Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Contactors, Starters, and Overload Relays > AC Contactors and Starters > Bulletin 520 Multi-Speed
Bulletin 520 Multi-Speed
| Introduction | Standards Compliance and Certifications | Catalog Number Explanation | Product Selection | Typical Wiring Diagrams | Modifications for Non-Combination Devices |
| Accessories | Specifications | Full Load Motor Currents | Approximate Dimensions | Renewal Parts |
Product Selection
520E NEMA 2 Speed Separate Winding Starter
| Build a Catalog Number |
520F NEMA 2 Speed Con/Var Torque Starter
| Build a Catalog Number |
520G NEMA 2 Speed Constant HP Starter
| Build a Catalog Number |
2-Speed Separate Winding, 3-Pole — 3-Pole, Constant or Variable Torque
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements for each speed. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | ||||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Open Type Without Enclosure |
Type 1 General Purpose Enclosure Surface Mounting |
Type 3R/12 Rainproof, Dusttight Industrial Use Enclosure |
|||
| Motor Voltage | ||||||||
| 200V | 230V | 50 Hz | 460…575V | |||||
| 380…415V | Cat. No.¬ T | Cat. No.¬ | Cat. No.¬ | |||||
| 0 | 18 | 3 | 3 | 5 | 5 | 520E-AOÄ-µ-µ | 520E-AAÄ-µ-µ | 520E-AJÄ-µ-µ |
| 1 | 27 | 7-1/2 | 7-1/2 | 10 | 10 | 520E-BOÄ-µ-µ | 520E-BAÄ-µ-µ | 520E-BJÄ-µ-µ |
| 2 | 45 | 10 | 15 | 25 | 25 | 520E-COÄ-µ-µ | 520E-CAÄ-µ-µ | 520E-CJÄ-µ-µ |
| 3 | 90 | 25 | 30 | 50 | 50 | 520E-DOÄ-µ-µ | 520E-DAÄ-µ-µ | 520E-DJÄ-µ-µ |
| 4 | 135 | 40 | 50 | 75 | 100 | 520E-EOÄ-µ-µ | 520E-EAÄ-µ-µ | 520E-EJÄ-µ-µ |
| 5 | 270 | 75 | 100 | 150 | 200 | 520E-FOÄ-µ-µ | 520E-FAÄ-µ-µ | 520E-FJÄ-µ-µ |
| 6 | 540 | 150 | 200 | 300 | 400 | 520E-GOÄ-µ-µ | — | — |
| 7 | 810 | — | 300 | 600 | 600 | 520E-HOÄ-µ-µ | — | — |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 520E-AAÄ-µ-µ becomes Cat. No. 520E-AAD-µ-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24§ | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | Pª | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | Av | — | — | — | — | U | — | B | — | — | C | |
| Transformer Control§ | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | SØ | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | Dz | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ-µ Overload Relay Code
Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: Cat. No. 520E-BAD-µ-µ becomes Cat No. 520E-BAD-A2D-A2D.
¬ These starters are for wye connected motor windings. They may not be used with open delta connected motor windings. For starters to be used with open delta connected separate winding motors, use consequent pole starter, and furnish complete ordering information, see 2-Speed Consequent Pole, 5-Pole — 3-Pole, Constant or Variable Torque.
T Vertically Arranged — Multi-speed starters, sizes 0…5, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed cat. no. from 520E to 520VE. Example: Cat. No. 520VE-BOD-A2D-A2D.
Does not include line and load lugs, see for kits.
§ Only available on sizes 00…5. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA values on AC Coil Data.
