Combination Contactors, Starters, and Pump Control Panels

Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Combination Contactors, Starters, and Pump Control Panels > Bulletin 506 Reversing Disconnect Type

Bulletin 506 Reversing Disconnect Type

Introduction Standards Compliance and Certifications Configuration of a Basic Combination Starter Product Selection Modifications for Combination Devices
Accessories Specifications Full Load Motor Currents Approximate Dimensions Renewal Parts
Product Selection

Build a Catalog Number


Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements. Located on Eutectic Alloy Overload Relay Heater Elements.
NEMA
Size
Cont.
Ampere
Rating
[A]
Max. Hp Rating
FLC Must Not Exceed
Continuous Amp Rating
Line
Voltage
[V]
Fuse Clip
Rating
Amperes
[A]
Fuses not
included.
Select per NEC
Type 1
General
Purpose
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
Type 3R/4/12
Rainproof,
Waterproof,
Dusttight
(Door Safety
Hardware)
Type 4/4X
Watertight
Corrosion-
Resistant
Stainless Steel
Motor Voltage
60 Hz 60 Hz 50 Hz 60 Hz
200V 230V 380…
415V
460…
575V
Cat. No.⋆ ‡ §  Cat. No. ⋆ ‡ §  Cat. No. ⋆ ‡ §  Cat. No. ⋆ ‡ 
0 18 3 3 208…240 30 506-AAÄ-µ-24R 506-AFÄ-µ-24R 506-AJÄ-µ-24R 506-ACÄ-µ-24R
5 5 480…600 30 506-AAÄ-µ-24R 506-AFÄ-µ-24R 506-AJÄ-µ-24R 506-ACÄ-µ-24R
1 27 7-1/2 7-1/2 208...240 30 506-BAÄ-µ-24R 506-BFÄ-µ-24R 506-BJÄ-µ-24R 506-BCÄ-µ-24R
10 10 480...600 30 506-BAÄ-µ-24R 506-BFÄ-µ-24R 506-BJÄ-µ-24R 506-BCÄ-µ-24R
7-1/2 7-1/2 208…240 60 506-BAÄ-µ-25R 506-BFÄ-µ-25R 506-BJÄ-µ-25R 506-BCÄ-µ-25R
10 10 480...600 60 506-BAÄ-µ-25R 506-BFÄ-µ-25R 506-BJÄ-µ-25R 506-BCÄ-µ-25R
2 45 25 25 480…600 30 506-CAÄ-µ-24R 506-CFÄ-µ-24R 506-CJÄ-µ-24R 506-CCÄ-µ-24R
10 15 208…240 60 506-CAÄ-µ-25R 506-CFÄ-µ-25R 506-CJÄ-µ-25R 506-CCÄ-µ-25R
25 25 480...600 60 506-CAÄ-µ-25R 506-CFÄ-µ-25R 506-CJÄ-µ-25R 506-CCÄ-µ-25R
10 15 208…240 100 506-CAÄ-µ-26R 506-CFÄ-µ-26R 506-CJÄ-µ-26R 506-CCÄ-µ-26J
25 25 480...600 100 506-CAÄ-µ-26J 506-CFÄ-µ-26J 506-CJÄ-µ-26J 506-CCÄ-µ-26J
3 90 50 50 480…600 60 506-DAÄ-µ-25J 506-DFÄ-µ-25J 506-DJÄ-µ-25J 506-CCÄ-µ-25R
25 30 208…240 100 506-DAÄ-µ-26R 506-DFÄ-µ-26R 506-DJÄ-µ-26R 506-DCÄ-µ-26R
50 50 480...600 100 506-DAÄ-µ-26R 506-DFÄ-µ-26R 506-DJÄ-µ-26R 506-DCÄ-µ-26R
25 30 208…240 200 506-DAÄ-µ-27J 506-DFÄ-µ-27J 506-DJÄ-µ-27J 506-DCÄ-µ-27J
50 50 480...600 200 506-DAÄ-µ-27J 506-DFÄ-µ-27J 506-DJÄ-µ-27J 506-DCÄ-µ-27J
4 135 75 100 480…600 100 506-EAÄ-µ-26R 506-EFÄ-µ-26R 506-EJÄ-µ-26R 506-ECÄ-µ-26R
40 50 208…240 200 506-EAÄ-µ-27R 506-EFÄ-µ-27R 506-EJÄ-µ-27R 506-ECÄ-µ-27R
75 100 480...600 200 506-EAÄ-µ-27R 506-EFÄ-µ-27R 506-EJÄ-µ-27R 506-ECÄ-µ-27R
100 480…600 400 506-EAÄ-µ-28R 506-EFÄ-µ-28R 506-EJÄ-µ-28R 506-ECÄ-µ-28R
75 100 480…600 400 506-EAÄ-µ-28J 506-EFÄ-µ-28J 506-EJÄ-µ-28J 506-ECÄ-µ-28J
5 270 75 100 208…240 400 506-FAÄ-µ-28R 506-FFÄ-µ-28R 506-FJÄ-µ-28R 506-FCÄ-µ-28R
150 200 480…600 400 506-FAÄ-µ-28R 506-FFÄ-µ-28R 506-FJÄ-µ-28R 506-FCÄ-µ-28R
  

⋆ Non-Fusible Disconnect Type

Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: Cat. No. 506-BFB-24R becomes Cat. No. 506-BFB.


‡ Class H fuse clips can be supplied. Example: Cat. No. 506-AAÄ-24R becomes Cat. No. 506-AAÄ-24. Class J fuse clips can be supplied. Example: Cat. No. 506-AAÄ-24R becomes Cat. No. 506-AAÄ-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 506-AAÄ-24R becomes Cat. No. 506-AAÄ-24E.
§ Bulletin 506 Narrow Enclosure — Sizes 0 & 1 are supplied in a (30 in. H x 20 in. W) enclosure. If a narrow enclosure (27 in. H x 10 in. W) is required, add the letter X to the Bulletin Number (506X). Only available in Type 1 or 12.


Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no.
Example: Cat. No. 506-AAÄ-µ-24R becomes Cat. No. 506-AAB-µ-24R. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.


  [V] 208 230…240 460…480 575…600
Common Control AC, 60 Hz H A B C
Transformer Control (See Configuration of a Basic Combination Starter Note)
120V Separate Control (without transformer) AD AD CD CD
  

µ Overload Relay Code

Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Three-Phase Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no.
Example: Cat. No. 506-AAB-µ-24R becomes Cat. No. 506-AAB-A2E-24R.