Motor Control, IEC

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Mounting System

Mounting System

Introduction Standards Compliance and Certifications Catalog Number Explanation Product Selection Accessories Specifications Approximate Dimensions
Product Selection

ISO Busbar Modules


  Description Rated Thermal
Current Ith [A]
Width [mm] Rails Pkg.
Qty.
Cat. No.
Click to enlarge - 141A-SS_pp_bw ISO Busbar Modules with Wires — Short Length
Wires on DAP for electrical connection
200 mm tall
Top Hat Rails: R = MCS-Specific top hat rail
25 45 2R 1 141A-SS45RR25
54 141A-SS54RR25
45 54 141A-SS54RR45
63 141A-SS63RR45
Without electrical connections 45 1R 1 141A-SS45R
54 141A-SS54R
Click to enlarge - 141A-SM_pp_bw ISO Busbar Modules with Wires — Medium Length
Wires on DAP for electrical connection
260 mm tall
Top Hat Rails: R = MCS-Specific top hat rail; S = Standard top hat rail
25 45 1R+1S 1 141A-SM45RS25
54 141A-SM54RS25
45 54 141A-SM54RS45
63 141A-SM63RS45
Without electrical connections 45 1S 1 141A-SM45S
54 141A-SM54S
63 141A-SM63S
  

Standard Busbar Modules


  Description Rated Thermal
Current Ith [A]
Width [mm] Rails Pkg. Qty. Cat. No.
Click to enlarge - 141A-GS45_pp_bw Standard Busbar Modules with Wires — Short Length
With wires for electrical connection, 200 mm tall
Top Hat Rails:
R = MCS-Specific top hat rail
M = Metal top hat rail
S = Standard top hat rail
16 45 2R 1 141A-GS45RR16
54 141A-GS54RR16
25 45 141A-GS45RR25
54 141A-GS54RR25
45 54 141A-GS54RR45
63 141A-GS63RR45
125
(For 140-CMN)
90 1M 141A-GS90M125
180 141A-GS180M125
270 141A-GS270M125
125
(For 140M-H, 140U-H, and 140UE-H)§ 
180 1M 141A-GS180M125H
270 141A-GS270M125H
Without electrical connections
(e.g., for reversing starters)
45 1R 141A-GS45R
54 141A-GS54R
72 1S 141A-GS72S
81 141A-GS81S
Click to enlarge - 141A-GM_pp_bw Standard Busbar Modules with Wires — Medium Length
With wires for electrical connection
260 mm tall
Top Hat Rails:
R = MCS-Specific top hat rail
S = Standard top hat rail
25 45 1R+1S 1 141A-GM45RS25
54 141A-GM54RS25
45 54 141A-GM54RS45
63 141A-GM63RS45
Without electrical connections
(e.g., for reversing starters)
45 1S 141A-GM45S
54 141A-GM54S
63 141A-GM63S
Click to enlarge - 141A-FS_pp_bw Standard Busbar Modules with Terminals — Short Length
200 mm tall
With terminals for electrical connection
S = Standard top hat rail
25 45 1S 1 141A-FS45S25
63 54 141A-FS54S63
63 141A-FS63S63
72 141A-FS72S63
81 141A-FS81S63
Standard Busbar Modules with Terminals — Medium Length
260 mm tall
With terminals for electrical connection
S = Standard top hat rail
25 45 2S 141A-FM45SS25
63 54 141A-FM54SS63
63 141A-FM63SS63
72 141A-FM72SS63
81 141A-FM81SS63
Click to enlarge - 141A-196-3 Standard Busbar Module with Terminals on Top
222 mm tall
With box terminals on top for electrical connection
Wire size 70 mm2 (2/0 AWG)
Universal mounting capability with sliding pocket nuts (M4)
200 108 1 141A-FS108V200T
Standard Busbar Module with Terminals on Top
320 mm tall
With box terminals on top for electrical connection
Wire size 120 mm2 (250 MCM)
Universal mounting capability with sliding pocket nuts (M4)
250 110 141A-FL110V250T
Click to enlarge - 141A-196-4 Standard Busbar Module with Terminals on Bottom
222 mm tall
With box terminals on bottom for electrical connection
Wire size 70 mm2 (2/0 AWG)
Universal mounting capability with sliding pocket nuts (M4)
200 108 1 141A-FS108V200B
  
§ Also requires a Cat. No. 140U-H-DRA DIN Rail adaptor.

