Pendant Stations
| Product Overview |
Bulletin 800FC — Configured Pendant Stations
|
Build a Catalog Number
Bulletin 800FC — Pendant Stations
- 3-, 5-, 7-, and 9-button configurations
- 1-, 2-, and 3-speed push buttons
- IP66, NEMA Type 4/4X/13
- Finger-safe contact blocks
- Buttons are flush-mounted with the enclosure to reduce accidental operation
- Use of standard Bul. 800F extended push buttons
- Electrical and mechanical interlocks
Bulletin 800FP — 1-, 2-, and 3-Speed Operators
- IP65/IP66, NEMA Type 4/4X/13
- Engineering grade thermoplastics
- Chemical-resistant for harsh environments
- Booted operator
Mechanical Interlock
- 1-, 2-, and 3-speed operators
- Screw-down mounting
- 3-across x 1 deep contact blocks
- Snap-down contact blocks
- Bifurcated and QuadConnect™ contact blocks
- Color-coded contact blocks
Standards Compliance and Certifications
Product Certifications
| Certifications | UR/UL, CSA, CCC, CE |
| Standards Compliance | NEMA ICS-5, UL 508, CSA C22.2 No. 14, EN ISO 13850, EN 60947‑1, EN 60947‑5‑1, EN 60947‑5‑5 |
| Terminal Identification | EN/IEC 60947-1 |
| RoHS | ü |
Operator Mounting & Sequence
Operator Mounting - Vertical vs. Horizontal Definition
Due to the design of the enclosures, operators are mounted in both a vertical and horizontal orientation. The easiest way to visualize the operator orientation is by observing the contact block direction attached to the operators . If the contact blocks are mounted vertically the operator is mounted vertically in the enclosure. Vertical mounted operators are only found in position 2 & 3 of the 3-hole enclosure. If the contact blocks are mounted horizontally the operator is mounted horizontally in the enclosure. Horizontal mounted operators are found in position 1 of the 3-hole enclosure and all positions of the 5-...9-hole enclosures. It is necessary to know this when ordering individual operators for populating at the customer location.
Operator Sequence when using a Mechanical Interlock
The 1-, 2-, and 3-speed operators can be mounted with either our standard Cat. No. 800F‑ALP latch or a mechanical interlocking latch (Cat. No. 800FC‑ALP).
For the 3-hole enclosure, the mechanical interlock can only be located in positions 2 & 3, with the black operator being located in position 2 and the white operator being located in position 3.
For the 5-…9-hole enclosures, the mechanical interlock can be located in any two adjacent positions. For the 5-…9-hole enclosures, the white operator will be located in position X of the mechanical interlock and the black operator will be located in position X+1 of the mechanical interlock.
Operator Assembly Sequence and Mounting Orientation
| Vertical Mount Operators | Horizontal Mount Operators | |
|
|
Catalog Number Explanation
Configured Pendant Stations
| 800FC | | |||||||||||||||||||||||||||||||||||||
| a | b | b1 | c | c1 | d | d1 | e | e1 | f | f1 | g | g1 | h | h1 | j | j1 | k | k1 | ||||||||||||||||||||
| Pos. 1 | Pos. 2 | Pos. 3 | Pos. 4 | Pos. 5 | Pos. 6 | Pos. 7 | Pos. 8 | Pos. 9 | ||||||||||||||||||||||||||||||
| 3-…9-hole | 5-…9-hole | |||||||||||||||||||||||||||||||||||||
Note:A code from Tables b…k and b1…k1 must be specified for each operator to create a valid cat. no.
