600V, Non-Fusible, (3-pole, 3 phase)
| Product Overview |
|
Bulletin 1494G/1494GX1494GY — Non-Fusible
- 30…600 A switch ratings
- 600V: 3-pole, 3-phase and 6-pole, 3-phase versions
- Non-fusible versions only
- Type 3R/4/12 (painted metal), Type 4/4X (stainless steel), and Type 4/4X (non-metallic) enclosures
- 30…100 A switch ratings in extra-capacity enclosures
- 30…100 A switch ratings for 6-pole 3-phase applications
- Disconnect switch linked to the handle at all times
- Visible blade construction for safety
- Non-metallic handle — standard (30…200 A)
- Metal or stainless steel handle — optional
- Lockable handle
- Options — factory installed
- Accessories — field installed
Standards Compliance
UL 98
UL 508
CSA C22.2, No. 4
Certifications
cULus Listed (File No. E227497, Guide No. WIAX)
| 1494G | | B | F | 3 | J | 6 | | 98 | | 203W | | 414 | ||||
| a | b | c | d | e | f | g | ||||||||||
| a | b | c | |||||
| Bulletin Number | Switch Ratings [A] | Enclosure Type | |||||
| Code | Description | Code | Description | Code | Description | ||
| 1494G | Enclosed disconnect safety switch in standard-size enclosure (30…600 A) |
B | 30 | F | Type 3R/4/12: Rainproof, watertight, dusttight, painted metal enclosure with screw fasteners and non-metallic handle | ||
| 1494GY | Enclosed disconnect safety switch in large-size enclosure (30…200 A) |
C | 60 | C | Type 4/4X: Watertight, corrosion-resistant, stainless steel enclosure with screw fasteners and non-metallic handle | ||
| 1494GX | Enclosed disconnect safety switch in extra large-size enclosure (30…100 A) |
D | 100 | K | Type 12: Hazardous location (Class II, Division 2, Group F+G and Class III Division 1 and 2) painted metal enclosure with screw fasteners and non-metallic handle | ||
| E | 200 | ||||||
| F | 400 | ||||||
| G | 600 | ||||||
| d | e | f | g | |||||||
| Poles | Fusing | Fuse Voltage | Options (Factory Installed) | |||||||
| Code | Description | Code | Description | Code | Description | Code | Description | |||
| 2 | 2-pole, 1-phase | N | Non-fusible | Blank | Non-fusible | 1S | Momentary push button (Flange-mounted) |
|||
| 3 | 3-pole, 3-phase | H | Class H fuse clips | 2 | 240V AC/250V DC | 1SB | Momentary push button (Bottom-mounted) |
|||
| 6 | 6-pole, 3-phase | J | Class J fuse clips | 6 | 600V AC/600V DC | 3 | 3-position selector switch | |||
| R | Class R fuse clips | 3E | 2-position selector switch | |||||||
| 3EI | 2-position selector switch (Illuminated) | |||||||||
| 3S | 3-position selector switch (Spring return) |
|||||||||
| 4⋆ | Pilot light | |||||||||
| 5⋆ | Push-to-test pilot light | |||||||||
| 98 | N.O. auxiliary - disconnect§ | |||||||||
| 99 | N.C. auxiliary - disconnect§ | |||||||||
| 203W | Viewing window | |||||||||
| 412 | Painted metal handle | |||||||||
| 413 | Stainless steel handle | |||||||||
| 414 | Protective fuse cover | |||||||||
| 420 | 1 N.O. and 1 N.C. interlock | |||||||||
| 421 | 2 N.O. and 2 N.C. interlocks | |||||||||
⋆ Specify lens color by adding one of the following letters: R = Red, A = Amber, B = Blue, G = Green.
3-pole enclosed switches can accomodate (1) pilot device, 6-pole enclosed switches can accomodate (5) pilot devices.
§ Maximum of (2) auxiliary contacts.
600V, Non-Fusible, (3-pole, 3-phase), standard size enclosure
| Build a Catalog Number |
| Continuous Current Rating [A] 600V AC 250V DC |
Horsepower | Type 3R/4/12⋆ Painted Metal |
Type 4/4X Stainless Steel |
||||
| 480V AC | 600V AC | 250V DC |
3-Pole, 3-Phase | 3-Pole, 3-Phase | |||
| Std. | Max. | Std. | Max. | Cat. No. | Cat. No. | ||
| 30 | 5 | 20 | 7.5 | 30 | 5 | 1494G-BF3N | 1494G-BC3N |
| 60 | 15 | 50 | 15 | 60 | 10 | 1494G-CF3N | 1494G-CC3N |
| 100 | 25 | 60 | 30 | 75 | 20 | 1494G-DF3N | 1494G-DC3N |
| 200 | 50 | 125 | 60 | 150 | 40 | 1494G-EF3N | 1494G-EC3N |
| 400 | 100 | 250 | 125 | 350 | 50 | 1494G-FF3N | 1494G-FC3N |
| 600 | 150 | 400 | 200 | 500 | 50 | 1494G-GF3N | 1494G-GC3N |
600V, Non-Fusible, (3-pole, 3-phase), extra large size enclosure
