600V, Fusible with Class H Fuse Clips

Product Overview


Click to enlarge - 1494-2_1-3
Cat. No. 1494G-BF3J6
Enclosed Disconnect Switch


Bulletin 1494G/1494GX/1494GY — Fusible, 600V


Standards Compliance

UL 98
UL 508
CSA C22.2, No. 4


Certifications

cULus Listed (File No. E227497, Guide No. WIAX)

1494G B    F    3    J    6 98 203W 414
a    b    c    d    e    f    g

a    b    c
Bulletin Number Switch Ratings [A] Enclosure Type
Code Description Code Description Code Description
1494G Enclosed disconnect safety switch in standard-size enclosure
(30…600 A)
B 30 F Type 3R/4/12: Rainproof, watertight, dusttight, painted metal enclosure with screw fasteners and non-metallic handle
1494GY Enclosed disconnect safety switch in large-size enclosure
(30…200 A)
C 60 C Type 4/4X: Watertight, corrosion-resistant, stainless steel enclosure with screw fasteners and non-metallic handle
1494GX Enclosed disconnect safety switch in extra large-size enclosure
(30…100 A)
D 100 K Type 12: Hazardous location (Class II, Division 2, Group F+G and Class III Division 1 and 2) painted metal enclosure with screw fasteners and non-metallic handle
  E 200  
F 400
G 600

d    e    f    g
Poles Fusing Fuse Voltage Options (Factory Installed)
Code Description Code Description Code Description Code Description
2 2-pole, 1-phase N Non-fusible Blank Non-fusible 1S Momentary push button‡ 
(Flange-mounted)
3 3-pole, 3-phase H Class H fuse clips 2 240V AC/250V DC 1SB Momentary push button‡ 
(Bottom-mounted)
6 6-pole, 3-phase J Class J fuse clips 6 600V AC/600V DC 3 3-position selector switch‡ 
  R Class R fuse clips   3E 2-position selector switch‡ 
  3EI 2-position selector switch‡  (Illuminated)
3S 3-position selector switch‡ 
(Spring return)
4⋆  Pilot light‡ 
5⋆  Push-to-test pilot light‡ 
98 N.O. auxiliary - disconnect§ 
99 N.C. auxiliary - disconnect§ 
203W Viewing window
412 Painted metal handle
413 Stainless steel handle
414 Protective fuse cover
420 1 N.O. and 1 N.C. interlock
421 2 N.O. and 2 N.C. interlocks

⋆ Specify lens color by adding one of the following letters: R = Red, A = Amber, B = Blue, G = Green.
‡ 3-pole enclosed switches can accomodate (1) pilot device, 6-pole enclosed switches can accomodate (5) pilot devices.
§ Maximum of (2) auxiliary contacts.


600V, Fusible with Class H Fuse Clips, (3-pole, 3-phase), standard size enclosure⋆ 

Build a Catalog Number


Continuous Current Rating [A]
600V AC
250V DC
Horsepower Type 3R/4/12‡ 
Painted Metal
Type 4/4X
Stainless Steel
480V AC 600V AC 250V
DC
3-Pole, 3-Phase 3-Pole, 3-Phase
Std. Max. Std. Max. Cat. No. Cat. No.
30 5 15 7.5 20 5 1494G-BF3H6 1494G-BC3H6
60 15 30 15 50 10 1494G-CF3H6 1494G-CC3H6
100 25 60 30 75 20 1494G-DF3H6 1494G-DC3H6
200 50 125 60 150 40 1494G-EF3H6 1494G-EC3H6
400 100 250 125 350 50 1494G-FF3H6 1494G-FC3H6
600 150 400 200 500 50 1494G-GF3H6 1494G-GC3H6
  

600V, Fusible with Class H Fuse Clips, (3-pole, 3-phase), extra large size enclosure⋆ 

Build a Catalog Number


Continuous Current Rating [A]
600V AC
250V DC
Horsepower Type 3R/4/12‡ 
Painted Metal
Type 4/4X
Stainless Steel
480V AC 600V AC 250V
DC
3-Pole, 3-Phase 3-Pole, 3-Phase
Std. Max. Std. Max. Cat. No. Cat. No.
30 5 15 7.5 20 5 1494GX-BF3H6 1494GX-BC3H6
60 15 30 15 50 10 1494GX-CF3H6 1494GX-CC3H6
100 25 60 30 75 20 1494GX-DF3H6 1494GX-DC3H6
  

600V, Fusible with Class H Fuse Clips, (3-pole, 3-phase), large size enclosure⋆ 

Build a Catalog Number


Continuous Current Rating [A]
600V AC
250V DC
Horsepower Type 3R/4/12‡ 
Painted Metal
Type 4/4X
Stainless Steel
480V AC 600V AC 250V
DC
3-Pole, 3-Phase 3-Pole, 3-Phase
Std. Max. Std. Max. Cat. No. Cat. No.
30 5 15 7.5 20 5 1494GY-BF3H6 1494GY-BC3H6
60 15 30 15 50 10 1494GY-CF3H6 1494GY-CC3H6
100 25 60 30 75 20 1494GY-DF3H6
200 50 125 60 150 40 1494GY-EF3H6
  

600V, Fusible with Class H Fuse Clips, (6-pole, 3-phase), standard size enclosure⋆ 

Continuous Current Rating [A]
600V AC
250V DC
Horsepower Type 3R/4/12‡ 
Painted Metal
Type 4/4X
Stainless Steel
480V AC 600V AC 250V
DC
6-Pole, 3-Phase 6-Pole, 3-Phase
Std. Max. Std. Max. Cat. No. Cat. No.
30 5 15 7.5 20 5 1494G-BF6J6 1494G-BC6J6
60 15 30 15 50 10 1494G-CF6J6 1494G-CC6J6
100 25 60 30 75 20 1494G-DF6J6 1494G-DC6J6
  
⋆ Class R and J fuse clips can be supplied as a factory option in place of Class H clips. To order Class R fuse clips, replace H from the cat. no. with R. Example: Cat. No. 1494G-BF3H6 becomes 1494G-BF3R6. To order Class J fuse clips, replace H from the cat. no. with J. Example: Cat. No. 1494G-BF3H6 becomes 1494G-BF3J6. The same applies to Bul. 1494GX and 1494GY.
‡ Type 12 hazardous location enclosure (Class II, Division 2, Group F+G and Class III, Divisions 1 and 2) can be supplied by replacing the F in the listed cat. no. with the letter K. Example: Cat. No. 1494G-BK3H2.

