| Cat. No. 800FC-3Z
|
Cat. No. 800FC-7Z
|
| Enclosure Type
|
Pkg. Quantity
|
Pendants — Yellow Plastic IP66 Cat. No.⋆
|
| 3-hole
|
1
|
800FC-3Z
|
| 5-hole
|
800FC-5Z
|
| 7-hole
|
800FC-7Z
|
| 9-hole
|
800FC-9Z
|
|
|
| ⋆ Housings supplied with cable sleeve, hanger ring, cable clamp, wire guides, and gasket.
|
1-, 2-, and 3-Speed Operators ♣ ∆
| a
|
| Operator Type
|
| Code
|
Description
|
| A
|
1-speed single arrow
|
| D
|
1-speed double arrow
|
| B
|
2-speed
|
| C
|
3-speed
|
Proper contact block assembly of these devices is required. Please see contact block information on page1-, 2-, and 3-Speed Contact Block Assemblies.
| b
|
| Cap Color
|
| Code
|
Description
|
| 1
|
White
|
| 2
|
Black
|
| c
|
|
|
Symbol
|
| Code
|
Valid with Table a Selections:
|
Description§
|
| Vertical Mounting
|
Horizontal Mounting
|
| Black with White Arrow
|
White with Black Arrow
|
White with Black Arrow
|
Black with White Arrow
|
| U100
|
A, B, C
|
Blank
|
Blank
|
Blank
|
Blank
|
|
|
One-Speed Operators
|
| U241
|
A
|
DOWN
|
UP
|
—
|
—
|
| U243
|
—
|
—
|
RIGHT
|
LEFT
|
| U244
|
REVERSE
|
FORWARD
|
—
|
—
|
| U246
|
—
|
—
|
FORWARD
|
REVERSE
|
| U700
|
LEFT
|
RIGHT
|
UP
|
DOWN
|
|
U261
|
D
|
DOWN FAST
|
UP FAST
|
—
|
—
|
| U263
|
—
|
—
|
RIGHT FAST
|
LEFT FAST
|
| U264
|
REVERSE FAST
|
FORWARD FAST
|
—
|
—
|
| U266
|
—
|
—
|
FORWARD FAST
|
REVERSE FAST
|
| U260
|
LEFT FAST
|
RIGHT FAST
|
UP FAST
|
DOWN FAST
|
|
|
Two-Speed Operators
|
| U271
|
B
|
2-speed DOWN
|
2-speed UP
|
—
|
—
|
| U273
|
—
|
—
|
2-speed RIGHT
|
2-speed LEFT
|
| U274
|
2-speed REVERSE
|
2-speed FORWARD
|
—
|
—
|
| U276
|
—
|
—
|
2-speed FORWARD
|
2-speed REVERSE
|
| U270
|
2-speed LEFT
|
2-speed RIGHT
|
2-speed UP
|
2-speed DOWN
|
|
|
Three-Speed Operators
|
| U291
|
C
|
3-speed DOWN
|
3-speed UP
|
—
|
—
|
| U293
|
—
|
—
|
3-speed RIGHT
|
3-speed LEFT
|
| U294
|
3-speed REVERSE
|
3-speed FORWARD
|
|
|
| U296
|
|
|
3-speed FORWARD
|
3-speed REVERSE
|
| U290
|
3-speed LEFT
|
3-speed RIGHT
|
3-speed UP
|
3-speed DOWN
|
Note:Please see page1-, 2-, and 3-Speed Contact Block Assemblies for proper latch and contact block configurations.
§ Text (DOWN, UP, LEFT, etc.) indicates arrow direction. Text is not printed on operators.
♣ Cat. No. 800F-ALP (standard latch) and Cat. No. 800FC-ALP (mechanical interlock latch) can be used with these operators.
∆ Booted style of operators for pendant stations.