| Build a Catalog Number |
| Continuous Current Rating [A] 600V AC 250V DC |
Horsepower | Type 3R/4/12⋆ Painted Metal |
Type 4/4X Stainless Steel |
||||
| 480V AC | 600V AC | 250V DC |
3-Pole, 3-Phase | 3-Pole, 3-Phase | |||
| Std. | Max. | Std. | Max. | Cat. No. | Cat. No. | ||
| 30 | 5 | 20 | 7.5 | 30 | 5 | 1494GX-BF3N | 1494GX-BC3N |
| 60 | 15 | 50 | 15 | 60 | 10 | 1494GX-CF3N | 1494GX-CC3N |
| 100 | 25 | 60 | 30 | 75 | 20 | 1494GX-DF3N | 1494GX-DC3N |
600V, Non-Fusible, (3-pole, 3-phase), large size enclosure
| Build a Catalog Number |
| Continuous Current Rating [A] 600V AC 250V DC |
Horsepower | Type 3R/4/12⋆ Painted Metal |
Type 4/4X Stainless Steel |
||||
| 480V AC | 600V AC | 250V DC |
3-Pole, 3-Phase | 3-Pole, 3-Phase | |||
| Std. | Max. | Std. | Max. | Cat. No. | Cat. No. | ||
| 30 | 5 | 20 | 7.5 | 30 | 5 | 1494GY-BF3N | 1494GY-BC3N |
| 60 | 15 | 50 | 15 | 60 | 10 | 1494GY-CF3N | 1494GY-CC3N |
| 100 | 25 | 60 | 30 | 75 | 20 | 1494GY-DF3N | — |
| 200 | 50 | 125 | 60 | 150 | 40 | 1494GY-EF3N | — |
600V, Non-Fusible, (6-pole, 3-phase), standard size enclosure
| Continuous Current Rating [A] 600V AC 250V DC |
Horsepower | Type 3R/4/12⋆ Painted Metal |
Type 4/4X Stainless Steel |
||||
| 480V AC | 600V AC | 250V DC |
6-Pole, 3-Phase | 6-Pole, 3-Phase | |||
| Std. | Max. | Std. | Max. | Cat. No. | Cat. No. | ||
| 30 | 5 | 15 | 7.5 | 20 | 5 | 1494G-BF6N | 1494G-BC6N |
| 60 | 15 | 30 | 15 | 50 | 10 | 1494G-CF6N | 1494G-CC6N |
| 100 | 25 | 60 | 30 | 75 | 20 | 1494G-DF6N | 1494G-DC6N |
| ⋆ Type 12 hazardous location enclosure (Class II, Division 2, Group F+G and Class III, Divisions 1 and 2) can be supplied by replacing the F in the listed cat. no. with the letter K. Example: Cat. No. 1494G-BK3N. | |||||||
Bulletin 1494G/1494GX1494GY Modifications — Factory-Installed
| Description | Enclosure Type | Suffix Code |
Switch Rating [A] | ||||||
| 30 | 60 | 100 | 200 | 400 | 600 | ||||
| Momentary Push Button (1 N.O.) (located on enclosure flange) | 3R/4/12 painted metal, 4/4X stainless steel | -1S⋆ | A | A | A | A | A | A | |
| Momentary Push Button (located on bottom of enclosure) | 3R/4/12 painted metal, 4/4X stainless steel | -1SB⋆ | A | A | A | A | A | A | |
| HAND-OFF-AUTO Selector Switch | 3R/4/12 painted metal, 4/4X stainless steel | -3⋆ | A | A | A | A | A | A | |
| 3-position Selector Switch | 3R/4/12 painted metal, 4/4X stainless steel | -3S⋆ | A | A | A | A | A | A | |
| 2-position Selector Switch | 3R/4/12 painted metal, 4/4X stainless steel | -3E⋆ | A | A | A | A | A | A | |
| 2-position Illuminated Selector Switch | 3R/4/12 painted metal, 4/4X stainless steel | -3EI⋆ | A | A | A | A | A | A | |
| Pilot Light | 3R/4/12 painted metal, 4/4X stainless steel | | -4⋆ | A | A | A | A | A | A |
| Push-to-test Pilot Light | 3R/4/12 painted metal, 4/4X stainless steel | | -5⋆ | A | A | A | A | A | A |
| Auxiliary Contact (1 N.O.) | 3R/4/12 painted metal, 4/4X stainless steel, 4/4X non-metallic |
§ | -98 | A | A | A | A | A | A |
| Auxiliary Contact (1 N.C.) | 3R/4/12 painted metal, 4/4X stainless steel, 4/4X non-metallic |
§ | -99 | A | A | A | A | A | A |
| Enclosure Door Viewing Window | 3R/4/12 painted metal, 4/4X stainless steel | -203W | A | A | A | A | A | A | |
| Painted Metal Handle | 3R/4/12 painted metal | ♣ | -412 | A | A | A | A | S | S |
| Stainless Steel Handle | 4/4X stainless steel | ♣ | -413 | A | A | A | A | A | A |
| Protective Fuse Cover with Door (transparent) | 3R/4/12 painted metal, 4/4X stainless steel | -414 | A | A | A | A | A | A | |
| Electrical Interlock - Early Break (1 N.O. and 1 N.C.) | 3R/4/12 painted metal, 4/4X stainless steel | -420 | A | A | A | A | A | A | |
| Electrical Interlock - Early Break (2 N.O. and 2 N.C.) | 3R/4/12 painted metal, 4/4X stainless steel | -421 | A | A | A | A | A | A | |
| Protective Line Side Cover (transparent) | 3R/4/12 painted metal, 4/4X stainless steel | -422 | A | A | A | A | A | A | |
| A = Available Option S = Standard |
