Cable-Operated Disconnect Switches
| Introduction | Standards Compliance and Certifications | Catalog Number Explanation | Product Selection | Accessories | Specifications | Approximate Dimensions |
Fusible and Non-Fusible Disconnect Switch Kits
- Non-fusible disconnect switch kit includes: switch and non-metallic handle (cable mechanism code must be added to complete the kit).
- Fusible disconnect switch kit includes: switch, non-metallic handle, trailer fuse block, and fuse clips (cable mechanism code must be added to complete the kit).
- Optional kit accessories listed on the following pages can be added to the disconnect switch kits to create (1) cat. no.
Example: Cat. No. 1494C-DR233-A3-F.
| Complete Disconnect Switch Kits for Type 1, 3R, 4, and 12 Metal Enclosures | |||||||||||||||||||||
| Cont. Current Rating [A] 600V AC 250V DC |
UL and CSA Applications Maximum HP |
AC 1-Phase | DCT | IEC Applications Maximum kW (AC23) |
Fuse Clip Rating [A] |
Fuse Class | Switch with Right-Hand Mechanism |
Switch with Left-Hand Mechanism |
|||||||||||||
| 3-Phase, 60 Hz | 3-Phase, 50 Hz | Fusible Disconnect Switch Kit |
Non-Fusible Disconnect Switch Kit |
Fusible Disconnect Switch Kit |
Non-Fusible Disconnect Switch Kit |
||||||||||||||||
| 115V | 200… 208V |
230V | 460V | 575V | 115V | 230V | 125V | 250V | 220… 240V |
380… 440V |
500… 600V |
250V | 600V | Cat. No.¬ | Cat. No.¬ | Cat. No.¬ | Cat. No.¬ | ||||
| 30 | 3 | 7.5 | 7.5 | 15 | 20 | 2 | 3 | 3 | 5 | 5.5 | 11 | 15 | 30 | — | H | | 1494C-DH233 | 1494C-DN30 | | 1494C-DHX233 | 1494C-DNX30 |
| 30 | — | R | 1494C-DR233 | 1494C-DRX233 | |||||||||||||||||
| 30 | — | J | 1494C-DJ233 | 1494C-DJX233 | |||||||||||||||||
| — | 30 | H | | 1494C-DH633 | | 1494C-DHX633 | |||||||||||||||
| — | 30 | R | 1494C-DR633 | 1494C-DRX633 | |||||||||||||||||
| — | 30 | J | 1494C-DJ633 | 1494C-DJX633 | |||||||||||||||||
| 60 | — | H | | 1494C-DH236 | | 1494C-DHX236 | |||||||||||||||
| 60 | — | R | 1494C-DR236 | 1494C-DRX236 | |||||||||||||||||
| 60 | — | J | 1494C-DJ236 | 1494C-DJX236 | |||||||||||||||||
| — | 60 | H | | 1494C-DH636 | | 1494C-DHX636 | |||||||||||||||
| — | 60 | R | 1494C-DR636 | 1494C-DRX636 | |||||||||||||||||
| — | 60 | J | 1494C-DJ636 | 1494C-DJX636 | |||||||||||||||||
| 60 | 7.5 | 15 | 15 | 30 | 50 | 3 | 10 | 5 | 10 | 11 | 22 | 37 | 30 | — | H | | 1494C-DH263 | 1494C-DN60 | | 1494C-DHX263 | 1494C-DNX60 |
| 30 | — | R | 1494C-DR263 | 1494C-DRX263 | |||||||||||||||||
| 30 | — | J | 1494C-DJ263 | 1494C-DJX263 | |||||||||||||||||
| — | 30 | H | | 1494C-DH663 | | 1494C-DHX663 | |||||||||||||||
| — | 30 | R | 1494C-DR663 | 1494C-DRX663 | |||||||||||||||||