| a | |||||
| Enclosure Code | |||||
| Voltage | Legend Plate | 3-Hole | 5-Hole | 7-Hole | 9-Hole |
| Code | Code | Code | Code | ||
| 24V AC/DC | No | 2 | 4 | 6 | 8 |
| 120V AC | 3 | 5 | 7 | 9 | |
| 24V AC/DC | Yes | A | C | E | G |
| 120V AC | B | D | F | H | |
| b…k | |||
| Operator Type | |||
| Single Speed Operators for use with Mechanical Interlock§ ∇ & ※ | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| A2 | Black operator (no text or symbol) | Blank | |
| AB | Black operator with arrow (reverse — down/left) | O/H CRANE, REVERSE | |
| AD | Black operator with arrow (down) | LIFT, DOWN | |
| AL | Black operator with arrow (left) | HOIST, LEFT | |
| A1 | White operator (no text or symbol) | Blank | |
| AF | White operator with arrow (forward — up/right) | O/H CRANE, FORWARD | |
| AR | White operator with arrow (right) | HOIST, RIGHT | |
| AU | White operator with arrow (up) | LIFT, UP | |
| Fast Single Speed Operators for use with Mechanical Interlock§ ∇ & ※ | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| DB | Black operator with double arrow (reverse fast — down/left) | O/H CRANE, REVERSE, FAST | |
| DD | Black operator with double arrow (down fast) | LIFT, DOWN FAST | |
| DL | Black operator with double arrow (left fast) | O/H CRANE, LEFT FAST | |
| DF | White operator with double arrow (forward fast — up/right) | O/H CRANE, FORWARD, FAST | |
| DR | White operator with double arrow (right fast) | O/H CRANE, RIGHT FAST | |
| DU | White operator with double arrow (up fast) | LIFT, UP FAST | |
| Two-Speed Operators for use with Mechanical Interlock§ ∇ & ※ | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| B2 | Black operator (no text or symbol) | Blank | |
| BB | Black operator with arrow (reverse — down/left) | 1-2 SPEED, O/H CRANE, REVERSE | |
| BD | Black operator with arrow (down) | 1-2 SPEED, LIFT, DOWN | |
| BL | Black operator with arrow (left) | 1-2 SPEED, HOIST, LEFT | |
| B1 | White operator (no text or symbol) | Blank | |
| BF | White operator with arrow (forward — up/right) | 1-2 SPEED, O/H CRANE, FORWARD | |
| BR | White operator with arrow (right) | 1-2 SPEED, HOIST, RIGHT | |
| BU | White operator with arrow (up) | 1-2 SPEED, LIFT, UP | |
| Three-Speed Operators for use with Mechanical Interlock§ ♣ ∆ ∇ & ※ | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| C2 | Black operator (no text or symbol) | Blank | |
| CB | Black operator with arrow (reverse — down/left) | 1-2-3 SPEED, O/H CRANE, REVERSE | |
| CD | Black operator with arrow (down) | 1-2-3 SPEED, LIFT, DOWN | |
| CL | Black operator with arrow (left) | 1-2-3 SPEED, HOIST, LEFT | |
| C1 | White operator (no text or symbol) | Blank | |
| CF | White operator with arrow (forward — up/right) | 1-2-3 SPEED, O/H CRANE, FORWARD | |
| CR | White operator with arrow (right) | 1-2-3 SPEED, HOIST, RIGHT | |
| CU | White operator with arrow (up) | 1-2-3 SPEED, LIFT, UP | |
| Emergency Stop Operators⋆ ∆ ♦ ♠ ∇ & | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| MT | Red operator — twist-to-release | Not provided | |
| ME | Illuminated red operator — twist-to-release | ||
| MK | Red operator — keyed twist-to-release | ||
| MM | Red operator — twist-to-release/push-pull | ||
| MG | Red operator with guard — twist-to-release/push-pull | ||
| Standard Extended Push Buttons — Non-Illuminated♦ ♠ | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| E2 | Black operator (no text or symbol) | Blank | |
| ED | Black operator with arrow (down) | LIFT, DOWN | |
| EL | Black operator with arrow (left) | HOIST, LEFT | |
| EB | Black operator with arrow (reverse — down/left) | O/H CRANE, REVERSE | |
| FD | Black operator with double arrow (down fast) | LIFT, DOWN FAST | |
| FL | Black operator with double arrow (left fast) | O/H CRANE, LEFT FAST | |
| FB | Black operator with double arrow (reverse fast — down/left) | O/H CRANE, REVERSE, FAST | |
| E1 | White operator (no text or symbol) | Blank | |
| EU | White operator with arrow (up) | LIFT, UP | |
| ER | White operator with arrow (right) | HOIST, RIGHT | |
| EF | White operator with arrow (forward — up/right) | O/H CRANE, FORWARD | |
| FU | White operator with double arrow (up fast) | LIFT, UP FAST | |
| FR | White operator with double arrow (right fast) | O/H CRANE, RIGHT FAST | |
| FF | White operator with double arrow (forward fast — up/right) | O/H CRANE, FORWARD, FAST | |
| E3 | Green operator (no text or symbol)∆ & | Blank | |
| EQ | Green operator with Start/Alarm symbol∆ & | START, ALARM | |
| EN | Green operator with Start symbol∆ & | START | |
| E4 | Red operator (no text or symbol)∆ & | Blank | |
| ES | Red operator with Stop symbol∆ & | STOP | |
| E5 | Yellow operator (no text or symbol)∆ & | Blank | |
| EA | Yellow operator with Alarm symbol∆ & | ALARM | |
| E6 | Blue operator (no text or symbol)∆ & | Blank | |
| R6 | Blue operator with R∆ & | RESET | |
| Standard Extended Push Buttons — Illuminated∆ ♦ ♠ & | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| L3 | Green operator (no text or symbol) | Blank | |
| L4 | Red operator (no text or symbol) | Blank | |
