3-Pole AC- and DC-Operated Contactors

Ie [A] Ratings for Switching AC Motors — AC-2, AC-3, AC-4 Aux. Contacts Cat. No.
3-Phase kW (50 Hz) Hp (60 Hz) Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a
AC-3 AC-1 230V 400V/415V 500V 690V 1-Phase 3-Phase
115V 230V 200V 230V 460V 575V N.O. N.C.
9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2 1 0 §  100-C09Ä10
0 1 §  100-C09Ä01
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 1 0 §  100-C12Ä10
0 1 §  100-C12Ä01
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 1 0 §  100-C16Ä10
0 1 §  100-C16Ä01
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 1 0 100-C23Ä10
0 1 100-C23Ä01
30 65 10 15 15 15 2 5 7-1/2 10 20 25 0 0 100-C30Ä00
1 0 100-C30Ä10
0 1 100-C30Ä01
37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 0 0 100-C37Ä00
1 0 100-C37Ä10
0 1 100-C37Ä01
43 85 13 22 25 22 3 7-1/2 10 15 30 30 0 0 100-C43Ä00
1 0 100-C43Ä10
0 1 100-C43Ä01
55 85 15 30 30 30 5 10 15 20 40 40 0 0 100-C55Ä00
1 0 100-C55Ä10
0 1 100-C55Ä01
60 100 18.5 32 37 32 5 10 15 20 40 50 0 0 100-C60Ä00
1 0 100-C60Ä10
0 1 100-C60Ä01
72 100 22 40 45 40 5 15 20 25 50 60 0 0 100-C72Ä00
1 0 100-C72Ä10
0 1 100-C72Ä01
85 100 25 45 55 45 7-1/2 15 25 30 60 60 0 0 100-C85Ä00
1 0 100-C85Ä10
0 1 100-C85Ä01
97 130 30 55 55 55 10 20 30 30 75 75 0 0 100-C97Ä00
1 0 100-C97Ä10
0 1 100-C97Ä01
  
§ For screwless terminals, add an "R" after the letter "C" in the catalog number. Example: Cat. No. 100-C09Ä10 becomes Cat. No. 100-CR09Ä10. The AC-1 rating for 100-CR contactors is limited to 25 A.

Ä Coil voltage code and terminal position—see Ä Coil Voltage Code and Terminal Position


4-Pole AC- and DC-Operated Contactors

Ie [A] Ratings for Switching AC Motors — AC-2, AC-3 Contact Configuration, Main Pole Cat. No.
3-Phase kW (50 Hz)⋆  Hp (60 Hz) Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a
AC-3 AC-1 230V 400V/415V 500V 690V 1-Phase 3-Phase ⋆ 
115V 230V 200V 230V 460V 575V N.O. N.C.
9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2 4 0 §  100-C09Ä400
3 1 §  100-C09Ä300
2 2 §  100-C09Ä200
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 4 0 §  100-C12Ä400
3 1 §  100-C12Ä300
2 2 §  100-C12Ä200
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 4 0 §  100-C16Ä400
3 1 §  100-C16Ä300
2 2 §  100-C16Ä200
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 4 0 100-C23Ä400
3 1 100-C23Ä300
2 2 100-C23Ä200
37 75 11 18.5/20 20 18.5 3 5 10 10 25 30 4 0 100-C40Ä400
2 2 100-C40Ä200
85 130 25 45 55 45 7-1/2 15 25 30 60 50 4 0 100-C90Ä400
2 2 100-C90Ä200
  
⋆ Three-phase ratings apply only to contactors with at least three N.O. power poles.
§ For screwless terminals, add an "R" after the letter "C" in the catalog number. Example: Cat. No. 100-C09Ä400 becomes Cat. No. 100-CR09Ä400. The AC-1 rating for 100-CR contactors is limited to 25 A.

Ä Coil voltage code and terminal position—see Ä Coil Voltage Code and Terminal Position


Reversing AC- and DC-Operated Contactors

Click to enlarge - 100C_104C-67-2 Click to enlarge - 100C_104C-69-2 Click to enlarge - 100C_104C-69-3

Ie [A] Ratings for Switching AC Motors — AC-2, AC-3, AC-4 Auxiliary Contacts
Installed per Contactor
Cat. No.
3-Phase kW (50 Hz) Hp (60 Hz) Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a
AC-3 AC-1 230V 400V/415V 500V 690V 1-Phase 3-Phase
115V 230V 200V 230V 460V 575V N.O. N.C.⋆ 
9 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2 1 1 104-C09Ä22
12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 1 1 104-C12Ä22
16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 1 1 104-C16Ä22
23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 1 1 104-C23Ä22
30 65 10 15 15 15 2 5 7-1/2 10 20 25 0 1 104-C30Ä02
1 1 104-C30Ä22
37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 0 1 104-C37Ä02
1 1 104-C37Ä22
43 85 13 22 25 22 3 7.5 10 15 30 30 0 1 104-C43Ä02
1 1 104-C43Ä22
55 85 15 30 30 30 5 10 15 20 40 40 0 1 104-C55Ä02
1 1 104-C55Ä22
60 100 18.5 32 37 32 5 10 15 20 40 50 0 1 104-C60Ä02
1 1 104-C60Ä22
72 100 22 40 45 40 5 15 20 25 50 60 0 1 104-C72Ä02
1 1 104-C72Ä22
85 100 25 45 55 45 7-1/2 15 25 30 60 60 0 1 104-C85Ä02
1 1 104-C85Ä22
97 130 30 55 55 55 10 20 30 30 75 75 0 1 104-C97Ä02
1 1 104-C97Ä22
  

⋆ The N.C. auxiliary contact is supplied as part of the mechanical/electrical interlock.


Ä Coil Voltage Code and Terminal Position

The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60Hz:
Cat. No. 100-C09Ä10 becomes Cat. No.100-C09D10.


[V] 12 24 32 36 42 48 100 100-110 110 120 127 200 200-220 208 208-240 220-230 230 230-240 240 277 347 380 380-400 400 400-415 440 480 500 550 600
Hz
50 Hz R K V W X Y KP D P S KG L F VA T N G B M C
60 Hz Q J V X KP D KG H L A T I E N B C
50/60 Hz KJ KY KP KD KG KL§  KL§  KF KA KN KB
  
§ Not available on 100/104-C90 or -C97 contactors.

DC Voltages [V] 9 12 24 36 36…48 48 48-72 60 64 72 80 110 110-125 115 125 220 220-250 230 250
100-C09…C55 Electronic with Integrated Diode EQ EJ EW EY ED EA
100-C60…C97 with Integrated Diode DR DQ DJ DW DY DZ DB DG DE DD DP DS DA DF DT
  

Coil Terminal Position

  • All contactors are delivered with the coil terminals located on the line side.


  • For load side coil terminations, insert a “U” prior to the coil voltage code.
    Ordering example: Cat. No. 100-C09UD10.


  • Click to enlarge - 100C_104C-68-1
    Cat. No.100-C09Ä10Line Side


    Click to enlarge - 100C_104C-68-2
    Cat. No.100-C09UÄ10Load Side