Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Combination Contactors, Starters, and Pump Control Panels > Bulletin 1233V Vacuum Pump Control Panels
Bulletin 1233V Vacuum Pump Control Panels
| Introduction | Standards Compliance and Certifications | Configuration of a Basic Combination Starter | Product Selection | Modifications for Combination Devices | Accessories |
| Specifications | Full Load Motor Currents | Approximate Dimensions | Heater Element Selection | Renewal Parts |
For Use on Bulletins 502, 502L, 503, 503L, 506, 506X, 507, 507X, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 522, 522E, 522F, 522G, 523, 523E, 523F, 523G, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1232X, 1232V, 1233X, and 1233V
| Description of Modification | Suffix No. | Enclosure Type | NEMA Size | |||||||||
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | |||||
| Pilot Devices in Cover or Flange | ||||||||||||
| Full Voltage Non-Reversing Single Speed Starters | START-STOP push button | 1 1 1 1 |
1 3R/4/12, 4/4X Bolted Unilock |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
NA A NA NA |
NA A NA NA |
|
| ON-OFF push button | 1E 1E 1E 1E |
1 3R/4/12, 4/4X Bolted Unilock |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
NA A NA NA |
NA A NA NA |
||
| START-STOP illuminated push button | 1L 1L |
1 3R/4/12, 4/4X |
A A |
A A |
A A |
A A |
A A |
A A |
NA NA |
NA NA |
||
| HAND-OFF-AUTO selector switch | 3 3 3 3 |
1 3R/4/12, 4/4X Bolted Unilock |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
NA A NA NA |
NA A NA NA |
||
| OFF-ON selector switch | 3E 3E 3E 3E |
1 3R/4/12, 4/4X Bolted Unilock |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
NA A NA NA |
NA A NA NA |
||
| HAND-AUTO selector switch | 3H 3H 3H 3H |
1 3R/4/12, 4/4X Bolted Unilock |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
NA A NA NA |
NA A NA NA |
||
| PILOT LIGHT | Transformer Type — incandescent bulb |
4¬ T 4¬ T 4¬ T |
1, 3R/4/12, 4/4X, 3R Bolted Unilock |
A A A |
A A A |
A A A |
A A A |
A A A |
A A A |
A NA NA |
A NA NA |
|
| Transformer Type—LED bulb | 4L¬ T | 1, 3R/4/12, 4/4X, 3R | A | A | A | A | A | A | A | A | ||
| PUSH-TO-TEST PILOT LIGHT Transformer—incandescent bulb |
5¬ T 5¬ T |
1, 3R/4/12, 4/4X, 3R Bolted |
A A |
A A |
A A |
A A |
A A |
A A |
A A |
A A |
||
| 5L¬ T | 1, 3R/4/12, 4/4X, 3R | A | A | A | A | A | A | A | A | |||
| START-STOP push button and HAND-OFF-AUTO selector switch (unwired) | 13 13 |
1 3R/4/12, 4/4X |
A A |
A A |
A A |
A A |
A A |
A A |
A A |
A A |
||
| Full Voltage Reversing and Multi-Speed Starters | FOR-REV-STOP push button | Bulletin 506…507 | 1 | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA |
| Bulletin 507 | 1 | Bolted (7 & 9) | A | A | A | A | A | A | NA | NA | ||
| FOR-OFF-REV selector switch (Bulletin 506…507) | 3 3 3 |
1, 3R/4X12, 4/4X, 3R Bolted Unilock |
A A A |
A A A |
A A A |
A A A |
A A A |
A A A |
NA NA NA |
NA NA NA |
||
| HAND-AUTO | 3H 3H 3H 3H |
1 3R/4/12, 4/4X, Bolted Unilock |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
NA NA NA NA |
NA NA NA NA |
||
| HIGH-LOW-STOP push button | Bulletin 522…523 | 1 | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | |
| Bulletin 523 | 1 | Bolted | A | A | A | A | A | A | NA | NA | ||
| HIGH-OFF-LOW selector switch | Bulletin 522…523 | 3 | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | |
| Bulletin 523 | 3 | Bolted | A | A | A | A | A | A | NA | NA | ||
| HIGH-LOW-OFF-AUTO selector switch | 3J | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | ||
| PILOT LIGHT (2) | Transformer Type — Incandescent Bulb |
4T | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | |
| Transformer Type—LED Bulb | 4L | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | ||
| PUSH-TO-TEST PILOT LIGHT | Transformer— Incandescent Bulb | 5T | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | |
| Transformer—LED Bulb | 5L* | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | ||
| ¬ OFF pilot lights for non-reversing and non-multi-speed applications require a normally closed auxiliary contact (-91). | ||||||||||||