Bulletin 1494G/1494GX1494GY Modifications — Factory-Installed

Description Enclosure Type Suffix
Code
Switch Rating [A]
30 60 100 200 400 600
Momentary Push Button (1 N.O.) (located on enclosure flange) 3R/4/12 painted metal, 4/4X stainless steel -1S⋆  A A A A A A
Momentary Push Button (located on bottom of enclosure) 3R/4/12 painted metal, 4/4X stainless steel -1SB⋆  A A A A A A
HAND-OFF-AUTO Selector Switch 3R/4/12 painted metal, 4/4X stainless steel -3⋆  A A A A A A
3-position Selector Switch 3R/4/12 painted metal, 4/4X stainless steel -3S⋆  A A A A A A
2-position Selector Switch 3R/4/12 painted metal, 4/4X stainless steel -3E⋆  A A A A A A
2-position Illuminated Selector Switch 3R/4/12 painted metal, 4/4X stainless steel -3EI⋆  A A A A A A
Pilot Light 3R/4/12 painted metal, 4/4X stainless steel ‡  -4⋆  A A A A A A
Push-to-test Pilot Light 3R/4/12 painted metal, 4/4X stainless steel ‡  -5⋆  A A A A A A
Auxiliary Contact (1 N.O.) 3R/4/12 painted metal, 4/4X stainless steel,
4/4X non-metallic
§  -98 A A A A A A
Auxiliary Contact (1 N.C.) 3R/4/12 painted metal, 4/4X stainless steel,
4/4X non-metallic
§  -99 A A A A A A
Enclosure Door Viewing Window 3R/4/12 painted metal, 4/4X stainless steel -203W A A A A A A
Painted Metal Handle 3R/4/12 painted metal ♣  -412 A A A A S S
Stainless Steel Handle 4/4X stainless steel ♣  -413 A A A A A A
Protective Fuse Cover with Door (transparent) 3R/4/12 painted metal, 4/4X stainless steel -414 A A A A A A
Electrical Interlock - Early Break (1 N.O. and 1 N.C.) 3R/4/12 painted metal, 4/4X stainless steel -420 A A A A A A
Electrical Interlock - Early Break (2 N.O. and 2 N.C.) 3R/4/12 painted metal, 4/4X stainless steel -421 A A A A A A
Protective Line Side Cover (transparent) 3R/4/12 painted metal, 4/4X stainless steel -422 A A A A A A
  
A = Available Option
S = Standard
⋆ Specify lens color by adding one of the following letters: R = Red, G = Green, A = Amber, B = Blue
‡ 3 pole enclosed switches can accomodate (1) pilot device, 6 pole enclosed switches can accomodate (5) pilot devices.
§ Maximum of (2) auxiliary contacts.
♣ Non-metallic handle provided as standard (30…200 A). For painted metal handle, select suffix code -412. For stainless steel handle, select suffix code -413.

Click to enlarge - 1494-2_18-1 Description For Use With Cat. No.
Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G (30…400 A) Disconnect Switches

1494D, 1494V⋆  (125…400 A Frame) Circuit Breakers
1495-N8
1 N.O. Contact (low-level switching) 1495-N8X
1 N.C. Contact 1495-N9
1 N.C. Contact (low-level switching) 1495-N9X
Click to enlarge - 1494-2_18-4 Click to enlarge - 1494-2_18-5 Auxiliary Contacts (600 A Disconnect Switch only) 1 N.O. Contact 1494C, 1494G, and 1494V Disconnect Switches
600 A only
595-A
Cat. No. 595-A Cat. No. 595-B 1 N.C. Contact 595-B
Click to enlarge - 1494-2_18-6 Auxiliary Contact Adapter Kit For Disconnect Switches 600 A ‡  595-N1
Cat. No. 595-N1
Click to enlarge - 1495_N24_GS Auxiliary Contact Adapter Kit For Disconnect Switches with Left-Hand Mechanism 30…100 A Disconnect Switch 1494V Disconnect Switch with Left-Hand Mechanism,
30…100 A
‡  1495-N24
Cat. No. 1495-N24 200…400 A Disconnect Switch 1494V Disconnect Switch with Left-Hand Mechanism,
200…400 A
‡  1495-N25
Click to enlarge - 1494-2_18-2 Click to enlarge - 1494-2_18-3 Auxiliary Contact Adapter Kit For Circuit Breakers 125 A and 150 A Frame Allen‑Bradley, Cutler-Hammer 1494D, 1494V Circuit Breakers ‡  1495-N21
250 A, 400 A Frame Allen‑Bradley, Cutler-Hammer 1494V Circuit Breaker ‡  1495-N23
250 A Frame Allen-Bradley, Cutler-Hammer 1494D Circuit Breaker ‡  1495-N22
400 A Frame Allen-Bradley, Cutler-Hammer 1494D Circuit Breaker ‡  1495-N16
Cat. No.
1495-N21
Cat. No.
1495-N23
600 A, 800 A, 1200 A Frame
Cutler-Hammer
1494D Circuit Breaker ‡  1495-N13
Click to enlarge - 1494-2_18-7 Click to enlarge - 1494-2_18-8 Auxiliary Contacts 1 N.O. Contact 1494R Disconnect Switch 30 A, 60 A 895-A1
1 N.C. Contact 895-B1
1 N.O. and 1 N.C. Contact 895-C1
Auxiliary Contact Adapter Kit for 1 contact 895-M11
Cat. No. 895-A1 Cat. No. 895-M11 Auxiliary Contact Adapter Kit for 2 contacts 895-M12
Click to enlarge - 1494-2_18-9 Click to enlarge - 1494-2_18-10 Auxiliary Contacts 1 N.O. Contact 1494R Disconnect Switch
100 A, 200 A
895-A2
1 N.C. Contact 895-B2
1 N.O. and 1 N.C. Contact 895-C2
Auxiliary Contact Adapter Kit for 1 contact 895-M21
Cat. No. 895-A2 Cat. No. 895-M21 Auxiliary Contact Adapter Kit for 2 contacts 895-M22
Click to enlarge - 1495-N34_GS Electrical Interlocks 1 N.O. and 1 N.C. — early make/break 1494C, 1494G & 1494V Disconnect Switches with Left-/Right-Hand Mechanism,
30…100 A & Right-Hand Mechanism, 600 A
§  1495-N34
2 N.O. and 2 N.C. — early make/break §  1495-N35
1 N.O. and 1 N.C. — early make/break 1494C, 1494G, & 1494V Disconnect Switch with Right-Hand Mechanism,
200 A, 400 A
1495-N43
2 N.O. and 2 N.C. — early make/break 1495-N44
1 N.O. and 1 N.C. — early make/break 1494C and 1494V Disconnect Switch with Left-Hand Mechanism, 30…100 A 1495-N37
Cat. No. 1495-N34 2 N.O. and 2 N.C. — early make/break 1495-N38
Click to enlarge - 1495-N35_GS 1 N.O. and 1 N.C. — early make/break 1494V Disconnect Switch with Left-Hand Mechanism, 200 A 1495-N39
2 N.O. and 2 N.C. — early make/break 1495-N40
1 N.O. and 1 N.C. — early make/break 1494V Disconnect Switch with Left-Hand Mechanism, 400 A 1495-N41
2 N.O. and 2 N.C. — early make/break 1495-N42
10 A DPDT – early break (for 30 A, Type 1 & 3R only) 1494H Safety Switch 1495-N77
15 A DPDT – early break (for 30 A, Type 12)
15 A DPDT – early break (for all 60 A, 100 A, & 200 A, Type 1, 3R, and 12)
1495-N78
Cat. No. 1495-N35 Electrical Interlock Adapter Kit 600 A Disconnect Switch 1494C, 1494G, 1494V Disconnect Switch 1495-N36
  
⋆ Requires an adapter kit on new installations. ‡ One adapter kit enables up to two auxiliary contacts to be installed.
§ Additional adapter kit (Cat. No. 1495-N36) required for installation on 600 A switch.

