Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Contactors, Starters, and Overload Relays > Reduced Voltage Starters, Combination Starters, and Pump Control Panels > Catalog Number Explanation
Catalog Number Explanation
Configuration of a Basic StarterThe information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection.
Example Catalog Number
| 530 | L | A | B | | A2D | | 1 | | 90 | |||
| a | b | c | d | e | f |
| a | |
| Bulletin Number | |
| Code | Description |
| 530 | Part winding reduced voltage starter |
| 532 | Part winding reduced voltage combination starter with disconnect switch |
| 533 | Part winding reduced voltage combination starter with circuit bBreaker |
| 540 | Wye delta reduced voltage starter |
| 542 | Wye delta reduced voltage combination starter with disconnect switch |
| 543 | Wye delta reduced voltage combination starter with circuit breaker |
| 570 | Autotransformer reduced voltage starter |
| 572 | Autotransformer reduced voltage combination starter with disconnect switch |
| 573 | Autotransformer reduced voltage combination starter with circuit breaker |
| 1242 | Wye delta reduced voltage pump panel with disconnect switch |
| 1243 | Wye delta reduced voltage pump panel with circuit breaker |
| 1272 | Autotransformer reduced voltage pump panel with disconnect switch |
| 1273 | Autotransformer reduced voltage pump panel with circuit breaker |
| 1282 | Part winding reduced voltage pump panel with disconnect switch |
| 1283 | Part winding reduced voltage pump panel with circuit breaker |
| b | |
| Starter Size | |
| Suffix Code | NEMA Size |
| C | 2 |
| D | 3 |
| E | 4 |
| F | 5 |
| G | 6 |
| L | 1YD or 1PW |
| M | 2YD or 2PW |
| P | 3YD or 3PW |
| S | 4YD or 4PW |
| U | 5YD or 5PW |
| c | |
| Enclosure Code | |
| Code | Type |
| A | Type 1: general purpose painted enclosure with screw fasteners, external overload relay reset |
| F | Type 3/4/12: rainproof, watertight, dusttight, painted metal enclosure with screw fasteners, external overload relay reset |
| N | Type 3R: rainproof, painted metal extra capacity enclosure with screw fasteners, external overload relay reset |
| d | |||
| Coil Voltage | |||
| Votlage Code | Description | Line Voltage [V] |
Coil Voltage [V] |
| H | Common Control (without a transformer) | 208 | 208 |
| A | 240 | 240 | |
| B | 480 | 480 | |
| C | 600 | 600 | |
| H | Transformer Control¬ | 208 | 120 |
| A | 240 | 120 | |
| B | 280 | 120 | |
| C | 600 | 120 | |
| HD | Separate Control (without a transformer) | 208 | 120 |
| AD | 240 | 120 | |
| BD | 480 | 120 | |
| CD | 600 | 120 | |
| e | |
| Overload Relay | |
| Code | Type |
| None | Eutectic Alloy |
| See E1 Plus Solid-State Overload Relay (Selectable Class 10, 20, or 30) (Automatic/Manual Reset) |
Solid-State |
¬ Note:When selecting a factory-installed control circuit transformer, use the transformer control coil voltage code to denote the transformer primary voltage. The transformer secondary voltage and starter coil will both be 120V AC by default. Example: Cat. No. 532-LAB-6P-24R will have a transformer with a 480V primary voltage, 120V secondary voltage, and a 120V starter coil voltage.