Combination Contactors, Starters, and Pump Control Panels

Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Combination Contactors, Starters, and Pump Control Panels > Bulletin 1232 Pump Control Panels

Bulletin 1232 Pump Control Panels

Introduction Standards Compliance and Certifications Configuration of a Basic Combination Starter Product Selection Modifications for Combination Devices
Accessories Specifications Full Load Motor Currents Approximate Dimensions Renewal Parts
Product Selection

Build a Catalog Number


Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements. Located on Eutectic Alloy Overload Relay Heater Elements.
NEMA Size

Continuous Ampere Rating [A] Maximum Horsepower Rating
Full Load Current Must Not Exceed Continuous Ampere Rating
Line Voltage [V]

Fuse Clip Rating
Amperes [A]
Fuses not included.
Select per NEC ‡ 
Type 3R
Rainproof with Narrow Enclosure
AC Motor Voltage
60 Hz 60 Hz 50 Hz 60 Hz
200V 230V 380…415V 460…575V Cat. No.⋆ 
1 27 7-1/2 7-1/2 208…240 30 1232-BNÄ-µ-24
10 10 480…600 30 1232-BNÄ-µ-24
7-1/2 7-1/2 208…240 60 1232-BNÄ-µ-25
10 10 480…600 60 1232-BNÄ-µ-25
2 45 10 15 208…240 60 1232-CNÄ-µ-25
25 25 480…600 60 1232-CNÄ-µ-25
10 15 208…240 100 1232-CNÄ-µ-26
25 25 480…600 100 1232-CNÄ-µ-26
3 90 25 30 208…240 100 1232-DNÄ-µ-26
50 50 480…600 100 1232-DNÄ-µ-26
25 30 208…240 200 1232-DNÄ-µ-27
50 50 480…600 200 1232-DNÄ-µ-27
  
⋆ Class R fuse clips can be supplied as a factory option in place of Class H clips. To order Class R fuse clips, add an “R” after the cat. no. Example: Cat. No. 1232-BN⊗-✪-24 becomes Cat. No. 1232-BN⊗-✪-24R. Class H fuse clips will accept Class R fuses. However, only Class R fuse clips are the rejection type which limit their use to Class R fuses. To order Class J fuse clips, add a “J” after the cat. no. Example: Cat. No. 1232-BN⊗-✪-24 becomes Cat. No. 1232-BN⊗-✪-24J.
‡ Some applications may require time-delay fuses when this size fuse clip is used.

Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 1232-BNÄ-µ-24 becomes Cat. No. 1232-BNA-µ-24. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.


Voltage§  [V] 208 230…240 460…480 575…600
Common Control AC, 60 Hz H A B C
Transformer Control♣ 
120V Separate Control (without transformer) AD AD CD CD
  

µ Overload Relay Code

Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Three-Phase Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no.
Example: Cat. No. 1232-BNA-µ-24 becomes Cat. No. 1232-BNA-A2E-24.