Click to enlarge - 1494-2_19-1 Description For Use With Cat. No.
Lug Connectors (3 per package) 1494C, 1494F, 1494G, and 1494V Disconnect Switches  
Disconnect Size [A] Wire Size
30 #14…8 AWG Wire ⋆ 
60 #14…4 AWG Wire ♣  1494R-N1
100 #8…1/0 AWG Wire ♣  1494R-N2
200 #6…4/0 AWG Wire ♣  1494R-N3
#6…250 MCM Wire (oversized) ♣  199-LF1
400 (2) #6…250 MCM AWG
16 mm2…120 mm2
♣  1494R-N14
#4 AWG…500 MCM Wire (oversized) ♣  1494R-N15
600 (2) of #1/0…350 MCM Wire ♣  1494R-N10
(2) of #1/0…350 MCM Wire 1491-N621 or 1491-R621 600 A fuse blocks ∆  1494R-N11
Cat. No. 1494R-N3 (1) of #4…500 MCM Wire ∆  1494R-N12
Click to enlarge - 1494-2_19-2 Ground Connectors 1494C, 1494F, 1494G, and 1494V Disconnect Switches
599-GR1
Ground Lug Kits 30…100 A
200…400 A 599-GR2
600 A 599-GR3
30, 60 A 1494H & 1494HL Safety Switches 599-GR4
Cat. No. 599-GR1 100, 200 A 599-GR5
Click to enlarge - 599-NK1_GS Neutral Kits
30 A @ 250/600V AC Fusible (Type 1 & 3R)
1494H Safety Switches
599-NK1
30 A @ 250/600V AC Non-Fusible (Type 1 & 3R) 599-NK2
30 A @ 250/600V AC Fusible & Non-Fusible (Type 12) 599-NK3
60 A @ 250/600V AC Fusible & Non-Fusible (Type 1 & 3R) 599-NK4
60 A @ 250/600V AC Fusible (Type 12) 599-NK5
60 A @ 250/600V AC Non-Fusible (Type 12) 599-NK6
100 A @ 250/600V AC Fusible (Type 1 & 3R) 599-NK7
100 A @ 250/600V AC Non-Fusible (Type 1, 3R, and 12) 599-NK8
100 A @ 250/600V AC Fusible (Type 12) 599-NK9
200 A @ 250/600V AC Fusible & Non-Fusible (Type 1 & 3R) 599-NK10
200 A @ 250/600V AC Fusible & Non-Fusible (Type 12) 599-NK11
  Phase Barrier Kits 1494C, 1494F, 1494G, 1494V  
Disconnect Size [A]
30, 60 1494F-PH2
100 1494F-PH3
200 1494F-PH4
400 1494F-PH5
  
⋆ All terminals of the 30 A switches are furnished with self-lifting pressure plate connectors as standard.
∆ Each kits contains (2) lugs.
♣ Each kit contains (3) lugs.

Click to enlarge - 1494-2_19-3 Description For Use With Cat. No.
Fuse Clips (6 per package) 1494C, 1494F, 1494G, and 1494V Disconnect Switches


Fuse Class Fuse Clip Rating [A]
250V 600V
H/J 30 1401-N41
60 30 1401-N42
60 1401-N43
100 100 1401-N44
200 200 1401-N45
400 400 1401-N46
J 30 30 1494C, 1494F, 1494G, and 1494V Disconnect Switches 1401-N42
60 60 1494C, 1494F, 1494G, and 1494V Disconnect Switches 1401-N43
100 100 1494C, 1494F, 1494G, and 1494V Disconnect Switches 1401-N44
200 200 1494C, 1494F, 1494G, and 1494V Disconnect Switches 1401-N45
400 400 1494C, 1494F, 1494G, and 1494V Disconnect Switches 1401-N46
600 600 1494V-FS600 Fuse Blocks ‡ 
R 30 1494C, 1494F, 1494G, and 1494V Disconnect Switches 1401-N50
60 30 1401-N51
60 1401-N52
100 100 1401-N53
200 200 1401-N54
400 400 1401-N55
H, R 600 600 1491 Fuse Blocks § 
Click to enlarge - 1401-N70_GS Class R Fuse Clip Kits
30 A @ 250V AC (Type 1, 3R, 12)
1494H Safety Switches
1401-N70
30 A @ 600V AC (Type 1, 3R) 1401-N71
30 A @ 600V AC (Type 12) 1401-N72
60 A @ 250V AC (Type 1, 3R, 12) 1401-N73
60 A @ 600V AC (Type 1, 3R, and 12) 1401-N74
100 A @ 250/600V AC (Type 1 & 3R) 1401-N75
100 A @ 250/600V AC (Type 12) 1401-N76
100 A @ 250/600V AC (Type 1 & 3R)
200 A @ 250/600V AC (Type 1, 3R, and 12)
1401-N77
30 A @ 250V AC (Type 1 & 3R) 1494HL Safety Switches 1401-N78
60 A @ 250V AC (Type 1 & 3R) 1401-N79
100 A @ 250V AC (Type 1 & 3R) 1401-N80
100 A @ 250V AC (Type 1 & 3R)
200 A @ 250V AC (Type 1 & 3R)
1401-N81
  
§ Included with Bulletin 1491 separate mounted fuse blocks. One fuse block kit per pole required.
‡ Fuse clips not required; fuse bolts directly to terminal.

Click to enlarge - 1495_FuseCover_GS Protective Fuse Covers (for use with Bul. 1494C, 1494F, 1494G, and 1494V disconnect switches)
Switch Rating [A] Fuse Class Fuse Clip Rating [A] Cat. No.
250V 600V
30
30
60
30
60
60
100
Non-fusible
H, R
H, R
J
J
Non-fusible
Non-fusible

30
60
30
60




30
60

1495-N64
30
60
100
H, R
H, R
J


100
30
60
100
1495-N65
100
100
H, R
J
100
200
100
200
1495-N66
200
200
200
Non-fusible
H, J, R
J

200
400

200
400
♦  1495-N67
200
200
Non-fusible
H, J, R

200

200
♠  1495-N62
400
400
Non-fusible
H, J, R

400

400
♦  1495-N68
400
400
Non-fusible
H, J, R

400

400
♠  1495-N63
600
600
Non-fusible
J

600

600
♦  1495-N61
600 H, J, R 600 600 ▶  1495-N69
Click to enlarge - 1495-N_GS Protective Line Covers (for use with Bul. 1494C, 1494F, 1494G, and 1494V disconnect switches)
30, 60, 100 1495-N80
200 1495-N81
400 1495-N82
600 1495-N83
Click to enlarge - 1494R-N16_4c Terminal Lug Adapter Kit — allows two wires (maximum 8 AWG) to be installed on the line side or load side
(for use with Bul. 1494C, 1494F, 1494G, and 1494V disconnect switches)
30 1494R-N16
60 1494R-N17
100 1494R-N18
200, 400 1494R-N19
  
♦ Switch with right-hand mechanism.
♠ Switch with left-hand mechanism.
▶ Used with Bulletin 1491-N621and 1491-R621 on Bulletin 1494V/1494C/1494G.