| — | 30 | J | 1494C-DJ663 | 1494C-DJX663 | |||||||||||||||||
| 60 | — | H | | 1494C-DH266 | | 1494C-DHX266 | |||||||||||||||
| 60 | — | R | 1494C-DR266 | 1494C-DRX266 | |||||||||||||||||
| 60 | — | J | 1494C-DJ266 | 1494C-DJX266 | |||||||||||||||||
| — | 60 | H | | 1494C-DH666 | | 1494C-DHX666 | |||||||||||||||
| — | 60 | R | 1494C-DR666 | 1494C-DRX666 | |||||||||||||||||
| — | 60 | J | 1494C-DJ666 | 1494C-DJX666 | |||||||||||||||||
| 100 | 100 | H | | 1494C-DH661 | | 1494C-DHX661 | |||||||||||||||
| 100 | 100 | R | 1494C-DR661 | 1494C-DRX661 | |||||||||||||||||
| 100 | 100 | J | 1494C-DJ661 | 1494C-DJX661 | |||||||||||||||||
| 100 | — | 25 | 30 | 60 | 75 | — | — | — | 20 | 22 | 45 | 55 | 60 | — | H | | 1494C-DH216 | 1494C-DN100 | | 1494C-DHX216 | 1494C-DNX100 |
| 60 | — | R | 1494C-DR216 | 1494C-DRX216 | |||||||||||||||||
| 60 | — | J | 1494C-DJ216 | 1494C-DJX216 | |||||||||||||||||
| — | 60 | H | | 1494C-DH616 | | 1494C-DHX616 | |||||||||||||||
| — | 60 | R | 1494C-DR616 | 1494C-DRX616 | |||||||||||||||||
| — | 60 | J | 1494C-DJ616 | 1494C-DJX616 | |||||||||||||||||
| 100 | — | H | | 1494C-DH211 | | 1494C-DHX211 | |||||||||||||||
| 100 | — | R | 1494C-DR211 | 1494C-DRX211 | |||||||||||||||||
| 100 | — | J | 1494C-DJ211 | 1494C-DJX211 | |||||||||||||||||
| — | 100 | H | | 1494C-DH611 | | 1494C-DHX611 | |||||||||||||||
| — | 100 | R | 1494C-DR611 | 1494C-DRX611 | |||||||||||||||||
| — | 100 | J | 1494C-DJ611 | 1494C-DJX611 | |||||||||||||||||
| — | 200 | J | 1494C-DJ612 | 1494C-DJX612 | |||||||||||||||||
| 200 | — | 50…60 | 60 | 125 | 150 | — | — | — | 40 | 48 | 90 | 110 | 100 | — | H | | 1494C-DH221 | 1494C-DN200 | | 1494C-DHX221 | 1494C-DNX200 |
| 100 | — | R | 1494C-DR221 | 1494C-DRX221 | |||||||||||||||||
| 100 | — | J | 1494C-DJ221 | 1494C-DJX221 | |||||||||||||||||
| — | 100 | H | | 1494C-DH621 | | 1494C-DHX621 | |||||||||||||||
| — | 100 | R | 1494C-DR621 | 1494C-DRX621 | |||||||||||||||||
| — | 100 | J | 1494C-DJ621 | 1494C-DJX621 | |||||||||||||||||
| 200 | — | H | | 1494C-DH222 | | 1494C-DHX222 | |||||||||||||||
| 200 | — | R | 1494C-DR222 | 1494C-DRX222 | |||||||||||||||||
| 200 | — | J | 1494C-DJ222 | 1494C-DJX222 | |||||||||||||||||
| — | 200 | H | | 1494C-DH622 | | 1494C-DHX622 | |||||||||||||||
| — | 200 | R | 1494C-DR622 | 1494C-DRX622 | |||||||||||||||||
| — | 200 | J | 1494C-DJ622 | 1494C-DJX622 | |||||||||||||||||
| — | 400 | J | 1494C-DJ624 | 1494C-DJX624 | |||||||||||||||||
| 400 | — | 75 | 125 | 250 | 300 | — | — | — | 50 | 90 | 185 | 259 | 200 | — | H | | 1494C-DH242 | 1494C-DN400 | | 1494C-DHX242 | 1494C-DNX400 |
| 200 | — | R | 1494C-DR242 | 1494C-DRX242 | |||||||||||||||||