| L5 | Yellow operator (no text or symbol) | Blank | |
| L6 | Blue operator (no text or symbol) | Blank | |
| L7 | Clear operator (no text or symbol) | Blank | |
| Selector Switches∆ ♦ ♠ ∇ & | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| SH | 2-position | Standard-maintained | O-I |
| KH | Keyed-maintained | ||
| SJ | 3-position | Standard-maintained | I-O-II |
| KJ | Keyed-maintained | ||
| 2- Function Multi-Operator Push Buttons∆ ♦ ♠ & | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| VV | Black/white operator with arrow (down & up) | Not provided | |
| VW | Black/white operator with arrow (left & right) | ||
| VX | Black/white operator with arrow (reverse & forward) | ||
| WV | Black/white operator, illuminated, with arrow (down & up) | ||
| WW | Black/white operator, illuminated, with arrow (left & right) | ||
| WX | Black/white operator, illuminated, with arrow (reverse & forward) | ||
| XV | Black/white operator with double arrows (down fast & up fast) | ||
| XW | Black/white operator with double arrows (left fast & right fast) | ||
| XX | Black/white operator with double arrows (reverse fast & forward fast) | ||
| YV | Black/white operator, illuminated, with double arrows (down fast & up fast) | ||
| YW | Black/white operator, illuminated, with double arrows (left fast & right fast) | ||
| YX | Black/white operator, illuminated, with double arrows (reverse fast & forward fast) | ||
| Pilot Lights ∆ ♦ ♠ ∇ & | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| P0 | Amber LED | Blank | |
| P3 | Green LED | Blank | |
| P4 | Red LED | Blank | |
| P5 | Yellow LED | Blank | |
| P6 | Blue LED | Blank | |
| P7 | Clear LED | Blank | |
| Potentiometers∆ ♦ ♠ ∇ & ♯ | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| 1P | Black operator — 150 W | Blank | |
| 2P | Black operator — 500 W | Blank | |
| 3P | Black operator — 1000 W | Blank | |
| 4P | Black operator — 2500 W | Blank | |
| 5P | Black operator — 5000 W | Blank | |
| 6P | Black operator — 10 000 W | Blank | |
| Hole Plug∆ ♦ ♠ ∇ & | |||
| Code | Description | Legend Plate Text (When Selected) |
|
| N2 | Black hole plug | Blank | |
| b1…k1 | |
| Interlock and/or Rubber Boot | |
| Code | Description |
| N | No interlock, no additional boots |
| E | Electrical interlock, no additional boots |
| M | Mechanical interlock, boots standard§ |
| B | Electrical and mechanical interlock, boots standard§ |
| R | No interlock, additional rubber boot |
| S | Electrical interlock, additional rubber boot |
| ⋆ Only available in position 1 of a 3-hole enclosure and in positions 1 & 2 of a 5-…9-hole enclosure. |
| Monolithic style device provided. |
| § For a 3-hole enclosure, when a mechanical interlock (c1 & d1 = M or B) is selected with a 1-…3-speed operator, the black operator will be located in position 2 of the enclosure and the opposite white operator will be placed in position 3 of the enclosure (Example: ABMAFM or BDMBUM). For a 5-...9-hole enclosure, when a mechanical interlock (b1…k1 = M or B) is selected with a 1-…3-speed operator, the white operator will be located in position X of the mechanical interlock and the opposite black operator will be placed in position X+1 of the mechanical interlock (Example: AFMABM or BUMBDM). |
| ♣ Interlock and/or rubber boot selection = N (no interlock, no additional boots) is not allowed. |
| ∆ Interlock and/or rubber boot selection = E (electrical interlock, no additional boots) is not allowed. |
| ♦ Interlock and/or rubber boot selection = M (mechanical interlock) is not allowed. |
| ♠ Interlock and/or rubber boot selection = B (electrical and mechanical interlock) is not allowed. |
| ∇ Interlock and/or rubber boot selection = R (no interlock, additional rubber boot) is not allowed. |
| & Interlock and/or rubber boot selection = S (electrical interlock, additional rubber boot) is not allowed. |
| ♯ Only available in position 1 for a 3-hole enclosure, positions 1 and/or 5 for a 5-hole enclosure, positions 1 and/or 7 for a 7-hole enclosure, and positions 1 and/or 9 for a 9-hole enclosure. |
| ※ For proper installation, a trim washer or Cat. No. 800F-36_ legend plate must be installed with this operator. |
Product Selection
Enclosures
|
|
|
|
| Cat. No. 800FC-3Z | Cat. No. 800FC-7Z |
| Enclosure Type | Pkg. Quantity | Pendants — Yellow Plastic IP66 Cat. No.⋆ |
| 3-hole | 1 | 800FC-3Z |
| 5-hole | 800FC-5Z | |
| 7-hole | 800FC-7Z | |
| 9-hole | 800FC-9Z | |
| ⋆ Housings supplied with cable sleeve, hanger ring, cable clamp, wire guides, and gasket. | ||
1-, 2-, and 3-Speed Operators ♣ ∆
|
| 800FP | | C | A | 1 | U243 | |||
| a | b | c |
| a | |
| Operator Type | |
| Code | Description |
| A | 1-speed single arrow |
| D | 1-speed double arrow |
| B | 2-speed |
| C | 3-speed |
Proper contact block assembly of these devices is required. Please see contact block information on page1-, 2-, and 3-Speed Contact Block Assemblies.
| b | |
| Cap Color | |
| Code | Description |
| 1 | White |
| 2 | Black |
Note:Please see page1-, 2-, and 3-Speed Contact Block Assemblies for proper latch and contact block configurations.
