Description
|
For Use With
|
Cat. No.
|
| Auxiliary Contacts
|
1 N.O. Contact
|
1494C, 1494F, 1494V, and 1494G (30…400 A) Disconnect Switches
1494D, 1494V★ (125…400 A Frame) Circuit Breakers
|
1495-N8
|
| 1 N.O. Contact (low-level switching)
|
1495-N8X
|
| 1 N.C. Contact
|
1495-N9
|
| 1 N.C. Contact (low-level switching)
|
1495-N9X
|
|
|
Auxiliary Contacts (600 A Disconnect Switch only)
|
1 N.O. Contact
|
1494C, 1494G, and 1494V Disconnect Switches 600 A only
|
595-A
|
| Cat. No. 595-A
|
Cat. No. 595-B
|
1 N.C. Contact
|
595-B
|
|
Auxiliary Contact Adapter Kit For Disconnect Switches
|
600 A
|
|
595-N1
|
| Cat. No. 595-N1
|
|
Auxiliary Contact Adapter Kit For Disconnect Switches with Left-Hand Mechanism
|
30…100 A Disconnect Switch
|
1494V Disconnect Switch with Left-Hand Mechanism, 30…100 A
|
|
1495-N24
|
| Cat. No. 1495-N24
|
200…400 A Disconnect Switch
|
1494V Disconnect Switch with Left-Hand Mechanism, 200…400 A
|
|
1495-N25
|
|
|
Auxiliary Contact Adapter Kit For Circuit Breakers
|
125 A and 150 A Frame Allen‑Bradley, Cutler-Hammer
|
1494D, 1494V Circuit Breakers
|
|
1495-N21
|
| 250 A, 400 A Frame Allen‑Bradley, Cutler-Hammer
|
1494V Circuit Breaker
|
|
1495-N23
|
| 250 A Frame Allen-Bradley, Cutler-Hammer
|
1494D Circuit Breaker
|
|
1495-N22
|
| 400 A Frame Allen-Bradley, Cutler-Hammer
|
1494D Circuit Breaker
|
|
1495-N16
|
Cat. No. 1495-N21
|
Cat. No. 1495-N23
|
600 A, 800 A, 1200 A Frame Cutler-Hammer
|
1494D Circuit Breaker
|
|
1495-N13
|
|
|
Auxiliary Contacts
|
1 N.O. Contact
|
1494R Disconnect Switch 30 A, 60 A
|
895-A1
|
| 1 N.C. Contact
|
895-B1
|
| 1 N.O. and 1 N.C. Contact
|
895-C1
|
| Auxiliary Contact Adapter Kit for 1 contact
|
895-M11
|
| Cat. No. 895-A1
|
Cat. No. 895-M11
|
Auxiliary Contact Adapter Kit for 2 contacts
|
895-M12
|
|
|
Auxiliary Contacts
|
1 N.O. Contact
|
1494R Disconnect Switch 100 A, 200 A
|
895-A2
|
| 1 N.C. Contact
|
895-B2
|
| 1 N.O. and 1 N.C. Contact
|
895-C2
|
| Auxiliary Contact Adapter Kit for 1 contact
|
895-M21
|
| Cat. No. 895-A2
|
Cat. No. 895-M21
|
Auxiliary Contact Adapter Kit for 2 contacts
|
895-M22
|
|
Electrical Interlocks
|
1 N.O. and 1 N.C. — early make/break
|
1494C, 1494G & 1494V Disconnect Switches with Left-/Right-Hand Mechanism, 30…100 A & Right-Hand Mechanism, 600 A
|
§
|
1495-N34
|
| 2 N.O. and 2 N.C. — early make/break
|
§
|
1495-N35
|
| 1 N.O. and 1 N.C. — early make/break
|
1494C, 1494G, & 1494V Disconnect Switch with Right-Hand Mechanism, 200 A, 400 A
|
1495-N43
|
| 2 N.O. and 2 N.C. — early make/break
|
1495-N44
|
| 1 N.O. and 1 N.C. — early make/break
|
1494C and 1494V Disconnect Switch with Left-Hand Mechanism, 30…100 A
|
1495-N37
|
| Cat. No. 1495-N34
|
2 N.O. and 2 N.C. — early make/break
|
1495-N38
|
|
1 N.O. and 1 N.C. — early make/break
|