Arrow Direction Chart
Bul. 800F Two-Position Twist-to-Release and Twist-to-Release/Push-Pull Operators
| Description
|
Operator Cat. No.
|
Guard Cat. No.
|
| Twist-to-release — Red
|
800FP-MT44PX01
|
—
|
| Twist-to-release — Red, illuminated
|
800FP-LMT44PN♣ RX01
|
—
|
| Keyed twist-to-release — Red
|
800FP-MK44PX01
|
—
|
| Twist-to-release or push-pull — Red, monolithic
|
800FD-MT44X01
|
—
|
| Twist-to-release or push-pull — Red, monolithic with guard, monolithic
|
800FD-MT44X01
|
800F-AMEGY
|
|
|
| ♣ Select 3 for 24V AC/DC or 5 for 120V AC.
|
Bul. 800F Push Button Operators and Caps — Extended & Non-Illuminated ⋆
| Cap Color
|
Description
|
Symbol Definition
|
Operator Cat. No.
|
Cap Cat. No.
|
Complete Operator Cat. No.
|
Composite Cat. No./ No Electrical Interlock
|
Composite Cat. No./ Electrical Interlock
|
| Black
|
Blank
|
—
|
800FP-E2
|
—
|
—
|
800FP-E2PX10
|
800FP-E2PX11
|
| LEFT or DOWN
|
Single arrow 0°
|
800FP-E9
|
800F-AE208
|
800FP-E208
|
800FP-E208PX10
|
800FP-E208PX11
|
| REVERSE
|
Single arrow 45°
|
800F-AE2CU244
|
800FP-E2U244
|
800FP-E2U244PX10
|
800FP-E2U244PX11
|
| LEFT FAST or DOWN FAST
|
Double arrow 0°
|
800F-AE2CU261
|
800FP-E2U261
|
800FP-E2U261PX10
|
800FP-E2U261PX11
|
| REVERSE FAST
|
Double arrow 45°
|
800F-AE2CU264
|
800FP-E2U264
|
800FP-E2U264PX10
|
800FP-E2U264PX11
|
| White
|
Blank
|
—
|
800FP-E1
|
—
|
—
|
800FP-E1PX10
|
800FP-E1PX11
|
| UP or RIGHT
|
Single arrow 0°
|
800FP-E9
|
800F-AE108
|
800FP-E108
|
800FP-E108PX10
|
800FP-E108PX11
|
| FORWARD
|
Single arrow 45°
|
800F-AE1CU244
|
800FP-E1U244
|
800FP-E1U244PX10
|
800FP-E1U244PX11
|
| UP FAST or RIGHT FAST
|
Double arrow 0°
|
800F-AE1CU261
|
800FP-E1U261
|
800FP-E1U261PX10
|
800FP-E1U261PX11
|
| FORWARD FAST
|
Double arrow 45°
|
800F-AE1CU264
|
800FP-E1U264
|
800FP-E1U264PX10
|
800FP-E1U264PX11
|
| Green
|
Blank
|
—
|
800FP-E3
|
—
|
—
|
800FP-E3PX10
|
—
|
| START/ALARM
|
Start/Alarm
|
800FP-E9
|
800F-AE3CU222
|
800FP-E3U222
|
800FP-E3U222PX10
|
| START
|
Start symbol
|
800F-AE3CU909
|
800FP-E3U909
|
800FP-E3U909PX10
|
| Red
|
Blank
|
—
|
800FP-E4
|
—
|
—
|
800FP-E4PX10
|
| STOP
|
Stop symbol
|
800FP-E9
|
800F-AE405
|
800FP-E405
|
800FP-E405PX10
|
| Yellow
|
Blank
|
—
|
800FP-E5
|
—
|
—
|
800FP-E5PX10
|
| ALARM
|
Alarm
|
800FP-E9
|
800F-AE5CU223
|
800FP-E5U223
|
800FP-E5U223PX10
|
| Blue
|
Blank
|
—
|
800FP-E6
|
—
|
—
|
800FP-E6PX10
|
| R
|
Reset symbol
|
800FP-E9
|
800F-AE611
|
800FP-E611
|
800FP-E611PX10
|
|
|
| For 24V AC/DC units, add V for low voltage contact blocks. Example: Cat. No. 800FP-E5PX10 becomes Cat. No. 800FP-E5PX10V.