|||||||||
| ⋆ Specify lens color by adding one of the following letters: R = Red, G = Green, A = Amber, B = Blue | |||||||||
| 3 pole enclosed switches can accomodate (1) pilot device, 6 pole enclosed switches can accomodate (5) pilot devices. | |||||||||
| § Maximum of (2) auxiliary contacts. | |||||||||
| ♣ Non-metallic handle provided as standard (30…200 A). For painted metal handle, select suffix code -412. For stainless steel handle, select suffix code -413. | |||||||||
Bulletin 1494C, 1494F, 1494G, 1494R, 1494V Disconnect Switches
| Disconnect Switch Electrical Ratings | ||||||||
| Switch Size | 30 A | 60 A | 100 A | 200 A | 400 A | 600 A | ||
| Rated insulation voltage Ui (UL) IEC | (600) 660V | |||||||
| Ratings UL/CSA/NEMA |
Hp | 230V/60 Hz 460V/60 Hz 575V/60 Hz |
7.5 15 20 |
15 30 50 |
30 60 75 |
60 125 150 |
125 250 350 |
200 400 500 |
| 250V DC | 5 | 10 | 20 | 40 | 50 | 50 | ||
| Continuous Current |
600V AC 250V DC |
30 | 60 | 100 | 200 | 400 | 600 | |
| Ratings IEC Applications |
Maximum kW (AC23) |
220V/50 Hz 440V/50 Hz 550V/50 Hz |
5.5 11 15 |
11 22 37 |
22 45 55 |
48 90 110 |
90 185 257 |
150 295 375 |
| Auxiliary Contact Electical Ratings | ||||||||
| NEMA/EEMAC | B600, P300 | |||||||
| IEC Ratings | Ui 660V | Ith 10 A | ||||||
ACII Ux |
12…120V 220…240V 380…400V 500…600V |
Ie |
6 A 3 A 1.5 A 1.2 A |
|||||
| Low level switching | 5 mA @ 12V DC | |||||||
| Mechanical | ||||||||
| Degree of protection | Operating handles | Non-metallic Type 1, 3R, 4, 4X, 12, Painted Type 1, 3R, 4, 12 Stainless steel Type 4, 4X |
||||||
| Mechanical life (Typical) | 20 000 operations (30…200 A) 10 000 operations (400…600 A) |
|||||||
| Switching frequency (operations/hr) | 30, 60, 100, and 200 A sizes — 300 max. 400 and 600 A sizes — 240 max. |
|||||||
| Environmental | ||||||||
| Temperature | Operating | -35…+40 °C (-31…+104 °F) | ||||||
| Storage | -40…+65 °C (-40…+149 °F) | |||||||
| Altitude (per IEC 947-5) | 2000 m per IEC 337-1 | |||||||
| Relative Humidity (per IEC 947-3) | 90% at 20 °C (68 °F) and 50% at 40 °C (104 °F) | |||||||
| Design Specification/Test Requirements | ||||||||
| Dielectric strength | 2200V for 1 minute | |||||||
| Electrical life | 6000 operations at rated current | |||||||
| Short Circuit Withstand Capability | 10 000 A: unfused 10 000 A: with Class H fuses 200 000 A: with Class J or Class R fuses |
|||||||
| Construction | ||||||||
| Switch body material | Phenolic | |||||||
| Contact material | Copper, tin-plated | |||||||
| Terminals | 30 A 60 A 100 A 200 A 400 A 600 A |
#10 - 32 screw and self-lifting pressure plate 1/4 in. - 28 screw-lug, copper 5/16 in. - 24 screw-lug, copper 3/8 in. - 24 screw-lug, copper 3/8 in. - 24 screw-lug, copper 1/2 in. - 13 screw-lug, copper |
||||||
| All wire rated 75 °C (167 °F) or higher must be sized per the local Electric Code for 75 °C (167 °F) wire. | ||||||||
| Conductor Size (mm2) | 30 A 60 A 100 A 200 A 400 A 600 A |
#14…8 AWG (1.5…10 mm2) #14…4 AWG (2.5…16 mm2) #8…1/0 AWG (10…50 mm2) #6…4/0 AWG (16…95 mm2) 2 of #1/0 AWG…250 MCM (2 per lug) 2 of 185 mm2…250 MCM or (1) #4 AWG…500 MCM 2 of #1/0 AWG…350 MCM (2 per lug) 2 of 185 mm2…350 MCM or (1) #4 AWG…500 MCM |
||||||
| Recommended Torque | 30 A 60 A 100 A 200 A 400 A 600 A |
Conductor into Lug 20 lbin 45 lbin 150 lbin 275 lbin 325 lbin 325 lbin |
Lug to Terminal 20 lbin 50 lbin 90 lbin 175 lbin 175 lbin 275 lbin |
|||||
| Switches, Mechanisms, and Accessory Kits | Zinc-plated steel, RoHS Compliant finish | |||||||
Bulletin 1494H, 1494HL Disconnect Switches
| Disconnect Switch Electrical Ratings | ||||||
| Switch Size | 30 A | 60 A | 100 A | 200 A | ||
| Rated insulation voltage Ui (UL) IEC | (600) 660V | |||||
| Ratings UL/CSA/NEMA |
Hp | 230V/60 Hz 460V/60 Hz 575V/60 Hz |
10 20 30 |
20 50 60 |
40 75 100 |
60 125 150 |
| 250V DC | 5 | 10 | 20 | 40 | ||
| Continuous Current |
600V AC 250V DC |
30 | 60 | 100 | 200 | |
| Auxiliary Contact Electical Ratings | ||||||
| Continuous Current | 10 A | 15 A | ||||