| T The suffix number is incomplete. Specify the lens with the following letters: A = Amber; B = Blue; C = Clear; G = Green; W = White. | ||||||||||||
| For multi-speed and reversing starters, one pilot light for each container. Add additional letter to identify two lens colors. The first letter specifies FORWARD or HIGH, or ON; the second letter specifies REVERSE or LOW , or OFF; e.g. 4AG. | ||||||||||||
A = Available, NA = Not Available |
||||||||||||
For Use on Bulletins 502, 502L, 503, 503L, 506, 506X, 507, 507X, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 522, 522E, 522F, 522G, 523, 523E, 523F, 523G, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1232X, 1232V, 1233X, and 1233V, Continued
| Description of Modification | Suffix No. | Enclosure Type | NEMA Size | |||||||||
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | |||||
| Control Circuit Transformers Includes 2 Primary Fuses and 1 Secondary Fuse | With standard capacity, 60 or 50 Hz With standard capacity with fuse covers With standard capacity, 60 or 50 Hz With standard capacity, 60 or 50 Hz |
6P 6PC 6P 6P |
1, 3R/4X/12, 4/4X, 3R 1, 3R/4X/12, 4/4X, 3R Bolted¬ UnilockT |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A NA NA |
A A NA NA |
|
| With 100 W extra capacity, 60 or 50 Hz With 100 W extra capacity with fuse covers With 100 W extra capacity, 60 or 50 Hz With 100 W extra capacity, 60 or 50 Hz |
6XP 6XPC 6XP 6XP |
1, 3R/4X/12, 4/4X, 3R 1, 3R/4X/12, 4/4X, 3R Bolted¬ UnilockT |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A A A |
A A NA NA |
A A NA NA |
||
| With 200VA capacity With 200VA capacity with fuse covers With 200 W extra capacity, 60 or 50 Hz With 200 W extra capacity with fuse covers |
6XXP 6XXPC 6YP 6YPC |
1, 3R/4X/12, 4/4X, 3R 1, 3R/4X/12, 4/4X, 3R 1, 3R/4X/12, 4/4X, 3R 1, 3R/4X/12, 4/4X, 3R |
A A A A |
A A A A |
A A A A |
NA NA A A |
NA NA A A |
NA NA A A |
NA NA NA NA |
NA NA NA NA |
||
| With 300 W extra capacity, 60 or 50 Hz With 300 W extra capacity with fuse covers |
6XYP 6XYPC |
1, 3R/4X/12, 4/4X, 3R 1, 3R/4X/12, 4/4X, 3R |
A A |
A A |
A A |
A A |
A A |
A A |
NA NA |
NA NA |
||
| With 400 W extra capacity, 60 or 50 Hz With 400 W extra capacity with fuse covers |
6YYP 6YYPC |
1, 3R/4X/12, 4/4X, 3R 1, 3R/4X/12, 4/4X, 4X |
A A |
A A |
A A |
A A |
A A |
A A |
NA NA |
NA NA |
||
| Auxiliary Contacts | Auxiliary contact installed on contactors |
N.O. N.C. |
90 91 |
1, 3R/4X/12, 4/4X Bolted |
A A |
A A |
A A |
A A |
A A |
A A |
A NA |
A NA |
| Auxiliary contact — contactor (four maximum) N.C. — late break |
97 | 1, 3R/4/12, 4/4X, 3R | A | A | A | A | A | A | NA | NA | ||
| Auxiliary contact installed on disconnect | N.O. N.C. |
98 99 |
1, 3R/4/12, 4/4X, 3R 1, 3R/4/12, 4/4X, 3R |
A A |
A A |
A A |
A A |
A A |
A A |
A A |
A A |
|
| Auxiliary contact installed on circuit breaker (external to breaker) to operate with handle (two maximum) | N.O. N.O. N.O. |
98 98 98 |
1, 3R/4X/12, 4/4X, 3R Bolted¬ UnilockT |
A A A |
A A A |
A A A |
A A A |
A A A |
A A A |
A NA NA |
A NA NA |
|
| N.C. N.C. N.C. |
99 99 99 |
1, 3R/4X/12, 4/4X, 3R Bolted¬ UnilockT |
A A A |
A A A |
A A A |
A A A |
A A A |
A A A |
A NA NA |
A NA NA |
||
| Control Circuit | Control circuit fuse block less transformer | 1 Fuse — Fuse Included | 21 | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | A | A |
| 1 Fuse with Protective Cover — Fuse Included |
21C | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | A | A | ||
| 2 Fuses — Fuses Included | 22 | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | A | A | ||
| 2 Fuse with Protective Cover — Fuse Included |
22C | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | A | A | ||
| Surge suppression for 120V or 240V AC Coil | 17 | 1, 3R/4X/12, 4/4X, 3R Bolted¬ UnilockT |
A | A | A | A | A | A | NA | NA | ||
| Terminal blocks (Cat No. 1492-HC6) |
6-Point Block | TB6 | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | A | A | |
| Terminal blocks (Cat No. 1492-HC12) |
12-Point Block | TB12 | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | A | A | |
| Overload Relays (Eutectic Alloy) |
N.O. alarm contact adder (Bulletin 592) | 9 | 1, 3R/4X/12, 4/4X, 3R Bolted¬ UnilockT |
A | A | A | A | A | A | NA | NA | |
