Bulletin 600 Single Phase

Click to enlarge - 600-1_150-1


Bulletin 600

Starting and overload protection of small 1-phase AC/DC motors used on the following:


Bulletin 600 manual switches consist of a snap switch combined with a thermal overload device operating on the solder-ratchet principle. The switch is designed to prevent being held closed under a sustained motor overload. To reset the overload mechanism, the switch lever is moved to the OFF position. The motor can be restarted by pushing the switch lever to the ON position. Applications include compressors, fans and pumps.

Table of Contents
Accessories
Modifications
Approximate Dimensions

Standards Compliance and Certifications

Standards Compliance


Certifications



Product Seletion

Your order must include: 1) Cat. no. of the switch, 2) Cat. no. of the heater element(s), and 3) if required, cat. no. of any accessories.

Ratings

Single Pole — 1 HP 115…230V AC, 1 HP 277V AC, Open Type without Enclosure or Type 1 General Purpose Enclosure
Two Pole — 1 HP 115…230V AC, 1 HP 277V AC, Open Type without Enclosure or Type 1 General Purpose Enclosure, 3/4 HP 115…230V DC


Selector Switch — 1 HP 115…230V AC, 1 HP 277V AC, Open Type without Enclosure or Type 1 General Purpose Enclosure
Heater Element — See Eutectic Alloy Overload Relay Heater Elements for heater element selection table.


Description Open Type
Without Enclosure
Includes Legend Plate
Type 1
General Purpose
Enclosure
Surface Mounting
Type 1
General Purpose
Enclosure
Flush Mounting
Includes Flush Plate but not Switch Box
Type 4
Watertight Enclosure
Type 7 & 9 Enclosure
Class I, Groups C & D
Class II,
Groups E, F & G

– Divisions 1 & 2 –
Hazardous Locations
Stainless Steel
Flush Plate
    Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
Switch Only
Toggle Type 1-Pole 600-TOX4 600-TAX4 600-TQX4
  2-Pole 600-TOX5 600-TAX5 600-TQX5 600-TCX5 600-TEX5
Key Type 2-Pole 600-TOX49 600-TAX49 600-TQX49
Lever Type 1-Pole 600-TOX149 600-TAX149
Switch with Neon Pilot Light (115 or 230V)
Toggle Type 1-Pole 600-TOX216 600-TAX216 600-TQX216
  2-Pole 600-TOX109 600-TAX109 600-TQX109
Key Type 2-Pole 600-TOX110 600-TAX110 600-TQX110
Switch with Incandescent Pilot Light
Toggle Type 2-Pole 115V 600-TCD7 600-TED7
  2-Pole 230V 600-TCA7 600-TEA7
Switch and “Hand-Off-Auto” Selector Switch (for use on AC only)
Toggle Type 2-Pole 600-TAX9 600-TQX9 600-TCX9 600-TEX9
Switch with Neon Pilot Light and “Hand-Off-Auto” Selector Switch (115 or 230V, AC only)
Toggle Type 2-Pole 600-TAX142 600-TQX142
Key Type 2-Pole 600-TAX145
Two Switch Units in One Enclosure
Toggle Type 2-Pole 600-TAX10 600-TCX10 600-TEX10
Two Switch Units in One Enclosure Neon Pilot Light on Both Units (115 or 230V)
Toggle Type 2-Pole 600-TAX144 600-TQX144
Two Speed Switch
Toggle Type 2-Pole 600-TAX298
Two Speed Switch with Neon Pilot Lights (115 or 230V)
Toggle Type 2-Pole 600-TAX293 600-TQX293
Separate Cover and Switch Assembly¬ 
Toggle Type 2-Pole 600-N12
Hand-Off-Auto 600-N14
  
¬ For use with Bulletin 800H, Type 7 and 9, Series C or later bases.

