Reduced Voltage Starters, Combination Starters, and Pump Control Panels

Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Contactors, Starters, and Overload Relays > Reduced Voltage Starters, Combination Starters, and Pump Control Panels > Bulletin 532 & 1282 Part Winding Combination Starters and Pump Panels

Bulletin 532 & 1282 Part Winding Combination Starters and Pump Panels

Introduction Standards Compliance and Certifications Configuration of a Basic Starter Product Selection Modifications for Combination Devices
Accessories Specifications Full Load Motor Currents Approximate Dimensions Renewal Parts
Product Selection

Heater Elements — Starters with eutectic alloy overload relays require 6 overload heater elements. Located on Eutectic Alloy Overload Relay Heater Elements.
NEMA Size Continuous Ampere Rating [A] Maximum Horsepower Rating
Full Load Current Must Not Exceed
“Continuous Ampere Rating”
Type 1
General Purpose¬ 
Type 3R/4/12
Rainproof, watertight, dusttight¬ 
Type 3R
Rainproof with extra panel space¬ 
Motor Voltage Fuse Rating [A]
200V 230V 460V 575V Cat. No. Cat. No. Cat. No.
1PW 54 15 15 30 532-LAÄ-µ-µ-24R 532-LFÄ-µ-µ-24R 1282-LNÄ-µ-µ-24R
10 10 60 532-LAÄ-µ-µ-25R 532-LFÄ-µ-µ-25R 1282-LNÄ-µ-µ-25R
2PW 90 20 30 532-MAÄ-µ-µ-24R 532-MFÄ-µ-µ-24R 1282-MNÄ-µ-µ-24R
15 30 40 60 532-MAÄ-µ-µ-25R 532-MFÄ-µ-µ-25R 1282-MNÄ-µ-µ-25R
20 25 40 100 532-MAÄ-µ-µ-26J 532-MFÄ-µ-µ-26J 1282-MNÄ-µ-µ-26J
3PW 180 50 60 100 532-PAÄ-µ-µ-26R 532-PFÄ-µ-µ-26R 1282-PNÄ-µ-µ-26R
40 50 75 75 200 532-PAÄ-µ-µ-27J 532-PFÄ-µ-µ-27J 1282-PNÄ-µ-µ-27J
4PW 270 50 100 150 200 532-SAÄ-µ-µ-27R 532-SFÄ-µ-µ-27R 1282-SNÄ-µ-µ-27R
75 75 150 400 532-SAÄ-µ-µ-28J 532-SFÄ-µ-µ-28J 1282-SNÄ-µ-µ-28J
5PW 540 100 100 200 300 400 532-UAÄ-µ-µ-28R 532-UFÄ-µ-µ-28R 1282-UNÄ-µ-µ-28R
150 150 350 350 600 532-UAÄ-µ-µ-29J 532-UFÄ-µ-µ-29J 1282-UNÄ-µ-µ-29J
  

Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example:
Cat. No. 1282-LN
Ä-µ-µ-24R becomes Cat. No. 1282-LNB-µ-µ-24R. For other voltages, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.


[V] 208 230...240 460...480 575...600
Common Control AC, 60 Hz H A B C
Transformer Control (See ¬ Note: )
120V Separate Control (without transformer) AD AD CD CD
  

µ Overload Relay Code

Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset)
to complete the cat. no. Example: Cat. No. 1282-LNB-µ-µ-24R becomes
Cat. No. 1282-LNB-A2D-A2D-24R
.


¬  Non-Fusible Disconnect Type

Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code from the cat. no. Example: Cat. No. 532-MFB-24R becomes Cat. No. 532-MFB.