Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Contactors, Starters, and Overload Relays > AC Contactors and Starters > Bulletin 505 Full Voltage Reversing
Bulletin 505 Full Voltage Reversing
| Introduction | Standards Compliance and Certifications | Catalog Number Explanation | Product Selection | Typical Wiring Diagrams | Modifications for Non-Combination Devices |
| Accessories | Specifications | Full Load Motor Currents | Approximate Dimensions | Heater Element Selection | Renewal Parts |
| Build a Catalog Number |
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz with 3-Pole Overload Protection | ||||||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Open Type Without Enclosure |
Type 1 General Purpose Enclosure Surface Mounting |
Type 3R/12, Rainproof, Dusttight Industrial Use Enclosure |
Type 4/4X Watertight, Corrosion- Resistant Enclosures Stainless Steel |
Type 4X Watertight, Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester |
|||
| Motor Voltage | ||||||||||
| 200V | 230V | 50 Hz | 460…575V | |||||||
| 380…415V | Cat. No.¬ T | Cat. No.¬ | Cat. No.¬ | Cat. No.¬ | Cat. No.¬ | |||||
| 00 | 9 | 1-1/2 | 1-1/2 | 2 | 2 | 505-TOÄ-µ | 505-TAÄ-µ | — | — | — |
| 0 | 18 | 3 | 3 | 5 | 5 | 505-AOÄ-µ | 505-AAÄ-µ | 505-AJÄ-µ | 505-ACÄ-µ | 505-ASÄ-µ |
| 1 | 27 | 7-1/2 | 7-1/2 | 10 | 10 | 505-BOÄ-µ | 505-BAÄ-µ | 505-BJÄ-µ | 505-BCÄ-µ | 505-BSÄ-µ |
| 2 | 45 | 10 | 15 | 25 | 25 | 505-COÄ-µ | 505-CAÄ-µ | 505-CJÄ-µ | 505-CCÄ-µ | 505-CSÄ-µ |
| 3 | 90 | 25 | 30 | 50 | 50 | 505-DOÄ-µ | 505-DAÄ-µ | 505-DJÄ-µ | 505-DCÄ-µ | — |
| 4 | 135 | 40 | 50 | 75 | 100 | 505-EOÄ-µ | 505-EAÄ-µ | 505-EJÄ-µ | 505-ECÄ-µ | |
| 5 | 270 | 75 | 100 | 150 | 200 | 505-FOÄ-µ | 505-FAÄ-µ | 505-FJÄ-µ | 505-FCÄ-µ | |
| 6§ § | 540 | 150 | 200 | 300 | 400 | 505-GOÄ-µ | 505-GAÄ-µ | 505-GJÄ-µ | 505-GCÄ-µ | |
| 7§ | 810 | — | 300 | 600 | 600 | 505-HOÄ-µ | 505-HAÄ-µ | 505-HJÄ-µ | 505-HCÄ-µ | |
| 8§ | 1215 | — | 450 | 900 | 900 | 505-JOÄ-µ | 505-JAÄ-µ | 505-JJÄ-µ | — | |
| 9§ | 2250 | — | 800 | 1600 | 1600 | 505-KOÄ-µ | 505-KAÄ-µ | — | — | |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 505-AAÄ-µ becomes Cat. No. 505-AAD-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24Ø | 110V- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | Pª | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | A11 | — | — | — | — | U | — | B | — | — | C | |
| Transformer Controlz | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | Sª | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | Dv | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ Overload Relay Code
Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. Example: Cat. No. 505-AAD-µ becomes Cat. No. 505-AAD-A2D.
¬ Omission of Overload Relays — Bulletin 505 reversing starters are available without overload protection. Cat. nos. for all starters without overload protection will be the listed cat. no. with the No. 23 added. Example: Cat. No. 505-AOD-µ would be Cat. No. 505-AOD-23.
T Vertically Arranged — Full voltage reversing starters, sizes 0…5, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed cat. no. from 505 to 505V. Example: Cat. No. 505V-AOD-A2D with solid-state overload relay and Cat. No. 505V-AOD with eutectic alloy overload relay.
Fiberglass reinforced polyester hubs are included with each starter. Sizes 6…8 are painted enclosures.
§ Does not include line and load lugs. See Contactor Accessories for kits.
§ Price includes control circuit transformer. This applies to NEMA size 6 enclosed, only.