Click to enlarge - 1494-2_21-1 Description For Use With Cat. No.
Defeater Bracket Extension Kit
For use with operating handles that do not align properly with the door catch or door hardware on enclosures with a rolled lip flange construction.
All 1494F and 1494V Handles (except 1494V-R1 and 1494V-R2) 1494V-H12
Click to enlarge - 1494-2_21-3 Channel Support Kits
For use to prevent flexing of the operating handle mounting surface. This is especially useful when the operating handle is mounted on a channel in a multi-door enclosure.
30…200 A Switches
Applies only to Operating Handle Cat. Nos. 1494F-P1, M1, and S1.
1494V-H15
Click to enlarge - 1495-N71_GS Conduit Hubs (for Type 3R enclosures)⋆ 
19.05 mm (3/4 in.) hub
30 A, 60 A, 100 A 1494H Safety Switches
1495-N71
25.4 mm (1 in.) hub 30 A, 200 A 1495-N72
31.75 mm (1-1/4 in.) hub 60 A 1495-N73
38.1 mm (1-1/2 in.) hub 100 A 1495-N74
50.8 mm (2 in.) hub 1495-N75
63.5 mm (2-1/2 in.) hub 200 A 1495-N76
Click to enlarge - 1494-2_21-5 Non-Metallic Conduit Connectors

1/2 in. (12.7 mm)
30 A 1494G Disconnect Switches 1490-N1
3/4 in. (19 mm) 30 A 1490-N9
1 in. (25.4 mm) 30 A 1490-N10
1-1/4 in. (31.75 mm) 60 A 1490-N11
1-1/2 in. (38.1 mm) 100 A 1490-N5
2 in. (50.8 mm) 200 A 1490-N6
2-1/2 in. (63.5 mm) 200 A 1490-N7
3 in. (76.2 mm) 400…600 A 1490-N8
Click to enlarge - 1494-2_21-6 Grounding Adapters

#14…10 AWG, 1/2 in. (12.7 mm)
30 A 1490-N19
#14…8 AWG, 3/4 in. (19 mm) 30 A 1490-N20
#14…8 AWG, 1 in. (24.5 mm) 30 A 1490-N21
#14…4 AWG, 1-1/4 in. (31.8 mm) 60 A 1490-N22
#8…1/0 AWG, 1-1/2 in. (38.1 mm) 100 A 1490-N23
#8…1/0 AWG, 2 in. (50.8 mm) 200 A 1490-N24
#6…2/0 AWG, 2-1/2 in. (63.5 mm) 200 A 1490-N25
#6…4/0 AWG, 3 in. (76.2 mm) 400…600 A 1490-N26
  
⋆ Packaged in quantities of 10.

Click to enlarge - 1494-2_20-1a Click to enlarge - 1494-2_20-2 Decription For Use With Cat. No.♣ 
Type 12 Door Hardware Kit Includes:
handle, cam, defeater actuator lever, rollers, and shims

Enclosure Height less than 40 in. (1016 mm)

Top and Side (Right Hand)
1494C,
All 1494V
⋆  1494V-L1
Top and Side (Left Hand) ⋆  1494V-LL1
Enclosure Height 40…60 in. (1016…1524 mm)

Top and Side (Right Hand)
Bottom
⋆  1494V-L1
and 1494V-L2
Top and Side (Left Hand)
Bottom
⋆  1494V-LL1
Cat. No. 1494V-L1 and 1494V-L2
Click to enlarge - 1494-2_20-1b Enclosure Height greater than 60 in. (1524 mm)

Top, Side, and Bottom (Right Hand)
⋆  1494V-L3
Cat. No. 1494V-L2 Cat. No. 1494V-L3 Top, Side, and Bottom (Left Hand) ⋆  1494V-LL3
Click to enlarge - 1494-2_20-3 Type 12 Door Hardware Kit Includes:
Handle, cam, defeater actuator lever, rollers, and shims

Enclosure Height less than 30 in. (762 mm)

Top and Side (Right Hand)
1494F,
1494D
⋆  1494F-L1
Top and Bottom (Right Hand) ⋆  1494F-L2
Enclosure Height 30…48 in. (762…1219 mm)

Top and Bottom (Right Hand)
Side
⋆  1494F-L2
and 1494F-L3
Cat. No. 1494F-L2 and 1494F-L3 Enclosure Height greater than 48 in. (1219 mm)

Top, Side, and Bottom (Right Hand)
‡  1494F-L4
Click to enlarge - 1494-2_20-4 Master Door Interlock Kits
Interlock kits are designed to provide interlocking between the master and auxiliary doors of the same enclosure and for use with Cat. Nos. 1494F-L4 hardware kits or Cat. No. 1494V-L3 hardware kits. Specify one master door kit and as many auxiliary door kits as necessary (9 maximum). Connecting bars must be supplied by user.
1494C,
1494F,
1494D,
1494V
§  1494F-N20
Cat. No. 1494F-N20 Auxiliary Door Interlock Kit 1494F-N21
  
⋆ Door hardware kit does not include rectangular connecting bars (1/4 x 1/2 in.). To be provided by customer.
‡ Door hardware kit does not include rectangular connecting bars (1/4 x 5/8 in.). To be provided by customer.
§ Master door interlock kit does not include rectangular connecting bars (3/8 x 3/8 in.). To be provided by customer.
♣ If the Rockwell Automation door hardware kits are to be installed in a commercially available enclosure, consult the enclosure manufacturer's application data for proper kit selection.

Bulletin 1494C, 1494F, 1494G, 1494R, 1494V Disconnect Switches

Disconnect Switch Electrical Ratings
Switch Size 30 A 60 A 100 A 200 A 400 A 600 A
Rated insulation voltage Ui (UL) IEC (600) 660V
Ratings
UL/CSA/NEMA
Hp 230V/60 Hz
460V/60 Hz
575V/60 Hz
7.5
15
20
15
30
50
30
60
75
60
125
150
125
250
350
200
400
500
250V DC 5 10 20 40 50 50
Continuous
Current
600V AC
250V DC
30 60 100 200 400 600
Ratings
IEC Applications
Maximum kW
(AC23)
220V/50 Hz
440V/50 Hz
550V/50 Hz
5.5
11
15
11
22
37
22
45
55
48
90
110
90
185
257
150
295
375
Auxiliary Contact Electical Ratings
NEMA/EEMAC B600, P300
IEC Ratings Ui    660V Ith 10 A  


ACII    Ux
12…120V
220…240V
380…400V
500…600V


Ie
6 A
3 A
1.5 A
1.2 A
Low level switching 5 mA @ 12V DC
Mechanical
Degree of protection Operating handles Non-metallic Type 1, 3R, 4, 4X, 12,
Painted Type 1, 3R, 4, 12
Stainless steel Type 4, 4X
Mechanical life (Typical) 20 000 operations (30…200 A)
10 000 operations (400…600 A)
Switching frequency (operations/hr) 30, 60, 100, and 200 A sizes — 300 max.
400 and 600 A sizes — 240 max.
Environmental
Temperature Operating -35…+40 °C (-31…+104 °F)
Storage -40…+65 °C (-40…+149 °F)
Altitude (per IEC 947-5) 2000 m per IEC 337-1
Relative Humidity (per IEC 947-3) 90% at 20 °C (68 °F) and 50% at 40 °C (104 °F)
Design Specification/Test Requirements
Dielectric strength 2200V for 1 minute
Electrical life 6000 operations at rated current
Short Circuit Withstand Capability 10 000 A: unfused
10 000 A: with Class H fuses
200 000 A: with Class J or Class R fuses
Construction
Switch body material Phenolic
Contact material Copper, tin-plated
Terminals 30 A
60 A
100 A
200 A
400 A
600 A
#10 - 32 screw and self-lifting pressure plate
1/4 in. - 28 screw-lug, copper
5/16 in. - 24 screw-lug, copper
3/8 in. - 24 screw-lug, copper
3/8 in. - 24 screw-lug, copper
1/2 in. - 13 screw-lug, copper
All wire rated 75 °C (167 °F) or higher must be sized per the local Electric Code for 75 °C (167 °F) wire.
Conductor Size (mm2) 30 A
60 A
100 A
200 A
400 A
600 A
#14…8 AWG (1.5…10 mm2)
#14…4 AWG (2.5…16 mm2)
#8…1/0 AWG (10…50 mm2)
#6…4/0 AWG (16…95 mm2)
2 of #1/0 AWG…250 MCM (2 per lug) 2 of 185 mm2…250 MCM or (1) #4 AWG…500 MCM
2 of #1/0 AWG…350 MCM (2 per lug) 2 of 185 mm2…350 MCM or (1) #4 AWG…500 MCM
Recommended Torque
30 A
60 A
100 A
200 A
400 A
600 A
Conductor into Lug
20 lbin
45 lbin
150 lbin
275 lbin
325 lbin
325 lbin
Lug to Terminal
20 lbin
50 lbin
90 lbin
175 lbin
175 lbin
275 lbin
Switches, Mechanisms, and Accessory Kits Zinc-plated steel, RoHS Compliant finish
  

