Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Combination Contactors, Starters, and Pump Control Panels > Bulletin 507 Reversing Circuit Breaker Type
Bulletin 507 Reversing Circuit Breaker Type
| Introduction | Standards Compliance and Certifications | Configuration of a Basic Combination Starter | Product Selection | Modifications for Combination Devices |
| Accessories | Specifications | Full Load Motor Currents | Approximate Dimensions | Renewal Parts |
| Build a Catalog Number |
| Heater Elements — Starters with eutectic alloy overload relay require 3 heater elements. Located on Eutectic Alloy Overload Relay Heater Elements. | |||||||||
| NEMA Size |
Continuous Ampere Rating [A]§ |
Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Type 1 General Purpose |
Type 3R/4/12 Rainproof, Waterproof, Dusttight |
Type 3R/4/12 Rainproof, Waterproof, Dusttight (Door Safety Hardware) |
Type 4/4X Watertight Corrosion Resistant Stainless Steel |
|||
| Motor Voltage | |||||||||
| 200V | 230V | 460V | 575V | Cat. No.⋆ | Cat. No.⋆ | Cat. No.⋆ | Cat. No.⋆ | ||
| 0 | 18 | 0…1/3 | 0…1/3 | — | — | 507-AAÄ-µ-32 | 507-AFÄ-µ-32 | 507-AJÄ-µ-32 | 507-ACÄ-µ-32 |
| 1/2…1 | 1/2…1 | 0…1 | 0…1 | 507-AAÄ-µ-35 | 507-AFÄ-µ-35 | 507-AJÄ-µ-35 | 507-ACÄ-µ-35 | ||
| 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 507-AAÄ-µ-38 | 507-AFÄ-µ-38 | 507-AJÄ-µ-38 | 507-ACÄ-µ-38 | ||
| — | — | 5 | 5 | 507-AAÄ-µ-39 | 507-AFÄ-µ-39 | 507-AJÄ-µ-39 | 507-ACÄ-µ-39 | ||
| 1 | 27 | 0…1/3 | 0…1/3 | — | — | 507-BAÄ-µ-32 | 507-BFÄ-µ-32 | 507-BJÄ-µ-32 | 507-BCÄ-µ-32 |
| 1/2…1 | 1/2…1 | 0…1 | 0…1 | 507-BAÄ-µ-35 | 507-BFÄ-µ-35 | 507-BJÄ-µ-35 | 507-BCÄ-µ-35 | ||
| 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 507-BAÄ-µ-38 | 507-BFÄ-µ-38 | 507-BJÄ-µ-38 | 507-BCÄ-µ-38 | ||
| 5 | — | — | — | 507-BAÄ-µ-39 | 507-BFÄ-µ-39 | 507-BJÄ-µ-39 | 507-BCÄ-µ-39 | ||
| 7-1/2 | 5…7-1/2 | 5…7-1/2 | 5…7-1/2 | 507-BAÄ-µ-40 | 507-BFÄ-µ-40 | 507-BJÄ-µ-40 | 507-BCÄ-µ-40 | ||
| — | — | 10 | 10 | 507-BAÄ-µ-41 | 507-BFÄ-µ-41 | 507-BJÄ-µ-41 | 507-BCÄ-µ-41 | ||
| 2 | 45 | 10 | 10 | — | — | 507-CAÄ-µ-41 | 507-CFÄ-µ-41 | 507-CJÄ-µ-41 | 507-CCÄ-µ-41 |
| — | 15 | 15 | 15 | 507-CAÄ-µ-42 | 507-CFÄ-µ-42 | 507-CJÄ-µ-42 | 507-CCÄ-µ-42 | ||
| — | — | 20…25 | 20…25 | 507-CAÄ-µ-44 | 507-CFÄ-µ-44 | 507-CJÄ-µ-44 | 507-CCÄ-µ-44 | ||
