 800P-S1CG1A
2 N.O. - 2 N.C. None 800P-F1CB 800P-S1C1B
Guard 800P-F1CGB 800P-S1CG1B
  

Click to enlarge - 800P-2_22-3


800P S    1    C    G    1    A
     a    b    c    d    e    f

a    b    c    d    e    f
Operator Type Button Operation Button Color Guard Option Enclosure Openings Contact Black
Standard
Code Description Code Description Code Description Code Description Code Description Code Description
F Flush mount 1 Standard drive C Chrome Blank No guard Blank No base⋆  A 1 N.O. - 1 N.C.
S Surface mount 2 Articulated R Red (painted) G Side guard — yellow 1 Single hub B 2 N.O. - 2 N.C.
    Y Yellow (painted) H Die cast — grey 2 Double hub PenTUFF (Low Voltage)
      Code Description
AV 1 N.O. - 1 N.C.
BV 2 N.O. - 2 N.C.

⋆ Only used for flush mounted operators.


Accessories

  Description Button Color Cat. No. Cat. No.
Standard Anti-Slip
Click to enlarge - 800P-2_23-1 Click to enlarge - 800P-2_23-2 Button Covers
Button covers are used to reduce possible slipping due to fluids on the operator.
Red 800P-NCR 800P-NCR1
Black 800P-NCB 800P-NCB1
Green 800P-NCG 800P-NCG1
Standard Button Cover
Cat. No. 800P‑NCB
Anti-Slip Button Cover
Cat. No. 800P‑NCG1
Yellow 800P-NCY 800P-NCY1
  Description Style Color Cat. No.
Click to enlarge - 800P-2_23-3 Click to enlarge - 800P-2_23-4 Guards
These guards prevent accidental activation of the button and protect it from damage.
Note:Guards are required in most two hand safety applications (See OSHA and ANSI standards).
Side Yellow 800P-NBG1
Die Cast Grey 800P-NBG
Side Guard
Cat. No. 800P‑NBG1
Die Cast Guard
Cat. No. 800P‑NBG
Die Cast Yellow 800P-NBGY
  Description Style Cat. No.
Click to enlarge - 800P-2_23-5 Click to enlarge - 800P-2_23-6 Bases
The conduit hub(s) on these replacement mounting bases come with a 3/4 in. opening.
Single Hub 800P-B1
Single Hub Base
Cat. No. 800P‑B1
Double Hub Base
Cat No. 800P‑B2
Double Hub 800P-B2
  Description Enclosure Cat. No.
Click to enlarge - 800P-2_23-7 Click to enlarge - 800P-2_23-8 Adaptors
These adaptor flanges are used between the operator and the mounting base, when using a non-Allen-Bradley base.
Standard⋆  800P-N150
Standard Adapter
Cat. No. 800P‑N150
FS Adaptor
Cat. No. 800P‑N4
FS 800P-N4
  Description Marking Cat. No.
Click to enlarge - 800P-2_23-9 Legend Plates
These legend plates can be mounted on the cover.
Blank (Grey) 800P-X107‡ 
Blank (Red) 800P-X129‡ 
START 800P-X130
STOP 800P-X131
INCH 800P-X132
RUN 800P-X133
RUN
INCH
800P-X134
Legend Plates TOP
STOP
800P-X135
  
⋆ Horizontal mounting holes are 2-3/8 in. (60.3 mm) center-to-center. Vertical mounting holes are 4-1/2 in. (114.3 mm) center-to-center.
‡ To order with custom engraved text, add suffix E and supply text. One or two lines of text with maximum of 5 characters per line.

Contact Blocks

Packaged in a kit form for field installation. All necessary mounting hardware is provided with each contact block kit. Contact ratings are listed on Standard Contact Ratings.
Note:It is recommended to mount no more than four contact blocks on any one unit (maximum two blocks deep).