| Pole Configuration | DPDT | DPDT | ||||
| Mechanical | ||||||
| Degree of protection | Operating handles | Painted Type 1, 3R, 12 | ||||
| Mechanical life (Typical) | 10 000 operations | |||||
| Switching frequency (operations/hr) | 300 maximum | |||||
| Environmental | ||||||
| Temperature | Operating | -35…+40 °C (-31…+104 °F) | ||||
| Storage | -40…+65 °C (-40…+149 °F) | |||||
| Altitude (per IEC 947-5) | 2000 m per IEC 337-1 | |||||
| Relative Humidity (per IEC 947-3) | 90% at 20 °C (68 °F) and 50% at 40 °C (104 °F) | |||||
| Design Specification/Test Requirements | ||||||
| Dielectric strength | 2200V for 1 minute | |||||
| Electrical life | 6000 operations at rated current | |||||
| Short Circuit Withstand Capability | 10 000 A: unfused 10 000 A: with Class H fuses 200 000 A: with Class J or Class R fuses (30…100 A) 100 000 A: with Class J or Class R fuses (200 A) |
|||||
| Construction | ||||||
| Switch body material | Phenolic | |||||
| Contact material | Copper, tin-plated | |||||
| Terminals | 30 A 60 A 100 A 200 A |
#10 - 32 screw and self-lifting pressure plate 1/4 in. - 28 screw-lug, copper 5/16 in. - 24 screw-lug, copper 3/8 in. - 24 screw-lug, copper |
||||
| All wire rated 75 °C (167 °F) or higher must be sized per the local Electric Code for 75 °C (167 °F) wire. | ||||||
| Conductor Size (mm2) | 30 A 60 A 100 A 200 A |
#14…8 AWG #12…2 AWG #10…1/0 AWG #2…250 MCM AWG |
||||
| Recommended Torque | 30 A 60 A 100 A 200 A |
Conductor into Lug 36…40 lbin 35…45 lbin 35…50 lbin 275 lbin |
||||
| Mechanisms | Zinc-plated steel, bronze chromate finish | |||||
Bulletin 1494D, 1494V Circuit Breakers
| Electrical Ratings | ||||||||
| Frame Size | 125 A | 150 A | 250 A | 400 A | 600 A | 800 A | 1200 A | |
| Auxiliary Contacts | ||||||||
| 1494V, 1494D | ||||||||
| NEMA/EEMAC | B600, P300 | |||||||
| IEC Ratings | ACII Ux |
12…120V 220…240V 380…400V 500…600V |
Ie |
6 A 3 A 1.5 A 1.2 A |
||||
| Maximum Number of Auxiliary Contacts | 2 | |||||||
| Mechanical Data | ||||||||
| Mechanical Life (Typical) | 10 000 | |||||||
| Construction | ||||||||
| Mechanisms | Zinc-plated steel | |||||||
| Environmental Data | ||||||||
| Ambient Temperature⋆ | Operating | -20…+40 °C (-4…+104 °F) | ||||||
| Storage | -40…+65 °C (-40…+149 °F) | |||||||
| Altitude (per IEC 947-5) | 2000 m per IEC 337-1 | |||||||
| Relative Humidity (per IEC 947-3) | 90% at 20 °C (68 °F) and 50% at 40 °C (104 °F) | |||||||
| ⋆ Refer to circuit breaker specifications for other limitations. | ||||||||
Bulletin 1491 Fuse Blocks
| Electrical | ||||||
| UL Fuse Type | Class H | Class J | Class R | Class C | Class CC | |
| Maximum Fuse Cartridge Size | 30…600 A | 30…600 A | 30…600 A | 30…600 A | 30 A | |
| Maximum Voltage | AC | 600V | 600V | 600V | 600V | 600V |
| DC | 250V | 250V | 250V | 250V | 250V | |
| Thermal Current Rating | 30…600 A | 30…600 A | 30…600 A | 30…600 A | 30 A | |
| Maximum Short Circuit Prospective Fault Current | 10 kA | 200 kA | 200 kA | 100 kA | 200 kA | |
| Construction | ||||||
| Fuse Clips | Tin-plated copper | |||||
| Terminals | Tin-plated copper | |||||
| Fuse Block Base | Phenolic or porcelain | |||||
| Environmental | ||||||
| Ambient Temperature | Open | -20…+55 °C (-4…+131 °F) | ||||
| Enclosed | -20…+40 °C (-4…+104 °F) | |||||
| Storage | -40…+65 °C (-40…+149 °F) | |||||
| Altitude (per IEC 947-5) | 2000 m | |||||
| Relative Humidity (per IEC 947-3) | 90% at 20 °C (68 °F) and 50% at 40 °C (104 °F) | |||||
Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 1494V
|
|
|
Disconnect Switches⋆
| NEMA Size [A] |
A | B | C | D | E | F | Switch Mounting Hole Diameter | |
| Max. | Min. | Max. | ||||||
| 30 | 6-19/64 (160) |
7-31/32 (202) |
8-1/2 (216) |
21-5/8 (549) |
2-3/4 (69.9) |
7-9/16 (192) |
3-7/8 (98.5) |
7/32 in. |
| 60 | 6-19/64 (160) |
8-15/32 (215) |
8-1/2 (216) |
21-5/8 (549) |
2-9/16 (65.1) |
7-9/16 (192) |
3-7/8 (98.5) |
7/32 in. |
| 100 | 6-19/64 (160) |
9-1/8 (231.8) |
8-1/2 (216) |