| 3 | 90 | 15…25 | 20…25 | — | — | 507-DAÄ-µ-44 | 507-DFÄ-µ-44 | 507-DJÄ-µ-44 | 507-DCÄ-µ-44 |
| — | 30 | — | 30 | 507-DAÄ-µ-45 | 507-DFÄ-µ-45 | 507-DJÄ-µ-45 | 507-DCÄ-µ-45 | ||
| — | — | 30…50 | 40…50 | 507-DAÄ-µ-47 | 507-DFÄ-µ-47 | 507-DJÄ-µ-47 | 507-DCÄ-µ-47 | ||
| 4 | 135 | 30 | — | — | — | 507-EAÄ-µ-45 | 507-EFÄ-µ-45 | 507-EJÄ-µ-45 | 507-ECÄ-µ-45 |
| 40 | 40 | — | — | 507-EAÄ-µ-46 | 507-EFÄ-µ-46 | 507-EJÄ-µ-46 | 507-ECÄ-µ-46 | ||
| — | 50 | — | — | 507-EAÄ-µ-47 | 507-EFÄ-µ-47 | 507-EJÄ-µ-47 | 507-ECÄ-µ-47 | ||
| — | — | — | 60 | 507-EAÄ-µ-48 | 507-EFÄ-µ-48 | 507-EJÄ-µ-48 | 507-ECÄ-µ-48 | ||
| — | — | 60…75 | — | 507-EAÄ-µ-49 | 507-EFÄ-µ-49 | 507-EJÄ-µ-49 | 507-ECÄ-µ-49 | ||
| — | — | 100 | 75…100 | 507-EAÄ-µ-50 | 507-EFÄ-µ-50 | 507-EJÄ-µ-50 | 507-ECÄ-µ-50 | ||
| 5 | 270 | 50…60 | 60 | — | — | 507-FAÄ-µ-48 | 507-FFÄ-µ-48 | 507-FJÄ-µ-48 | 507-FCÄ-µ-48 |
| 75 | — | — | — | 507-FAÄ-µ-49 | 507-FFÄ-µ-49 | 507-FJÄ-µ-49 | 507-FCÄ-µ-49 | ||
| — | 75…100 | — | — | 507-FAÄ-µ-50 | 507-FFÄ-µ-50 | 507-FJÄ-µ-50 | 507-FCÄ-µ-50 | ||
| — | — | — | 125 | 507-FAÄ-µ-51 | 507-FFÄ-µ-51 | 507-FJÄ-µ-51 | 507-FCÄ-µ-51 | ||
| — | — | 125…150 | 150 | 507-FAÄ-µ-52 | 507-FFÄ-µ-52 | 507-FJÄ-µ-52 | 507-FCÄ-µ-52 | ||
| — | — | 200 | 200 | 507-FAÄ-µ-54 | 507-FFÄ-µ-54 | 507-FJÄ-µ-54 | 507-FCÄ-µ-54 | ||
⋆ Bulletin 507 Narrow Enclosure — Sizes 0 & 1 are supplied in a (30 in. H x 20 in. W) enclosure. If a narrow enclosure (27 in. H x 10 in. W) is required, add the letter X to the Bulletin Number (507X).
To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: Cat. No. 507-BAÄ-µ-35V.
§ When controlling high efficiency motors consult your local Rockwell Automation sales office or Allen-Bradley distributor for proper circuit breaker selection.
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no.
Example: Cat. No. 507-BAÄ-µ-35 becomes Cat. No. 507-BAB-µ-35. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 208 | 230…240 | 460…480 | 575…600 | ||
| Common Control | AC, 60 Hz | H | A | B | C | |
| Transformer Control (See Configuration of a Basic Combination Starter Note) | ||||||
| 120V Separate Control (without transformer) | AD | AD | CD | CD | ||
µ Overload Relay Code
Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Single-Phase Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no.