1494V Disconnect Switch with Left-Hand Mechanism, 200 A
|
1495-N39
|
| 2 N.O. and 2 N.C. — early make/break
|
1495-N40
|
| 1 N.O. and 1 N.C. — early make/break
|
1494V Disconnect Switch with Left-Hand Mechanism, 400 A
|
1495-N41
|
| 2 N.O. and 2 N.C. — early make/break
|
1495-N42
|
| 10 A DPDT early break (for 30 A, Type 1 & 3R only)
|
1494H Safety Switch
|
1495-N77
|
15 A DPDT early break (for 30 A, Type 12) 15 A DPDT early break (for all 60 A, 100 A, & 200 A, Type 1, 3R, and 12)
|
1495-N78
|
| Cat. No. 1495-N35
|
Electrical Interlock Adapter Kit
|
600 A Disconnect Switch
|
1494C, 1494G, 1494V Disconnect Switch
|
1495-N36
|
|
|
| ★ Requires an adapter kit on new installations.
|
One adapter kit enables up to two auxiliary contacts to be installed.
|
| § Additional adapter kit (Cat. No. 1495-N36) required for installation on 600 A switch.
|
|
Description
|
For Use With
|
Cat. No.
|
| Lug Connectors (3 per package)
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
|
| Disconnect Size [A]
|
Wire Size
|
| 30
|
#14…8 AWG Wire
|
★
|
| 60
|
#14…4 AWG Wire
|
♣
|
1494R-N1
|
| 100
|
#8…1/0 AWG Wire
|
♣
|
1494R-N2
|
| 200
|
#6…4/0 AWG Wire
|
♣
|
1494R-N3
|
| #6…250 MCM Wire (oversized)
|
♣
|
199-LF1
|
| 400
|
#6…250 MCM AWG 16 mm2…120 mm2
|
♣
|
1494R-N14
|
| #4 AWG…500 MCM Wire (oversized)
|
♣
|
1494R-N15
|
| 600
|
(2) of #1/0…350 MCM Wire
|
♣
|
1494R-N10
|
| (2) of #1/0…350 MCM Wire
|
1491-N621 or 1491-R621 600 A fuse blocks
|
∆
|
1494R-N11
|
| Cat. No. 1494R-N3
|
(1) of #4…500 MCM Wire
|
∆
|
1494R-N12
|
|
Ground Connectors
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
599-GR1
|
| Ground Lug Kits
|
30…100 A
|
| 200…400 A
|
599-GR2
|
| 600 A
|
599-GR3
|
| 30, 60 A
|
1494H & 1494HL Safety Switches
|
599-GR4
|
| Cat. No. 599-GR1
|
100, 200 A
|
599-GR5
|
|
Neutral Kits 30 A @ 250/600V AC Fusible (Type 1 & 3R)
|
1494H Safety Switches
|
599-NK1
|
| 30 A @ 250/600V AC Non-Fusible (Type 1 & 3R)
|
599-NK2
|
| 30 A @ 250/600V AC Fusible & Non-Fusible (Type 12)
|
599-NK3
|
| 60 A @ 250/600V AC Fusible & Non-Fusible (Type 1 & 3R)
|
599-NK4
|
| 60 A @ 250/600V AC Fusible (Type 12)
|
599-NK5
|
| 60 A @ 250/600V AC Non-Fusible (Type 12)
|
599-NK6
|
| 100 A @ 250/600V AC Fusible (Type 1 & 3R)
|
599-NK7
|
| 100 A @ 250/600V AC Non-Fusible (Type 1, 3R, and 12)
|
599-NK8
|
| 100 A @ 250/600V AC Fusible (Type 12)
|
599-NK9
|
| 200 A @ 250/600V AC Fusible & Non-Fusible (Type 1 & 3R)
|
599-NK10
|
| 200 A @ 250/600V AC Fusible & Non-Fusible (Type 12)
|
599-NK11
|
|
|
Phase Barrier Kits
|
1494C, 1494F, 1494G, 1494V
|
|
| Disconnect Size [A]
|
| 30, 60
|
1494F-PH2
|
| 100
|
1494F-PH3
|
| 200
|
1494F-PH4
|
| 400
|
1494F-PH5
|
|
|
| ★ All terminals of the 30 A switches are furnished with self-lifting pressure plate connectors as standard.