Ø Only available on sizes 00…5. When using 24V coils on size 4 or 5, an interposing relay may be required. See AC Coil Data values.
z When selecting a factory installed control circuit transformer (see Modifications for Non-Combination Devices), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 505-BAB-6P will have a transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 505-BABJ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
ª This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
v This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
ª This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
11This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
Heater Elements — Starters with eutectic alloy overload relay require 3 heater elements. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | ||||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Hazardous Locations | |||||
| Motor Voltage | Unilock Enclosures | Bolted Enclosures | ||||||
| 200V | 230V | 50 Hz | 460…575V | Type 3R, 7 & 9 Class I, Groups C & D Class II, Groups E, F & G — Divisions 1 & 2 — |
Type 7 & 9 Class I, Groups C & D Class II, Groups E, F & G — Divisions 1 & 2 — |
Type 3R, 7 & 9 Class I, Groups C & D Class II, Groups E, F & G — Divisions 1 & 2 — |
||
| 380…415V | Cat. No.¬ T | Cat. No.¬ | Cat. No.¬ | |||||
| 0 | 18 | 3 | 3 | 5 | 5 | 505-AUÄ-µ | 505-AEÄ-µ | 505-AHÄ-µ |
| 1 | 27 | 7-1/2 | 7-1/2 | 10 | 10 | 505-BUÄ-µ | 505-BEÄ-µ | 505-BHÄ-µ |
| 2 | 45 | 10 | 15 | 25 | 25 | — | 505-CEÄ-µ | 505-CHÄ-µ |
| 3 | 90 | 25 | 30 | 50 | 50 | — | 505-DEÄ-µ | 505-DHÄ-µ |
| 4 | 135 | 40 | 50 | 75 | 100 | — | 505-EEÄ-µ | 505-EHÄ-µ |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 505-AUÄ-µ becomes Cat. No. 505-AUD-µ. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24§ | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | Pª | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | Aª | — | — | — | — | U | — | B | — | — | C | |
| Transformer Control§ | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | SØ | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | Dz | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ Overload Relay Code
Use to order solid-state overload relay. Do not use when ordering eutectic alloy overload relay. The cat. no. as listed is incomplete. Select an overload relay code from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. Example: Cat. No. 505-AUD-µ becomes Cat. No. 505-AUD-A2D.
¬ Omission of Overload Relays — Bulletin 505 reversing starters are available without overload protection. Cat. nos. for all starters without overload protection will be the listed cat. no. with the No. 23 added. Example: Cat. No. 505-AUD-µ would be Cat. No. 505-AUD-23.
T For NEMA Type 3R application it is necessary that a drain or breather and drain be added. See Factory Modifications or Accessories.
Includes drain and cover gasket.
§ Only available on sizes 00…5. When using 24V coils on size 4 or 5, an interposing relay may be required. See values.
§ When selecting a factory-installed control circuit transformer (see Modifications for Non-Combination Devices), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 505-BUB-6P will have a transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 505-BUBJ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
Ø This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
z This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
ª This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
ª This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
Heater Elements — Starters with eutectic alloy overload relays require one heater element. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 1-Phase 2-Pole 277V AC Maximum 60 Hz With 1-Pole Eutectic Overload Protection | |||||||||||
| NEMA Size | Continuous Ampere Rating [A] | No. of Poles | Type Of Motor | Maximum Horsepower Rating (Each Motor) Full load current of each motor must not exceed Continuous Ampere Rating |
