Bulletin 609U with Under Voltage Protection
| Product Overview |
|
Bulletin 609U
- Contact position indicator
- Locking features
- Wide range of enclosures:
Open-type, Type 1, and Type 12
- Undervoltage protection
Bulletins 609U and 609TU are the same as the standard Bulletin 609 Manual Starters except for the addition of undervoltage protection. These starters provide full line voltage starting, thermal overload protection, as well as undervoltage protection. Typical applications are on woodworking machinery, metal sawing machines, and many other machine tools where undervoltage protection is needed to meet safety standards. The undervoltage protection is accomplished by an electromechanical solenoid which is energized whenever line voltage is present. The solenoid is designed to mechanically open the starter contacts upon power failure, and keep them open even if power is returned to the unit. Only after the starter has been manually reset by pushing the operator to the stop position, can the starter be re-energized.
Open Type Bulletin 609U and 609TU switches can replace the Bulletin 609 switches in Types 1 and 12 enclosures of the latest construction without any field modification of the enclosure.
Standards Compliance and Certifications
Standards Compliance
- NEMA/EEMAC ICS2
(Industrial Controls and Systems)
- UL 508
- EN60947-4-1
- ABS 4/5.115
- USCG 46
- CFR 111.70
Certifications
- UL Listed (File No. E14841; Guide No. NLRV)
- CSA Certified (File LR 1234)
- American Bureau of Shipping (ABS)
- CE Marked
- Hazardous Location:
UL Listed (File No. E10314)
CSA Certified (File LR 11924)
Your order must include: 1) Cat. No. of the manual starting switch with undervoltage protection, 2) Cat. No. of the heater element(s), and 2) if required, Cat. No. of any accessories.
| Build a Catalog Number |
Product Selection
With Undervoltage Protection
| Type Of Operator | Phase | Size | Maximum Horsepower Rating | Open Type without Enclosure |
Type 1 General Purpose Enclosure Surface Mounting★ |
Type 12 Dusttight, Industrial Use Enclosure |
Type 4/4X Watertight, Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester |
Hazardous Locations | |||||
| Motor Voltage | Enclosure Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 | ||||||||||||
| AC, 60 Hz | |||||||||||||
| 115V | 200V | 230V | 50 Hz | 460… 575V |
Type 7 & 9 | Type 3R, 7 & 9§ | |||||||
| 380… 415V |
Cat. No. | Cat. No. | Cat. No. | Cat. No. | Cat. No. | Cat. No. | |||||||
| Push Button | 1 Æ | 0 | 1 | — | 2 | — | — | 609U-AOÄ | 609U-AAÄ | 609U-AJÄ | 609U-ACÄ | 609U-AEÄ | 609U-AHÄ |
| 1 | 2 | — | 3 | — | — | 609U-BOÄ | 609U-BAÄ | 609U-BJÄ | 609U-BCÄ | 609U-BEÄ | 609U-BHÄ | ||
| 1P | 3 | — | 5 | — | — | 609U-XOÄ | 609U-XAÄ | 609U-XJÄ | 609U-XCÄ | — | — | ||
| 3 Æ | 0 | — | 3 | 3 | 5 | 5 | 609U-AOÄ | 609U-AAÄ | 609U-AJÄ | 609U-ACÄ | 609U-AEÄ | 609U-AHÄ | |
| 1 | — | 7-1/2 | 7-1/2 | 10 | 10 | 609U-BOÄ | 609U-BAÄ | 609U-BJÄ | 609U-BCÄ | 609U-BEÄ | 609U-BHÄ | ||
| Toggle Lever | 1 Æ | 0 | 1 | — | 2 | — | — | 609TU-AOÄ | 609TU-AAÄ | — | — | — | — |
| 1 | 2 | — | 3 | — | — | 609TU-BOÄ | 609TU-BAÄ | — | — | — | — | ||
| 1P | 3 | — | 5 | — | — | 609TU-XOÄ | 609TU-XAÄ | — | — | — | — | ||
| 3 Æ | 0 | — | 3 | 3 | 5 | 5 | 609TU-AOÄ | 609TU-AAÄ | — | — | — | — | |
| 1 | — | 7-1/2 | 7-1/2 | 10 | 10 | 609TU-BOÄ | 609TU-BAÄ | — | — | — | — | ||
| ★ Type 1 general purpose flush mounting enclosures with pull box are also available. Order as follows. Change the second letter of the listed cat. no. from A to L. Example: Cat. No. 609U-ALX. For a stainless steel flush plate, change the second letter of the listed cat. no. from A to Q. Example: Cat. No. 609U-AQX. | |||||||||||||
| Fiberglass-reinforced polyester hubs are included with each starter. | |||||||||||||
