Catalogs > Industrial Controls Catalog > Motor Control, NEMA > Disconnect Switches > Safety Switches > Bulletin 1494G/1494GX/1494GY Safety Switches — Heavy Industrial > 600V, Fusible with Class H Fuse Clips
600V, Fusible with Class H Fuse Clips
| Introduction | Standards Compliance and Certifications | Cat. No. Explanation | Product Selection |
| Modifications | Accessories | Specifications | Approximate Dimensions |
Bulletin 1494V
|
|
|
Disconnect Switches⋆
| NEMA Size [A] |
A | B | C | D | E | F | Switch Mounting Hole Diameter | |
| Max. | Min. | Max. | ||||||
| 30 | 6-19/64 (160) |
7-31/32 (202) |
8-1/2 (216) |
21-5/8 (549) |
2-3/4 (69.9) |
7-9/16 (192) |
3-7/8 (98.5) |
7/32 in. |
| 60 | 6-19/64 (160) |
8-15/32 (215) |
8-1/2 (216) |
21-5/8 (549) |
2-9/16 (65.1) |
7-9/16 (192) |
3-7/8 (98.5) |
7/32 in. |
| 100 | 6-19/64 (160) |
9-1/8 (231.8) |
8-1/2 (216) |
21-5/8 (549) |
3-37/64 (90.9) |
7-9/16 (192) |
3-7/8 (98.5) |
7/32 in. |
| 200 | 8-5/64 (205.2) |
15-9/64 (384.5) |
9-1/2 (241.3) |
21-5/8 (549) |
6-35/64 (166.3) |
8-25/32 (223) |
4-21/32 (118) |
19/64 in. |
| 400 | 11 (279.4) |
18-7/32 (462.7) |
10-1/2 (266.7) |
21-5/8 (549) |
8 (203.2) |
10 (254) |
5-1/2 (139.7) |
11/32 in. |
| 600 | 15-23/32 (399.2) |
17-19/32 (446.8)§ |
10-1/2 (266.7) |
21-5/8 (549) |
12 (304.8) |
11-27/32 (300.8) |
8-51/64 (223.3) |
11/32 in. |
| ⋆ Approximate dimensions are for reference only. | ||||||||
| This approximate dimension will vary by fuse class and size. | ||||||||
| § Approximate dimension with Class J fuses. | ||||||||
Circuit Breakers♣
| Frame | A | C | D | E | F | |
| Min. | Max. | |||||
| 125A 140U-H, 140M-H, EF, HMCPE 150A 140U-I, 140M-I EHD, FD, FDB, FDC, HFD, HMCP |
6 (152.4) |
6-3/4 (171.5) |
23 (584.2) |
6 (152.4) |
5-7/16 (138.1) |
5 (127) |
| 250A 140U-J, 140M-J 250A JD, JDB, JDC, HJD, HMCP |
11-1/4 (285.8) |
7-7/8 (200.0) |
22-9/16 (573.1) |
10 (254) |
5-23/32 (145.2) |
9-23/32 (246.8) |
| 400 A 140U-K, 140M-K KD, KDB, KDC, HKD, HMCP 600 A 140U-L |
11-3/8 (228.9) |
7-7/8 (200.0) |
22-9/16 (573.1) |
12 (304.8) |
7-1/8 (181.0) |
9-21/32 (245.3) |
| ♣ Approximate dimensions are for reference only. | ||||||
Bulletin 1494C
|
Disconnect Switches
| NEMA Size [A] |
AA | BB | CC | DD | EE Mounting Plate Hole Diameter |
FF Minimum Bevel Diameter |
| 30 | 2-1/4 (57.2) |
5-1/4 (133.4) |
2-1/4 (57.2) |
— | 11/64 (4.37) |
12 (304.8) |
| 60 | 2-1/4 (57.2) |
5-1/4 (133.4) |
2-1/4 (57.2) |