21-5/8 (549) |
3-37/64 (90.9) |
7-9/16 (192) |
3-7/8 (98.5) |
7/32 in. |
| 200 | 8-5/64 (205.2) |
15-9/64 (384.5) |
9-1/2 (241.3) |
21-5/8 (549) |
6-35/64 (166.3) |
8-25/32 (223) |
4-21/32 (118) |
19/64 in. |
| 400 | 11 (279.4) |
18-7/32 (462.7) |
10-1/2 (266.7) |
21-5/8 (549) |
8 (203.2) |
10 (254) |
5-1/2 (139.7) |
11/32 in. |
| 600 | 15-23/32 (399.2) |
17-19/32 (446.8)§ |
10-1/2 (266.7) |
21-5/8 (549) |
12 (304.8) |
11-27/32 (300.8) |
8-51/64 (223.3) |
11/32 in. |
| ⋆ Approximate dimensions are for reference only. | ||||||||
| This approximate dimension will vary by fuse class and size. | ||||||||
| § Approximate dimension with Class J fuses. | ||||||||
Circuit Breakers♣
| Frame | A | C | D | E | F | |
| Min. | Max. | |||||
| 125A 140U-H, 140M-H, EF, HMCPE 150A 140U-I, 140M-I EHD, FD, FDB, FDC, HFD, HMCP |
6 (152.4) |
6-3/4 (171.5) |
23 (584.2) |
6 (152.4) |
5-7/16 (138.1) |
5 (127) |
| 250A 140U-J, 140M-J 250A JD, JDB, JDC, HJD, HMCP |
11-1/4 (285.8) |
7-7/8 (200.0) |
22-9/16 (573.1) |
10 (254) |
5-23/32 (145.2) |
9-23/32 (246.8) |
| 400 A 140U-K, 140M-K KD, KDB, KDC, HKD, HMCP 600 A 140U-L |
11-3/8 (228.9) |
7-7/8 (200.0) |
22-9/16 (573.1) |
12 (304.8) |
7-1/8 (181.0) |
9-21/32 (245.3) |
| ♣ Approximate dimensions are for reference only. | ||||||
Bulletin 1494C
|
Disconnect Switches
| NEMA Size [A] |
AA | BB | CC | DD | EE Mounting Plate Hole Diameter |
FF Minimum Bevel Diameter |
| 30 | 2-1/4 (57.2) |
5-1/4 (133.4) |
2-1/4 (57.2) |
— | 11/64 (4.37) |
12 (304.8) |
| 60 | 2-1/4 (57.2) |
5-1/4 (133.4) |
2-1/4 (57.2) |
— | 11/64 (4.37) |
12 (304.8) |
| 100 | 2-1/4 (57.2) |
5-1/4 (133.4) |
2-1/4 (57.2) |
— | 11/64 (4.37) |
12 (304.8) |
| 200 | 2 (50.8) |
8-1/4 (209.6) |
4-1/4 (108) |
1-1/8 (28.6) |
7/32 (5.56) |
16 (406.4) |
| 400 | 2 (50.8) |
11 (279.4) |
4-3/4 (120.7) |
1-3/8 (34.9) |
9/32 (7.14) |
16 (406.4) |
| 600 | 8-1/4 (209.6) |
15 (381) |
8-1/4 (209.6) |
— | — | 16 (406.4) |
Bulletin 1494F Disconnect Switches
Non-Fusible Disconnect Switch
|
Fusible Disconnect Switch
|
| Switch Size [A] | A | B | C | D | E | F | G | H | J | K | L | M | N | P | Q | R |
| 30 | 9-3/16 (233.4) |
4-5/16 (109.5) |
1-1/8 (28.6) |
6 (152.4) |
3/8 (9.5) |
1-9/16 (39.7) |
10-1/2 (266.7) |
8-1/2 (215.9) |
6-7/8 (174.6) |
8 (203.2) |
8-1/2 (215.9) |
15/16 (23.8) |
3-21/32 (92.9) |
7-5/16 (185.7) |
3 (76.2) |
5-7/16 (138.1) |
| 60 | 9-3/16 (233.4) |
4-5/16 (109.5) |
1-1/8 (28.6) |
6 (152.4) |
3/8 (9.5) |
1-9/16 (39.7) |
10-1/2 (266.7) |
8-1/2 (215.9) |
6-7/8 (174.6) |
8 (203.2) |
8-1/2 (215.9) |
15/16 (23.8) |
3-21/32 (92.9) |
7-5/16 (185.7) |
3 (76.2) |
5-7/16 (138.1) |
| 100 | 9-3/16 (233.4) |
4-5/16 (109.5) |
1-1/8 (28.6) |
6 (152.4) |
3/8 (9.5) |
1-9/16 (39.7) |
10-1/2 (266.7) |
9-3/4 (247.7) |
8-1/8 (206.4) |
8 (203.2) |
8-1/2 (215.9) |
15/16 (23.8) |
3-21/32 (92.9) |
7-5/16 (185.7) |
3 (76.2) |
5-7/16 (138.1) |
| 200 | 9-5/8 (244.5) |
4-3/4 (120.7) |
1-5/32 (29.4) |
8-3/16 (208) |
7/16 (11.1) |
2 (50.8) |
10-29/32 (277) |
9-3/4 (247.7) |
8-1/8 (206.4) |
8 (203.2) |
8-1/2 (215.9) |
1-5/16 (33.3) |
3-3/4 (95.3) |
7-1/2 (190.5) |
3 (76.2) |
5-7/16 (138.1) |
Bulletin 1494F Disconnect Switches Vault Hardware Latching (Non Pre-drilled Enclosures)
|
| Vault Hardware Kits⋆ | Switch Size [A] | A | B | C (Min.) |
D | E (Min.) |
F | G (Min.) |
H (Min.) |
J (Min.) |
K | L | M | N |
| Small and Intermediate Enclosures | ||||||||||||||
| 1494F-L1 1494F-L2 1494F-L3 |
30 | 3-7/8 (98.4) |
3/8 (9.5) |
3-1/16 (77.8) |
2-1/8 (54) |
4-1/2 (114.3) |
3-13/16 (96.8) |
13 (330.2) |
8-1/8 (206.4) |
5 (127) |
1/2 (12.7) |
1/4 (6.4) |
11/16 (17.5) |
1/2 (12.7) |
| 60 | 14 (355.6) |
|||||||||||||
| 100 | 18-7/8 (479.4) |
|||||||||||||
| 200 | 23-25/32 (604) |
|||||||||||||
| Large Enclosures | ||||||||||||||
| 1494F-L4 | 30 | 4 (101.6) |
1/2 (12.7) |
3-3/4 (95.3) |
2-1/8 (54) |
5 (127) |
3-13/16 (96.8) |
13-1/8 (333.4) |
9-13/16 (249.2) |
6 (152.4) |
5/8 (15.9) |
5/16 (7.9) |
1-1/4 (31.8) |
3/4 (19.1) |
| 60 | 13-5/8 (346.1) |
|||||||||||||