| N.C. alarm contact adder (Bulletin 592) | 9A | A | A | A | A | A | A | NA | NA | |||
| Omit three overload relays | For Bulletins 506, 506X, 507, 507X Deduct | 23 | 1, 3R/4X/12, 4/4X, 3R Bolted¬ UnilockT |
A | A | A | A | A | A | NA | NA | |
| For Bulletins 522, 523 Deduct | 23 | A | A | A | A | A | A | NA | NA | |||
| Accessories | 3-phase Powermonitor (Timemark Model 258) | 400 | 1, 3R/4X/12, 4/4X, 3R Bolted (3R, 7 & 9) Unilock (7 & 9) |
A | A | A | A | A | A | A | A | |
| Bulletin 596 (used on Bulletin 500…509), 3-pole maximum | On Delay Off Delay |
87A 87B |
A A |
A A |
A A |
A A |
A A |
A A |
NA NA |
NA NA |
||
| Form A compelling relay (used on Bulletin 522…523) | 70 | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | ||
| Form B auto. seq. accelerating relay for each higher speed (used on Bulletin 522…523) | 71 | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | ||
| Form C auto. seq. decelerating relay for each higher speed (used on Bulletin 522…523) | 72 | 1, 3R/4/12, 4/4X | A | A | A | A | A | A | NA | NA | ||
| ¬ Bolted suitable for Type 7 & 9 or Type 3R, 7 & 9. | ||||||||||||
| T Unilock suitable for Type 7 & 9 or Type 3R, 7 & 9 with the addition of a drain or a breather and drain. White LED option not available, incandescent only. | ||||||||||||
| For Bulletins 506, 507, 522 and 523 devices. One auxiliary contact is installed on each of the two contactors. | ||||||||||||
A = Available, NA = Not Available |
||||||||||||
For Use on Bulletins 502, 502L, 503, 503L, 506, 506X, 507, 507X, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 522, 522E, 522F, 522G, 523, 523E, 523F, 523G, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1232X, 1232V, 1233X, and 1233V, Continued
| Description of Modification | Suffix No. | Enclosure Type | NEMA Size | |||||||||
| 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | |||||
| Circuit Breakers | Marine Requirements | 345 | — | A | A | A | A | A | A | NA | NA | |
| Current Limiters | Add the letter C to the instantaneous circuit breaker no. code. | C | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | NA | NA | |
| Thermal Magnetic Circuit Breakers | Add the letter T to the circuit breaker no. code. | T | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | S | S | |
| Current Limiters | Add the letter D to the inverse time circuit breaker no. code. | D | 1, 3R/4X/12, 4/4X, 3R | A | A | A | A | A | A | NA | NA | |
| Accessories | Enclosure | Breather | 136 | Bolted¬ | A | A | A | A | A | A | NA | NA |
| Breather and drain | 137 | Unilock and Bolted¬ T | A | A | A | A | A | A | NA | NA | ||
| Drain | 138 | Bolted and Unilock¬ T | A | A | A | A | A | A | NA | NA | ||
| Enclosure Door Viewing Window | 203W | 1, 3R/4/12, 3R | A | A | A | A | A | A | NA | NA | ||
| Handles For Disconnect Switch or Circuit Breaker |
Painted metal Stainless steel Molded plastic (deduct) |
412 413 419 |
1, 3R/4/12, 3R 4/4X 1, 3R/4/12, 4/4X, 3R |
A A A |
A A A |
A A A |
A A A |
A A A |
S S NA |
S S NA |
S S NA |
|
| Fuse Cover | Protective fuse cover for disconnect switch | 414 | 1, 3R/4/12, 4/4X, 3R | A | A | A | A | A | A | NA | NA | |
| Control Relay (Plug-In) |
2-Pole 3-Pole |
415 416 |
1, 3R/4/12, 4/4X, 3R | A A |
A A |
A A |
A A |
A A |
A A |
A A |
A A |
|
| Timing Relay (Plug-In) |
On-Delay Off-Delay |
417 418 |
1, 3R/4/12, 4/4X, 3R | A A |
A A |
A A |
A A |
A A |
A A |
A A |
A A |
|
| Electrical Interlock | Early Break (1 N.O. and 1 N.C.) Early Break (2 N.O. and 2 N.C.) |
420 421 |
1, 3R/4/12, 4/4X, 3R 1, 3R/4/12, 4/4X, 3R |
A A |
A A |
A A |
A A |
A A |
A A |
NA NA |
NA NA |
|
| Bracket Mounting Feet for Pump Panels | 424 | 3R | NA | A | A | A | A | A | NA | NA | ||
| Elapsed Time Meter (ENM - Series T50) | 425 | 3R | NA | A | A | A | A | A | A | A | ||
| Protective Covers for Contactors and Starters | 426 | 1, 3R/12, 4/4X, 4 | NA | A | A | A | A | A | NA | NA | ||
| ¬ Bolted suitable for Type 7 & 9 or Type 3R, 7, & 9. | ||||||||||||
| T Unilock suitable for Type 7 & 9 or Type 3R, 7, & 9 with the addition of a drain or a breather and drain. | ||||||||||||
A = Available, NA = Not Available, S = Standard |
||||||||||||