§ When selecting a factory-installed control circuit transformer (see Modifications Modifications for Non-Combination Devices), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520E-BAB-6P will have a transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520E-BABJ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
Ø This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
z This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
ª This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
v This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
2-Speed Separate Winding, 3-Pole — 3-Pole, Constant or Variable Torque, Continued
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements for each speed. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | |||||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Type 4/4X Watertight Corrosion- Resistant Enclosures Stainless Steel |
Type 4X Watertight Corrosion- Resistant Enclosure Fiberglass-Reinforced Polyester |
Hazardous Locations | ||||
| Motor Voltage | Bolted Enclosures | ||||||||
| 200V | 230V | 50 Hz | 460… 575V |
Type 7 & 9 Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
Type 3R, 7 & 9 Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
||||
| 380… 415V |
Cat. No.¬ | Cat. No.¬ T | Cat. No.¬ | Cat. No.¬ | |||||
| 0 | 18 | 3 | 3 | 5 | 5 | 520E-ACÄ-µ-µ | 520E-ASÄ-µ-µ | 520E-AEÄ-µ-µ | 520E-AHÄ-µ-µ |
| 1 | 27 | 7-1/2 | 7-1/2 | 10 | 10 | 520E-BCÄ-µ-µ | 520E-BSÄ-µ-µ | 520E-BEÄ-µ-µ | 520E-BHÄ-µ-µ |
| 2 | 45 | 10 | 15 | 25 | 25 | 520E-CCÄ-µ-µ | 520E-CSÄ-µ-µ | 520E-CEÄ-µ-µ | 520E-CHÄ-µ-µ |
| 3 | 90 | 25 | 30 | 50 | 50 | 520E-DCÄ-µ-µ | — | 520E-DEÄ-µ-µ | 520E-DHÄ-µ-µ |
| 4 | 135 | 40 | 50 | 75 | 100 | 520E-ECÄ-µ-µ | 520E-EEÄ-µ-µ | 520E-EHÄ-µ-µ | |
| 5 | 270 | 75 | 100 | 150 | 200 | 520E-FCÄ-µ-µ | — | — | |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 520E-ACÄ-µ-µ becomes Cat. No. 520E-ACD-µ-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24§ | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | Pª | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | Av | — | — | — | — | U | — | B | — | — | C | |
| Transformer Control§ | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | SØ | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | Dz | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ-µ Overload Relay Code
Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: Cat. No. 520E-ACD-µ-µ becomes Cat No. 520-ACD-A2D-A2D.
2-Speed Separate Winding, 3-Pole — 3-Pole, Constant Horsepower
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements for each speed. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | ||||||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Open Type Without Enclosure |
Type 1 General Purpose Enclosure Surface Mounting |
Type 3R/12 Rainproof, Dusttight Industrial Use Enclosure |
Type 4/4X Watertight Corrosion- Resistant Enclosures Stainless Stee |
Type 4X Watertight Corrosion- Resistant Enclosure Fiberglass- Reinforced Polyester |
|||
| Motor Voltage | ||||||||||
| 200V | 230V | 50 Hz | 460… 575V |
|||||||
| 380… 415V |
Cat. No.¬ T | Cat. No.¬ | Cat. No.¬ | Cat. No.¬ | Cat. No.¬ | |||||
| 0 | 18 | 2 | 2 | 3 | 3 | 520E-AOÄ-µ-µ | 520E-AAÄ-µ-µ | 520E-AJÄ-µ-µ | 520E-ACÄ-µ-µ | 520E-ASÄ-µ-µ |
| 1 | 27 | 5 | 5 | 7-1/2 | 25 | 520E-BOÄ-µ-µ | 520E-BAÄ-µ-µ | 520E-BJÄ-µ-µ | 520E-BCÄ-µ-µ | 520E-BSÄ-µ-µ |
| 2 | 45 | 7-1/2 | 10 | 20 | 20 | 520E-COÄ-µ-µ | 520E-CAÄ-µ-µ | 520E-CJÄ-µ-µ | 520E-CCÄ-µ-µ | 520E-CSÄ-µ-µ |
| 3 | 90 | 20 | 25 | 40 | 40 | 520E-DOÄ-µ-µ | 520E-DAÄ-µ-µ | 520E-DJÄ-µ-µ | 520E-DCÄ-µ-µ | — |
| 4 | 135 | 30 | 40 | 60 | 75 | 520E-EOÄ-µ-µ | 520E-EAÄ-µ-µ | 520E-EJÄ-µ-µ | 520E-ECÄ-µ-µ | |
| 5 | 270 | 60 | 75 | 100 | 150 | 520E-FOÄ-µ-µ | 520E-FAÄ-µ-µ | 520E-FJÄ-µ-µ | 520E-FCÄ-µ-µ | |
| 6§ | 540 | 100 | 150 | 200 | 300 | 520E-GOÄ-µ-µ | 520E-GAÄ-µ-µ | 520E-GJÄ-µ-µ | — | |
| 7§ | 810 | — | 225 | — | 450 | 520E-HOÄ-µ-µ | 520E-HAÄ-µ-µ | 520E-HJÄ-µ-µ | ||
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 520E-AAÄ-µ-µ becomes Cat. No. 520E-AAD-µ-µ, and Cat. No. 520E-ACÄ-µ-µ becomes Cat. No. 520E-ACD-µ-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24§ | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | Pv | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | Aª | — | — | — | — | U | — | B | — | — | C | |
| Transformer ControlØ | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | Sz | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | Dª | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ-µ Overload Relay Code
Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: Cat. No. 520E-AAD-µ-µ becomes Cat. No. 520E-AAD-A2D-A2B.