| 100 | 18-1/2 (469.9) |
|||||||||||||
| 200 | 23-13/32 (594.5) |
|||||||||||||
Bulletin 1494D Circuit Breakers♣
|
|
| Cutler-Hammer Frame | A | C | D | E | F | |
| Min. | Max. | |||||
| 150 A — EHD, FD, FDB, FDC, HFD, HMCP | 7-13/16 (198.4) | 6-3/8 (161.9) | — | 6 (152.4) | 5-5/8 (142.9) | 6-7/16 (163.5) |
| 250 A — JD, JDB, JDC, HJD, HMCP | 11-1/2 (292.1) | 8-3/8 (212.7) | — | 8 (203.2) | 5-13/16 (147.6) | 9-7/16 (239.7) |
| 400 A — KD, KDB, KDC, HKD, HMCP | 11-1/2 (292.1) | 8-3/8 (212.7) | — | 12 (304.8) | 6-7/8 (174.6) | 9-7/16 (239.7) |
| 600 A — LD, HLD, LDC, LA, HLA, LC, HLC | 11-3/8 (288.9) | 9-1/2 (241.3) | — | 8 (203.2) | 12 (304.8) | 10-17/32 (267.5) |
| 800 A — MA, MDL, HMDL, HMA, MC, ND, HND, NDC | 16 (406.4) | 9-1/2 (241.3) | — | 10 (254) | 12-5/16 (312.7) | 15-3/32 (183.4) |
| 1200 A — NB TRI-PAK | 22 (558.8) | 9-1/2 (241.3) | — | 10 (254) | 12-5/16 (312.7) | 21-3/32 (535.8) |
| 1200 A — HNC, ND, HND, NDC, NB, HNB, NC, HNC | 16 (406.4) | 9-1/2 (241.3) | — | 12 (304.8) | 12-5/16 (312.7) | 25-3/32 (183.4) |
| ♣ Approximate dimensions are for reference only. | ||||||
Bulletin 1494G, 1494GX, 1494GY Enclosed Disconnect Safety Switches
Type 3R/4/12 (Enclosure Code "F") Painted Metal Enclosures
|
| Size [A] | Fuse Style⋆ |
Number of Poles |
Bulletin No. |
Approximate Dimensions in Inches (Millimeters) | Approx. Shipping Weight [lb (kg)] |
||||||||
| A Height |
B Width |
C Depth |
D Mounting |
E Mounting |
F Mounting |
G Handle Depth |
H | J | |||||
| 30 | A | 2 or 3 | 1494G | 13-5/16 (338) |
10-1/2 (267) |
8-1/4 (210) |
14-11/16 (373) |
| 5-1/4 (133) |
5-9/16 (141) |
15-21/32 (398) |
11/32 (9) |
20 (9.07) |
| 60 | |||||||||||||
| 30 | B | 2 or 3 | 1494G | 20 (509) |
10-1/2 (267) |
10-3/16 (259) |
21-7/16 (545) |
| 5-1/4 (133) |
5-9/16 (141) |
22-13/32 (569) |
11/32 (9) |
30 (13.6) |
| 60 | |||||||||||||
| 100 | A | ||||||||||||
| 30 | C | 6 | 1494G | 27-1/2 (698) |
10-1/2 (267) |
8-1/4 (210) |
28-7/8 (733) |
| 5-1/4 (133) |
5-9/16 (141) |
29-7/8 (759) |
13/16 (21) |
60 (27.21) |
| D | |||||||||||||
| 60 | C | ||||||||||||
| D | |||||||||||||
| 30 | A | 2 or 3 | 1494GY | ||||||||||
| B | |||||||||||||
| 60 | A | ||||||||||||
| B | |||||||||||||
| 30 | A | 2 or 3 | 1494GX | 30 (762) |
20-1/2 (521) |
10-3/16 (259) |
31-3/8 (797) |
15-1/4 (387) |
15-1/4 (387) |
5-9/16 (141) |
32-3/8 (822) |
13/16 (21) |
90 (40.82) |
| B | |||||||||||||
| 60 | A | ||||||||||||
| B | |||||||||||||
| 100 | D | 6 | 1494G | ||||||||||
| 100 | A | 2 or 3 | 1494GY | ||||||||||
| B | |||||||||||||
| 100 | B | 2 or 3 | 1494G | 31-1/2 (800) |
10-1/2 (267) |
10-3/32 (257) |
32-7/8 (835) |
| 5-1/4 (133) |
5-9/16 (141) |
33-27/32 (860) |
11/32 (9) |
70 (31.73) |
| C | 6 | ||||||||||||
| 200 | A | 2 or 3 | |||||||||||
| B | |||||||||||||
| 100 | A | 2 or 3 | 1494GX | 50 (1270) |
22 (559) |
11-1/2 (292) |
51-3/8 (1305) |
15-1/4 (387) |
15-1/4 (387) |
5-9/16 (141) |
52-11/32 (1330) |
11/32 (9) |
200 (90.7) |
| B | |||||||||||||
| 200 | C | 6 | 1494G | ||||||||||
| D | |||||||||||||
| 200 | A | 2 or 3 | 1494GY | ||||||||||
| B | |||||||||||||
| 400 | A | 2 or 3 | 1494G | 50 (1270) |
22 (559) |
11-1/2 (292) |
51-3/8 (1305) |
15-1/4 (387) |
15-1/4 (387) |
7-5/8 (194) |
52-11/32 (1330) |
11/32 (9) |
200 (90.7) |
| 600 | A | ||||||||||||
| 400 | B | 2 or 3 | 1494G | 56 (1422) |
30-1/2 (775) |
13-51/64 (350) |
57-5/8 (1464) |
20 (508) |
25-1/4 (641) |
7-5/8 (194) |
62-5/8 (1590) |
1 (25.4) |
300 (136.05) |
| 600 | B | ||||||||||||
| ⋆ A = Non-Fusible, Fusible 250V - Class H/R, Fusible 600V - Class J B = Fusible 600V - Class H/R C = Non-fusible D = Fusible 250V - Class H/R, Fusible 600V - Class J |
|||||||||||||
| These enclosures have one top mounting hole located on the center line. All other enclosures have two top mounting holes located as shown. | |||||||||||||
Bulletin 1494G, 1494GX, 1494GY Enclosed Disconnect Safety Switches
Type 4/4X (Enclosure Code "C") Stainless Steel Enclosure
|
| Size [A] | Fuse Style⋆ |
Number of Poles |
Bulletin No. |