Circuit Breaker Mounting Modules for Bulletin 140U and 140M Circuit Breakers


Click to enlarge - 141A-CUH_pp_bw Description For Use With Rated Thermal Current Ith [A] Width [mm] Pkg. Qty. Cat. No.
Standard Busbar Module with Flexible Connecting
Wires for electrical connection
For use with Bulletin 140U circuit breaker (H-Frame)
For use with Bulletin 140M circuit breaker (H-Frame)
Meets feeder circuit spacings per UL 508A
140U H-Frame
140M H-Frame
(Top feed)
125 90 1 141A-CUH125T
140U H-Frame
140M H-Frame
(Bottom feed)
125 90 141A-CUH125B
Click to enlarge - 141A-CU_pp_bw Standard Busbar Module with Rear Connecting Studs
for electrical connection
For use with Bulletin 140U circuit breakers (J-, K- or L-Frame)
For use with Bulletin 140M circuit breakers (J-, K- or L-Frame)
Meets feeder circuit spacings per UL 508A
140U J-Frame
140M J-Frame
(Top or bottom feed)
250 105 141A-CUJ250
140U K-Frame
140U L-Frame
140M L-Frame
(Top or bottom feed)
630 140 141A-CUL600
  

Panel Mounting Modules


  Description Width [mm] Rails Pkg. Qty. Cat. No. Cat. No.
(with PE Terminal)
Click to enlarge - 141A-197-1 Mounting Module — Short Length
228 mm tall
Top hat rails:
R = MCS-specific top hat rail
For 2-component starters
  


45  


2R 1 141A-WS45RR 141A-WS45RRP
  


54  


141A-WS54RR 141A-WS54RRP
Click to enlarge - 141A-197-2 Mounting Module — Medium Length
283 mm tall
Top hat rails:
R = MCS-specific top hat rail
For 3-component starters using 193-ED or -EE overload relays
  


45  


2R 1 141A-WM45RR 141A-WM45RRP
  


54  


141A-WM54RR 141A-WM54RRP
Click to enlarge - 141A-197-3 Mounting Module — Long Length
333 mm tall
Top hat rails:
R = MCS-specific top hat rail
For 3-component starters using 193-EC, -ED or -EE overload relays
  


45  


2R 1 141A-WL45RR 141A-WL45RRP
  


54  


141A-WL54RR 141A-WL54RRP
  

Busbar Components

  Description Ampere Rating ¬  Height x Width (mm) Pkg.
Qty.
Cat. No.
Click to enlarge - 141A-198-1 Busbar
800 mm length
Tinned copper busbarT 
200 12 x 5 3 141A-B125A
250‡  15 x 5 141A-B155A
320 20 x 5 141A-B205A
400‡  25 x 5 141A-B255A
450 30 x 5 141A-B305A
360 12 x 10 141A-B1210A
520 20 x 10 141A-B2010A
630 30 x 10 141A-B3010A
Click to enlarge - 141A-198-2 Busbar
1600 mm length
Tinned copper busbarT 
200 12 x 5 141A-B125B
250‡  15 x 5 141A-B155B
320 20 x 5 141A-B205B
400‡  25 x 5 141A-B255B
450 30 x 5 141A-B305B
360 12 x 10 141A-B1210B
520 20 x 10 141A-B2010B
630 30 x 10 141A-B3010B
Click to enlarge - 141A-198-3 Busbar
2400 mm length
Tinned copper busbarT 
200 12 x 5 12 141A-B125N
250‡  15 x 5 141A-B155N
320 20 x 5 141A-B205N
400‡  25 x 5 141A-B255N
450 30 x 5 141A-B305N
360 12 x 10 6 141A-B1210N
520 20 x 10 141A-B2010N
630 30 x 10 141A-B3010N
Click to enlarge - 141A-BT_pp_bw Double-T Busbar
2400 mm length
Tin-plated copper busbar
960 TT 1 141A-BT11NZ
1250 TT 1 141A-BT12NZ
  