— | 11/64 (4.37) |
12 (304.8) |
| 100 | 2-1/4 (57.2) |
5-1/4 (133.4) |
2-1/4 (57.2) |
— | 11/64 (4.37) |
12 (304.8) |
| 200 | 2 (50.8) |
8-1/4 (209.6) |
4-1/4 (108) |
1-1/8 (28.6) |
7/32 (5.56) |
16 (406.4) |
| 400 | 2 (50.8) |
11 (279.4) |
4-3/4 (120.7) |
1-3/8 (34.9) |
9/32 (7.14) |
16 (406.4) |
| 600 | 8-1/4 (209.6) |
15 (381) |
8-1/4 (209.6) |
— | — | 16 (406.4) |
Bulletin 1494F Disconnect Switches
Non-Fusible Disconnect Switch
|
Fusible Disconnect Switch
|
| Switch Size [A] | A | B | C | D | E | F | G | H | J | K | L | M | N | P | Q | R |
| 30 | 9-3/16 (233.4) |
4-5/16 (109.5) |
1-1/8 (28.6) |
6 (152.4) |
3/8 (9.5) |
1-9/16 (39.7) |
10-1/2 (266.7) |
8-1/2 (215.9) |
6-7/8 (174.6) |
8 (203.2) |
8-1/2 (215.9) |
15/16 (23.8) |
3-21/32 (92.9) |
7-5/16 (185.7) |
3 (76.2) |
5-7/16 (138.1) |
| 60 | 9-3/16 (233.4) |
4-5/16 (109.5) |
1-1/8 (28.6) |
6 (152.4) |
3/8 (9.5) |
1-9/16 (39.7) |
10-1/2 (266.7) |
8-1/2 (215.9) |
6-7/8 (174.6) |
8 (203.2) |
8-1/2 (215.9) |
15/16 (23.8) |
3-21/32 (92.9) |
7-5/16 (185.7) |
3 (76.2) |
5-7/16 (138.1) |
| 100 | 9-3/16 (233.4) |
4-5/16 (109.5) |
1-1/8 (28.6) |
6 (152.4) |
3/8 (9.5) |
1-9/16 (39.7) |
10-1/2 (266.7) |
9-3/4 (247.7) |
8-1/8 (206.4) |
8 (203.2) |
8-1/2 (215.9) |
15/16 (23.8) |
3-21/32 (92.9) |
7-5/16 (185.7) |
3 (76.2) |
5-7/16 (138.1) |
| 200 | 9-5/8 (244.5) |
4-3/4 (120.7) |
1-5/32 (29.4) |
8-3/16 (208) |
7/16 (11.1) |
2 (50.8) |
10-29/32 (277) |
9-3/4 (247.7) |
8-1/8 (206.4) |
8 (203.2) |
8-1/2 (215.9) |
1-5/16 (33.3) |
3-3/4 (95.3) |
7-1/2 (190.5) |
3 (76.2) |
5-7/16 (138.1) |
Bulletin 1494F Disconnect Switches Vault Hardware Latching (Non Pre-drilled Enclosures)
|
| Vault Hardware Kits⋆ | Switch Size [A] | A | B | C (Min.) |
D | E (Min.) |
F | G (Min.) |
H (Min.) |
J (Min.) |
K | L | M | N |
| Small and Intermediate Enclosures | ||||||||||||||
| 1494F-L1 1494F-L2 1494F-L3 |
30 | 3-7/8 (98.4) |
3/8 (9.5) |
3-1/16 (77.8) |
2-1/8 (54) |
4-1/2 (114.3) |
3-13/16 (96.8) |
13 (330.2) |
8-1/8 (206.4) |
5 (127) |
1/2 (12.7) |
1/4 (6.4) |
11/16 (17.5) |
1/2 (12.7) |
| 60 | 14 (355.6) |
|||||||||||||
| 100 | 18-7/8 (479.4) |
|||||||||||||
| 200 | 23-25/32 (604) |
|||||||||||||
| Large Enclosures | ||||||||||||||
| 1494F-L4 | 30 | 4 (101.6) |
1/2 (12.7) |
3-3/4 (95.3) |
2-1/8 (54) |
5 (127) |
3-13/16 (96.8) |
13-1/8 (333.4) |
9-13/16 (249.2) |
6 (152.4) |
5/8 (15.9) |
5/16 (7.9) |
1-1/4 (31.8) |
3/4 (19.1) |
| 60 | 13-5/8 (346.1) |
|||||||||||||
| 100 | 18-1/2 (469.9) |