Bulletin 1494H, 1494HL Disconnect Switches

Disconnect Switch Electrical Ratings
Switch Size 30 A 60 A 100 A 200 A
Rated insulation voltage Ui (UL) IEC (600) 660V
Ratings
UL/CSA/NEMA
Hp 230V/60 Hz
460V/60 Hz
575V/60 Hz
10
20
30
20
50
60
40
75
100
60
125
150
250V DC 5 10 20 40
Continuous
Current
600V AC
250V DC
30 60 100 200
Auxiliary Contact Electical Ratings
Continuous Current 10 A 15 A
Pole Configuration DPDT DPDT
Mechanical
Degree of protection Operating handles Painted Type 1, 3R, 12
Mechanical life (Typical) 10 000 operations
Switching frequency (operations/hr) 300 maximum
Environmental
Temperature Operating -35…+40 °C (-31…+104 °F)
Storage -40…+65 °C (-40…+149 °F)
Altitude (per IEC 947-5) 2000 m per IEC 337-1
Relative Humidity (per IEC 947-3) 90% at 20 °C (68 °F) and 50% at 40 °C (104 °F)
Design Specification/Test Requirements
Dielectric strength 2200V for 1 minute
Electrical life 6000 operations at rated current
Short Circuit Withstand Capability 10 000 A: unfused
10 000 A: with Class H fuses
200 000 A: with Class J or Class R fuses (30…100 A)
100 000 A: with Class J or Class R fuses (200 A)
Construction
Switch body material Phenolic
Contact material Copper, tin-plated
Terminals 30 A
60 A
100 A
200 A
#10 - 32 screw and self-lifting pressure plate
1/4 in. - 28 screw-lug, copper
5/16 in. - 24 screw-lug, copper
3/8 in. - 24 screw-lug, copper
All wire rated 75 °C (167 °F) or higher must be sized per the local Electric Code for 75 °C (167 °F) wire.
Conductor Size (mm2) 30 A
60 A
100 A
200 A
#14…8 AWG
#12…2 AWG
#10…1/0 AWG
#2…250 MCM AWG
Recommended Torque
30 A
60 A
100 A
200 A
Conductor into Lug
36…40 lbin
35…45 lbin
35…50 lbin
275 lbin
Mechanisms Zinc-plated steel, bronze chromate finish
  

Bulletin 1494D, 1494V Circuit Breakers

Electrical Ratings
Frame Size 125 A 150 A 250 A 400 A 600 A 800 A 1200 A
Auxiliary Contacts
1494V, 1494D
NEMA/EEMAC B600, P300
IEC Ratings

ACII    Ux
12…120V
220…240V
380…400V
500…600V


Ie
6 A
3 A
1.5 A
1.2 A
Maximum Number of Auxiliary Contacts 2
Mechanical Data
Mechanical Life (Typical) 10 000
Construction
Mechanisms Zinc-plated steel
Environmental Data
Ambient Temperature⋆  Operating -20…+40 °C (-4…+104 °F)
Storage -40…+65 °C (-40…+149 °F)
Altitude (per IEC 947-5) 2000 m per IEC 337-1
Relative Humidity (per IEC 947-3) 90% at 20 °C (68 °F) and 50% at 40 °C (104 °F)
  
⋆ Refer to circuit breaker specifications for other limitations.

Bulletin 1491 Fuse Blocks

Electrical
UL Fuse Type Class H Class J Class R Class C Class CC
Maximum Fuse Cartridge Size 30…600 A 30…600 A 30…600 A 30…600 A 30 A
Maximum Voltage AC 600V 600V 600V 600V 600V
DC 250V 250V 250V 250V 250V
Thermal Current Rating 30…600 A 30…600 A 30…600 A 30…600 A 30 A
Maximum Short Circuit Prospective Fault Current 10 kA 200 kA 200 kA 100 kA 200 kA
Construction
Fuse Clips Tin-plated copper
Terminals Tin-plated copper
Fuse Block Base Phenolic or porcelain
Environmental
Ambient Temperature Open -20…+55 °C (-4…+131 °F)
Enclosed -20…+40 °C (-4…+104 °F)
Storage -40…+65 °C (-40…+149 °F)
Altitude (per IEC 947-5) 2000 m
Relative Humidity (per IEC 947-3) 90% at 20 °C (68 °F) and 50% at 40 °C (104 °F)
  

Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

Bulletin 1494V

Click to enlarge - 1494-2_24-1


Click to enlarge - 1494-2_24-2
Bulletin 1494V — 30…200 A


Click to enlarge - 1494-2_24-3
Bulletin 1494V — 400…600 A


Disconnect Switches⋆ 

NEMA Size
[A]
A B‡  C D E F Switch Mounting Hole Diameter
Max. Min. Max.
30 6-19/64
(160)
7-31/32
(202)
8-1/2
(216)
21-5/8
(549)
2-3/4
(69.9)
7-9/16
(192)
3-7/8
(98.5)
7/32 in.
60 6-19/64
(160)
8-15/32
(215)
8-1/2
(216)
21-5/8
(549)
2-9/16
(65.1)
7-9/16
(192)
3-7/8
(98.5)
7/32 in.
100 6-19/64
(160)
9-1/8
(231.8)
8-1/2
(216)
21-5/8
(549)
3-37/64
(90.9)
7-9/16
(192)
3-7/8
(98.5)
7/32 in.
200 8-5/64
(205.2)
15-9/64
(384.5)
9-1/2
(241.3)
21-5/8
(549)
6-35/64
(166.3)
8-25/32
(223)
4-21/32
(118)
19/64 in.
400 11
(279.4)
18-7/32
(462.7)
10-1/2
(266.7)
21-5/8
(549)
8
(203.2)
10
(254)
5-1/2
(139.7)
11/32 in.
600 15-23/32
(399.2)
17-19/32
(446.8)§ 
10-1/2
(266.7)
21-5/8
(549)
12
(304.8)
11-27/32
(300.8)
8-51/64
(223.3)
11/32 in.
  
⋆ Approximate dimensions are for reference only.
‡ This approximate dimension will vary by fuse class and size.
§ Approximate dimension with Class J fuses.

Circuit Breakers♣ 

Frame A C D E F
Min. Max.
125A
140U-H, 140M-H, EF, HMCPE
150A
140U-I, 140M-I
EHD, FD, FDB, FDC, HFD, HMCP
6
(152.4)
6-3/4
(171.5)
23
(584.2)
6
(152.4)
5-7/16
(138.1)
5
(127)
250A
140U-J, 140M-J
250A
JD, JDB, JDC, HJD, HMCP
11-1/4
(285.8)
7-7/8
(200.0)
22-9/16
(573.1)
10
(254)
5-23/32
(145.2)
9-23/32
(246.8)
400 A
140U-K, 140M-K
KD, KDB, KDC, HKD, HMCP
600 A
140U-L
11-3/8
(228.9)
7-7/8
(200.0)
22-9/16
(573.1)
12
(304.8)
7-1/8
(181.0)
9-21/32
(245.3)
  
♣ Approximate dimensions are for reference only.