¬ Ratings shown are based upon tested conditions at an ambient temperature of 40 °C and a busbar temperature of 70 °C.
T Only available in North America.
‡ IEC applications only

Busbar Components, Continued

  Description Busbar [mm] Pkg. Qty. Cat. No.
Click to enlarge - 141A-TR3_GS Busbar Support
60 mm pole center spacing
3-pole with inside mounting holes (meets feeder circuit spacings per UL508A)
12, 20, 30 x 5
or
12, 20, 30 x 10
10 141A-TU3
Busbar Support
60 mm pole center spacing
3-pole with inside mounting holes (approved for branch circuit applications per UL508)
12…30 x 5
or
12…30 x 10
10 141A-TR3
Busbar Support
60 mm pole center spacing
4-pole with inside mounting holes
141A-TR4
Busbar Support
1-pole
141A-TR1
Click to enlarge - 141A-TR3F16 BW Busbar Support with terminals
60 mm pole center spacing
Terminals for electrical connections
1.5…16 mm2 (#16…6 AWG)
3-pole
12…30 x 5
or
12…30 x 10
10 141A-TR3F16
Click to enlarge - 141A-T1_pp_bw Double-T Busbar Support
For double-T busbars
60 mm spacing
(meets feeder circuit spacings per UL 508A)
3-pole 3 141A-T13
1-pole 10 141A-T11
Click to enlarge - 141A-TR_E pp_bw Busbar End Cover
Prevents contact with the busbar ends and prevents busbars from sliding.
The end cover can easily be clipped on the busbar support.
3-pole (for use with Cat. Nos. 141A-TU3 or 141A-TR3) 10 141A-TR3E
4-pole (for use with Cat. No. 141A-TR4) 141A-TR4E
3-Pole (for use with Cat. No. 141A-T13 double T busbar supports) 4 141A-T13E
  

