Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Combination Contactors, Starters, and Pump Control Panels > Bulletin 512H Horizontal Mounting Disconnect Type
Bulletin 512H Horizontal Mounting Disconnect Type
| Introduction | Standards Compliance and Certifications | Configuration of a Basic Combination Starter | Product Selection | Modifications for Combination Devices |
| Accessories | Specifications | Full Load Motor Currents | Approximate Dimensions | Renewal Parts |
The information below is for reference purposes only. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection.
Example Cat. No.
| 512 | | A | A | CD | | A2D | | 1 | | 24R | | 90 | ||
| a | b | c | d | e | f | |||||||||
| a | b | |||
| Bulletin No. | Starter Size | |||
| Bulletin No. | Description | NEMA Size Code | NEMA Size | |
| 502 | Combination contactor with disconnect switch | A | 0 | |
| 503 | Combination contactor with circuit breaker | B | 1 | |
| 506 | Reversing combination starter with disconnect switch | C | 2 | |
| 506X | Reversing combination starter with disconnect switch in a narrow enclosure | D | 3 | |
| 507 | Reversing combination starter with circuit breaker | E | 4 | |
| 507X | Reversing combination starter with circuit breaker in a narrow enclosure | F | 5 | |
| 512 | Non-reversing combination starter with disconnect switch | G | 6 | |
| 512H | Horizontal mounting combination starter with disconnect switch | H | 7 | |
| 512M | Non-reversing combination starter with disconnect switch — extra panel space | |||
| 512V | Non-reversing vacuum combination starter with disconnect switch | |||
| 513 | Non-reversing combination starter with circuit breaker | |||
| 513H | Horizontal mounting combination starter with circuit breaker | |||
| 513M | Non-reversing combination starter with circuit breaker — extra panel space | |||
| 513V | Non-reversing vacuum combination starter with circuit breaker | |||
| 522E | 2-speed, 2-winding, full voltage, multi-speed combination starter with disconnect switch | |||
| 522F | 2-speed, 1-winding, constant or variable torque, full voltage, multi-speed combination starter with disconnect switch | |||
| 522G | 2-speed, 1-winding, constant horsepower, full voltage, multi-speed combination starter with disconnect switch | |||
| 523E | 2-speed, 2-winding, full voltage, multi-speed combination starter with circuit breaker | |||
| 523F | 2-speed, 1-winding, constant or variable torque, full voltage, multi-speed combination starter with circuit breaker | |||
| 523G | 2-speed, 1-winding, constant horsepower, full voltage, multi-speed combination starter with circuit breaker | |||
| 1232X | Pump panel with disconnect switch | |||
| 1232V | Pump panel with vacuum contactor and disconnect switch | |||
| 1233X | Pump panel with circuit breaker | |||
| 1233V | Pump panel with vacuum contactor and circuit breaker | |||
| c | d | |||||
| Enclosure Type | Coil Voltage | |||||
| Code | Type | Voltage Code |
Description | Line Voltage [V] |
Coil Voltage [V] |
|
| A | Type 1: General purpose, painted metal enclosure with spring latch door fastener, external overload relay reset, and non-metallic handle | H | Common Control (without transformer) |
208 | 208 | |
| F | Type 3R/4/12: Rainproof, watertight, dusttight, painted metal enclosure with screw fasteners, external overload relay reset, and non-metallic handle | A | 240 | 240 | ||
| J | Type 3R/4/12: Rainproof, watertight, dusttight, painted metal enclosure with door safety hardware, metal handle, and NO external overload relay reset | B | 480 | 480 | ||
| D | Type 3R/4/12: Rainproof, watertight, dusttight, painted metal enclosure with door safety hardware, external overload relay reset, and metal handle | C | 600 | 600 | ||
| N | Type 3R: Rainproof, painted metal extra-capacity enclosure with screw fasteners, external overload relay reset, and a non-metallic handle | H | Transformer Control¬ |
208 | 120 | |
| C | Type 4/4X: Watertight corrosion-resistant stainless steel enclosure with screw fasteners, external overload relay reset, and a stainless steel handle | A | 240 | 120 | ||
| S | Type 4/4X: Watertight corrosion-resistant non-metallic enclosure with screw fasteners, external overload relay reset, and a non-metallic handle | B | 480 | 120 | ||
| K | Type 12: Hazardous location (Class II, Division 2, Group F + G and Class III, Divisions 1 + 2) painted metal enclosure with screw fasteners, NO external overload relay reset, and a non-metallic handle. | C | 600 | 120 | ||
| L | Type 12: Hazardous location (Class II, Division 2, Group F + G and Class III, Divisions 1 + 2) painted metal enclosure with screw fasteners, external overload relay reset, and a non-metallic handle. | HD | Separate Control (without transformer) |
208 | 120 | |
| E | Type 7+9: Hazardous location bolted enclosure, metal handle. | AD | 240 | 120 | ||
| H | Type 3R/7/9: Hazardous location bolted enclosure, rain proof, metal handle. | BD | 480 | 120 | ||
| U | Type 3R/7/9: Hazardous location Unilock enclosure, rain proof, metal handle. | CD | 600 | 120 | ||
| ¬ Note When selecting a factory-installed control circuit transformer use the Transformer Control Voltage Suffix Code to denote the transformer primary voltage. The transformer secondary voltage and starter coil will both be 120V AC by default. Example: Cat. No. 512-BAB-6P-24R will have a transformer with a 480V primary voltage, 120V secondary voltage, and a 120V starter coil voltage. |