|
| ∆ Each kits contains (2) lugs.
|
| ♣ Each kit contains (3) lugs.
|
|
Description
|
For Use With
|
Cat. No.
|
| Fuse Clips (6 per package)
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
|
| Fuse Class
|
Fuse Clip Rating [A]
|
| 250V
|
600V
|
| H
|
30
|
—
|
1401-N41
|
| 60
|
30
|
1401-N42
|
| —
|
60
|
1401-N43
|
| 100
|
100
|
1401-N44
|
| 200
|
200
|
1401-N45
|
| 400
|
400
|
1401-N46
|
| J
|
30
|
30
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
1401-N42
|
| 60
|
60
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
1401-N43
|
| 100
|
100
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
1401-N44
|
| 200
|
200
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
1401-N45
|
| 400
|
400
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
1401-N46
|
| 600
|
600
|
1494V-FS600 Fuse Blocks
|
|
| R
|
30
|
—
|
1494C, 1494F, 1494G, and 1494V Disconnect Switches
|
1401-N50
|
| 60
|
30
|
1401-N51
|
| —
|
60
|
1401-N52
|
| 100
|
100
|
1401-N53
|
| 200
|
200
|
1401-N54
|
| 400
|
400
|
1401-N55
|
| H, R
|
600
|
600
|
1491 Fuse Blocks
|
§
|
|
Class R Fuse Clip Kits 30 A @ 250V AC (Type 1, 3R, 12)
|
1494H Safety Switches
|
1401-N70
|
| 30 A @ 600V AC (Type 1, 3R)
|
1401-N71
|
| 30 A @ 600V AC (Type 12)
|
1401-N72
|
| 60 A @ 250V AC (Type 1, 3R, 12)
|
1401-N73
|
| 60 A @ 600V AC (Type 1, 3R, and 12)
|
1401-N74
|
| 100 A @ 250/600V AC (Type 1 & 3R)
|
1401-N75
|
| 100 A @ 250/600V AC (Type 12)
|
1401-N76
|
100 A @ 250/600V AC (Type 1 & 3R) 200 A @ 250/600V AC (Type 1, 3R, and 12)
|
1401-N77
|
| 30 A @ 250V AC (Type 1 & 3R)
|
1494HL Safety Switches
|
1401-N78
|
| 60 A @ 250V AC (Type 1 & 3R)
|
1401-N79
|
| 100 A @ 250V AC (Type 1 & 3R)
|
1401-N80
|
100 A @ 250V AC (Type 1 & 3R) 200 A @ 250V AC (Type 1 & 3R)
|
1401-N81
|
|
|
| § Included with Bulletin 1491 separate mounted fuse blocks. One fuse block kit per pole required.
|
| Fuse clips not required; fuse bolts directly to terminal.
|
|
Protective Fuse Covers (for use with Bul. 1494C, 1494F, 1494G, and 1494V disconnect switches)
|
| Switch Rating [A]
|
Fuse Class
|
Fuse Clip Rating [A]
|
Cat. No.