|||||||||||||
| 200 | 23-13/32 (594.5) |
|||||||||||||
Bulletin 1494D Circuit Breakers♣
|
|
| Cutler-Hammer Frame | A | C | D | E | F | |
| Min. | Max. | |||||
| 150 A — EHD, FD, FDB, FDC, HFD, HMCP | 7-13/16 (198.4) | 6-3/8 (161.9) | — | 6 (152.4) | 5-5/8 (142.9) | 6-7/16 (163.5) |
| 250 A — JD, JDB, JDC, HJD, HMCP | 11-1/2 (292.1) | 8-3/8 (212.7) | — | 8 (203.2) | 5-13/16 (147.6) | 9-7/16 (239.7) |
| 400 A — KD, KDB, KDC, HKD, HMCP | 11-1/2 (292.1) | 8-3/8 (212.7) | — | 12 (304.8) | 6-7/8 (174.6) | 9-7/16 (239.7) |
| 600 A — LD, HLD, LDC, LA, HLA, LC, HLC | 11-3/8 (288.9) | 9-1/2 (241.3) | — | 8 (203.2) | 12 (304.8) | 10-17/32 (267.5) |
| 800 A — MA, MDL, HMDL, HMA, MC, ND, HND, NDC | 16 (406.4) | 9-1/2 (241.3) | — | 10 (254) | 12-5/16 (312.7) | 15-3/32 (183.4) |
| 1200 A — NB TRI-PAK | 22 (558.8) | 9-1/2 (241.3) | — | 10 (254) | 12-5/16 (312.7) | 21-3/32 (535.8) |
| 1200 A — HNC, ND, HND, NDC, NB, HNB, NC, HNC | 16 (406.4) | 9-1/2 (241.3) | — | 12 (304.8) | 12-5/16 (312.7) | 25-3/32 (183.4) |
| ♣ Approximate dimensions are for reference only. | ||||||
Bulletin 1494G, 1494GX, 1494GY Enclosed Disconnect Safety Switches
Type 3R/4/12 (Enclosure Code "F") Painted Metal Enclosures
|
| Size [A] | Fuse Style⋆ |
Number of Poles |
Bulletin No. |
Approximate Dimensions in Inches (Millimeters) | Approx. Shipping Weight [lb (kg)] |
||||||||
| A Height |
B Width |
C Depth |
D Mounting |
E Mounting |
F Mounting |
G Handle Depth |
H | J | |||||
| 30 | A | 2 or 3 | 1494G | 13-5/16 (338) |
10-1/2 (267) |
8-1/4 (210) |
14-11/16 (373) |
| 5-1/4 (133) |
5-9/16 (141) |
15-21/32 (398) |
11/32 (9) |
20 (9.07) |
| 60 | |||||||||||||
| 30 | B | 2 or 3 | 1494G | 20 (509) |
10-1/2 (267) |
10-3/16 (259) |
21-7/16 (545) |
| 5-1/4 (133) |
5-9/16 (141) |
22-13/32 (569) |
11/32 (9) |
30 (13.6) |
| 60 | |||||||||||||
| 100 | A | ||||||||||||
| 30 | C | 6 | 1494G | 27-1/2 (698) |
10-1/2 (267) |
8-1/4 (210) |
28-7/8 (733) |
| 5-1/4 (133) |
5-9/16 (141) |
29-7/8 (759) |
13/16 (21) |
60 (27.21) |
| D | |||||||||||||
| 60 | C | ||||||||||||
| D | |||||||||||||
| 30 | A | 2 or 3 | 1494GY | ||||||||||
| B | |||||||||||||
| 60 | A | ||||||||||||
| B | |||||||||||||
| 30 | A | 2 or 3 | 1494GX | 30 (762) |
20-1/2 (521) |
10-3/16 (259) |
31-3/8 (797) |
15-1/4 (387) |
15-1/4 (387) |
5-9/16 (141) |
32-3/8 (822) |
13/16 (21) |
90 (40.82) |
| B | |||||||||||||
| 60 | A | ||||||||||||
| B | |||||||||||||