Approximate Dimensions in Inches (Millimeters) | Approx. Shipping Weight [lb (kg)] |
||||||||
| A Height |
B Width |
C Depth |
D Mounting |
E Mounting |
F Mounting |
G Handle Depth |
H | J | |||||
| 30 | A | 2 or 3 | 1494G | 13-5/16 (338) |
10-1/2 (267) |
8-9/16 (217) |
14-11/16 (373) |
| 5-1/4 (133) |
5-9/16 (141) |
15-21/32 (398) |
13/16 (21) |
20 (9.07) |
| 60 | |||||||||||||
| 30 | B | 2 or 3 | 1494G | 27-1/2 (698) |
10-1/2 (267) |
8-1/4 (210) |
28-7/8 (733) |
| 7 (178) |
5-9/16 (141) |
29-3/4 (756) |
13/16 (21) |
60 (27.21) |
| C | 6 | ||||||||||||
| D | |||||||||||||
| 60 | B | 2 or 3 | |||||||||||
| C | 6 | ||||||||||||
| D | |||||||||||||
| 30 | A | 2 or 3 | 1494GY | ||||||||||
| B | |||||||||||||
| 60 | A | ||||||||||||
| B | |||||||||||||
| 30 | A | 2 or 3 | 1494GX | 30 (762) |
20-1/2 (521) |
9-7/8 (251) |
31-3/8 (797) |
17 (432) |
17 (432) |
5-9/16 (141) |
32-1/4 (819) |
13/16 (21) |
90 (40.82) |
| B | |||||||||||||
| 60 | A | ||||||||||||
| B | |||||||||||||
| 100 | A | 2 or 3 | 1494G | ||||||||||
| B | |||||||||||||
| C | 6 | ||||||||||||
| D | |||||||||||||
| 100 | A | 2 or 3 | 1494GX | 50 (1270) |
22 (559) |
11-3/16 (284) |
51-3/8 (1305) |
18-1/2 (470) |
18-1/2 (470) |
5-9/16 (141) |
52-1/4 (1327) |
13/16 (21) |
200 (90.7) |
| B | |||||||||||||
| 200 | A | 2 or 3 | 1494G | ||||||||||
| B | |||||||||||||
| C | 6 | ||||||||||||
| D | |||||||||||||
| 400 | A | 2 or 3 | 1494G | 56 (1422) |
30-1/2 (775) |
13-51/64 (350) |
57-5/8 (1464) |
20 (508) |
25-1/4 (641) |
7-5/8 (194) |
58-5/8 (1489) |
1 (25.4) |
300 (136.05) |
| B | |||||||||||||
| 600 | A | ||||||||||||
| B | |||||||||||||
| ⋆ A = Non-Fusible, Fusible 250V - Class H/R, Fusible 600V - Class J B = Fusible 600V - Class H/R C = Non-fusible D = Fusible 250V - Class H/R, Fusible 600V - Class J |
|||||||||||||
| These enclosures have one top mounting hole located on the center line. All other enclosures have two top mounting holes located as shown. | |||||||||||||
Bulletin 1494H Heavy Duty Safety Switches
Type 1 (Enclosure Code "A") General Purpose Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
Knockout Fig. # |
| 30 | 240V | 10-9/32 (261.1) | 6-3/8 (162.1) | 3-5/16 (84.1) | 7-1/8 (181) | 1 |
| 600V | 12-19/32 (319.8) | 8-3/8 (212.9) | 4 (101.6) | 9-1/2 (241.3) | 2 | |
| Non-fusible | 10-3/8 (263.7) | 8-3/8 (212.9) | 4 (101.6) | 9-1/4 (235) | 3 | |
| 60 | 240V | 17-19/32 (446.8) | 9-3/8 (238.3) | 5 (127) | 10-3/64 (255.3) | 4 |
| 600V | 21-11/32 (542) | 5 | ||||
| Non-fusible | 17-19/32 (446.8) | 4 | ||||
| 100 | 240V | 21-11/32 (542) | 9-3/8 (238.3) | 5 (127) | 10-3/64 (255.3) | 5 |
| 600V | 22-11/32 (567.4) | 4 | ||||
| Non-fusible | 17-19/32 (446.8) | 4 | ||||
| 200 | 240V | 31-5/8 (803.3) | 13-7/16 (341.4) | 5-1/4 (133.4) | 14-7/16 (366) | 6 |
| 600V | ||||||
| Non-fusible | ||||||
Knockouts — Conduit Size
|
|
|
||
| Fig. 1 | Fig. 2 | Fig. 3 | ||
|
|
|
||
| Fig. 4 | Fig. 5 | Fig. 6 | ||
| Switch Size [A] | Fuse Style | Knockouts | ||||
| A | B | C | D | E | ||
| 30 | 240V | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
3/8 x 1/2 x 3/4 x 1 (9.5 x 12.7 x 19.1 x 25.4) |
— | — |
| 600V | 1/2 x 3/4 x 1 (12.7 x 19.1 x 25.4) |
1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
|||
| Non-fusible | ||||||
| 60 | 240V | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
— |
| 600V | ||||||
| Non-fusible | ||||||
| 100 | 240V | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
— |
| 600V | ||||||
| Non-fusible | ||||||
| 200 | 240V | 1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
9/32 (7.1) | 1/2 (12.7) |
— | — |
| 600V | ||||||
| Non-fusible | ||||||
Bulletin 1494H Heavy Duty Safety Switches
Type 3R (Enclosure Code "N") Rain-Proof Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
Knockout Fig. # |
| 30 | 240V | 10-5/8 (269.9) | 6-3/8 (162.1) | 3-5/16 (84.1) | 7-1/8 (181) | 7 |
| 600V | 13-13/64 (335.3) | 8-3/8 (212.9) | 4 (101.6) | 9-13/32 (239) | 8 | |
| Non-fusible | 13-13/64 (335.3) | 8-3/8 (212.9) | 4 (101.6) | 9-13/32 (239) | 8 | |