2-Speed Separate Winding, 3-Pole — 3-Pole, Constant Horsepower, Continued
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements for each speed. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | |||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Hazardous Locations | ||||
| Bolted Enclosures | |||||||
| Type 7 & 9¬ Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
Type 3R, 7 & 9¬ T Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
||||||
| Motor Voltage | |||||||
| 200V | 230V | 380…415V | 460…575V | Cat. No. | Cat. No. | ||
| 0 | 18 | 2 | 2 | 3 | 3 | 520E-AEÄ-µ-µ | 520E-AHÄ-µ-µ |
| 1 | 27 | 5 | 5 | 7-1/2 | 7-1/2 | 520E-BEÄ-µ-µ | 520E-BHÄ-µ-µ |
| 2 | 45 | 7-1/2 | 10 | 20 | 20 | 520E-CEÄ-µ-µ | 520E-CHÄ-µ-µ |
| 3 | 90 | 20 | 25 | 40 | 40 | 520E-DEÄ-µ-µ | 520E-DHÄ-µ-µ |
| 4 | 135 | 30 | 40 | 60 | 75 | 520E-EEÄ-µ-µ | 520E-EHÄ-µ-µ |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 520E-AEÄ-µ-µ becomes Cat. No. 520E-AED-µ-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24 | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | Pz | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | Aª | — | — | — | — | U | — | B | — | — | C | |
| Transformer Control§ | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | S§ | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | DØ | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ-µ Overload Relay Code
Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: Cat. No. 520E-AED-µ-µ becomes Cat. No. 520E-AED-A2D-A2D.
2-Speed Consequent Pole, 5-Pole — 3-Pole, Constant or Variable Torque
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements for each speed. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | ||||||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Open Type Without Enclosure |
Type 1 General Purpose Enclosure Surface Mounting |
Type 3R/12 Rainproof, Dusttight Industrial Use Enclosure |
Type 4/4X Watertight Corrosion-Resistant Enclosures Stainless Steel |
Type 4X Watertight Corrosion-Resistant Enclosure Fiberglass-Reinforced Polyester |
|||
| Motor Voltage | ||||||||||
| 200V | 230V | 50 Hz | 460…575V | |||||||
| 380…415V | Cat. No.¬ | Cat. No. | Cat. No. | Cat. No.T | Cat. No. | |||||
| 0 | 18 | 3 | 3 | 5 | 5 | 520F-AOÄ-µ-µ | 520F-AAÄ-µ-µ | 520F-AJÄ-µ-µ | 520F-ACÄ-µ-µ | 520F-ASÄ-µ-µ |
| 1 | 27 | 7-1/2 | 7-1/2 | 10 | 10 | 520F-BOÄ-µ-µ | 520F-BAÄ-µ-µ | 520F-BJÄ-µ-µ | 520F-BCÄ-µ-µ | 520F-BSÄ-µ-µ |
| 2 | 45 | 10 | 15 | 25 | 25 | 520F-COÄ-µ-µ | 520F-CAÄ-µ-µ | 520F-CJÄ-µ-µ | 520F-CCÄ-µ-µ | 520F-CSÄ-µ-µ |
| 3 | 90 | 25 | 30 | 50 | 50 | 520F-DOÄ-µ-µ | 520F-DAÄ-µ-µ | 520F-DJÄ-µ-µ | 520F-DCÄ-µ-µ | — |
| 4 | 135 | 40 | 50 | 75 | 100 | 520F-EOÄ-µ-µ | 520F-EAÄ-µ-µ | 520F-EJÄ-µ-µ | 520F-ECÄ-µ-µ | |
| 5§ | 270 | 75 | 100 | 150 | 200 | 520F-FOÄ-µ-µ | 520F-FAÄ-µ-µ | 520F-FJÄ-µ-µ | 520F-FCÄ-µ-µ | |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 520F-AAÄ-µ-µ becomes Cat. No. 520F-AAD-µ-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24§ | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | Pv | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | Aª | — | — | — | — | U | — | B | — | — | C | |
| Transformer ControlØ | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | Sz | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | Dª | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ-µ Overload Relay Code
Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: Cat. No. 520F-AAD-µ-µ becomes Cat. No. 520F-AAD-A2D-A2D.
¬ Vertically Arranged — Multi-speed starters, sizes 0…5, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed cat. no. from 520F to 520VF. Example: Cat. No. 520VF-AOD-A2D-A2D.
T Size 6 is a painted enclosure.
Fiberglass reinforced polyester hubs are included with each starter.