Bulletin 1494C

Click to enlarge - 1494C_dim


Disconnect Switches

NEMA Size
[A]
AA BB CC DD EE
Mounting Plate Hole Diameter
FF
Minimum Bevel Diameter
30 2-1/4
(57.2)
5-1/4
(133.4)
2-1/4
(57.2)
11/64
(4.37)
12
(304.8)
60 2-1/4
(57.2)
5-1/4
(133.4)
2-1/4
(57.2)
11/64
(4.37)
12
(304.8)
100 2-1/4
(57.2)
5-1/4
(133.4)
2-1/4
(57.2)
11/64
(4.37)
12
(304.8)
200 2
(50.8)
8-1/4
(209.6)
4-1/4
(108)
1-1/8
(28.6)
7/32
(5.56)
16
(406.4)
400 2
(50.8)
11
(279.4)
4-3/4
(120.7)
1-3/8
(34.9)
9/32
(7.14)
16
(406.4)
600 8-1/4
(209.6)
15
(381)
8-1/4
(209.6)
16
(406.4)
  

Bulletin 1494F Disconnect Switches

Non-Fusible Disconnect Switch

Click to enlarge - 1494F_nonfuse_dim


Fusible Disconnect Switch

Click to enlarge - 1494F_fuse_dim


Switch Size [A] A B C D E F G H J K L M N P Q R
30 9-3/16
(233.4)
4-5/16
(109.5)
1-1/8
(28.6)
6
(152.4)
3/8
(9.5)
1-9/16
(39.7)
10-1/2
(266.7)
8-1/2
(215.9)
6-7/8
(174.6)
8
(203.2)
8-1/2
(215.9)
15/16
(23.8)
3-21/32
(92.9)
7-5/16
(185.7)
3
(76.2)
5-7/16
(138.1)
60 9-3/16
(233.4)
4-5/16
(109.5)
1-1/8
(28.6)
6
(152.4)
3/8
(9.5)
1-9/16
(39.7)
10-1/2
(266.7)
8-1/2
(215.9)
6-7/8
(174.6)
8
(203.2)
8-1/2
(215.9)
15/16
(23.8)
3-21/32
(92.9)
7-5/16
(185.7)
3
(76.2)
5-7/16
(138.1)
100 9-3/16
(233.4)
4-5/16
(109.5)
1-1/8
(28.6)
6
(152.4)
3/8
(9.5)
1-9/16
(39.7)
10-1/2
(266.7)
9-3/4
(247.7)
8-1/8
(206.4)
8
(203.2)
8-1/2
(215.9)
15/16
(23.8)
3-21/32
(92.9)
7-5/16
(185.7)
3
(76.2)
5-7/16
(138.1)
200 9-5/8
(244.5)
4-3/4
(120.7)
1-5/32
(29.4)
8-3/16
(208)
7/16
(11.1)
2
(50.8)
10-29/32
(277)
9-3/4
(247.7)
8-1/8
(206.4)
8
(203.2)
8-1/2
(215.9)
1-5/16
(33.3)
3-3/4
(95.3)
7-1/2
(190.5)
3
(76.2)
5-7/16
(138.1)
  

Bulletin 1494F Disconnect Switches Vault Hardware Latching (Non Pre-drilled Enclosures)

Click to enlarge - 1494F_vaulthardware_dim


Vault Hardware Kits⋆  Switch Size [A] A B C
(Min.)
D E
(Min.)
F G
(Min.)
H
(Min.)
J
(Min.)
K L M N
Small and Intermediate Enclosures
1494F-L1
1494F-L2
1494F-L3
30 3-7/8
(98.4)
3/8
(9.5)
3-1/16
(77.8)
2-1/8
(54)
4-1/2
(114.3)
3-13/16
(96.8)
13
(330.2)
8-1/8
(206.4)
5
(127)
1/2
(12.7)
1/4
(6.4)
11/16
(17.5)
1/2
(12.7)
60 14
(355.6)
100 18-7/8
(479.4)
200 23-25/32
(604)
Large Enclosures
1494F-L4 30 4
(101.6)
1/2
(12.7)
3-3/4
(95.3)
2-1/8
(54)
5
(127)
3-13/16
(96.8)
13-1/8
(333.4)
9-13/16
(249.2)
6
(152.4)
5/8
(15.9)
5/16
(7.9)
1-1/4
(31.8)
3/4
(19.1)
60 13-5/8
(346.1)
100 18-1/2
(469.9)
200 23-13/32
(594.5)
  

Bulletin 1494D Circuit Breakers♣ 

Click to enlarge - 1494-2_25-1


Click to enlarge - 1494-2_25-2


Cutler-Hammer Frame A C D E F
Min. Max.
150 A — EHD, FD, FDB, FDC, HFD, HMCP 7-13/16 (198.4) 6-3/8 (161.9) 6 (152.4) 5-5/8 (142.9) 6-7/16 (163.5)
250 A — JD, JDB, JDC, HJD, HMCP 11-1/2 (292.1) 8-3/8 (212.7) 8 (203.2) 5-13/16 (147.6) 9-7/16 (239.7)
400 A — KD, KDB, KDC, HKD, HMCP 11-1/2 (292.1) 8-3/8 (212.7) 12 (304.8) 6-7/8 (174.6) 9-7/16 (239.7)
600 A — LD, HLD, LDC, LA, HLA, LC, HLC 11-3/8 (288.9) 9-1/2 (241.3) 8 (203.2) 12 (304.8) 10-17/32 (267.5)
800 A — MA, MDL, HMDL, HMA, MC, ND, HND, NDC 16 (406.4) 9-1/2 (241.3) 10 (254) 12-5/16 (312.7) 15-3/32 (183.4)
1200 A — NB TRI-PAK 22 (558.8) 9-1/2 (241.3) 10 (254) 12-5/16 (312.7) 21-3/32 (535.8)
1200 A — HNC, ND, HND, NDC, NB, HNB, NC, HNC 16 (406.4) 9-1/2 (241.3) 12 (304.8) 12-5/16 (312.7) 25-3/32 (183.4)
  
♣ Approximate dimensions are for reference only.