| 60 | 240V | 17-7/16 (443) | 9-3/8 (238.3) | 5 (127) | 10-3/64 (255.3) | 9 |
| 600V | 22-3/16 (563.6) | 10-1/2 (267) | ||||
| Non-fusible | 17-7/16 (443) | 10-3/64 (255.3) | ||||
| 100 | 240V | 22-3/16 (563.6) | 9-3/8 (238.3) | 5 (127) | 10-1/2 (267) | 9 |
| 600V | 22-3/16 (563.6) | |||||
| Non-fusible | 17-7/16 (443) | 10-3/64 (255.3) | ||||
| 200 | 240V | 31-7/16 (798.6) | 13-3/8 (339.9) | 5-15/32 (138.9) | 14-1/8 (361.9) | 10 |
| 600V | ||||||
| Non-fusible | ||||||
Knockouts — Conduit Size
|
|
|
|
|||
| Fig. 7 | Fig. 8 | Fig. 9 | Fig. 10 |
| Switch Size [A] | Fuse Style | Knockouts | |||
| A | B | C | D | ||
| 30 | 240V | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
3/8 x 1/2 x 3/4 x 1 (9.5 x 12.7 x 19.1 x 25.4) |
— |
| 600V | 1/2 x 3/4 x 1 (12.7 x 19.1 x 25.4) |
1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
||
| Non-fusible | |||||
| 60 | 240V | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
| 600V | |||||
| Non-fusible | |||||
| 100 | 240V | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
| 600V | |||||
| Non-fusible | |||||
| 200 | 240V | 1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
9/32 (7.1) | 1/2 (12.7) |
— |
| 600V | — | ||||
| Non-fusible | — | ||||
Bulletin 1494H Heavy Duty Safety Switches
Type 12 (Enclosure Code "F") Dust-Tight Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
| 30 | 240V | 11-3/8 (288.9) | 7-3/8 (187.3) | 5-1/16 (128.6) | 8-1/8 (206.4) |
| 600V | 13-3/8 (339.7) | 9-3/8 (238.1) | 5-5/16 (134.9) | 10-1/4 (260.4) | |
| Non-fusible | 5-1/16 (128.6) | ||||
| 60 | 240V | 19-3/8 (492.1) | 9-3/8 (238.1) | 5-1/16 (128.6) | 10-1/4 (260.4) |
| 600V | 5-5/16 (134.9) | ||||
| Non-fusible | 5-1/16 (128.6) | ||||
| 100 | 240V | 25-3/8 (644.5) | 13-1/2 (342.9) | 5-1/16 (128.6) | 14-1/4 (362) |
| 600V | 5-5/16 (134.9) | ||||
| Non-fusible | |||||
| 200 | 240V | 35-1/8 (892.2) | 13-1/2 (342.9) | 5-5/16 (134.9) | 15-1/4 (387.4) |
| 600V | 14-1/2 (368.3) | ||||
| Non-fusible | |||||
Bulletin 1494HL General Duty Safety Switches
Type 1 (Enclosure Code "A") General Purpose Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
Knockout Fig. # |
| 30 | 240V | 10-9/32 (261.1) | 6-1/2 (165.1) | 3-5/16 (84.1) | 6-29/32 (175.3) | 1 |
| 60 | 13-27/32 (351.5) | 8-1/2 (215.9) | 4 (101.6) | 8-7/8 (225.6) | 2 | |
| 100 | 21-11/32 (542) | 9-1/2 (241.3) | 5 (127) | 9-7/8 (251) | 3 | |
| 200 | 29-1/8 (739.6) | 13-7/16 (341.4) | 5-5/16 (134.9) | 13-15/16 (354.1) | 4 | |
Knockouts — Conduit Size
|
|
|
|
|||
| Fig. 1 | Fig. 2 | Fig. 3 | Fig. 4 |
| Switch Size [A] | Knockouts | ||||
| A | B | C | D | E | |
| 30 | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
3/8 x 1/2 x 3/4 x 1 (9.5 x 12.7 x 19.1 x 25.4) |
— | — |
| 60 | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
1/2 x 3/4 x 1 (12.7 x 19.1 x 25.4) |
1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
| 100 | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
— |
| 200 | 1/2 (12.7) | 1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
9/32 (7.1) | — | — |
Type 3R (Enclosure Code "N") Rain-Proof Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
Knockout Fig. # |
| 30 | 240V | 10-1/32 (254.8) | 6-3/8 (162.1) | 3-5/16 (84.1) | 7-1/8 (180.8) | 5 |
| 60 | 13-15/16 (353.8) | 8-3/8 (212.9) | 3-7/8 (225.6) | 9-3/32 (230.9) | 6 | |
| 100 | 21-7/16 (544.3) | 9-3/8 (238.3) | 5 (127) | 9-61/64 (252.7) | 7 | |
| 200 | 28-15/16 (735.1) | 13-3/8 (339.9) | 5-5/16 (134.9) | 14-1/16 (357.1) | 8 | |
Knockouts — Conduit Size
|
|
|
|
|||
| Fig. 5 | Fig. 6 | Fig. 7 | Fig. 8 |
| Switch Size [A] | Knockouts | |||
| A | B | C | D | |
| 30 | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
3/8 x 1/2 x 3/4 x 1 (9.5 x 12.7 x 19.1 x 25.4) |
— |
| 60 | 9/32 (7.1) | 1/2 x 3/4 x 1 (12.7 x 19.1 x 25.4) |
1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
| 100 | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
| 200 | 1/2 (12.7) | 1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
— |