Open Type Without Enclosure |
Type 1 General Purpose Enclosure |
Type 3R/12 Rainproof, Dusttight Industrial Use Enclosure |
Type 4/4X Watertight, Corrosion- Resistant Enclosure Stainless Steel |
Hazardous Location Enclosures |
||
| Type 7 & 9 Class I, Groups C & D Class II, Groups E, F & G Division 1 & 2 |
Type 3R, 7 & 9 Class I, Groups C & D Class II, Groups E, F & G Division 1 & 2 |
||||||||||
| Motor Voltage | |||||||||||
| 115V | 230V | Cat. No.¬ T | Cat. No.¬ T | Cat. No.¬ T | Cat. No.¬ T | Cat. No.¬ T | Cat. No.¬ T | ||||
| 00 | 9 | 2 | 3 Lead Repulsion Induction | 1/3 | 1 | 505-TOÄ-101 | 505-TAÄ-101 | Use Size 0 Starter | |||
| 3 Lead Split Phase | 505-TOÄ-102 | 505-TAÄ-102 | |||||||||
| 3 | 4 Lead Repulsion Induction | 505-TOÄ-103 | 505-TAÄ-103 | ||||||||
| 4 Lead Split Phase | 505-TOÄ-104 | 505-TAÄ-104 | |||||||||
| 0 | 18 | 2 | 3 Lead Repulsion Induction | 1 | 2 | 505-AOÄ-101 | 505-AAÄ-101 | 505-AJÄ-101 | 505-ACÄ-101 | 505-AEÄ-101 | 505-AHÄ-101 |
| 3 Lead Split Phase | 505-AOÄ-102 | 505-AAÄ-102 | 505-AJÄ-102 | 505-ACÄ-102 | 505-AEÄ-102 | 505-AHÄ-102 | |||||
| 3 | 4 Lead Repulsion Induction | 505-AOÄ-103 | 505-AAÄ-103 | 505-AJÄ-103 | 505-ACÄ-103 | 505-AEÄ-103 | 505-AHÄ-103 | ||||
| 4 Lead Split Phase | 505-AOÄ-104 | 505-AAÄ-104 | 505-AJÄ-104 | 505-ACÄ-104 | 505-AEÄ-104 | 505-AHÄ-104 | |||||
| 4 | 4 Lead Split Phase (Break all lines) |
505-AOÄ-105 | 505-AAÄ-105 | 505-AJÄ-105 | 505-ACÄ-105 | — | — | ||||
| 1 | 27 | 2 | 3 Lead Repulsion Induction | 2 | 3 | 505-BOÄ-101 | 505-BAÄ-101 | 505-BJÄ-101 | 505-BCÄ-101 | 505-BEÄ-101 | 505-BHÄ-101 |
| 3 Lead Split Phase | 505-BOÄ-102 | 505-BAÄ-102 | 505-BJÄ-102 | 505-BCÄ-102 | 505-BEÄ-102 | 505-BHÄ-102 | |||||
| 3 | 4 Lead Repulsion Induction | 505-BOÄ-103 | 505-BAÄ-103 | 505-BJÄ-103 | 505-BCÄ-103 | 505-BEÄ-103 | 505-BHÄ-103 | ||||
| 4 Lead Split Phase | 505-BOÄ-104 | 505-BAÄ-104 | 505-BJÄ-104 | 505-BCÄ-104 | 505-BEÄ-104 | 505-BHÄ-104 | |||||
| 4 | 4 Lead Split Phase (Break all lines) |
505-BOÄ-105 | 505-BAÄ-105 | 505-BJÄ-105 | 505-BCÄ-105 | — | — | ||||
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 505-AAXÄ-101 becomes Cat. No. 505-AAXD-101. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24 | 110…115 | 115…120 | 200…208 | 220…230 | 230…240 | 240 | 277 | |
| Common Control§ | AC, 50 Hz | — | XS§ | — | — | XPz | — | XT | — |
| AC, 60 Hz | — | — | XDØ | XH | — | XAª | — | XF | |
| Separate Control (without transformer) |
AC, 50 Hz | — | XWS§ | — | — | XWPz | — | XWT | — |
| AC, 60 Hz | XWJ | — | XWDØ | XWH | — | XWAª | — | XWF | |
| ¬ Ordering Information — All 1-phase reversing starter orders must be accompanied with a circuit diagram of the motor. | |||||||||
| T Omission of Overload Relays — Bulletin 505 reversing starters are available without overload protection. Cat. nos. for all starters without overload protection will be the listed cat. no. with the No. 23 added. Example: Cat. No. 505-AOXD-101 would be Cat. No. 505-AOXD-23-101. | |||||||||
| Only available on sizes 00…5. When using 24V coils on size 4 or 5, an interposing relay may be required. See AC Coil Data values. | |||||||||
| § When selecting a factory-installed control circuit transformer (see Modifications for Non-Combination Devices), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 505-BAXA-6P-101 will have a transformer with a 240V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 505-BAXAJ-6P-101 will have a transformer with a 240V primary/24V secondary and a 24V starter coil. | |||||||||
| § This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal. | |||||||||
| Ø This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal. | |||||||||
| z This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal. | |||||||||
| ª This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal. | |||||||||