| 100 | D | 6 | 1494G | ||||||||||
| 100 | A | 2 or 3 | 1494GY | ||||||||||
| B | |||||||||||||
| 100 | B | 2 or 3 | 1494G | 31-1/2 (800) |
10-1/2 (267) |
10-3/32 (257) |
32-7/8 (835) |
| 5-1/4 (133) |
5-9/16 (141) |
33-27/32 (860) |
11/32 (9) |
70 (31.73) |
| C | 6 | ||||||||||||
| 200 | A | 2 or 3 | |||||||||||
| B | |||||||||||||
| 100 | A | 2 or 3 | 1494GX | 50 (1270) |
22 (559) |
11-1/2 (292) |
51-3/8 (1305) |
15-1/4 (387) |
15-1/4 (387) |
5-9/16 (141) |
52-11/32 (1330) |
11/32 (9) |
200 (90.7) |
| B | |||||||||||||
| 200 | C | 6 | 1494G | ||||||||||
| D | |||||||||||||
| 200 | A | 2 or 3 | 1494GY | ||||||||||
| B | |||||||||||||
| 400 | A | 2 or 3 | 1494G | 50 (1270) |
22 (559) |
11-1/2 (292) |
51-3/8 (1305) |
15-1/4 (387) |
15-1/4 (387) |
7-5/8 (194) |
52-11/32 (1330) |
11/32 (9) |
200 (90.7) |
| 600 | A | ||||||||||||
| 400 | B | 2 or 3 | 1494G | 56 (1422) |
30-1/2 (775) |
13-51/64 (350) |
57-5/8 (1464) |
20 (508) |
25-1/4 (641) |
7-5/8 (194) |
62-5/8 (1590) |
1 (25.4) |
300 (136.05) |
| 600 | B | ||||||||||||
| ⋆ A = Non-Fusible, Fusible 250V - Class H/R, Fusible 600V - Class J B = Fusible 600V - Class H/R C = Non-fusible D = Fusible 250V - Class H/R, Fusible 600V - Class J |
|||||||||||||
| These enclosures have one top mounting hole located on the center line. All other enclosures have two top mounting holes located as shown. | |||||||||||||
Bulletin 1494G, 1494GX, 1494GY Enclosed Disconnect Safety Switches
Type 4/4X (Enclosure Code "C") Stainless Steel Enclosure
|
| Size [A] | Fuse Style⋆ |
Number of Poles |
Bulletin No. |
Approximate Dimensions in Inches (Millimeters) | Approx. Shipping Weight [lb (kg)] |
||||||||
| A Height |
B Width |
C Depth |
D Mounting |
E Mounting |
F Mounting |
G Handle Depth |
H | J | |||||
| 30 | A | 2 or 3 | 1494G | 13-5/16 (338) |
10-1/2 (267) |
8-9/16 (217) |
14-11/16 (373) |
| 5-1/4 (133) |
5-9/16 (141) |
15-21/32 (398) |
13/16 (21) |
20 (9.07) |
| 60 | |||||||||||||
| 30 | B | 2 or 3 | 1494G | 27-1/2 (698) |
10-1/2 (267) |
8-1/4 (210) |
28-7/8 (733) |
| 7 (178) |
5-9/16 (141) |
29-3/4 (756) |
13/16 (21) |
60 (27.21) |
| C | 6 | ||||||||||||
| D | |||||||||||||
| 60 | B | 2 or 3 | |||||||||||
| C | 6 | ||||||||||||
| D | |||||||||||||
| 30 | A | 2 or 3 | 1494GY | ||||||||||
| B | |||||||||||||
| 60 | A | ||||||||||||
| B | |||||||||||||
| 30 | A | 2 or 3 | 1494GX | 30 (762) |
20-1/2 (521) |
9-7/8 (251) |
31-3/8 (797) |
17 (432) |
17 (432) |
5-9/16 (141) |
