Manual Motor Starters

Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Manual Motor Starters > Bulletin 609 Single and Three Phase

Bulletin 609 Single and Three Phase

Introduction Standards Compliance and Certifications Product Selection Accessories Approximate Dimensions
Your order must include: 1) Cat. no. of the switch, 2) Cat. no. of the heater element(s), and 3) if required, cat. no. of any accessories.

Build a Catalog Number


Product Selection

Single- and Three-Phase NEMA Manual Starting Switches

Type
of
Oper-
ator
Phase Size Maximum Horsepower Rating Open Type
without
Enclosure
Type 1
General
Purpose
Enclosure
Surface
Mounting
★ 
Type 12
Dusttight
Industrial
Use
Enclosure
Type 4/4X
Watertight,
Corrosion-
Resistant
Enclosure
Fiberglass-
Reinforced
Polyester
§ 
Hazardous Locations
Motor Voltage Enclosure Class I, Groups C & D
Class II, Groups E, F & G – Divisions 1 & 2
AC,
60 Hz
AC,
50 Hz
DC Type 7 & 9 Type 3R, 7 & 9♣ 
115V 200V 230V 460…
575V
380…
415V
115…
125V
230…
250V
Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
Push Button 1 Æ 0 1 2 609-AOX 609-AAX 609-AJX 609-ACX 609-AEX 609-AHX
1 2 3 609-BOX 609-BAX 609-BJX 609-BCX 609-BEX 609-BHX
1 P 3 5 609-XOX 609-XAX 609-XJX 609-XCX 609-XEX 609-XHX
3 Æ 0 3 3 5 5 609-AOW 609-AAW 609-AJW 609-ACW 609-AEW 609-AHW
1 7-1/2 7-1/2 10 10 609-BOW 609-BAW 609-BJW 609-BCW 609-BEW 609-BHW
Toggle Lever 1 Æ 0 1 2 609T-AOX 609T-AAX
1 2 3 609T-BOX 609T-BAX
1 P 3 5 609T-XOX 609T-XAX
3 Æ 0 3 3 5 5 609T-AOW 609T-AAW
1 7-1/2 7-1/2 10 10 609T-BOW 609T-BAW
Push Button DC‡  0 1 1-1/2 609D-AOZ 609D-AAZ 609D-ACZ 609D-AEZ 609D-AHZ
1 1-1/2 2 609D-BOZ 609D-BAZ 609D-BCZ 609D-BEZ 609D-BHZ
Toggle Lever DC‡  0 1 1-1/2 609DT-AOZ 609DT-AAZ
1 1-1/2 2 609DT-BOZ 609DT-BAZ
Bulletin 609RS — Manual Reversing Switches
Push Button 3 Æ 0 3 3 5 5 609-AOW21 609-AAW21
1 7-1/2 7-1/2 10 10 609-BOW21 609-BAW21
Toggle Lever 3 Æ 0 3 3 5 5 609T-AOW21 609T-AAW21
1 7-1/2 7-1/2 10 10 609T-BOW21 609T-BAW21
Bulletin 609TS — Manual 2-Speed Switches
Push Button 3 Æ 0 3 3 5 5 609-AOW22 609-AAW22
1 7-1/2 7-1/2 10 10 609-BOW22 609-BAW22
Toggle Lever 3 Æ 0 3 3 5 5 609T-AOW22 609T-AAW22
1 7-1/2 7-1/2 10 10 609T-BOW22 609T-BAW22
  
★ Type 1 general purpose flush mounting enclosures with pull box are also available. Order as follows. Change the second letter of the listed cat. no. from A to L. Example: Cat. No. 609-ALX. For a stainless steel flush plate, change the second letter of the listed cat. no. from A to Q. Example: Cat. No. 609-AQX.
‡ DC manual starters are not UL listed.
§ Fiberglass-reinforced polyester hubs are included with each starter.
♣ These enclosures include a cover gasket and drain. It is recommended that a breather also be installed.

Breather Cat. No. 1401-N1 (Can be installed at the top of an enclosure.)
Drain Cat. No. 1401-N2 (Can be installed at the bottom of an enclosure.)
Breather-Drain Combination Cat. No. 1401-N3 (Can be installed at the top of an enclosure as a breather or bottom as a drain.)