Combination Contactors, Starters, and Pump Control Panels

Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Combination Contactors, Starters, and Pump Control Panels > Bulletin 1233X Pump Control Panels

Bulletin 1233X Pump Control Panels

Introduction Standards Compliance and Certifications Configuration of a Basic Combination Starter Product Selection Modifications for Combination Devices
Accessories Specifications Full Load Motor Currents Approximate Dimensions Renewal Parts
Product Selection

Build a Catalog Number


Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements. Located on Eutectic Alloy Overload Relay Heater Elements.
NEMA Size Continuous Ampere Rating [A]⋆  Maximum Horsepower Rating
Full Load Current Must Not Exceed Continuous Ampere Rating
Type 3R
Rainproof with Extra Panel Space
Motor Voltage
200V 230V 460V 575V Cat. No.
1 27 0…1/3 0…1/3 1233X-BNÄ-µ-32
1/2…1 1/2…1 0…1 0…1 1233X-BNÄ-µ-35
1-1/2…3 1-1/2…3 1-1/2…3 1-1/2…3 1233X-BNÄ-µ-38
5 1233X-BNÄ-µ-39
7-1/2 5…7-1/2 5…7-1/2 5…7-1/2 1233X-BNÄ-µ-40
10 10 1233X-BNÄ-µ-41
2 45 10 10 1233X-CNÄ-µ-41
15 15 15 1233X-CNÄ-µ-42
20…25 20…25 1233X-CNÄ-µ-44
3 90 15…25 25 1233X-DNÄ-µ-44
30 30 1233X-DNÄ-µ-45
30…50 40…50 1233X-DNÄ-µ-47
4 135 30 1233X-ENÄ-µ-45
40 40 1233X-ENÄ-µ-46
50 1233X-ENÄ-µ-47
60 1233X-ENÄ-µ-48
60…75 1233X-ENÄ-µ-49
100 75…100 1233X-ENÄ-µ-50
  
⋆ When controlling high efficiency motors – consult your local Rockwell Automation sales office or Allen-Bradley distributor for proper circuit breaker selection.

Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 1233X-BNÄ-µ-35 becomes Cat. No. 1233X-BNB-µ-35. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.


  [V] 208 230…240 460…480 575…600
Common Control AC, 60 Hz H A B C
Transformer Control (See Configuration of a Basic Combination Starter Note)
120V Separate Control (without transformer) AD AD CD CD
  

µ Overload Relay Code

Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Three-Phase Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no.
Example: Cat. No. 1233X-BNB-µ-35 becomes Cat. No. 1233X-BNB-A2E-35.


Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements. Located on Eutectic Alloy Overload Relay Heater Elements.
NEMA Size Continuous Ampere Rating [A]⋆  Maximum Horsepower Rating
Full Load Current Must Not Exceed Continuous Ampere Rating
Type 3R
Rainproof with Extra Panel Space
Motor Voltage
200V 230V 460V 575V Cat. No.
5 270 50…60 1233X-FNÄ-µ-48
75 60…75 1233X-FNÄ-µ-49
100 1233X-FNÄ-µ-50
125 1233X-FNÄ-µ-51
125…150 1233X-FNÄ-µ-52
200 150…200 1233X-FNÄ-µ-54
6 540 100 1233X-GNÄ-µ-50T
125 125 1233X-GNÄ-µ-51T
150 150 1233X-GNÄ-µ-52T
200 1233X-GNÄ-µ-54T
250 250 1233X-GNÄ-µ-56T
300 300 1233X-GNÄ-µ-57T
350 1233X-GNÄ-µ-58T
350…400 400 1233X-GNÄ-µ-59T
7 810 250 1233X-HNÄ-µ-56T
300 1233X-HNÄ-µ-57T
450…500 1233X-HNÄ-µ-61T
450…600 1233X-HNÄ-µ-62T
  
⋆ When controlling high efficiency motors – consult your local Rockwell Automation sales office or Allen‑Bradley distributor for proper circuit breaker selection.

Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 1233X-BNÄ-µ-35 becomes Cat. No. 1233X-BNB-µ-35. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.


  [V] 208 230…240 460…480 575…600
Common Control AC, 60 Hz H A B C
Transformer Control (See Configuration of a Basic Combination Starter Note)
120V Separate Control (without transformer) AD AD CD CD
  

µ Overload Relay Code

Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Three-Phase Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no.
Example: Cat. No. 1233X-BNB-µ-35 becomes Cat. No. 1233X-BNB-A2E-35.