Bulletin 609U with Under Voltage Protection

Product Overview


Click to enlarge - 609U-1_156-1


Bulletin 609U


Bulletins 609U and 609TU are the same as the standard Bulletin 609 Manual Starters except for the addition of undervoltage protection. These starters provide full line voltage starting, thermal overload protection, as well as undervoltage protection. Typical applications are on woodworking machinery, metal sawing machines, and many other machine tools where undervoltage protection is needed to meet safety standards. The undervoltage protection is accomplished by an electromechanical solenoid which is energized whenever line voltage is present. The solenoid is designed to mechanically open the starter contacts upon power failure, and keep them open even if power is returned to the unit. Only after the starter has been manually reset by pushing the operator to the stop position, can the starter be re-energized.
Open Type Bulletin 609U and 609TU switches can replace the Bulletin 609 switches in Types 1 and 12 enclosures of the latest construction without any field modification of the enclosure.


Standards Compliance and Certifications

Standards Compliance


Certifications



Your order must include: 1) Cat. No. of the manual starting switch with undervoltage protection, 2) Cat. No. of the heater element(s), and 2) if required, Cat. No. of any accessories.

Build a Catalog Number


Product Selection

With Undervoltage Protection

Type Of Operator Phase Size Maximum Horsepower Rating Open Type
without
Enclosure
Type 1
General
Purpose
Enclosure
Surface
Mounting
★ 
Type 12
Dusttight,
Industrial
Use
Enclosure
Type 4/4X
Watertight,
Corrosion-
Resistant
Enclosure
Fiberglass-
Reinforced
Polyester‡ 
Hazardous Locations
Motor Voltage Enclosure Class I, Groups C & D Class II, Groups E, F & G – Divisions 1 & 2
AC, 60 Hz
115V 200V 230V 50 Hz 460…
575V
Type 7 & 9 Type 3R, 7 & 9§ 
380…
415V
Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
Push Button 1 Æ 0 1 2 609U-AOÄ 609U-AAÄ 609U-AJÄ 609U-ACÄ 609U-AEÄ 609U-AHÄ
1 2 3 609U-BOÄ 609U-BAÄ 609U-BJÄ 609U-BCÄ 609U-BEÄ 609U-BHÄ
1P 3 5 609U-XOÄ 609U-XAÄ 609U-XJÄ 609U-XCÄ
3 Æ 0 3 3 5 5 609U-AOÄ 609U-AAÄ 609U-AJÄ 609U-ACÄ 609U-AEÄ 609U-AHÄ
1 7-1/2 7-1/2 10 10 609U-BOÄ 609U-BAÄ 609U-BJÄ 609U-BCÄ 609U-BEÄ 609U-BHÄ
Toggle Lever 1 Æ 0 1 2 609TU-AOÄ 609TU-AAÄ
1 2 3 609TU-BOÄ 609TU-BAÄ
1P 3 5 609TU-XOÄ 609TU-XAÄ
3 Æ 0 3 3 5 5 609TU-AOÄ 609TU-AAÄ
1 7-1/2 7-1/2 10 10 609TU-BOÄ 609TU-BAÄ
  
★ Type 1 general purpose flush mounting enclosures with pull box are also available. Order as follows. Change the second letter of the listed cat. no. from A to L. Example: Cat. No. 609U-ALX. For a stainless steel flush plate, change the second letter of the listed cat. no. from A to Q. Example: Cat. No. 609U-AQX.
‡ Fiberglass-reinforced polyester hubs are included with each starter.
§ These enclosures include a cover gasket and drain. It is recommended that a breather also be installed.

Breather Cat. No. 1401-N1 (Can be installed at the top of an enclosure.)
Drain Cat. No. 1401-N2 (Can be installed at the bottom of an enclosure.)
Breather-Drain Combination Cat. No. 1401-N3 (Can be installed at the top of an enclosure as a breather or bottom as a drain.)
  

Ä Coil Voltage Code for 1-Phase

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 609U-AOÄ becomes Cat. No. 609U-AOXA. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.

  [V] 24 110…115 115…120 200…208 220…230 230…240 240 277
Common Control 50 Hz XS XP XG
60 Hz XE XD XH XF XA
Separate Control 50 Hz XWS XWP XWT
60 Hz XWJ XWD XWH XWA XWF
  

Ä Coil Voltage Code for 3-Phase

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 609U-AAÄ becomes Cat. No. 609U-AAA. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.

  [V] 24 110 115… 120 200… 208 220… 230 230… 240 240 277 380 415 440… 460 460… 480 500 550 575… 600
Common Control 50 Hz P VP VN WL Q WM R
60 Hz H F A G N B WC C
Separate Control 50 Hz K S
60 Hz WJ E D WF
  

Remote Stop Function

A remote stop function may be added by removing a short jumper (see typical diagram) and wiring a push button or limit switch in series with the solenoid. After operation of the emergency stop, the starter must be manually reset.
Note:The remote stop terminal block and jumper are not available on devices in the Type 7 and 9 enclosure.


Modifications

Pilot Light Kits

Kits are available for field installation of pilot lights in Type 1 general purpose surface or flush mounting enclosures. A clear lens is provided as standard. Pilot lights are not available for Bulletin 609RS or 609TS manual starters.

Volts [V] NEMA Type Cat. No.
120 Type 1 609-N10
240 609-N20
480 609-N40
600 609-N60
  

Pilot Lights Factory Installed

To order, add the number 4 after the last letter in the listed cat. no. Example: Cat. No. 609U-AAXD becomes Cat. No. 609U-AAXD4. Available for Type 1 general purpose enclosure only.
Note:Replacement lamp is ANSI part number B2A (NE-51H), Allen-Bradley Cat. No. 609-N9.


Group Fusing

The Bulletin 609U and 609TU Sizes 0 and 1 in Type 1, 4/4X, and 3R/12 enclosures are UL Listed for group fusing with Class J fuses only. See table below for maximum fuse ratings.

Full Load Current of Smallest
Motor Amperes [A]
Maximum Fuse Ratings [A]
Nominal System Voltages
120…240V 480…600V
0.45…2.99 30 30
3.00…6.49 60 30
6.50…18.0 100
  

Typical Wiring Diagram

(See Applicable Codes and Laws)

Click to enlarge - 609U-1_158-1


★ Remove Jumper “A” to connect remote stop operator wires to vacated terminals.
Note:Jumper not available on devices in Type 7 and 9 Enclosure.


Approximate Dimensions

Bulletin 609 – 609U

Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

NEMA Type 1

Click to enlarge - 609-1_159-1   Click to enlarge - 609-1_159-2   Click to enlarge - 609-1_159-3   Click to enlarge - 609-1_159-4
Surface Mounting Flush Mounting for Plaster Wall Flush Mounting for Machine Cavity Flush Mounting Cavity and Drilling Layout

NEMA Type 4/4X

Click to enlarge - 609-1_159-5   Click to enlarge - 609-1_159-6
     Open Type — Without Enclosure

★ Undervoltage solenoid applies only to Bulletins 609U and 609TU.


Bulletin 609 – 609U, Continued

Dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

NEMA Type 3R, 7 & 9

Click to enlarge - 609-1_160-1


NEMA Type 7 & 9

Click to enlarge - 609-1_160-2


NEMA Type 12

Click to enlarge - 609-1_160-3


Bulletin 609RS, 609TS

Open Type Without Enclosure

Click to enlarge - 609-1_160-4


NEMA Type 1