|
| 250V
|
600V
|
30 30 60 30 60 60 100
|
Non-fusible H, R H, R J J Non-fusible Non-fusible
|
— 30 60 30 60 — —
|
— — — 30 60 — —
|
1495-N64
|
30 60 100
|
H, R H, R J
|
— — 100
|
30 60 100
|
1495-N65
|
100 100
|
H, R J
|
100 200
|
100 200
|
1495-N66
|
200 200 200
|
Non-fusible H, J, R J
|
— 200 400
|
— 200 400
|
◆
|
1495-N67
|
200 200
|
Non-fusible H, J, R
|
— 200
|
— 200
|
♠
|
1495-N62
|
400 400
|
Non-fusible H, J, R
|
— 400
|
— 400
|
◆
|
1495-N68
|
400 400
|
Non-fusible H, J, R
|
— 400
|
— 400
|
♠
|
1495-N63
|
600 600
|
Non-fusible J
|
— 600
|
— 600
|
◆
|
1495-N61
|
| 600
|
H, J, R
|
600
|
600
|
∇
|
1495-N69
|
|
Protective Line Covers (for use with Bul. 1494C, 1494F, 1494G, and 1494V disconnect switches)
|
| 30, 60, 100
|
—
|
—
|
—
|
1495-N80
|
| 200
|
—
|
—
|
—
|
1495-N81
|
| 400
|
—
|
—
|
—
|
1495-N82
|
| 600
|
—
|
—
|
—
|
1495-N83
|
|
Terminal Lug Adapter Kit — allows two wires (maximum 8 AWG) to be installed on the line side or load side (for use with Bul. 1494C, 1494F, 1494G, and 1494V disconnect switches)
|
| 30
|
—
|
—
|
—
|
1494R-N16
|
| 60
|
—
|
—
|
—
|
1494R-N17
|
| 100
|
—
|
—
|
—
|
1494R-N18
|
| 200, 400
|
—
|
—
|
—
|
1494R-N19
|
|
|
| ◆ Switch with right-hand mechanism.
|
| ♠ Switch with left-hand mechanism.
|
| ∇ Used with Bulletin 1491-N621and 1491-R621 on Bulletin 1494V/1494C/1494G.
|
|
Description
|
For Use With
|
Cat. No.
|
Defeater Bracket Extension Kit For use with operating handles that do not align properly with the door catch or door hardware on enclosures with a rolled lip flange construction.
|
All 1494F and 1494V Handles (except 1494V-R1 and 1494V-R2)
|
1494V-H12
|
|
Channel Support Kits For use to prevent flexing of the operating handle mounting surface. This is especially useful when the operating handle is mounted on a channel in a multi-door enclosure.
|
30…200 A Switches Applies only to Operating Handle Cat. Nos. 1494F-P1, M1, and S1.
|
1494V-H15
|
|
Conduit Hubs (for Type 3R enclosures)★ 19.05 mm (3/4 in.) hub
|
30 A, 60 A, 100 A
|
1494H Safety Switches
|
1495-N71
|
| 25.4 mm (1 in.) hub
|
30 A, 200 A
|
1495-N72
|
| 31.75 mm (1-1/4 in.) hub
|
60 A
|
1495-N73
|
| 38.1 mm (1-1/2 in.) hub
|
100 A
|
1495-N74
|
| 50.8 mm (2 in.) hub
|
—
|
1495-N75
|
| 63.5 mm (2-1/2 in.) hub
|
200 A
|
1495-N76
|
|
Non-Metallic Conduit Connectors
1/2 in. (12.7 mm)
|
30 A
|
1494G Disconnect Switches
|
1490-N1
|
| 3/4 in. (19 mm)
|
30 A
|
1490-N9
|
| 1 in. (25.4 mm)
|
30 A
|
1490-N10
|
| 1-1/4 in. (31.75 mm)
|
60 A
|
1490-N11
|
| 1-1/2 in. (38.1 mm)
|
100 A
|
1490-N5
|
| 2 in. (50.8 mm)
|
200 A
|
1490-N6
|
| 2-1/2 in. (63.5 mm)
|
200 A
|
1490-N7
|
| 3 in. (76.2 mm)
|
400…600 A
|
1490-N8
|
|
Grounding Adapters
#14…10 AWG, 1/2 in. (12.7 mm)
|
30 A
|
1490-N19
|
| #14…8 AWG, 3/4 in. (19 mm)
|
30 A
|
1490-N20
|
| #14…8 AWG, 1 in. (24.5 mm)
|
30 A
|
1490-N21
|
| #14…4 AWG, 1-1/4 in. (31.8 mm)
|
60 A
|
1490-N22
|
| #8…1/0 AWG, 1-1/2 in. (38.1 mm)
|
100 A
|
1490-N23
|
| #8…1/0 AWG, 2 in. (50.8 mm)
|
200 A
|
1490-N24
|
| #6…2/0 AWG, 2-1/2 in. (63.5 mm)
|
200 A
|
1490-N25
|
| #6…4/0 AWG, 3 in. (76.2 mm)
|
400…600 A
|
1490-N26
|
|
|
| ★ Packaged in quantities of 10.
