Bulletin 1223 Oil Well Pump Control Panels

Click to enlarge - 1232X_1233X-1_85-1


Bulletin 1223


Standards Compliance and Certifications

Standards Compliance

UL 508A
CSA C22.2, No. 14


Certifications

cULus Listed (File No. E54866, Guide No. NITW)

Product Selection

NEMA Size Continuous Ampere Rating [A] Maximum Horsepower Rating
Full Load Current Must Not Exceed Continuous Ampere Rating
Type 3R¬ 
Motor Voltage 480V Motor Voltage 600V
Cat. No. Cat. No.
1 27 0…10 1223-BNB-µ 1223-BNC-µ
2 45 15…25 1223-CNB-µ 1223-CNC-µ
3 90 30…50 1223-DNB-µ 1223-DNC-µ
4 135 60…100 1223-ENB-µ 1223-ENC-µ
  

µ Overload Relay Code

Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset)
to complete the cat. no. Example: Cat. No. 1223-BNB-µ becomes Cat. No. 1223-BNB-A2E.


¬ If additional panel space is required, refer to publication 1223-BR001_-EN-P or consult your local Rockwell Automation sales office or Allen‑Bradley distributor.


Typical Wiring Diagram

Click to enlarge - 1223-1_82-2

Approximate Dimensions

Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing

Click to enlarge - 1223-1_82-3


Dimensions [mm (inches)]
NEMA
Size
A B C D E F G
1…4 508
(20)
724
(28-1/4)
387
(15-1/4)
664
(26-1/8)
121
(4-3/4)
10
(3/4)
635
(25)