|
| ⋆ Mechanical interlock is not allowed.
|
Bul. 800F Push Button Operators — Extended & Illuminated ⋆
| Lens Color
|
Operator Cat. No.
|
Composite Cat. No.
|
| Green
|
800FP-LE3
|
800FP-LE3PN♣ GX10
|
| Red
|
800FP-LE4
|
800FP-LE4PN♣ RX10
|
| Yellow
|
800FP-LE5
|
800FP-LE5PN♣ WX10
|
| Blue
|
800FP-LE6
|
800FP-LE6PN♣ BX10
|
| Clear
|
800FP-LE7
|
800FP-LE7PN♣ WX10
|
|
|
| ♣ Select 3 for 24V AC/DC or 5 for 120V AC.
|
| ⋆ Mechanical interlock is not allowed.
|
Bul. 800F Selector Switch Operators — Maintained & Non-Illuminated
| Number of Positions
|
Keyed
|
Operator Cat. No.
|
Composite Cat. No.
|
| 2
|
No
|
800FP-SM22
|
800FP-SM22PX11
|
| Yes
|
800FP-KM21
|
800FP-KM21PX11
|
| 3
|
No
|
800FP-SM32
|
800FP-SM32PX20
|
| Yes
|
800FP-KM34
|
800FP-KM34PX20
|
|
|
| For 24V AC/DC units, add V for low voltage contact blocks. Example: Cat. No. 800FP-E5PX10 becomes Cat. No. 800FP-E5PX10V.
|
Bul. 800F Multi Operators and Caps— Extended § ⋆
|
|
|
|
|
|
|
| Vertical Mounting
|
Horizontal Mounting
|
| Description
|
Symbol Definition
|
Illumination
|
Operator Cat. No.
|
Position A Cap Cat. No.
|
Position C Cap Cat. No.
|
Back of Panel Cat. No.
|
| Blank (black and white cap)
|
—
|
Non-Illuminated
|
800FP-U2X
|
800F-AEU2
|
800F-AEU1
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| Vertical Mounting
|
| UP (white)/DOWN (black)
|
Single arrow 0°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU2CU241
|
800F-AECU1CU241
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| RIGHT (white)/LEFT (black)
|
Single arrow 90°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU2CU700
|
800F-AECU1CU700
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| FORWARD (white)/REVERSE (black)
|
Single arrow 45°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU2CU244
|
800F-AECU1CU244
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| UP FAST (white)/DOWN FAST (black)
|
Double arrow 0°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU2CU261
|
800F-AECU1CU261
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| RIGHT FAST (white)/LEFT FAST (black)
|
Double arrow 90°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU2CU260
|
800F-AECU1CU260
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| FORWARD FAST (white)/REVERSE FAST (black)
|
Double arrow 45°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU2CU264
|
800F-AECU1CU264
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| Horizontal Mounting
|
| LEFT (black)/RIGHT (white)
|
Single arrow 90°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU1CU241
|
800F-AECU2CU241
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| DOWN (black)/UP (white)
|
Single arrow 0°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU1CU242
|
800F-AECU2CU242
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| REVERSE (black)/FORWARD (white)
|
Single arrow 45°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU1CU245
|
800F-AECU2CU245
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| LEFT FAST (black)/UP FAST (white)
|
Double arrow 90°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU1CU261
|
800F-AECU2CU261
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| DOWN FAST (black)/UP FAST (white)
|
Double arrow 0°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU1CU262
|
800F-AECU2CU262
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
| REVERSE FAST (black)/FORWARD FAST (white)
|
Double arrow 45°
|
Non-Illuminated
|
800FP-U2X
|
800F-AECU1CU265
|
800F-AECU2CU265
|
800F-PX20
|
| Illuminated
|
800FP-LU2X
|
800F-PN♣ WX20
|
|
|
| ♣ Select 3 for 24V AC/DC or 5 for 120V AC.