Bulletin 1494G, 1494GX, 1494GY Enclosed Disconnect Safety Switches

Type 3R/4/12 (Enclosure Code "F") Painted Metal Enclosures

Click to enlarge - 1494-2_26-1


Size [A] Fuse
Style⋆ 
Number
of Poles
Bulletin
No.
Approximate Dimensions in Inches (Millimeters) Approx.
Shipping
Weight
[lb (kg)]
A
Height
B
Width
C
Depth
D
Mounting
E
Mounting
F
Mounting
G
Handle
Depth
H J
30 A 2 or 3 1494G 13-5/16
(338)
10-1/2
(267)
8-1/4
(210)
14-11/16
(373)
‡  5-1/4
(133)
5-9/16
(141)
15-21/32
(398)
11/32
(9)
20
(9.07)
60
30 B 2 or 3 1494G 20
(509)
10-1/2
(267)
10-3/16
(259)
21-7/16
(545)
‡  5-1/4
(133)
5-9/16
(141)
22-13/32
(569)
11/32
(9)
30
(13.6)
60
100 A
30 C 6 1494G 27-1/2
(698)
10-1/2
(267)
8-1/4
(210)
28-7/8
(733)
‡  5-1/4
(133)
5-9/16
(141)
29-7/8
(759)
13/16
(21)
60
(27.21)
D
60 C
D
30 A 2 or 3 1494GY
B
60 A
B
30 A 2 or 3 1494GX 30
(762)
20-1/2
(521)
10-3/16
(259)
31-3/8
(797)
15-1/4
(387)
15-1/4
(387)
5-9/16
(141)
32-3/8
(822)
13/16
(21)
90
(40.82)
B
60 A
B
100 D 6 1494G
100 A 2 or 3 1494GY
B
100 B 2 or 3 1494G 31-1/2
(800)
10-1/2
(267)
10-3/32
(257)
32-7/8
(835)
‡  5-1/4
(133)
5-9/16
(141)
33-27/32
(860)
11/32
(9)
70
(31.73)
C 6
200 A 2 or 3
B
100 A 2 or 3 1494GX 50
(1270)
22
(559)
11-1/2
(292)
51-3/8
(1305)
15-1/4
(387)
15-1/4
(387)
5-9/16
(141)
52-11/32
(1330)
11/32
(9)
200
(90.7)
B
200 C 6 1494G
D
200 A 2 or 3 1494GY
B
400 A 2 or 3 1494G 50
(1270)
22
(559)
11-1/2
(292)
51-3/8
(1305)
15-1/4
(387)
15-1/4
(387)
7-5/8
(194)
52-11/32
(1330)
11/32
(9)
200
(90.7)
600 A
400 B 2 or 3 1494G 56
(1422)
30-1/2
(775)
13-51/64
(350)
57-5/8
(1464)
20
(508)
25-1/4
(641)
7-5/8
(194)
62-5/8
(1590)
1
(25.4)
300
(136.05)
600 B
  
⋆ A = Non-Fusible, Fusible 250V - Class H/R, Fusible 600V - Class J
B = Fusible 600V - Class H/R
C = Non-fusible
D = Fusible 250V - Class H/R, Fusible 600V - Class J
‡ These enclosures have one top mounting hole located on the center line. All other enclosures have two top mounting holes located as shown.

Bulletin 1494G, 1494GX, 1494GY Enclosed Disconnect Safety Switches

Type 4/4X (Enclosure Code "C") Stainless Steel Enclosure

Click to enlarge - 1494-2_27-1


Size [A] Fuse
Style⋆ 
Number
of Poles
Bulletin
No.
Approximate Dimensions in Inches (Millimeters) Approx.
Shipping
Weight
[lb (kg)]
A
Height
B
Width
C
Depth
D
Mounting
E
Mounting
F
Mounting
G
Handle
Depth
H J
30 A 2 or 3 1494G 13-5/16
(338)
10-1/2
(267)
8-9/16
(217)
14-11/16
(373)
‡  5-1/4
(133)
5-9/16
(141)
15-21/32
(398)
13/16
(21)
20
(9.07)
60
30 B 2 or 3 1494G 27-1/2
(698)
10-1/2
(267)
8-1/4
(210)
28-7/8
(733)
‡  7
(178)
5-9/16
(141)
29-3/4
(756)
13/16
(21)
60
(27.21)
C 6
D
60 B 2 or 3
C 6
D
30 A 2 or 3 1494GY
B
60 A
B
30 A 2 or 3 1494GX 30
(762)
20-1/2
(521)
9-7/8
(251)
31-3/8
(797)
17
(432)
17
(432)
5-9/16
(141)
32-1/4
(819)
13/16
(21)
90
(40.82)
B
60 A
B
100 A 2 or 3 1494G
B
C 6
D
100 A 2 or 3 1494GX 50
(1270)
22
(559)
11-3/16
(284)
51-3/8
(1305)
18-1/2
(470)
18-1/2
(470)
5-9/16
(141)
52-1/4
(1327)
13/16
(21)
200
(90.7)
B
200 A 2 or 3 1494G
B
C 6
D
400 A 2 or 3 1494G 56
(1422)
30-1/2
(775)
13-51/64
(350)
57-5/8
(1464)
20
(508)
25-1/4
(641)
7-5/8
(194)
58-5/8
(1489)
1
(25.4)
300
(136.05)
B
600 A
B
  
⋆ A = Non-Fusible, Fusible 250V - Class H/R, Fusible 600V - Class J
B = Fusible 600V - Class H/R
C = Non-fusible
D = Fusible 250V - Class H/R, Fusible 600V - Class J
‡ These enclosures have one top mounting hole located on the center line. All other enclosures have two top mounting holes located as shown.

Bulletin 1494H Heavy Duty Safety Switches

Type 1 (Enclosure Code "A") General Purpose Painted Metal Enclosures

Click to enlarge - 1494H_Type 1_Dims


Switch Size [A] Fuse Style A
Height
B
Width
C
Depth
D
Width (with handle)
Knockout Fig. #
30 240V 10-9/32 (261.1) 6-3/8 (162.1) 3-5/16 (84.1) 7-1/8 (181) 1
600V 12-19/32 (319.8) 8-3/8 (212.9) 4 (101.6) 9-1/2 (241.3) 2
Non-fusible 10-3/8 (263.7) 8-3/8 (212.9) 4 (101.6) 9-1/4 (235) 3
60 240V 17-19/32 (446.8) 9-3/8 (238.3) 5 (127) 10-3/64 (255.3) 4
600V 21-11/32 (542) 5
Non-fusible 17-19/32 (446.8) 4
100 240V 21-11/32 (542) 9-3/8 (238.3) 5 (127) 10-3/64 (255.3) 5
600V 22-11/32 (567.4) 4
Non-fusible 17-19/32 (446.8) 4
200 240V 31-5/8 (803.3) 13-7/16 (341.4) 5-1/4 (133.4) 14-7/16 (366) 6
600V
Non-fusible
  

Knockouts — Conduit Size

Click to enlarge - 1494H_KO_Fig1   Click to enlarge - 1494H_KO_Fig2   Click to enlarge - 1494H_KO_Fig3
Fig. 1 Fig. 2 Fig. 3
 
Click to enlarge - 1494H_KO_Fig4   Click to enlarge - 1494H_KO_Fig5   Click to enlarge - 1494H_KO_Fig6
Fig. 4 Fig. 5 Fig. 6

Switch Size [A] Fuse Style Knockouts
A B C D E
30 240V 9/32 (7.1) 1/2 x 3/4
(12.7 x 19.1)
3/8 x 1/2 x 3/4 x 1
(9.5 x 12.7 x 19.1 x 25.4)
600V 1/2 x 3/4 x 1
(12.7 x 19.1 x 25.4)
1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
Non-fusible
60 240V 9/32 (7.1) 1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
1 x 1-1/4 x 1-1/2 x 2
(25.4 x 31.8 x 38.1 x 50.8)
600V
Non-fusible
100 240V 9/32 (7.1) 1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
1 x 1-1/4 x 1-1/2 x 2
(25.4 x 31.8 x 38.1 x 50.8)
600V
Non-fusible
200 240V 1 x 1-1/2 x 2 x 2-1/2
(25.4 x 38.1 x 50.8 x 63.5)
9/32 (7.1) 1/2
(12.7)
600V
Non-fusible
  