32-1/4 (819) |
13/16 (21) |
90 (40.82) |
| B | |||||||||||||
| 60 | A | ||||||||||||
| B | |||||||||||||
| 100 | A | 2 or 3 | 1494G | ||||||||||
| B | |||||||||||||
| C | 6 | ||||||||||||
| D | |||||||||||||
| 100 | A | 2 or 3 | 1494GX | 50 (1270) |
22 (559) |
11-3/16 (284) |
51-3/8 (1305) |
18-1/2 (470) |
18-1/2 (470) |
5-9/16 (141) |
52-1/4 (1327) |
13/16 (21) |
200 (90.7) |
| B | |||||||||||||
| 200 | A | 2 or 3 | 1494G | ||||||||||
| B | |||||||||||||
| C | 6 | ||||||||||||
| D | |||||||||||||
| 400 | A | 2 or 3 | 1494G | 56 (1422) |
30-1/2 (775) |
13-51/64 (350) |
57-5/8 (1464) |
20 (508) |
25-1/4 (641) |
7-5/8 (194) |
58-5/8 (1489) |
1 (25.4) |
300 (136.05) |
| B | |||||||||||||
| 600 | A | ||||||||||||
| B | |||||||||||||
| ⋆ A = Non-Fusible, Fusible 250V - Class H/R, Fusible 600V - Class J B = Fusible 600V - Class H/R C = Non-fusible D = Fusible 250V - Class H/R, Fusible 600V - Class J |
|||||||||||||
| These enclosures have one top mounting hole located on the center line. All other enclosures have two top mounting holes located as shown. | |||||||||||||
Bulletin 1494H Heavy Duty Safety Switches
Type 1 (Enclosure Code "A") General Purpose Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
Knockout Fig. # |
| 30 | 240V | 10-9/32 (261.1) | 6-3/8 (162.1) | 3-5/16 (84.1) | 7-1/8 (181) | 1 |
| 600V | 12-19/32 (319.8) | 8-3/8 (212.9) | 4 (101.6) | 9-1/2 (241.3) | 2 | |
| Non-fusible | 10-3/8 (263.7) | 8-3/8 (212.9) | 4 (101.6) | 9-1/4 (235) | 3 | |
| 60 | 240V | 17-19/32 (446.8) | 9-3/8 (238.3) | 5 (127) | 10-3/64 (255.3) | 4 |
| 600V | 21-11/32 (542) | 5 | ||||
| Non-fusible | 17-19/32 (446.8) | 4 | ||||
| 100 | 240V | 21-11/32 (542) | 9-3/8 (238.3) | 5 (127) | 10-3/64 (255.3) | 5 |
| 600V | 22-11/32 (567.4) | 4 | ||||
| Non-fusible | 17-19/32 (446.8) | 4 | ||||
| 200 | 240V | 31-5/8 (803.3) | 13-7/16 (341.4) | 5-1/4 (133.4) | 14-7/16 (366) | 6 |
| 600V | ||||||
| Non-fusible | ||||||
Knockouts — Conduit Size
|
|
|
||
| Fig. 1 | Fig. 2 | Fig. 3 | ||
|
|
|
||
| Fig. 4 | Fig. 5 | Fig. 6 | ||
| Switch Size [A] | Fuse Style | Knockouts | ||||
| A | B | C | D | E | ||
| 30 | 240V | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
3/8 x 1/2 x 3/4 x 1 (9.5 x 12.7 x 19.1 x 25.4) |
— | — |
| 600V | 1/2 x 3/4 x 1 (12.7 x 19.1 x 25.4) |
1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
|||
| Non-fusible | ||||||
| 60 | 240V | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
— |