§ Text (DOWN, UP, LEFT, etc.) indicates arrow direction. Text is not printed on operators.
♣ Cat. No. 800F-ALP (standard latch) and Cat. No. 800FC-ALP (mechanical interlock latch) can be used with these operators.
∆ Booted style of operators for pendant stations.
Arrow Direction Chart
|
Bul. 800F Two-Position Twist-to-Release and Twist-to-Release/Push-Pull Operators
|
| Description | Operator Cat. No. | Guard Cat. No. |
| Twist-to-release — Red | 800FP-MT44PX01 | — |
| Twist-to-release — Red, illuminated | 800FP-LMT44PN♣ RX01 | — |
| Keyed twist-to-release — Red | 800FP-MK44PX01 | — |
| Twist-to-release or push-pull — Red, monolithic | 800FD-MT44X01 | — |
| Twist-to-release or push-pull — Red, monolithic with guard, monolithic | 800FD-MT44X01 | 800F-AMEGY |
| ♣ Select 3 for 24V AC/DC or 5 for 120V AC. | ||
Bul. 800F Push Button Operators and Caps — Extended & Non-Illuminated ⋆
|
| Cap Color | Description | Symbol Definition | Operator Cat. No. |
Cap Cat. No. | Complete Operator Cat. No. | Composite Cat. No./ No Electrical Interlock | Composite Cat. No./ Electrical Interlock |
| Black | Blank | — | 800FP-E2 | — | — | 800FP-E2PX10 | 800FP-E2PX11 |
| LEFT or DOWN | Single arrow 0° | 800FP-E9 | 800F-AE208 | 800FP-E208 | 800FP-E208PX10 | 800FP-E208PX11 | |
| REVERSE | Single arrow 45° | 800F-AE2CU244 | 800FP-E2U244 | 800FP-E2U244PX10 | 800FP-E2U244PX11 | ||
| LEFT FAST or DOWN FAST | Double arrow 0° | 800F-AE2CU261 | 800FP-E2U261 | 800FP-E2U261PX10 | 800FP-E2U261PX11 | ||
| REVERSE FAST | Double arrow 45° | 800F-AE2CU264 | 800FP-E2U264 | 800FP-E2U264PX10 | 800FP-E2U264PX11 | ||
| White | Blank | — | 800FP-E1 | — | — | 800FP-E1PX10 | 800FP-E1PX11 |
| UP or RIGHT | Single arrow 0° | 800FP-E9 | 800F-AE108 | 800FP-E108 | 800FP-E108PX10 | 800FP-E108PX11 | |
| FORWARD | Single arrow 45° | 800F-AE1CU244 | 800FP-E1U244 | 800FP-E1U244PX10 | 800FP-E1U244PX11 | ||
| UP FAST or RIGHT FAST | Double arrow 0° | 800F-AE1CU261 | 800FP-E1U261 | 800FP-E1U261PX10 | 800FP-E1U261PX11 | ||
| FORWARD FAST | Double arrow 45° | 800F-AE1CU264 | 800FP-E1U264 | 800FP-E1U264PX10 | 800FP-E1U264PX11 | ||
| Green | Blank | — | 800FP-E3 | — | — | 800FP-E3PX10 | — |
| START/ALARM | Start/Alarm | 800FP-E9 | 800F-AE3CU222 | 800FP-E3U222 | 800FP-E3U222PX10 | ||
| START | Start symbol | 800F-AE3CU909 | 800FP-E3U909 | 800FP-E3U909PX10 | |||
| Red | Blank | — | 800FP-E4 | — | — | 800FP-E4PX10 | |
| STOP | Stop symbol | 800FP-E9 | 800F-AE405 | 800FP-E405 | 800FP-E405PX10 | ||
| Yellow | Blank | — | 800FP-E5 | — | — | 800FP-E5PX10 | |
| ALARM | Alarm | 800FP-E9 | 800F-AE5CU223 | 800FP-E5U223 | 800FP-E5U223PX10 | ||
| Blue | Blank | — | 800FP-E6 | — | — | 800FP-E6PX10 | |
| R | Reset symbol | 800FP-E9 | 800F-AE611 | 800FP-E611 | 800FP-E611PX10 | ||
| For 24V AC/DC units, add V for low voltage contact blocks. Example: Cat. No. 800FP-E5PX10 becomes Cat. No. 800FP-E5PX10V. | |||||||
| ⋆ Mechanical interlock is not allowed. | |||||||
Bul. 800F Push Button Operators — Extended & Illuminated ⋆
|
| Lens Color | Operator Cat. No. | Composite Cat. No. |
| Green | 800FP-LE3 | 800FP-LE3PN♣ GX10 |
| Red | 800FP-LE4 | 800FP-LE4PN♣ RX10 |
| Yellow | 800FP-LE5 | 800FP-LE5PN♣ WX10 |
| Blue | 800FP-LE6 | 800FP-LE6PN♣ BX10 |
| Clear | 800FP-LE7 | 800FP-LE7PN♣ WX10 |
| ♣ Select 3 for 24V AC/DC or 5 for 120V AC. | ||
| ⋆ Mechanical interlock is not allowed. | ||
Bul. 800F Selector Switch Operators — Maintained & Non-Illuminated
|
| Number of Positions | Keyed | Operator Cat. No. | Composite Cat. No. |
| 2 | No | 800FP-SM22 | 800FP-SM22PX11 |
| Yes | 800FP-KM21 | 800FP-KM21PX11 | |
| 3 | No | 800FP-SM32 | 800FP-SM32PX20 |
| Yes | 800FP-KM34 | 800FP-KM34PX20 | |