|
|
|
Decription
|
For Use With
|
Cat. No.♣
|
Type 12 Door Hardware Kit Includes: handle, cam, defeater actuator lever, rollers, and shims
Enclosure Height less than 40 in. (1016 mm)
Top and Side (Right Hand)
|
1494C, All 1494V
|
★
|
1494V-L1
|
| Top and Side (Left Hand)
|
★
|
1494V-LL1
|
Enclosure Height 40…60 in. (1016…1524 mm)
Top and Side (Right Hand) Bottom
|
★
|
1494V-L1
|
| and 1494V-L2
|
Top and Side (Left Hand) Bottom
|
★
|
1494V-LL1
|
| Cat. No. 1494V-L1
|
and 1494V-L2
|
|
Enclosure Height greater than 60 in. (1524 mm)
Top, Side, and Bottom (Right Hand)
|
★
|
1494V-L3
|
| Cat. No. 1494V-L2
|
Cat. No. 1494V-L3
|
Top, Side, and Bottom (Left Hand)
|
★
|
1494V-LL3
|
|
Type 12 Door Hardware Kit Includes: Handle, cam, defeater actuator lever, rollers, and shims
Enclosure Height less than 30 in. (762 mm)
Top and Side (Right Hand)
|
1494F, 1494D
|
★
|
1494F-L1
|
| Top and Bottom (Right Hand)
|
★
|
1494F-L2
|
Enclosure Height 30…48 in. (762…1219 mm)
Top and Bottom (Right Hand) Side
|
★
|
1494F-L2
|
| and 1494F-L3
|
| Cat. No. 1494F-L2 and 1494F-L3
|
Enclosure Height greater than 48 in. (1219 mm)
Top, Side, and Bottom (Right Hand)
|
|
1494F-L4
|
|
Master Door Interlock Kits Interlock kits are designed to provide interlocking between the master and auxiliary doors of the same enclosure and for use with Cat. Nos. 1494F-L4 hardware kits or Cat. No. 1494V-L3 hardware kits. Specify one master door kit and as many auxiliary door kits as necessary (9 maximum). Connecting bars must be supplied by user.
|
1494C, 1494F, 1494D, 1494V
|
§
|
1494F-N20
|
| Cat. No. 1494F-N20
|
Auxiliary Door Interlock Kit
|
1494F-N21
|
|
|
| ★ Door hardware kit does not include rectangular connecting bars (1/4 x 1/2 in.). To be provided by customer.
|
| Door hardware kit does not include rectangular connecting bars (1/4 x 5/8 in.). To be provided by customer.
|
| § Master door interlock kit does not include rectangular connecting bars (3/8 x 3/8 in.). To be provided by customer.
|
| ♣ If the Rockwell Automation door hardware kits are to be installed in a commercially available enclosure, consult the enclosure manufacturer's application data for proper kit selection.
|