| § These enclosures include a cover gasket and drain. It is recommended that a breather also be installed. | |||||||||||||
| Breather | Cat. No. 1401-N1 | (Can be installed at the top of an enclosure.) |
| Drain | Cat. No. 1401-N2 | (Can be installed at the bottom of an enclosure.) |
| Breather-Drain Combination | Cat. No. 1401-N3 | (Can be installed at the top of an enclosure as a breather or bottom as a drain.) |
Ä Coil Voltage Code for 1-Phase
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 609U-AOÄ becomes Cat. No. 609U-AOXA. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| [V] | 24 | 110…115 | 115…120 | 200…208 | 220…230 | 230…240 | 240 | 277 | ||
| Common Control | 50 Hz | — | XS | — | — | XP | — | XG | — | |
| 60 Hz | — | XE | XD | XH | XF | XA | — | — | ||
| Separate Control | 50 Hz | — | XWS | — | — | XWP | — | XWT | — | |
| 60 Hz | XWJ | — | XWD | XWH | — | XWA | — | XWF | ||
Ä Coil Voltage Code for 3-Phase
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 609U-AAÄ becomes Cat. No. 609U-AAA. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| [V] | 24 | 110 | 115… 120 | 200… 208 | 220… 230 | 230… 240 | 240 | 277 | 380 | 415 | 440… 460 | 460… 480 | 500 | 550 | 575… 600 | ||
| Common Control | 50 Hz | — | — | — | — | P | — | VP | — | VN | WL | Q | — | WM | R | — | |
| 60 Hz | — | — | — | H | F | A | — | G | — | — | N | B | — | WC | C | ||
| Separate Control | 50 Hz | K | S | — | — | — | — | — | — | — | — | — | — | — | — | — | |
| 60 Hz | WJ | E | D | — | — | — | — | WF | — | — | — | — | — | — | — | ||
Remote Stop Function
A remote stop function may be added by removing a short jumper (see typical diagram) and wiring a push button or limit switch in series with the solenoid. After operation of the emergency stop, the starter must be manually reset.
Note:The remote stop terminal block and jumper are not available on devices in the Type 7 and 9 enclosure.
Modifications
Pilot Light Kits
Kits are available for field installation of pilot lights in Type 1 general purpose surface or flush mounting enclosures. A clear lens is provided as standard. Pilot lights are not available for Bulletin 609RS or 609TS manual starters.
| Volts [V] | NEMA Type | Cat. No. |
| 120 | Type 1 | 609-N10 |
| 240 | 609-N20 | |
| 480 | 609-N40 | |
| 600 | 609-N60 | |
Pilot Lights Factory Installed
To order, add the number 4 after the last letter in the listed cat. no. Example: Cat. No. 609U-AAXD becomes Cat. No. 609U-AAXD4. Available for Type 1 general purpose enclosure only.
Note:Replacement lamp is ANSI part number B2A (NE-51H), Allen-Bradley Cat. No. 609-N9.
Group Fusing
The Bulletin 609U and 609TU Sizes 0 and 1 in Type 1, 4/4X, and 3R/12 enclosures are UL Listed for group fusing with Class J fuses only. See table below for maximum fuse ratings.
| Full Load Current of Smallest Motor Amperes [A] |
Maximum Fuse Ratings [A] | |
| Nominal System Voltages | ||
| 120…240V | 480…600V | |
| 0.45…2.99 | 30 | 30 |
| 3.00…6.49 | 60 | 30 |
| 6.50…18.0 | 100 | — |
Typical Wiring Diagram
(See Applicable Codes and Laws)
|
★ Remove Jumper A to connect remote stop operator wires to vacated terminals.
Note:Jumper not available on devices in Type 7 and 9 Enclosure.
Approximate Dimensions
Bulletin 609 609U
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
NEMA Type 1
|
|
|
|
|||
| Surface Mounting | Flush Mounting for Plaster Wall | Flush Mounting for Machine Cavity | Flush Mounting Cavity and Drilling Layout |
NEMA Type 4/4X
|
|
|
| Open Type — Without Enclosure |
★ Undervoltage solenoid applies only to Bulletins 609U and 609TU.
Bulletin 609 609U, Continued
Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
NEMA Type 3R, 7 & 9
|
NEMA Type 7 & 9
|
NEMA Type 12
|
Bulletin 609RS, 609TS
Open Type Without Enclosure
|
NEMA Type 1
|