| For 24V AC/DC units, add V for low voltage contact blocks. Example: Cat. No. 800FP-E5PX10 becomes Cat. No. 800FP-E5PX10V. | |||
Bul. 800F Multi Operators and Caps— Extended § ⋆
|
|
|
|
|||
| Vertical Mounting | Horizontal Mounting | |||||
| Description | Symbol Definition | Illumination | Operator Cat. No. | Position A Cap Cat. No. |
Position C Cap Cat. No. |
Back of Panel Cat. No. |
| Blank (black and white cap) | — | Non-Illuminated | 800FP-U2X | 800F-AEU2 | 800F-AEU1 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| Vertical Mounting | ||||||
| UP (white)/DOWN (black) | Single arrow 0° | Non-Illuminated | 800FP-U2X | 800F-AECU2CU241 | 800F-AECU1CU241 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| RIGHT (white)/LEFT (black) | Single arrow 90° | Non-Illuminated | 800FP-U2X | 800F-AECU2CU700 | 800F-AECU1CU700 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| FORWARD (white)/REVERSE (black) | Single arrow 45° | Non-Illuminated | 800FP-U2X | 800F-AECU2CU244 | 800F-AECU1CU244 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| UP FAST (white)/DOWN FAST (black) | Double arrow 0° | Non-Illuminated | 800FP-U2X | 800F-AECU2CU261 | 800F-AECU1CU261 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| RIGHT FAST (white)/LEFT FAST (black) | Double arrow 90° | Non-Illuminated | 800FP-U2X | 800F-AECU2CU260 | 800F-AECU1CU260 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| FORWARD FAST (white)/REVERSE FAST (black) | Double arrow 45° | Non-Illuminated | 800FP-U2X | 800F-AECU2CU264 | 800F-AECU1CU264 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| Horizontal Mounting | ||||||
| LEFT (black)/RIGHT (white) | Single arrow 90° | Non-Illuminated | 800FP-U2X | 800F-AECU1CU241 | 800F-AECU2CU241 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| DOWN (black)/UP (white) | Single arrow 0° | Non-Illuminated | 800FP-U2X | 800F-AECU1CU242 | 800F-AECU2CU242 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| REVERSE (black)/FORWARD (white) | Single arrow 45° | Non-Illuminated | 800FP-U2X | 800F-AECU1CU245 | 800F-AECU2CU245 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| LEFT FAST (black)/UP FAST (white) | Double arrow 90° | Non-Illuminated | 800FP-U2X | 800F-AECU1CU261 | 800F-AECU2CU261 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| DOWN FAST (black)/UP FAST (white) | Double arrow 0° | Non-Illuminated | 800FP-U2X | 800F-AECU1CU262 | 800F-AECU2CU262 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| REVERSE FAST (black)/FORWARD FAST (white) | Double arrow 45° | Non-Illuminated | 800FP-U2X | 800F-AECU1CU265 | 800F-AECU2CU265 | 800F-PX20 |
| Illuminated | 800FP-LU2X | 800F-PN♣ WX20 | ||||
| ♣ Select 3 for 24V AC/DC or 5 for 120V AC. | ||||||
| For 24V AC/DC units, add V for low voltage contact blocks. Example: Cat. No. 800F-PX20 becomes Cat. No. 800F-PX20V | ||||||
| § Electrical interlock cannot be performed within the pendant enclosure. | ||||||
| ⋆ Mechanical interlock is not allowed. | ||||||
Bul. 800F Pilot Lights — Monolithic
|
| Lens Color | Lamp Voltage | Cat. No. |
| Green | 24V AC/DC | 800FD-P3N3 |
| 120V AC | 800FD-P3N5 | |
| Red | 24V AC/DC | 800FD-P4N3 |
| 120V AC | 800FD-P4N5 | |
| Yellow | 24V AC/DC | 800FD-P5N3 |
| 120V AC | 800FD-P5N5 | |
| Blue | 24V AC/DC | 800FD-P6N3 |
| 120V AC | 800FD-P6N5 | |
| Clear | 24V AC/DC | 800FD-P7N3 |
| 120V AC | 800FD-P7N5 | |
Bul. 800F Potentiometer Operators⋆
|
| Resistive Element (W) | Cat. No. |
| 150 | 800FP-POT1 |
| 500 | 800FP-POT2 |
| 1000 | 800FP-POT3 |
| 2500 | 800FP-POT4 |
| 5000 | 800FP-POT5 |
| 10 000 | 800FP-POT6 |
| ⋆ Only available in Position 1 for a 3-hole enclosure, Positions 1 and/or 5 for a 5-hole enclosure, Positions 1 and/or 7 for a 7-hole enclosure, and positions 1 and/or 9 for a 9-hole enclosure. No latches are required. | |