§ For proper overload relay selection, when low speed full load currents are less than 77 A, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
§ Only available on sizes 0…5. When using 24V coils on sizes 4 and 5, an interposing relay may be required. See coil VA values on AC Coil Data.
Ø When selecting a factory-installed control circuit transformer (see Modifications Modifications for Non-Combination Devices), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520F-BAB-6P will have a transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520F-BABJ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
z This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
ª This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
v This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
ª This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
2-Speed Consequent Pole, 5-Pole — 3-Pole, Constant or Variable Torque, Continued
|
|
|
| Bulletin 520F, Size 1 with Eutectic Alloy Overload Relay Bolted Enclosure (with Cover Open) |
Bulletin 520F, Size 1 with Solid-State Overload Relay Bolted Enclosure (with Cover Open) |
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements for each speed. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | |||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Hazardous Locations | ||||
| Bolted Enclosures | |||||||
| Motor Voltage | Type 7 & 9 Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
Type 3R, 7 & 9¬ Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
|||||
| 200V | 230V | 50Hz | 460…575V | ||||
| 380…415V | Cat. No. | Cat. No. | |||||
| 0 | 18 | 3 | 3 | 5 | 5 | 520F-AEÄ-µ-µ | 520F-AHÄ-µ-µ |
| 1 | 27 | 7-1/2 | 7-1/2 | 10 | 10 | 520F-BEÄ-µ-µ | 520F-BHÄ-µ-µ |
| 2 | 45 | 10 | 15 | 25 | 25 | 520F-CEÄ-µ-µ | 520F-CHÄ-µ-µ |
| 3 | 90 | 25 | 30 | 50 | 50 | 520F-DEÄ-µ-µ | 520F-DHÄ-µ-µ |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 520F-AEÄ-µ-µ becomes Cat. No. 520F-AED-µ-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24 | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | P§ | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | AØ | — | — | — | — | U | — | B | — | — | C | |
| Transformer ControlT | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | S | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | D§ | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ-µ Overload Relay Code
Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: Cat. No. 520F-AED-µ-µ becomes Cat. No. 520F-AED-A2D-A2D.
¬ Includes drain and cover gasket.
T When selecting a factory-installed control circuit transformer (see Modifications Modifications for Non-Combination Devices), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520F-BEB-6P will have a transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520F-BEBJ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
§ This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
§ This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
Ø This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
2-Speed Consequent Pole, 5-Pole — 3-Pole, Constant Horsepower
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements for each speed. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | ||||||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Open Type Without Enclosure |
Type 1 General Purpose Enclosure Surface Mounting |
Type 3R/12 Rainproof, Dusttight Industrial Use Enclosure |
Type 4/4X Watertight Corrosion-Resistant Enclosures Stainless Steel |
Type 4X Watertight Corrosion-Resistant Enclosure Fiberglass-Reinforced Polyester |
|||
| Motor Voltage | ||||||||||
| 200V | 230V | 50 Hz | 460…575V | |||||||
| 380…415V | Cat. No.¬ | Cat. No. | Cat. No. | Cat. No.T | Cat. No. | |||||
| 0 | 18 | 2 | 2 | 3 | 3 | 520G-AOÄ-µ-µ | 520G-AAÄ-µ-µ | 520G-AJÄ-µ-µ | 520G-ACÄ-µ-µ | 520G-ASÄ-µ-µ |
| 1 | 27 | 5 | 5 | 7-1/2 | 7-1/2 | 520G-BOÄ-µ-µ | 520G-BAÄ-µ-µ | 520G-BJÄ-µ-µ | 520G-BCÄ-µ-µ | 520G-BSÄ-µ-µ |
| 2 | 45 | 7-1/2 | 10 | 20 | 20 | 520G-COÄ-µ-µ | 520G-CAÄ-µ-µ | 520G-CJÄ-µ-µ | 520G-CCÄ-µ-µ | 520G-CSÄ-µ-µ |
| 3 | 90 | 20 | 25 | 40 | 40 | 520G-DOÄ-µ-µ | 520G-DAÄ-µ-µ | 520G-DJÄ-µ-µ | 520G-DCÄ-µ-µ | — |
| 4 | 135 | 30 | 40 | 60 | 75 | 520G-EOÄ-µ-µ | 520G-EAÄ-µ-µ | 520G-EJÄ-µ-µ | 520G-ECÄ-µ-µ | |
| 5 | 270 | 60 | 75 | 100 | 150 | 520G-FOÄ-µ-µ | 520G-FAÄ-µ-µ | 520G-FJÄ-µ-µ | 520G-FCÄ-µ-µ | |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 520G-AAÄ-µ-µ becomes Cat. No. 520G-AAD-µ-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24§ | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | Pª | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | Av | — | — | — | — | U | — | B | — | — | C | |
| Transformer Control§ | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | SØ | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | Dz | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ-µ Overload Relay Code
Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: Cat. No. 520G-AAD-µ-µ becomes Cat. No. 520G-AAD-A2D-A2D.