  Click to enlarge - 800T_800H-1_30-1 Click to enlarge - 800T_800H-1_30-2 Click to enlarge - 800T_800H-1_30-3
Contact Type Shallow Block‡  PenTUFF Block‡  Logic Reed Block§ 
Cat. No. Cat. No. Cat. No.
1 N.O. 800T-XD1 800T-XD1V 800T-XD1R
1 N.C. 800T-XD2 800T-XD2V 800T-XD2R
1 N.O. - N.C. 800T-XA 800T-XAV 800T-XAR
  
Note:Contact blocks with normally closed contacts meet direct drive positive opening standard requirements.
§ Logic Reed blocks can be physically mounted on a Bul. 800P operator, but this combination is not UL Listed for Class 1 Div 2 hazardous applications.
‡ For contact ratings, see Standard Contact Ratings.

Specifications

Specifications⋆ 

Electrical Ratings
Dielectric Strength 2200V for one minute
Electrical Design Life Cycles 1 000 000 at maximum rated load
200 000 at maximum rated load (Logic Reed)
Mechanical Ratings
Vibration 10…2000 Hz 1.52 mm displacement (peak-to-peak) 10 G max.
Shock Mechanical shock at 1/2 cycle sine wave for 11 ms
Contact Fragility 25 G
9 G
6 G
800T-XA1, -XA2, -XD1, -XD4, -XD2R, contact blocks
800T-XA, -XA4, -XD2, -XD3, -XAR, -XAV contact blocks
800T-XD1R
No damage at 100 G all contact blocks
Degree of Protection Type 1, 12, 4/13; watertight/oiltight 529 IP65
Mechanical Design Life Cycles Push Buttons 1 000 000 minimum
Contact Operation Shallow Contact Block
Logic Reed
Slow, double make and break
Snap action
Typical Operating Forces Articulated 800T-XD1 and 800T-XD4 contact blocks
3.7 lb maximum at center of button, 2.7 lb at perimeter
Standard Drive 3.7 lb
Environmental
Temperature Range Operating
Storage
+32…+131 °F (0…+55 °C)
-40…+185 °F (-40…+85 °C)
Note: Operating temperatures at 0 °C (32 °F) are based on the absence of freezing moisture and liquids.
  
⋆ Performance Data — See Performance Data.

Standard Contact Ratings

(IEC 947-5-1) (NEMA ICS 2-125) Maximum continuous current Ith
10 A. Bulletin 800P units have control circuit ratings with 800T-XA1, -XD1, -XD4, -XA2, -XA, -XA4, -XD2, and -XD3 contact blocks as follows:


Maximum
Operational
Volts Ue
Utilization Category Rated Operational Currents
IEC NEMA Volts Ue Make Break
Click to enlarge - 800P-2_21-2 Click to enlarge - 800P-2_21-3
AC 600 AC-15 A600 120…600
72…120
24…72
7200VA
60 A
60 A
720VA
720VA
10 A
DC 600 DC-13 Q600 28…600
24…28
69VA
2.5 A
  
(See Contact Blocks for 800T-XAR, -XD1R, -XD2R data.)

PenTUFF™ (Low Voltage) Contact Ratings

Minimum DC: 5V, 1 mA. Maximum thermal continuous current Ith 2.5 A AC/1.0 A DC. Bulletin 800P units with Cat. No. 800T‑XAV contacts have ratings as follows:

Maximum
Operational
Volts Ue
Utilization Category Rated Operational Currents
IEC NEMA Volts Ue Make Break
Click to enlarge - 800P-2_21-2 Click to enlarge - 800P-2_21-3
AC 300 AC-15 C300 120…300
0…120
1800VA
15 A
180VA
1.5 A
DC 150 DC-13 R150 24…150
0…24
28VA
1.0 A
  

Approximate Dimensions

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Flush Mounting

Click to enlarge - 800P-2_24-4   Click to enlarge - 800P-2_24-5

Surface Mounting

Click to enlarge - 10_177_800P_dim   Click to enlarge - 800P-2_24-7

Die Cast Guard (800P-NBG or 800P-NBGY)

Click to enlarge - 800P-2_24-8


Cutout and mounting screw locations for a flush mounted cover

Click to enlarge - 800P-2_24-9