Bulletin 1494H Heavy Duty Safety Switches

Type 3R (Enclosure Code "N") Rain-Proof Painted Metal Enclosures

Click to enlarge - 1494H_Type 3R_Dims


Switch Size [A] Fuse Style A
Height
B
Width
C
Depth
D
Width (with handle)
Knockout Fig. #
30 240V 10-5/8 (269.9) 6-3/8 (162.1) 3-5/16 (84.1) 7-1/8 (181) 7
600V 13-13/64 (335.3) 8-3/8 (212.9) 4 (101.6) 9-13/32 (239) 8
Non-fusible 13-13/64 (335.3) 8-3/8 (212.9) 4 (101.6) 9-13/32 (239) 8
60 240V 17-7/16 (443) 9-3/8 (238.3) 5 (127) 10-3/64 (255.3) 9
600V 22-3/16 (563.6) 10-1/2 (267)
Non-fusible 17-7/16 (443) 10-3/64 (255.3)
100 240V 22-3/16 (563.6) 9-3/8 (238.3) 5 (127) 10-1/2 (267) 9
600V 22-3/16 (563.6)
Non-fusible 17-7/16 (443) 10-3/64 (255.3)
200 240V 31-7/16 (798.6) 13-3/8 (339.9) 5-15/32 (138.9) 14-1/8 (361.9) 10
600V
Non-fusible
  

Knockouts — Conduit Size

Click to enlarge - 1494H_KO_Fig7   Click to enlarge - 1494H_KO_Fig8   Click to enlarge - 1494H_KO_Fig9   Click to enlarge - 1494H_KO_Fig10
Fig. 7 Fig. 8 Fig. 9 Fig. 10

Switch Size [A] Fuse Style Knockouts
A B C D
30 240V 9/32 (7.1) 1/2 x 3/4
(12.7 x 19.1)
3/8 x 1/2 x 3/4 x 1
(9.5 x 12.7 x 19.1 x 25.4)
600V 1/2 x 3/4 x 1
(12.7 x 19.1 x 25.4)
1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
Non-fusible
60 240V 9/32 (7.1) 1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
1 x 1-1/4 x 1-1/2 x 2
(25.4 x 31.8 x 38.1 x 50.8)
600V
Non-fusible
100 240V 9/32 (7.1) 1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
1 x 1-1/4 x 1-1/2 x 2
(25.4 x 31.8 x 38.1 x 50.8)
600V
Non-fusible
200 240V 1 x 1-1/2 x 2 x 2-1/2
(25.4 x 38.1 x 50.8 x 63.5)
9/32 (7.1) 1/2
(12.7)
600V
Non-fusible
  

Bulletin 1494H Heavy Duty Safety Switches

Type 12 (Enclosure Code "F") Dust-Tight Painted Metal Enclosures

Click to enlarge - 1494H_Type 12_Dims


Switch Size [A] Fuse Style A
Height
B
Width
C
Depth
D
Width (with handle)
30 240V 11-3/8 (288.9) 7-3/8 (187.3) 5-1/16 (128.6) 8-1/8 (206.4)
600V 13-3/8 (339.7) 9-3/8 (238.1) 5-5/16 (134.9) 10-1/4 (260.4)
Non-fusible 5-1/16 (128.6)
60 240V 19-3/8 (492.1) 9-3/8 (238.1) 5-1/16 (128.6) 10-1/4 (260.4)
600V 5-5/16 (134.9)
Non-fusible 5-1/16 (128.6)
100 240V 25-3/8 (644.5) 13-1/2 (342.9) 5-1/16 (128.6) 14-1/4 (362)
600V 5-5/16 (134.9)
Non-fusible
200 240V 35-1/8 (892.2) 13-1/2 (342.9) 5-5/16 (134.9) 15-1/4 (387.4)
600V 14-1/2 (368.3)
Non-fusible
  

Bulletin 1494HL General Duty Safety Switches

Type 1 (Enclosure Code "A") General Purpose Painted Metal Enclosures

Click to enlarge - 1494H_Type 1_Dims


Switch Size [A] Fuse Style A
Height
B
Width
C
Depth
D
Width (with handle)
Knockout Fig. #
30 240V 10-9/32 (261.1) 6-1/2 (165.1) 3-5/16 (84.1) 6-29/32 (175.3) 1
60 13-27/32 (351.5) 8-1/2 (215.9) 4 (101.6) 8-7/8 (225.6) 2
100 21-11/32 (542) 9-1/2 (241.3) 5 (127) 9-7/8 (251) 3
200 29-1/8 (739.6) 13-7/16 (341.4) 5-5/16 (134.9) 13-15/16 (354.1) 4
  

Knockouts — Conduit Size

Click to enlarge - 1494HL_KO_Fig1   Click to enlarge - 1494HL_KO_Fig2   Click to enlarge - 1494HL_KO_Fig3   Click to enlarge - 1494HL_KO_Fig4
Fig. 1 Fig. 2 Fig. 3 Fig. 4

Switch Size [A] Knockouts
A B C D E
30 9/32 (7.1) 1/2 x 3/4
(12.7 x 19.1)
3/8 x 1/2 x 3/4 x 1
(9.5 x 12.7 x 19.1 x 25.4)
60 9/32 (7.1) 1/2 x 3/4
(12.7 x 19.1)
1/2 x 3/4 x 1
(12.7 x 19.1 x 25.4)
1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
100 9/32 (7.1) 1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
1 x 1-1/4 x 1-1/2 x 2
(25.4 x 31.8 x 38.1 x 50.8)
200 1/2 (12.7) 1 x 1-1/2 x 2 x 2-1/2
(25.4 x 38.1 x 50.8 x 63.5)
9/32 (7.1)
  

Type 3R (Enclosure Code "N") Rain-Proof Painted Metal Enclosures

Click to enlarge - 1494H_Type 3R_Dims


Switch Size [A] Fuse Style A
Height
B
Width
C
Depth
D
Width (with handle)
Knockout Fig. #
30 240V 10-1/32 (254.8) 6-3/8 (162.1) 3-5/16 (84.1) 7-1/8 (180.8) 5
60 13-15/16 (353.8) 8-3/8 (212.9) 3-7/8 (225.6) 9-3/32 (230.9) 6
100 21-7/16 (544.3) 9-3/8 (238.3) 5 (127) 9-61/64 (252.7) 7
200 28-15/16 (735.1) 13-3/8 (339.9) 5-5/16 (134.9) 14-1/16 (357.1) 8
  

Knockouts — Conduit Size

Click to enlarge - 1494HL_KO_Fig5   Click to enlarge - 1494HL_KO_Fig6   Click to enlarge - 1494HL_KO_Fig7   Click to enlarge - 1494HL_KO_Fig8
Fig. 5 Fig. 6 Fig. 7 Fig. 8

Switch Size [A] Knockouts
A B C D
30 9/32 (7.1) 1/2 x 3/4
(12.7 x 19.1)
3/8 x 1/2 x 3/4 x 1
(9.5 x 12.7 x 19.1 x 25.4)
60 9/32 (7.1) 1/2 x 3/4 x 1
(12.7 x 19.1 x 25.4)
1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
100 9/32 (7.1) 1/2 x 3/4 x 1 x 1-1/4
(12.7 x 19.1 x 25.4 x 31.8)
3/4 x 1 x 1-1/4 x 1-1/2
(19.1 x 25.4 x 31.8 x 38.1)
1 x 1-1/4 x 1-1/2 x 2
(25.4 x 31.8 x 38.1 x 50.8)
200 1/2 (12.7) 1 x 1-1/2 x 2 x 2-1/2
(25.4 x 38.1 x 50.8 x 63.5)
1 x 1-1/2 x 2 x 2-1/2
(25.4 x 38.1 x 50.8 x 63.5)