Bul. 800F Hole Plug
|
| Color | Cat. No. |
| Black plastic | 800F-N2 |
1-, 2-, and 3-Speed Contact Block Assemblies
|
|
|
| Cat. No. 800FC-ALP | Cat. No. 800F-ALP |
| Operator Type | Interlock Type | Composite Cat. No. | Separate Catalog Numbers | ||||
| Latch Cat. No. | Contact Block Location 1 Cat. No. | Contact Block Location 2 Cat. No. | Contact Block Location 3 Cat. No. | ||||
| 1-speed | No interlock | 800F-PX10E | 800F-ALP | — | — | 800F-X10E | |
| Electrical interlock | 800F-PX11C | 800F-ALP | 800F-X01B | ||||
| Mechanical interlock♣ | 800F-LX20C | 800FC-ALP | — | ||||
| Electrical & mechanical interlock♣ | 800F-LX22C | 800FC-ALP | 800F-X01B | ||||
| 2-speed | No interlock | 800F-PX20C | 800F-ALP | — | 800F-X10N (Speed 2) |
800F-X10E (Speed 1) |
|
| Electrical interlock | 800F-PX21C | 800F-ALP | 800F-X01B | ||||
| Mechanical interlock♣ | 800F-LX40C | 800FC-ALP | — | ||||
| Electrical & mechanical interlock♣ | 800F-LX42C | 800FC-ALP | 800F-X01B | ||||
| 3-speed | No interlock | | 800F-PX30C | 800F-ALP | 800F-X10N | 800F-X10E (Speed 2) |
800F-X10M (Speed 1)§ |
| Mechanical interlock♣ | | 800F-LX60C | 800FC-ALP | 800F-X10N (Speed 3) |
|||
| Contact blocks come preassembled onto latch. | |||||||
| § For proper operation, Cat. No. 800F-X10M must be mounted in position 3 of either the mechanical or standard latch. | |||||||
| ♣ When ordering separate components, two pieces of each contact block must be ordered, one for each operator. | |||||||
Accessories
Engraved Legend Plates
| Vertical | Horizontal | |
|
|
|
| Cat. No. 800F-36VE416 | Cat. No. 800F-36HE416 |
| Description | Cat. No. | Description | Cat. No. | |
| Blank | 800F-36BE100 | 1-2-3 SPEED, O/H CRANE, FORWARD | 800F-36♣ E411 | |
| O-I | 800F-36♣ U231 | 1-2-3 SPEED, O/H CRANE, REVERSE | 800F-36♣ E412 | |
| I-O-II | 800F-36♣ U234 | ALARM | 800F-36♣ E413 | |
| RESET | 800F-36♣ E186 | HOIST, LEFT | 800F-36♣ E414 | |
| START | 800F-36♣ E208 | HOIST, RIGHT | 800F-36♣ E415 | |
| STOP | 800F-36♣ E212 | LIFT, DOWN | 800F-36♣ E416 | |
| 1-2 SPEED, HOIST, LEFT | 800F-36♣ E401 | LIFT, DOWN FAST | 800F-36♣ E417 | |
| 1-2 SPEED, HOIST, RIGHT | 800F-36♣ E402 | LIFT, UP | 800F-36♣ E418 | |
| 1-2 SPEED, LIFT, DOWN | 800F-36♣ E403 | LIFT, UP FAST | 800F-36♣ E419 | |
| 1-2 SPEED, LIFT, UP | 800F-36♣ E404 | O/H CRANE, FORWARD | 800F-36♣ E420 | |
| 1-2 SPEED, O/H CRANE, FORWARD | 800F-36♣ E405 | O/H CRANE, FORWARD, FAST | 800F-36♣ E421 | |
| 1-2 SPEED, O/H CRANE, REVERSE | 800F-36♣ E406 | O/H CRANE, LEFT FAST | 800F-36♣ E422 | |
| 1-2-3 SPEED, HOIST, LEFT | 800F-36♣ E407 | O/H CRANE, REVERSE | 800F-36♣ E423 | |
| 1-2-3 SPEED, HOIST, RIGHT | 800F-36♣ E408 | O/H CRANE, REVERSE, FAST | 800F-36♣ E424 | |
| 1-2-3 SPEED, LIFT, DOWN | 800F-36♣ E409 | O/H CRANE, RIGHT FAST | 800F-36♣ E425 | |
| 1-2-3 SPEED, LIFT, UP | 800F-36♣ E410 | START, ALARM | 800F-36♣ E426 | |
| Custom text | | 800F-36♣ E100⋆ | ||
| ♣ For vertically mounted operators, add a V to the cat. no. Example: Cat. No. 800F-36§ E186 becomes Cat. No. 800F-36VE186. For horizontally mounted operators, add an H to the cat. no. Example: Cat. No. 800F-36§ E186 becomes Cat. No. 800F-36HE186. |
||||
| ⋆ Font code (K, S, L) must be selected from the following table. | ||||
| Please fill in the custom text fax sheet found on Custom Text Fax/Scan Sheet to ensure accuracy of legend plate engraving. | ||||
Specifications
Specifications⋆
Front-of-Panel (Operators)
| Mechanical Ratings | ||
| Description | Plastic (Bulletin 800FP) | |
| Vibration (assembled to panel) | Tested at 10…2000 Hz, 1.52 mm displacement (peak-to-peak) max./10 G max. for 3 hr duration, no damage | |
| Shock | Tested at 1/2 cycle sine wave for 11 ms; no damage at 100 G | |