| 200 | — | J | 1494C-DJ242 | 1494C-DJX242 | |||||||||||||||||
| — | 200 | H | | 1494C-DH642 | | 1494C-DHX642 | |||||||||||||||
| — | 200 | R | 1494C-DR642 | 1494C-DRX642 | |||||||||||||||||
| — | 200 | J | 1494C-DJ642 | 1494C-DJX642 | |||||||||||||||||
| 400 | — | H | | 1494C-DH244 | | 1494C-DHX244 | |||||||||||||||
| 400 | — | R | 1494C-DR244 | 1494C-DRX244 | |||||||||||||||||
| 400 | — | J | 1494C-DJ244 | 1494C-DJX244 | |||||||||||||||||
| — | 400 | H | | 1494C-DH644 | | 1494C-DHX644 | |||||||||||||||
| — | 400 | R | 1494C-DR644 | 1494C-DRX644 | |||||||||||||||||
| — | 400 | J | 1494C-DJ644 | 1494C-DJX644 | |||||||||||||||||
| 600 | — | 150 | 200 | 400 | 500 | — | — | — | 50 | 150 | 295 | 375 | 400 | — | H | | 1494C-DH204 | 1494C-DN600 | | 1494C-DHX204 | 1494C-DNX600 |
| 400 | — | R | 1494C-DR204 | 1494C-DRX204 | |||||||||||||||||
| 400 | — | J | 1494C-DJ204 | 1494C-DJX204 | |||||||||||||||||
| — | 400 | H | | 1494C-DH604 | | 1494C-DHX604 | |||||||||||||||
| — | 400 | R | 1494C-DR604 | 1494C-DRX604 | |||||||||||||||||
| — | 400 | J | 1494C-DJ604 | 1494C-DJX604 | |||||||||||||||||
| 600 | — | H | | 1494C-DH206 | | 1494C-DHX206 | |||||||||||||||
| 600 | — | R | 1494C-DR206 | 1494C-DRX206 | |||||||||||||||||
| 600 | — | J | 1494C-DJ206 | 1494C-DJX206 | |||||||||||||||||
| — | 600 | H | | 1494C-DH606 | | 1494C-DHX606 | |||||||||||||||
| — | 600 | R | 1494C-DR606 | 1494C-DRX606 | |||||||||||||||||
| — | 600 | J | 1494C-DJ606 | 1494C-DJX606 | |||||||||||||||||
| ¬ The catalog number is incomplete until you select the cable mechanism code from the table below. | |||||||||||||||||||||
| T Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC line. | |||||||||||||||||||||
| Class J fuses can be installed on Class H fuse clips. However, when selecting a fuse cover (option code E), select the proper clip (Class H, J, or R) in order to receive the correct size fuse cover. Example: Cat. No. 1494C-DH233-E becomes Cat. No. 1494C-DJ233-E or Cat. No. 1494C-DR233-E. | |||||||||||||||||||||
Cable Mechanism Code
Select the desired cable length to complete the catalog number. Example: 1494C-DH633 with a 4 foot cable = 1494C-DH633-A4
| Bulletin 1494C Cable Mechanism Code | ||
| Description | Suffix Code | |
| 3 ft cable | § | A3 |
| 4 ft cable | A4 | |
| 5 ft cable | A5 | |
| 6 ft cable | § | A6 |
| 10 ft cable | A10 | |
| § Only available with 30…100 A switches. | ||
| § Only available with 200…600 A switches. | ||
Kit Accessories
Example: 1494C-DH233-A4-D-E Basic 30A fusible disconnect switch with 4 foot cable, non-metallic handle, line and load lugs, fuse cover
| Bulletin 1494V Kit Accessories — Field Installed | |||||||||
| Description | Suffix Code | Switch Size | |||||||