Busbar Components, Continued

  Description Busbar [mm] Pkg. Qty. Cat. No.
Click to enlarge - 141A-199-1 Supply Module
3-pole
6…50 mm2 (10…1/0 AWG)
54 mm wide
(meets feeder circuit spacings per UL 508A)
12…30 x 5
or
12…30 x 10
1 141A-VN370
Click to enlarge - 141A-199-2 Supply Module
3-pole
35…120 mm2 (2 AWG…250 MCM)
81 mm wide
(meets feeder circuit spacings per UL 508A)
141A-VN3120
Click to enlarge - 2_18_fn10_GS Supply Module
3-pole
95…185 mm2 (3/0 AWG…350 MCM)
135 mm wide
141A-VN3185
Supply Module
3-pole
for round conductors
150…300 mm2 (300…600 MCM)
135 mm wide
141A-VN3300R
Supply Module
3-pole
for flat conductors up to 32 x 20 mm
equivalent to 300 mm2 (300…600 MCM) round conductor ampacity
135 mm wide
141A-VN3300F
Click to enlarge - PA66_GF10_FR_right Supply Module
3-Pole (set of 3 terminals)
for round conductors
120…300 mm2 (250…600 MCM)
153 mm wide (3 single poles of 51 mm each)
(meets feeder circuit spacings per UL 508A)
Requires Cat. No. 141A-BK180, 141A-BK228 or 141A-BK250 terminal cover
1 141A-VU3300R
Supply Module
3-Pole (set of 3 terminals)
for flat conductors up to 32x20 mm
equivalent to 300 mm2 (600 MCM)
153 mm wide (3 single poles of 51 mm each)
(meets feeder circuit spacings per UL 508A)
Requires Cat. No. 141A-BK180, 141A-BK228 or 141A-BK250 terminal cover
1 141A-VU3300F
Click to enlarge - 141A-VS_pp_bw Single Terminals
Single terminals for supplying busbars
2.5…16 mm2 (#14…6 AWG)
12…30 x 5 25 141A-VS116
12…30 x 10 141A-VS216
Single Terminals
Single terminals for supplying busbars
4…35 mm2 (#12…2 AWG)
12…30 x 5 141A-VS135
12…30 x 10 141A-VS235
Single Terminals
Single terminals for supplying busbars
16…70 mm2 (#6…2/0 AWG)
12…30 x 5 141A-VS170
12…30 x 10 141A-VS270
Single Terminals
Single terminals for supplying busbars
16…120 mm2 ( #6…250 MCM)
12…30 x 10 141A-VS2120
Click to enlarge - 141A-VS5_pp_bw Profile Terminals
For double-T busbars
To connect with flat busbars and flexible copper busbars
400…800 mm2 3 141A-VS54136F
500…750 mm2 3 141A-VS55121F
600…900 mm2 3 141A-VS56421F
600…1200 mm2 3 141A-VS56436F
800…1600 mm2 3 141A-VS58136F
1000…2000 mm2 3 141A-VS510136F
  

Busbar Components, Continued

  Description Busbar [mm] Pkg. Qty. Cat. No.
Click to enlarge - 141A-BK_pp_bw Terminal Cover
Finger protection when busbars supplied with single terminals. Attaches directly to busbars.
Height: 180 mm, Width: 54 mm
12…30 x 5
or
12…30 x 10
1 141A-BK1
Click to enlarge - PA66_GF30_FR_right Terminal Cover
Finger protection when bus bars are supplied by Cat. No. 141A-VU3300_ supply module
Attaches directly to bus bars
Height: 200 mm
Depth: 90 mm
Width: 180 mm 1 141A-BK180
Width: 228 mm 1 141A-BK228
Width: 250 mm 1 141A-BK250
Terminal Cover Kit
Customized terminal cover width using end supports, front shroud and top/bottom shroud
Shrouds can be cut to desired width
Attaches directly to bus bars
Left and right support 1 141A-BKH
Front shroud, 1100 mm 1 141A-BKC
Top/bottom shroud, 1100 mm 1 141A-BKS
Click to enlarge - 141A-VC3_pp_bw Busbar Connector
System distance: 5…10 mm
12…20 x 5
or
12…20 x 10
12 141A-VC3A
Busbar Connector
System distance: 13…20 mm
20…30 x 5
or
20…30 x 10
6 141A-VC3B
Busbar Connector
System distance: 50…60 mm
3 141A-VC3C
Busbar Connector
System distance: 100…110 mm
3 141A-VC3D
Click to enlarge - 141A-VC5_pp_bw Double-T Busbar Connectors
For connection of double-T busbar racks with same dimensions, Width: 50 mm
Double-T 6 141A-VC5E
Double-T Busbar Connectors
For connection of double-T busbar racks with same dimensions, Width: 95 mm
3 141A-VC5F
Double-T Busbar Connectors
For connection of double-T busbar racks with same dimensions, Width: 150 mm
3 141A-VC5G
Click to enlarge - 141A-BCF_pp_bw Busbar Shroud Cover
200 x 1100 mm
Covers all three busbars
12…30 x 5 or 12…30 x 10 2 141A-BCF1
Busbar Shroud Holder
Two required per section of Busbar Shroud Cover
10 141A-BCF1H
Click to enlarge - 141A_p30 Single Pole Busbar Covers
Snap-on profile for single busbars for protection against electric shock.
Length: 1 m, can be cut to length.
12…30 x 5 10 141A-BS5
12…30 x 10 141A-BS10
Click to enlarge - 141A-BCT1 pp_bw Busbar Cover
For double-T busbars
Length: 1 m; can be cut to length
5 141A-BCT1
Click to enlarge - 141A-BST_pp_bw Compartment Section
Fits to 141A-T13 double-T busbar supports
Adjusts the installation depth
48 mm Double-T 1 141A-BST48
76 mm 1 141A-BST76
Click to enlarge - ShroudMTSys-bw Panel Busbar Shroud
Provides isolation between busbar and panel (required for feeder-circuit applications per UL 508A)
230 x 810 mm
All 2 141A-BCR
  