| Degree of protection | IP66 (Type 4/4X/13) | |
| Mechanical durability per EN 60947‑5‑1 (Annex C) | 10 000 000 Cycles | Momentary push buttons |
| 1 000 000 Cycles | Multi-function, selector switch, key selector switch | |
| 300 000 Cycles | Twist-to-release E-stop, illuminated push-pull E-stop, alternate action push buttons | |
| 100 000 Cycles | Potentiometer, toggle switch | |
| Operating forces (typical with one contact block) | Flush/extended = 5 N, E-stop = 36 N | |
| Operating torque (typical application with one contact block) |
Selector switch = 0.25 Nm (2.2 lbin) | |
| Mounting torque | 1.7 Nm (15 lbin) | |
| Environmental | ||
| Temperature range (operating) | -25…+70 °C (-13…+158 °F)§ | |
| Temperature range (short term storage) | -40…+85 °C (-40…+185 °F) | |
| Humidity | 50…95% RH from 25…60 °C (77…140 °F) | |
| ⋆ Performance Data — see Performance Data. | ||
| Plastic keyed operators are IP66, Type 4/13; not Type 4X. | ||
| § Operating temperatures below 0 °C (32 °F) are based on the absence of freezing moisture and liquids, UL Recognized to 55 °C (131 °F) - Incandescent module max. 40 °C (104 °F) - fully populated 9-hole pendant enclosure 45 °C (113 °F) with 75 °C wire. | ||
| Note:Use UL Listed type S or SJ cords, with a smooth outer jacket rated for wet locations use (marked W) and oil resistant outer covering (marked O) such as SOW or SJOW with copper wire, rated 75 °C min., 18…12 AWG, with an overall OD of 7.5…15 mm for the small cable sleeve (Cat. No. 800FC-AS3) and 9…22.5 mm for the large cable sleeve (Cat. No. 800FC-AS5). | ||
Back-of-Panel Components⋆
| Electrical Ratings | ||||
| Standard contact block ratings | A600, Q600 600V AC AC 15, DC 13 to IEC/EN 60947-5-1 and UL 508, 17V, 5 mA min. |
|||
| Low voltage contact block ratings | 5V, 1 mA DC min. C300, R150, AC 15, DC 13 to EN 60947-5-1 and UL 508 |
|||
| Nominal Voltage | Range | Current Draw | Frequency | |
| LED Module Ratings | 24V AC 24V DC 120V AC 240V AC |
10…29V AC 10…30V DC 70…132V AC 180…264V AC |
31 mA 24 mA 25 mA 22 mA |
50/60 Hz DC 50/60 Hz 50/60 Hz |
| Thermal current | 10 A max. enclosed (40 °C ambient) to UL508, EN 60947-5-1 | |||
| Insulation voltage (Ui) | Screw terminal = 690V, spring-clamp = 300V | |||
| Wire capacity (screw terminal)§ | #18…12 AWG (0.75…2.5 mm2) Max. (2) #14 AWG or (1) #12 AWG |
|||
| Wire capacity (spring-clamp terminal) | #18…14 AWG (0.75…1.5 mm2) One per spring clamp, two spring clamps per terminal | |||
| Recommended tightening torque on screw terminals | 0.7…0.9 Nm (6…8 lbin) | |||
| Dielectric strength (minimum) | 2500V for one minute | |||
| External short circuit protection | Standard blocks | 10 A type gL/gG cartridge fuse to EN 60269-2-1 or gN (Class J to UL 248-8 or Class C to UL 248-4) |
||
| Low voltage contact blocks | 6 A type gL/gG cartridge fuse to EN 60269-2-1 or gN (Class J to UL 248-8 or Class C to UL 248-4) |
|||
| Electrical shock protection | Finger-safe conforming to IP2X | |||
| Mechanical Ratings | ||||
| Vibration (assembled to panel) | Tested at 10…2000 Hz, 1.52 mm displacement (peak-to-peak) max./10 G max. 6 hr | |||
| Shock | Tested at 1/2 cycle sine wave for 11 ms and no damage at 100 G max. | |||
| Contact durability per EN 60947-5-1 (Annex C) | 10 000 000 cycles | |||
| Contact operation | N.O. | Slow double make and break | ||
| N.C. | Slow double make and break — positive opening |
|||
|
|
||||
| N.O.E.M. | Double break / double make, early make | |||
| N.C.L.B. | Double break / double make, late break — positive opening |
|||
|
|
||||
| N.C.E.B. | Double break / double make, early break — positive opening |
|||
|
|
||||
| N.O.E.E.M. | Double break / double make, early early make | |||
