Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Manual Motor Starters > Bulletin 609U with Under Voltage Protection
Bulletin 609U with Under Voltage Protection
| Introduction | Standards Compliance and Certifications | Product Selection | Modifications | Approximate Dimensions |
| Build a Catalog Number |
Product Selection
With Undervoltage Protection
| Type Of Operator | Phase | Size | Maximum Horsepower Rating | Open Type without Enclosure |
Type 1 General Purpose Enclosure Surface Mounting★ |
Type 12 Dusttight, Industrial Use Enclosure |
Type 4/4X Watertight, Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester |
Hazardous Locations | |||||
| Motor Voltage | Enclosure Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 | ||||||||||||
| AC, 60 Hz | |||||||||||||
| 115V | 200V | 230V | 50 Hz | 460… 575V |
Type 7 & 9 | Type 3R, 7 & 9§ | |||||||
| 380… 415V |
Cat. No. | Cat. No. | Cat. No. | Cat. No. | Cat. No. | Cat. No. | |||||||
| Push Button | 1 Æ | 0 | 1 | — | 2 | — | — | 609U-AOÄ | 609U-AAÄ | 609U-AJÄ | 609U-ACÄ | 609U-AEÄ | 609U-AHÄ |
| 1 | 2 | — | 3 | — | — | 609U-BOÄ | 609U-BAÄ | 609U-BJÄ | 609U-BCÄ | 609U-BEÄ | 609U-BHÄ | ||
| 1P | 3 | — | 5 | — | — | 609U-XOÄ | 609U-XAÄ | 609U-XJÄ | 609U-XCÄ | — | — | ||
| 3 Æ | 0 | — | 3 | 3 | 5 | 5 | 609U-AOÄ | 609U-AAÄ | 609U-AJÄ | 609U-ACÄ | 609U-AEÄ | 609U-AHÄ | |
| 1 | — | 7-1/2 | 7-1/2 | 10 | 10 | 609U-BOÄ | 609U-BAÄ | 609U-BJÄ | 609U-BCÄ | 609U-BEÄ | 609U-BHÄ | ||
| Toggle Lever | 1 Æ | 0 | 1 | — | 2 | — | — | 609TU-AOÄ | 609TU-AAÄ | — | — | — | — |
| 1 | 2 | — | 3 | — | — | 609TU-BOÄ | 609TU-BAÄ | — | — | — | — | ||
| 1P | 3 | — | 5 | — | — | 609TU-XOÄ | 609TU-XAÄ | — | — | — | — | ||
| 3 Æ | 0 | — | 3 | 3 | 5 | 5 | 609TU-AOÄ | 609TU-AAÄ | — | — | — | — | |
| 1 | — | 7-1/2 | 7-1/2 | 10 | 10 | 609TU-BOÄ | 609TU-BAÄ | — | — | — | — | ||
| ★ Type 1 general purpose flush mounting enclosures with pull box are also available. Order as follows. Change the second letter of the listed cat. no. from A to L. Example: Cat. No. 609U-ALX. For a stainless steel flush plate, change the second letter of the listed cat. no. from A to Q. Example: Cat. No. 609U-AQX. | |||||||||||||
| Fiberglass-reinforced polyester hubs are included with each starter. | |||||||||||||
| § These enclosures include a cover gasket and drain. It is recommended that a breather also be installed. | |||||||||||||
| Breather | Cat. No. 1401-N1 | (Can be installed at the top of an enclosure.) |
| Drain | Cat. No. 1401-N2 | (Can be installed at the bottom of an enclosure.) |
| Breather-Drain Combination | Cat. No. 1401-N3 | (Can be installed at the top of an enclosure as a breather or bottom as a drain.) |
Ä Coil Voltage Code for 1-Phase
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 609U-AOÄ becomes Cat. No. 609U-AOXA. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| [V] | 24 | 110…115 | 115…120 | 200…208 | 220…230 | 230…240 | 240 | 277 | ||
| Common Control | 50 Hz | — | XS | — | — | XP | — | XG | — | |
| 60 Hz | — | XE | XD | XH | XF | XA | — | — | ||
| Separate Control | 50 Hz | — | XWS | — | — | XWP | — | XWT | — | |
| 60 Hz | XWJ | — | XWD | XWH | — | XWA | — | XWF | ||
Ä Coil Voltage Code for 3-Phase
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 609U-AAÄ becomes Cat. No. 609U-AAA. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| [V] | 24 | 110 | 115… 120 | 200… 208 | 220… 230 | 230… 240 | 240 | 277 | 380 | 415 | 440… 460 | 460… 480 | 500 | 550 | 575… 600 | ||
| Common Control | 50 Hz | — | — | — | — | P | — | VP | — | VN | WL | Q | — | WM | R | — | |
| 60 Hz | — | — | — | H | F | A | — | G | — | — | N | B | — | WC | C | ||
| Separate Control | 50 Hz | K | S | — | — | — | — | — | — | — | — | — | — | — | — | — | |
| 60 Hz | WJ | E | D | — | — | — | — | WF | — | — | — | — | — | — | — | ||
Remote Stop Function
A remote stop function may be added by removing a short jumper (see typical diagram) and wiring a push button or limit switch in series with the solenoid. After operation of the emergency stop, the starter must be manually reset.
Note:The remote stop terminal block and jumper are not available on devices in the Type 7 and 9 enclosure.