Example: Cat. No. 507-BAB-µ-35 becomes Cat. No. 507-BAB-A2E-35.
| Heater Elements — Starters with eutectic alloy overload relay require 3 heater elements. Located on Bulletin 592. | |||||||
| NEMA Size |
Continuous Ampere Rating [A]§ |
Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Type 3R, 7 & 9 Bolted Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
Type 7 & 9 Bolted Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
|||
| Motor Voltage | |||||||
| 200V | 230V | 460V | 575V | Cat. No.⋆ | Cat. No. | ||
| 0 | 18 | 0…1/3 | 0…1/3 | — | — | 507-AHÄ-µ-32 | 507-AEÄ-µ-32 |
| 1/2…1 | 1/2…1 | 0…1 | 0…1 | 507-AHÄ-µ-35 | 507-AEÄ-µ-35 | ||
| 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 507-AHÄ-µ-38 | 507-AEÄ-µ-38 | ||
| — | — | 5 | 5 | 507-AHÄ-µ-39 | 507-AEÄ-µ-39 | ||
| 1 | 27 | 0…1/3 | 0…1/3 | — | — | 507-BHÄ-µ-32 | 507-BEÄ-µ-32 |
| 1/2…1 | 1/2…1 | 0…1 | 0…1 | 507-BHÄ-µ-35 | 507-BEÄ-µ-35 | ||
| 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 507-BHÄ-µ-38 | 507-BEÄ-µ-38 | ||
| 5 | — | — | — | 507-BHÄ-µ-39 | 507-BEÄ-µ-39 | ||
| 7-1/2 | 5…7-1/2 | 5…7-1/2 | 5…7-1/2 | 507-BHÄ-µ-40 | 507-BEÄ-µ-40 | ||
| — | — | 10 | 10 | 507-BHÄ-µ-41 | 507-BEÄ-µ-41 | ||
| 2 | 45 | 10 | 10 | — | — | 507-CHÄ-µ-41 | 507-CEÄ-µ-41 |
| — | 15 | 15 | 15 | 507-CHÄ-µ-42 | 507-CEÄ-µ-42 | ||
| — | — | 20…25 | 20…25 | 507-CHÄ-µ-44 | 507-CEÄ-µ-44 | ||
| 3 | 90 | 15…25 | 20…25 | — | — | 507-DHÄ-µ-44 | 507-DEÄ-µ-44 |
| — | 30 | — | 30 | 507-DHÄ-µ-45 | 507-DEÄ-µ-45 | ||
| — | — | 30…50 | 40…50 | 507-DHÄ-µ-47 | 507-DEÄ-µ-47 | ||
| 4 | 135 | 30 | — | — | — | 507-EHÄ-µ-45 | 507-EEÄ-µ-45 |
| 40 | 40 | — | — | 507-EHÄ-µ-46 | 507-EEÄ-µ-46 | ||
| — | 50 | — | — | 507-EHÄ-µ-47 | 507-EEÄ-µ-47 | ||
| — | — | — | 60 | 507-EHÄ-µ-48 | 507-EEÄ-µ-48 | ||
| — | — | 60…75 | — | 507-EHÄ-µ-49 | 507-EEÄ-µ-49 | ||
| — | — | — | 75…100 | 507-EHÄ-µ-50 | 507-EEÄ-µ-50 | ||
⋆ Includes drain and cover with gasket.
To order Visa-Window Breakers for certain mining applications (Canada only), add the letter V to the cat. no. Example: Cat. No. 507-BHÄ-µ-35V.
§ When controlling high efficiency motors consult your local Rockwell Automation sales office or Allen-Bradley distributor for proper circuit breaker selection.
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the cat. no.
Example: Cat. No. 507-BEÄ-µ-35 becomes Cat. No. 507-BEB-µ-35. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 208 | 230…240 | 460…480 | 575…600 | ||
| Common Control | AC, 60 Hz | H | A | B | C | |
| Transformer Control (See Configuration of a Basic Combination Starter Note) | ||||||
| 120V Separate Control (without transformer) | AD | AD | CD | CD | ||
µ Overload Relay Code
Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Three-Phase Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no.
Example: Cat. No. 507-BHB-µ-35 becomes Cat. No. 507-BHB-A2E-35.