| N.O.L.M. | Double break / double make, late make | |||
| Standard push button travel to change electrical state | N.C. and N.O.E.M. | 1.5 mm (0.060 in.) | ||
| N.O. and N.C.L.B. | 2.5 mm (0.1 in.) | |||
| Multi-speed push button travel to change electrical state | N.O.E.E.M. | 3 mm (0.12 in.) | ||
| N.C.E.B. | 4 mm (0.16 in.) | |||
| N.O.L.M. | 7 mm (0.28 in.) | |||
| Operating forces (typical) | Single-circuit contact block | 3.4 N | ||
| Dual-circuit contact block | 5…6.5 N | |||
| Illumination | ||||
| LED Dominant Wavelength | Green Red Yellow Blue White |
525 nm 629 nm 590 nm 470 nm — |
||
| LED Luminous Intensity | Green Red Yellow Blue White |
780 mcd 780 mcd 600 mcd 168 mcd 360 mcd |
||
| Materials | ||||
| Springs | Stainless steel and zinc coated music wire | |||
| Electrical contacts | Standard | Silver-nickel | ||
| Low voltage | Gold-plated over silver | |||
| Terminals | Screw | Brass | ||
| Spring-clamp | Silver-plated brass | |||
| ⋆ Performance Data — see Performance Data. | ||||
| Low voltage contacts are recommended for applications below 17V, 5 mA. | ||||
| § Wires less than #18 AWG (0.75 mm2) may not hold in terminal securely. | ||||
Material Listing
| Component | For Use with | Material Used |
| Panel gasket | All operators | Nitrile, TPE |
| Diaphragm seal | Illuminated push button, non-illuminated push button | Automotive industry acceptable silicone |
| K-seal | Selector switch, key selector switch, push/twist-to-release E-stop, key E-stop | Nitrile |
| Diaphragm retainer, return spring I | Illuminated push button, non-illuminated push button | Stainless steel |
| Return spring II | Selector switch, key selector switch, alternate action, push/twist-to-release E-stop, key E-stop |
Zinc-coated music wire |
| Button cap | Non-illuminated push button, push/twist-to-release, E-stop, key E-stop, multi-function | PBT/polycarbonate blend |
| 2-color molded button cap | Non-illuminated push button | PBT/polycarbonate blend |
| Lens | Multi-function | Acetal |
| Lens, knob | Illuminated push button | Polyamide |
| Knob | Non-illuminated selector switch | Glass-filled polyamide |
| Plastic bezel/bushing I | Non-illuminated push button, illuminated push button, selector switch, key selector switch, push/twist-to-release E-stop, key E-stop, multi-function | Glass-filled polyamide |
| Plastic bezel/bushing II | Pilot light | Glass-filled PBT |
| Diffuser | Illuminated push button, pilot light | Polycarbonate |
| Plastic mounting ring | All plastic operators | Glass-filled polyamide |
| Plastic latch | — | Glass-filled polyamide |
| Mechanical interlock latch | — | Glass-filled polyamide |
| Plastic enclosure | — | PBT/polycarbonate blend |
| Terminal screws | LED module, contact blocks | Zinc-plated steel with chromate |
| Terminals | LED module, contact blocks | Brass with silver-nickel contacts |
| Housing | LED module | Glass-filled polyamide |
| Low-voltage terminals | Contact blocks | Gold-plated silver-nickel contacts |
| Low-voltage spanner | Contact blocks | Gold-plated silver-nickel contacts |
| Spanner | Contact blocks | Brass with silver-nickel contacts |
| Boot | Illuminated push button, non-illuminated push button, multi-function illuminated and non-illuminated | Automotive industry acceptable silicone |
Approximate Dimensions ⋆
Bul. 800FC 1-, 2-, and 3-Speed Operator
|
Bul. 800FC Legend Plate
|
Bul. 800FC Pendant Station (3-Hole)
|
Bul. 800FC Pendant Station (5-, 7-, and 9-Hole)
| Cat. No. | No. of Holes | A | B |
| 800FC-4/5/C/D | 5 | 309 | 36 |
| 800FC-6/7/E/F | 7 | 381 | 36 |
| 800FC-8/9/G/H | 9 | 453 | 36 |
|
⋆ For Bul. 800F operator dimensions, see Approximate Dimensions.
Custom Text Fax/Scan Sheet
|