Busbar Components, Continued

  Description PQ Cat. No.
Click to enlarge - 141A-NF_pp_bw Busbar Fuse Switch
3-pole switch disconnector with fuses
For fuse links D02, for D01 fuses use reducer 400V AC 63 A¬  1 141A-NF0102
For 10 x 38 NFC cylindrical fuses 690V AC 32 A 1 141A-NF1038
Click to enlarge - 141A-NFAD pp_bw Spacer Module
Connectable on both sides
9 mm wide
5 141A-NFAD
Click to enlarge - 141A-NFAR pp_bw Reducer
D02 reducer for D01 fuses
For 141A-NF0102
20 141A-NFAR
Click to enlarge - 141A-NFJ_pp_bw Class J Busbar Fuse Base
For mounting on 10 mm wide and double-T busbars
Top or bottom connection
For UL Class J fuses
61…100 A 1 141A-NFJ100
101…200 A 1 141A-NFJ200
201…400 A 1 141A-NFJ400
  
¬ The use of spacer module 141A-NFAD is recommended for a continuous load above 35 A.
PQ = Package Quantity

Busbar Components, Continued

  Description PQ Cat. No.
Click to enlarge - 141A-NFD_pp_bw NH Fuse Switch Disconnector
Connection bottom or top
Size 00 for plugging on 5, 10 mm thick and double-T busbars.
Sizes 1 and 2 conversion kit 141A-NFAFR5 is required for plugging on 5 mm thick busbars.
Size 3 only for plugging on 10 mm and double-T busbars.
Size 00
200 x 106 mm
M8
70 mm2
160 A 1 141A-NFD160
Size 1
243 x 184 mm
M10
120 mm2
250 A 1 141A-NFD250
Size 2
288 x 210 mm
M10
240 mm2
400 A 1 141A-NFD400
Size 3
300 x 256 mm
M12
240 mm2
630 A 1 141A-NFD630
Click to enlarge - 141A-NFASNFD pp_bw Pilot Switch
For NH-fuse switch disconnectors
Signaling ON/OFF position of lid
250V AC/5 A
30V DC/4 A
Size 00…3 1 141A-NFASNFD
Click to enlarge - 141A-NFVF_pp_bw Wedge Clamp Terminal
For NH-fuse switch disconnectors
Connection accessories
Size 1
18 x 10 mm
70…150 mm2 1 141A-NFVF1150
Size 2
21 x 15 mm
120…240 mm2 1 141A-NFVF2240
Size 3
25 x 20 mm
150…300 mm2 1 141A-NFVF3300
Click to enlarge - 141A-NFAFR_pp_bw Conversion Kit
For NH-fuse switch disconnector to reduce size 1 and 2 on to 5 mm busbars
Size 1 and 2 1 141A-NFAFR5
Click to enlarge - 141A-NFAC_pp_bw Cover for Cable Lugs
For NH fuse switch disconnecor
Can be clipped on bottom or top
Size 00 1 141A-NFAC00A
Size 1 2 141A-NFAC1A
Size 2 2 141A-NFAC2A
Size 3 2 141A-NFAC3A
  
PQ = Package Quantity