Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Combination Contactors, Starters, and Pump Control Panels > Bulletin 1233X Pump Control Panels
Bulletin 1233X Pump Control Panels
| Introduction | Standards Compliance and Certifications | Configuration of a Basic Combination Starter | Product Selection | Modifications for Combination Devices |
| Accessories | Specifications | Full Load Motor Currents | Approximate Dimensions | Renewal Parts |
| Build a Catalog Number |
| Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements. Located on Eutectic Alloy Overload Relay Heater Elements. | ||||||
| NEMA Size | Continuous Ampere Rating [A]⋆ | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Type 3R Rainproof with Extra Panel Space |
|||
| Motor Voltage | ||||||
| 200V | 230V | 460V | 575V | Cat. No. | ||
| 1 | 27 | 0…1/3 | 0…1/3 | — | — | 1233X-BNÄ-µ-32 |
| 1/2…1 | 1/2…1 | 0…1 | 0…1 | 1233X-BNÄ-µ-35 | ||
| 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 1233X-BNÄ-µ-38 | ||
| 5 | — | — | — | 1233X-BNÄ-µ-39 | ||
| 7-1/2 | 5…7-1/2 | 5…7-1/2 | 5…7-1/2 | 1233X-BNÄ-µ-40 | ||
| — | — | 10 | 10 | 1233X-BNÄ-µ-41 | ||
| 2 | 45 | 10 | 10 | — | — | 1233X-CNÄ-µ-41 |
| — | 15 | 15 | 15 | 1233X-CNÄ-µ-42 | ||
| — | — | 20…25 | 20…25 | 1233X-CNÄ-µ-44 | ||
| 3 | 90 | 15…25 | 25 | — | — | 1233X-DNÄ-µ-44 |
| — | 30 | — | 30 | 1233X-DNÄ-µ-45 | ||
| — | — | 30…50 | 40…50 | 1233X-DNÄ-µ-47 | ||
| 4 | 135 | 30 | — | — | — | 1233X-ENÄ-µ-45 |
| 40 | 40 | — | — | 1233X-ENÄ-µ-46 | ||
| — | 50 | — | — | 1233X-ENÄ-µ-47 | ||
| — | — | — | 60 | 1233X-ENÄ-µ-48 | ||
| — | — | 60…75 | — | 1233X-ENÄ-µ-49 | ||
| — | — | 100 | 75…100 | 1233X-ENÄ-µ-50 | ||
| ⋆ When controlling high efficiency motors consult your local Rockwell Automation sales office or Allen-Bradley distributor for proper circuit breaker selection. | ||||||
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 1233X-BNÄ-µ-35 becomes Cat. No. 1233X-BNB-µ-35. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 208 | 230…240 | 460…480 | 575…600 | ||
| Common Control | AC, 60 Hz | H | A | B | C | |
| Transformer Control (See Configuration of a Basic Combination Starter Note) | ||||||
| 120V Separate Control (without transformer) | AD | AD | CD | CD | ||
µ Overload Relay Code
Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Three-Phase Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no.
Example: Cat. No. 1233X-BNB-µ-35 becomes Cat. No. 1233X-BNB-A2E-35.
| Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements. Located on Eutectic Alloy Overload Relay Heater Elements. | ||||||
| NEMA Size | Continuous Ampere Rating [A]⋆ | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Type 3R Rainproof with Extra Panel Space |
|||
| Motor Voltage | ||||||
| 200V | 230V | 460V | 575V | Cat. No. | ||
| 5 | 270 | 50…60 | — | — | — | 1233X-FNÄ-µ-48 |
| 75 | 60…75 | — | — | 1233X-FNÄ-µ-49 | ||
| — | 100 | — | — | 1233X-FNÄ-µ-50 | ||
| — | — | — | 125 | 1233X-FNÄ-µ-51 | ||
| — | — | 125…150 | — | 1233X-FNÄ-µ-52 | ||
| — | — | 200 | 150…200 | 1233X-FNÄ-µ-54 | ||
| 6 | 540 | 100 | — | — | — | 1233X-GNÄ-µ-50T |
| 125 | 125 | — | — | 1233X-GNÄ-µ-51T | ||
| 150 | 150 | — | — | 1233X-GNÄ-µ-52T | ||
| — | 200 | — | — | 1233X-GNÄ-µ-54T | ||
| — | — | 250 | 250 | 1233X-GNÄ-µ-56T | ||
| — | — | 300 | 300 | 1233X-GNÄ-µ-57T | ||
| — | — | — | 350 | 1233X-GNÄ-µ-58T | ||
| — | — | 350…400 | 400 | 1233X-GNÄ-µ-59T | ||
| 7 | 810 | — | 250 | — | — | 1233X-HNÄ-µ-56T |
| — | 300 | — | — | 1233X-HNÄ-µ-57T | ||
| — | — | 450…500 | — | 1233X-HNÄ-µ-61T | ||
| — | — | — | 450…600 | 1233X-HNÄ-µ-62T | ||
| ⋆ When controlling high efficiency motors consult your local Rockwell Automation sales office or Allen‑Bradley distributor for proper circuit breaker selection. | ||||||
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 1233X-BNÄ-µ-35 becomes Cat. No. 1233X-BNB-µ-35. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 208 | 230…240 | 460…480 | 575…600 | ||
| Common Control | AC, 60 Hz | H | A | B | C | |
| Transformer Control (See Configuration of a Basic Combination Starter Note) | ||||||
| 120V Separate Control (without transformer) | AD | AD | CD | CD | ||
µ Overload Relay Code
Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Three-Phase Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no.
Example: Cat. No. 1233X-BNB-µ-35 becomes Cat. No. 1233X-BNB-A2E-35.