| 30 A | 60 A | 100 A | 200 A | 400 A | 600 A | ||||
| Longer connecting rod (9-1/2…23 in.) | A | A | A | A | A | A | A | ||
| Disconnect handle — Stainless steel | Ø | B | A | A | A | A | A | A | |
| Disconnect handle — Metal | Ø | B1 | A | A | A | A | — | — | |
| Standard size wire connecting lugs — Line and load side | D | Included | A | A | A | A | A | ||
| Oversize wire connecting lugs — Line and load side | D1 | — | — | — | A | A | — | ||
| Protective fuse cover with door | z | E | A | A | A | A | A | A | |
| Auxiliary contact | 1 N.O. | F | A | A | A | A | A | A | |
| 2 N.O. | FF | A | A | A | A | A | A | ||
| 1 N.C. | G | A | A | A | A | A | A | ||
| 2 N.C. | GG | A | A | A | A | A | A | ||
| Electrical interlock (Early break) |
1 N.O. & 1 N.C. | H | A | A | A | A | A | A | |
| 2 N.O. & 2 N.C. | HH | A | A | A | A | A | A | ||
| Ø Non-metallic handle provided as standard on the 30…200 A switches (non-metallic handles are not available for the 400…600 A switches). The painted metal handle is provided as standard on the 400…600 A switches. For stainless steel handle, select suffix code B. For metal handle, select suffix code B1. | |||||||||
| z Select the proper fuse clip (Class J, H, or R) in order to receive the correct size fuse cover. Example: Cat. Nos. 1494V-DH233-E, 1494V-DJ233-E, or 1494V-DR233-E. |
|||||||||
Disconnect Switches
| Cont. Current Rating¬ [A] 600V AC 250V DC |
NEMA, UL, CSA Maximum Rating Hp |
AC 1-Phase | DCT | IEC Utilization Category AC-23 Maximum Rating kW |
Switch for Right-Hand Mechanism |
Switch for Left-Hand Mechanism |
|||||||
| 3-Phase, 60 Hz | 3-Phase, 50 Hz | ||||||||||||
| 200…208V | 230V | 460V | 575V | 115 | 230 | 250 | 220…240V | 380…440V | 500…600V | Cat. No. Switch Only |
Cat. No. Switch Only |
||
| 30 | 7.5 | 7.5 | 15 | 20 | 2 | 3 | 5 | 5.5 | 11 | 15 | 1494F-D30 | 1494F-DX30 | |
| 60 | 15 | 15 | 30 | 50 | 3 | 10 | 10 | 11 | 22 | 37 | 1494F-D60 | 1494F-DX60 | |
| 100 | 25 | 30 | 60 | 75 | — | — | 20 | 22 | 45 | 55 | 1494F-D100 | 1494F-DX100 | |
| 200 | 50…60 | 60 | 125 | 150 | — | — | 40 | 48 | 90 | 110 | 1494F-D200 | 1494F-DX200 | |
| 400 | 75 | 125 | 250 | 350 | — | — | 50 | 90 | 185 | 257 | 1494F-D400 | 1494F-DX400 | |
| 600 | 150 | 200 | 400 | 500 | — | — | 50 | 150 | 295 | 375 | 1494V-DS600 | | 1494V-DS600 |
| ¬ Also rated operational current for utilization categories AC-20 and AC-21 (IEC 408). | |||||||||||||
| T Ratings based on utilizing two poles in series to break one line of the DC supply voltage and the remaining pole breaking the second DC supply line. | |||||||||||||
| Switch can be converted in the field for left-hand operation. | |||||||||||||