|
| For 24V AC/DC units, add V for low voltage contact blocks. Example: Cat. No. 800F-PX20 becomes Cat. No. 800F-PX20V
|
| § Electrical interlock cannot be performed within the pendant enclosure.
|
| ⋆ Mechanical interlock is not allowed.
|
Bul. 800F Pilot Lights — Monolithic
| Lens Color
|
Lamp Voltage
|
Cat. No.
|
| Green
|
24V AC/DC
|
800FD-P3N3
|
| 120V AC
|
800FD-P3N5
|
| Red
|
24V AC/DC
|
800FD-P4N3
|
| 120V AC
|
800FD-P4N5
|
| Yellow
|
24V AC/DC
|
800FD-P5N3
|
| 120V AC
|
800FD-P5N5
|
| Blue
|
24V AC/DC
|
800FD-P6N3
|
| 120V AC
|
800FD-P6N5
|
| Clear
|
24V AC/DC
|
800FD-P7N3
|
| 120V AC
|
800FD-P7N5
|
|
|
Bul. 800F Potentiometer Operators⋆
| Resistive Element (W)
|
Cat. No.
|
| 150
|
800FP-POT1
|
| 500
|
800FP-POT2
|
| 1000
|
800FP-POT3
|
| 2500
|
800FP-POT4
|
| 5000
|
800FP-POT5
|
| 10 000
|
800FP-POT6
|
|
|
| ⋆ Only available in Position 1 for a 3-hole enclosure, Positions 1 and/or 5 for a 5-hole enclosure, Positions 1 and/or 7 for a 7-hole enclosure, and positions 1 and/or 9 for a 9-hole enclosure. No latches are required.
|
Bul. 800F Hole Plug
| Color
|
Cat. No.
|
| Black plastic
|
800F-N2
|
|
|
1-, 2-, and 3-Speed Contact Block Assemblies
|
|
|
| Cat. No. 800FC-ALP
|
Cat. No. 800F-ALP
|
| Operator Type
|
Interlock Type
|
Composite Cat. No.
|
Separate Catalog Numbers
|
| Latch Cat. No.
|
Contact Block Location 1 Cat. No.
|
Contact Block Location 2 Cat. No.
|
Contact Block Location 3 Cat. No.
|
| 1-speed
|
No interlock
|
800F-PX10E
|
800F-ALP
|
—
|
—
|
800F-X10E
|
| Electrical interlock
|
800F-PX11C
|
800F-ALP
|
800F-X01B
|
| Mechanical interlock♣
|
800F-LX20C
|
800FC-ALP
|
—
|
| Electrical & mechanical interlock♣
|
800F-LX22C
|
800FC-ALP
|
800F-X01B
|
| 2-speed
|
No interlock
|
800F-PX20C
|
800F-ALP
|
—
|
800F-X10N (Speed 2)
|
800F-X10E (Speed 1)
|
| Electrical interlock
|
800F-PX21C
|
800F-ALP
|
800F-X01B
|
| Mechanical interlock♣
|
800F-LX40C
|
800FC-ALP
|
—
|
| Electrical & mechanical interlock♣
|
800F-LX42C
|
800FC-ALP
|
800F-X01B
|
| 3-speed
|
No interlock
|
|
800F-PX30C
|
800F-ALP
|
800F-X10N
|
800F-X10E (Speed 2)
|
800F-X10M (Speed 1)§
|
| Mechanical interlock♣
|
|
800F-LX60C
|
800FC-ALP
|
800F-X10N (Speed 3)
|
|
|
| Contact blocks come preassembled onto latch.
|
| § For proper operation, Cat. No. 800F-X10M must be mounted in position 3 of either the mechanical or standard latch.
|
| ♣ When ordering separate components, two pieces of each contact block must be ordered, one for each operator.
|