¬ Vertically Arranged — Multi-speed starters, sizes 0…5, open type without enclosure can be supplied in a vertically arranged construction. To order, change the bulletin number in the listed cat. no. from 520G to 520VG. Example: Cat. No. 520VG-AOD-A2D-A2D.
T Size 6 is a painted enclosure.
Fiberglass reinforced polyester hubs are included with each starter.
§ Only available in sizes 0…5. When using 24V coils on sizes 4 and 5, an interposing relay may be required. See coil VA values on AC Coil Data.
§ When selecting a factory-installed control circuit transformer (see Modifications Modifications for Non-Combination Devices), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520G-BAB-6P will have a transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520G-BABJ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
Ø This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
z This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
ª This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
v This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.
2-Speed Consequent Pole, 5-Pole — 3-Pole, Constant Horsepower, Continued
|
|
|
| Bulletin 520G, Size 1 with Eutectic Alloy Overload Relay Bolted Enclosure (with Cover Open) |
Bulletin 520G, Size 1 with Solid-State Overload Relay Bolted Enclosure (with Cover Open) |
Heater Elements — Starters with eutectic alloy overload relays require 3 heater elements for each speed. See Eutectic Alloy Overload Relay Heater Elements for heater element selection tables.
| 3-Phase 600V AC Maximum 60 Hz With 3-Pole Overload Protection | |||||||
| NEMA Size | Continuous Ampere Rating [A] | Maximum Horsepower Rating Full Load Current Must Not Exceed Continuous Ampere Rating |
Hazardous Locations | ||||
| Bolted Enclosures | |||||||
| Motor Voltage | Type 7 & 9 Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
Type 3R, 7 & 9¬ Class I, Groups C & D Class II, Groups E, F & G Divisions 1 & 2 |
|||||
| 200V | 230V | 380...415V | 460…575V | Cat. No. | Cat. No. | ||
| 0 | 18 | 3 | 3 | 5 | 5 | 520G-AEÄ-µ-µ | 520G-AHÄ-µ-µ |
| 1 | 27 | 7-1/2 | 7-1/2 | 10 | 10 | 520G-BEÄ-µ-µ | 520G-BHÄ-µ-µ |
| 2 | 45 | 10 | 15 | 25 | 25 | 520G-CEÄ-µ-µ | 520G-CHÄ-µ-µ |
| 3 | 90 | 25 | 30 | 50 | 50 | 520G-DEÄ-µ-µ | 520G-DHÄ-µ-µ |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 520G-AEÄ-µ-µ becomes Cat. No. 520G-AED-µ-µ. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.
| [V] | 24 | 110- 115 |
115- 120 |
200- 208 |
220- 230 |
230- 240 |
240 | 277 | 380 | 380- 400 |
415 | 440- 460 |
460- 480 |
500 | 550 | 575- 600 |
|
| Common Control | AC, 50 Hz |
— | — | — | — | P§ | — | T | — | N | KN | I | Q | — | M | R | — |
| AC, 60 Hz |
— | — | — | H | — | AØ | — | — | — | — | U | — | B | — | — | C | |
| Transformer ControlT | AC, 60 Hz |
— | — | — | H | — | A | — | — | — | — | — | — | B | — | — | C |
| Separate Control (without transformer) |
AC, 50 Hz |
K | S | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| AC, 60 Hz |
J | — | D§ | — | — | — | — | F | — | — | — | — | — | — | — | — | |
µ-µ Overload Relay Code
Use to order solid-state overload relays. Do not use when ordering eutectic alloy overload relays. The cat. no. as listed is incomplete. Select two overload relay codes from E1 Plus Solid-State Overload Relay
(Selectable Class 10, 20, or 30) (Automatic/Manual Reset) to complete the cat. no. The first code will denote the high-speed overload relay and the second code will denote the low-speed overload relay. Example: Cat. No. 520G-AED-µ-µ becomes Cat. No. 520G-AED-A2D-A2D.
¬ Includes drain and cover gasket.
T When selecting a factory-installed control circuit transformer (see Modifications Modifications for Non-Combination Devices), use the common control coil voltage code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 520G-BEB-6P will have a transformer with a 480V primary/120V secondary voltage and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second coil voltage code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 520G-BEBJ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
§ This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
§ This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
Ø This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.