Cable Mechanisms
| Disconnect Switch Size [A] | Cable Length [ft] | Right-Hand Cable Mechanisms | Left-Hand Cable Mechanisms |
| Cat. No. | Cat. No. | ||
| 30, 60, 100 | 3 | 1494C-CM1 | 1494C-CMX1 |
| 4 | 1494C-CM2 | 1494C-CMX2 | |
| 5 | 1494C-CM3 | 1494C-CMX3 | |
| 10 | 1494C-CM4 | 1494C-CMX4 | |
| 200 | 4 | 1494C-CM5 | 1494C-CMX5 |
| 5 | 1494C-CM6 | 1494C-CMX6 | |
| 6 | 1494C-CM7 | 1494C-CMX7 | |
| 10 | 1494C-CM8 | 1494C-CMX8 | |
| 400 | 4 | 1494C-CM9 | 1494C-CMX9 |
| 5 | 1494C-CM10 | 1494C-CMX10 | |
| 6 | 1494C-CM11 | 1494C-CMX11 | |
| 10 | 1494C-CM12 | 1494C-CMX12 | |
| 600 | 4 | 1494C-CM13 | 1494C-CMX13 |
| 5 | 1494C-CM14 | 1494C-CMX14 | |
| 6 | 1494C-CM15 | 1494C-CMX15 | |
| 10 | 1494C-CM16 | 1494C-CMX16 | |
Operating Handles
| Handle Type |
Description | Mounting | Disconnect Switch Size [A] |
Cat. No. |
| Type 1, 3R, 4, 4X, 12 | Nonmetallic | Right or Left Flange | 30, 60, 100, 200 | 1494F-P1 |
| Type 1, 3R, 4, 12 | Painted Metal | Right or Left Flange | 30, 60, 100, 200 | 1494F-M1 |
| 400, 600 | 1494F-M2 | |||
| Type 4, 4X | Stainless Steel | Right or Left Flange | 30, 60, 100, 200 | 1494F-S1 |
| 400, 600 | 1494F-S2 | |||
Trailer Fuse Block Kits
For Class H, J, or R fuses, select the proper fuse clip kit from the table below.
| Disconnect Switch Size [A] | Cat. No. | |
| 30 | 1494V-FS30 | |
| 60 | 1494V-FS60 | |
| 100 | 1494V-FS100 | |
| 200 | v | 1494V-FS200 |
| 400 | 1494V-FS400 | |
| 600 — 600 A Class J fuse | 1494-FS600 | |
| 600 — 400 A Class H, J, and R fuse | 1494V-FSV400 | |
| 600 — 600 A Class H fuse | ª | 1491-N621 |
| 600 — 600 A Class R fuse | ª | 1491-R621 |
| v When installing 400 A Class J fuses, use adapter kit (Cat. No. 1401-N171). Fuse clips not required. | ||
| ª Separately mounted fuse blocks (3 required). | ||
Fuse Clip Kits
- Includes six clips and mounting hardware
| Fuse Class | Fuse Clip Rating [A] | For Use With | Cat. No. | |
| 250V | 600V | |||
| H, J | 30 | — | 1494C, 1494F, 1494G, 1494M, 1494V Disconnect Switches |
1401-N41 |
| 60 | 30 | 1401-N42 | ||
| — | 60 | 1401-N43 | ||
| 100 | 100 | 1401-N44 | ||
| 200 | 200 | 1401-N45 | ||
| 400 | 400 | 1401-N46 | ||
| 600 | 600 | Ø | ||
| J | 30 | 30 | 1401-N42 | |
| 60 | 60 | 1401-N43 | ||
| 100 | 100 | 1401-N44 | ||
| 200 | 200 | 1401-N45 | ||
| 400 | 400 | 1401-N46 | ||
| 600 | 600 | ª | ||
| R | 30 | — | 1401-N50 | |
| 60 | 30 | 1401-N51 | ||
| — | 60 | 1401-N52 | ||
| 100 | 100 | 1401-N53 | ||
| 200 | 200 | 1401-N54 | ||
| 400 | 400 | 1401-N55 | ||
| 600 | 600 | Ø | ||
| ª Fuse clips not required: fuse bolts directly to terminal. | ||||
| Ø Included with Bulletin 1491 separately mounted fuse blocks. | ||||