| 600V | ||||||
| Non-fusible | ||||||
| 100 | 240V | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
— |
| 600V | ||||||
| Non-fusible | ||||||
| 200 | 240V | 1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
9/32 (7.1) | 1/2 (12.7) |
— | — |
| 600V | ||||||
| Non-fusible | ||||||
Bulletin 1494H Heavy Duty Safety Switches
Type 3R (Enclosure Code "N") Rain-Proof Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
Knockout Fig. # |
| 30 | 240V | 10-5/8 (269.9) | 6-3/8 (162.1) | 3-5/16 (84.1) | 7-1/8 (181) | 7 |
| 600V | 13-13/64 (335.3) | 8-3/8 (212.9) | 4 (101.6) | 9-13/32 (239) | 8 | |
| Non-fusible | 13-13/64 (335.3) | 8-3/8 (212.9) | 4 (101.6) | 9-13/32 (239) | 8 | |
| 60 | 240V | 17-7/16 (443) | 9-3/8 (238.3) | 5 (127) | 10-3/64 (255.3) | 9 |
| 600V | 22-3/16 (563.6) | 10-1/2 (267) | ||||
| Non-fusible | 17-7/16 (443) | 10-3/64 (255.3) | ||||
| 100 | 240V | 22-3/16 (563.6) | 9-3/8 (238.3) | 5 (127) | 10-1/2 (267) | 9 |
| 600V | 22-3/16 (563.6) | |||||
| Non-fusible | 17-7/16 (443) | 10-3/64 (255.3) | ||||
| 200 | 240V | 31-7/16 (798.6) | 13-3/8 (339.9) | 5-15/32 (138.9) | 14-1/8 (361.9) | 10 |
| 600V | ||||||
| Non-fusible | ||||||
Knockouts — Conduit Size
|
|
|
|
|||
| Fig. 7 | Fig. 8 | Fig. 9 | Fig. 10 |
| Switch Size [A] | Fuse Style | Knockouts | |||
| A | B | C | D | ||
| 30 | 240V | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
3/8 x 1/2 x 3/4 x 1 (9.5 x 12.7 x 19.1 x 25.4) |
— |
| 600V | 1/2 x 3/4 x 1 (12.7 x 19.1 x 25.4) |
1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
||
| Non-fusible | |||||
| 60 | 240V | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
| 600V | |||||
| Non-fusible | |||||
| 100 | 240V | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
| 600V | |||||
| Non-fusible | |||||
| 200 | 240V | 1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
9/32 (7.1) | 1/2 (12.7) |
— |
| 600V | — | ||||
| Non-fusible | — | ||||
Bulletin 1494H Heavy Duty Safety Switches
Type 12 (Enclosure Code "F") Dust-Tight Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
| 30 | 240V | 11-3/8 (288.9) | 7-3/8 (187.3) | 5-1/16 (128.6) | 8-1/8 (206.4) |
| 600V | 13-3/8 (339.7) | 9-3/8 (238.1) | 5-5/16 (134.9) | 10-1/4 (260.4) | |
| Non-fusible | 5-1/16 (128.6) | ||||
| 60 | 240V | 19-3/8 (492.1) | 9-3/8 (238.1) | 5-1/16 (128.6) | 10-1/4 (260.4) |
| 600V | 5-5/16 (134.9) | ||||
| Non-fusible | 5-1/16 (128.6) | ||||