Accessories

Description NEMA
Enclosure Type
Cat. No.
Pilot Light Replacement Bulb Incandescent¬  (Mfg. Designation #120 PSB-120V)
Note: Pilot lights as used on Bulletin
600 switches indicate whether the
motor is running only if the switch is
used to control the motor directly. If a
thermostat, pressure switch, or some
other pilot device controls the operation of the motor, the pilot light on the Bulletin 600 switch merely indicates whether the power is ON or OFF.
4, 7, and 9 800S-N60
Click to enlarge - 600-1_151-1
Locking Attachment
(For Toggle Operated Only)
1
(Switches in the
Type 4 and Type
7 and 9
enclosures are
supplied as
standard with
provisions for
locking in the
OFF or ON
position.)
600-N1
Click to enlarge - 600-1_151-2
Drain
(For 3/4 in. (19 mm) Conduit Opening)
7 and 9 800H-NP21
Click to enlarge - 600-1_151-3
Flange Seal
(Provides NEMA Type 3 rating for outdoor locations in addition to maintaining NEMA Type 7 and 9 integrity)
Note: An approved drain
Cat. No. 800H-NP21 is required for
condensation when this option is used
(refer to local Electrical Code).
3, 7, and 9 800H-NP20
Click to enlarge - 600-1_151-4
Sealing Well
(See applicable codes and laws)
(Not available for use with
Cat. No. 600-TEX5)
Note: When using a sealing well with
integral flange seal for NEMA Type 3
outdoor applications, an approved drain fitting must be provided (refer to local Electrical Code).
3, 7, and 9
(With integral
flange seal)
2 wire:
800H-NPRD90
4 wire:
800H-NPRD91
Click to enlarge - 600-1_151-5 7 and 9
(Without integral
flange seal)
2 wire:
800H-NPD90
4 wire:
800H-NPD91
  
¬ All other devices with the pilot light option utilize a neon lamp. For replacement information consult your local Rockwell Automation sales office or Allen-Bradley distributor. (For Type 1 enclosure use replacement bulb 40268-313-51)

Modifications

Modifications — Factory-Installed

Flange Seal (see applicable codes and laws) — This option provides a Type 3 rating in addition to maintaining a Type 7 & 9 integrity. Add the letter S to the end of the cat. no. Example: Cat. No. 600-TEX9S.

Conduit Openings (Type 4 and Type 7 & 9 only) — If two 3/4 in. (19 mm) pipe taps (one on top and one on bottom) are required, add the number 12 to the end of the cat. no. Example: Cat. No. 600-TEX512. Note: Suffix 12 is only an option for the Type 4 and 7 & 9 enclosures.

Note: All single unit devices are provided with one 3/4 in. (19 mm) pipe tap on the bottom. By reversing the switch base, the pipe tap can be located on the top.

All dual units are provided as standard with one 3/4 in. (19 mm) pipe tap on top and two on the bottom with two threaded plugs included. If 1/2 in. (12.7 mm) openings are required, reducers should be used.

Drain — In order to install a drain on single unit devices (i.e. Cat. No. 600-TEX5) an additional conduit opening is required. See “Conduit Openings” above.

Sealing Well with Integral Flange Seal for Type 3, 7, and 9 — To order this option insert the letter R at the end of the listed cat. no. Example: Cat. No. 600-TEX5R.

Sealing Well without Integral Flange Seal for Type 7 and 9 — To order this option insert the letter K at the end of the listed cat. no. Example: Cat. No. 600-TEX5K.


Approximate Dimensions

Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Open Type without Enclosure

Click to enlarge - 600-1_152-1


Cat. Nos.
600-  TOX4
TOX5
TOX49
600-  TOX109
TOX110
TOX149
600- TOX216


Type 1 General Purpose Enclosure Surface Mounting

Click to enlarge - 600-1_152-2


Cat. Nos.
600-  TAX4
TAX5
TAX49
600-  TAX109
TAX110
TAX149
600- TAX216


Cat. Nos.
600-  TAX9
TAX10
600-  TAX142
TAX144
600- TAX145

Dimension A in inches (Millimeters)
Key Inserted 1-1/8 (79.5)
Selector Switch 2-3/4 (70)
Toggle Operator 2-9/16 (65)
  

Type 4 Watertight Enclosure;
Type 7 and 9 Hazardous Locations Enclosure


Click to enlarge - 600-1_152-3


Cat. Nos.
600- TCX5 600- TEX5

Type 1 General Purpose Enclosure Flush Mounting

Click to enlarge - 1-178-1


Click to enlarge - 600-1_152-4


Cat. Nos.
600-  TQX4
TQX5
TQX49
600-  TQX109
TQX110
TQX216

Cat. Nos.
600-  TQX9
TQX142
600- TQX144

Click to enlarge - 1-178-2


Type 4 Watertight Enclosure, Type 7 & 9

Click to enlarge - 600-1_152-5


Cat. Nos.
600-  TCX9
TCX142
600-  TEX9
TEX10

Type 7 & 9 Hazardous Locations Enclosure

Click to enlarge - 600-1_152-6


Cat. Nos.
600-  TCA7
TCD75
600-  TEA7
TED7

¬ Lever Type Dimension is 2-17/32 in. (64.5 mm).
T This dimension may vary up to ±1/8 in. (3.2 mm). Mounting holes should be located at time of installation using device as a template.