Catalogs > Industrial Controls Catalog > Signaling > Beacons > Bulletins 855BS/855BM/855BL Round Beacons
Bulletins 855BS/855BM/855BL Round Beacons
| Introduction | Standards Compliance and Certifications | Product Selection | Accessories | Specifications | Approximate Dimensions |
Lamps
| 855B | M | | LH | 10 | ||
| a | b | c |
| a | b | c | |||||
| Size | Function | Voltage | |||||
| Code | Description | Code | Description | Code | Description | ||
| S | 90 mm | LH | Halogen | 12 | 12V AC/DC | ||
| M | 120 mm | 24 | 24V AC/DC | ||||
| L | 160 mm | 10 | 120V AC | ||||
| 20 | 240V AC | ||||||
Lenses
| 855B | L | | AFL | 4 | ||
| a | b | c |
| a | b | c | |||||
| Size | Function | Lens Color | |||||
| Code | Description | Code | Description | Code | Description | ||
| S | 90 mm | ASL | Replacement smooth lens§ | 3 | Green | ||
| M | 120 mm | AFL | Replacement Fresnel lens | 4 | Red | ||
| L | 160 mm | ALL | Replacement LED lens♣ | 5 | Amber | ||
| 6 | Blue | ||||||
| 7 | Clear | ||||||
| 8 | Yellow | ||||||
§ Smooth lens for rotating function only.
∆ Fresnel lens not for use with LED beacons.
♣ LED lens for 90 mm only.
Power Module Assemblies
| 855B | L | | ARA | 10 | ||
| a | b | c |
| a | b | c | |||||
| Size | Function | Voltage | |||||
| Code | Description | Code | Description | Code | Description | ||
| S | 90 mm | ARA | Replacement rotating power module | 12 | 12V AC/DC | ||
| M | 120 mm | ADA | Replacement steady power module | 24 | 24V AC/DC | ||
| L | 160 mm | AFA | Replacement flashing power module | 10 | 120V AC | ||
| ABA | Replacement strobe power module | 20 | 240V AC | ||||
Miscellaneous Accessories and Replacement Parts
| 855B | M | | LS | |
| a | b |
| a | b | |||
| Size | Function | |||
| Code | Description | Code | Description | |
| S | 90 mm | ALSG | Lens gaskets (bag of 5) | |
| M | 120 mm | AMM | Magnetic mount | |
| L | 160 mm | ASFG | Surface mount gaskets (bag of 5) | |
| AMTG | Metric tube gaskets (bag of 5) | |||
| AWP | Rough wall plate⋆ | |||
| AVM | Vertical bracket | |||
| LS | Strobe tube (120 mm or 160 mm only) | |||
| ABS | Surface mount base | |||
| ABN | NPT conduit mount base | |||
| ABT | Tube mount base | |||
⋆ Required for UL Type 4/4X/13 rating when using surface mount base outdoors.
When used outdoors surface mount base must be installed with rough wall plate for UL Type 4/4X/13 rating, otherwise UL Type 1 only.