| 100 | 240V | 25-3/8 (644.5) | 13-1/2 (342.9) | 5-1/16 (128.6) | 14-1/4 (362) |
| 600V | 5-5/16 (134.9) | ||||
| Non-fusible | |||||
| 200 | 240V | 35-1/8 (892.2) | 13-1/2 (342.9) | 5-5/16 (134.9) | 15-1/4 (387.4) |
| 600V | 14-1/2 (368.3) | ||||
| Non-fusible | |||||
Bulletin 1494HL General Duty Safety Switches
Type 1 (Enclosure Code "A") General Purpose Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
Knockout Fig. # |
| 30 | 240V | 10-9/32 (261.1) | 6-1/2 (165.1) | 3-5/16 (84.1) | 6-29/32 (175.3) | 1 |
| 60 | 13-27/32 (351.5) | 8-1/2 (215.9) | 4 (101.6) | 8-7/8 (225.6) | 2 | |
| 100 | 21-11/32 (542) | 9-1/2 (241.3) | 5 (127) | 9-7/8 (251) | 3 | |
| 200 | 29-1/8 (739.6) | 13-7/16 (341.4) | 5-5/16 (134.9) | 13-15/16 (354.1) | 4 | |
Knockouts — Conduit Size
|
|
|
|
|||
| Fig. 1 | Fig. 2 | Fig. 3 | Fig. 4 |
| Switch Size [A] | Knockouts | ||||
| A | B | C | D | E | |
| 30 | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
3/8 x 1/2 x 3/4 x 1 (9.5 x 12.7 x 19.1 x 25.4) |
— | — |
| 60 | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
1/2 x 3/4 x 1 (12.7 x 19.1 x 25.4) |
1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
| 100 | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
— |
| 200 | 1/2 (12.7) | 1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
9/32 (7.1) | — | — |
Type 3R (Enclosure Code "N") Rain-Proof Painted Metal Enclosures
|
| Switch Size [A] | Fuse Style | A Height |
B Width |
C Depth |
D Width (with handle) |
Knockout Fig. # |
| 30 | 240V | 10-1/32 (254.8) | 6-3/8 (162.1) | 3-5/16 (84.1) | 7-1/8 (180.8) | 5 |
| 60 | 13-15/16 (353.8) | 8-3/8 (212.9) | 3-7/8 (225.6) | 9-3/32 (230.9) | 6 | |
| 100 | 21-7/16 (544.3) | 9-3/8 (238.3) | 5 (127) | 9-61/64 (252.7) | 7 | |
| 200 | 28-15/16 (735.1) | 13-3/8 (339.9) | 5-5/16 (134.9) | 14-1/16 (357.1) | 8 | |
Knockouts — Conduit Size
|
|
|
|
|||
| Fig. 5 | Fig. 6 | Fig. 7 | Fig. 8 |
| Switch Size [A] | Knockouts | |||
| A | B | C | D | |
| 30 | 9/32 (7.1) | 1/2 x 3/4 (12.7 x 19.1) |
3/8 x 1/2 x 3/4 x 1 (9.5 x 12.7 x 19.1 x 25.4) |
— |
| 60 | 9/32 (7.1) | 1/2 x 3/4 x 1 (12.7 x 19.1 x 25.4) |
1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
| 100 | 9/32 (7.1) | 1/2 x 3/4 x 1 x 1-1/4 (12.7 x 19.1 x 25.4 x 31.8) |
3/4 x 1 x 1-1/4 x 1-1/2 (19.1 x 25.4 x 31.8 x 38.1) |
1 x 1-1/4 x 1-1/2 x 2 (25.4 x 31.8 x 38.1 x 50.8) |
| 200 | 1/2 (12.7) | 1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
1 x 1-1/2 x 2 x 2-1/2 (25.4 x 38.1 x 50.8 x 63.5) |
— |