Description
|
Connection Diagrams
|
|
|
For Use With
|
Pkg. Qty.
|
Screw Type Terminals
|
Spring Clamp Terminals
|
| N.O.
|
N.C.
|
Cat. No.
|
Cat. No.
|
|
Front-Mounted Auxiliary Contacts Auxiliary contact blocks 2- and 4-pole versions Choice of contact configurations Snap on, no tools required Electronic-compatible bifurcated contacts for signals down to 15V/2 mA Mirror Contact performance per IEC 60947-4-1
|
|
0
|
2
|
100-K05…K12
|
1
|
100-KFC02
|
100-KRFC02
|
|
1
|
1
|
100-K05…K12
|
1
|
100-KFC11
|
100-KRFC11
|
|
2
|
0
|
100-K05…K12
|
1
|
100-KFC20
|
100-KRFC20
|
|
|
0
|
4
|
100-K05…K12
|
1
|
100-KFC04
|
100-KRFC04
|
|
1
|
3
|
100-K05…K12
|
1
|
100-KFC13
|
100-KRFC13
|
|
3
|
1
|
100-K05…K12
|
1
|
100-KFC31
|
100-KRFC31
|
|
2
|
2
|
100-K05…K12
|
1
|
100-KFC22
|
100-KRFC22
|
|
4
|
0
|
100-K05…K12
|
1
|
100-KFC40
|
100-KRFC40
|
|
|
0
|
2
|
100/104-K, 700-K
|
1
|
100-KFA02E
|
100-KRFA02E
|
|
1
|
1
|
100/104-K, 700-K
|
1
|
100-KFA11E
|
100-KRFA11E
|
|
2
|
0
|
100/104-K, 700-K
|
1
|
100-KFA20E
|
100-KRFA20E
|
|
|
0
|
4
|
100/104-K, 700-K
|
1
|
100-KFA04E
|
100-KRFA04E
|
|
1
|
3
|
100/104-K, 700-K
|
1
|
100-KFA13E
|
100-KRFA13E
|
|
2
|
2
|
100/104-K, 700-K
|
1
|
100-KFA22Z
|
100-KRFA22Z
|
|
3
|
1
|
100/104-K, 700-K
|
1
|
100-KFA31Z
|
100-KRFA31Z
|
|
4
|
0
|
100/104-K, 700-K
|
1
|
100-KFA40E
|
100-KRFA40E
|
|
|
|
|
Description
|
Connection Diagrams
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
Mechanical Interlock For interlocking of two adjacent contactors No added width to contactor assembly Front mount plug-in type Optional auxiliary contact blocks and suppressor modules mount onto the interlock
|
|
100/104-K/-KR, 700-K/-KR
|
1
|
100-KMCH
|
|
Surge Suppressor Plug-in type Limits surge voltage on coil drop-off
|
RC Suppressor
|
24…48V AC
|
|
100/104-K/-KR, 700-K/-KR
|
1 ⋆
|
100-KFSC50
|
| 110…280V AC
|
1 ⋆
|
100-KFSC280
|
| 380…480V AC
|
1 ⋆
|
100-KFSC480
|
| MOV Suppressor
|
12…55V AC, 12…77V DC
|
|
100/104-K/-KR, 700-K/-KR
|
1 ⋆
|
100-KFSV55
|
| 56…136V AC, 78…180V DC
|
1 ⋆
|
100-KFSV136
|
| 137…277V AC, 181…250V DC
|
1 ⋆
|
100-KFSV277
|
| Diode Suppressor
|
12…250V DC
|
|
100/104-K/-KR, 700-K/-KR
|
1 ⋆
|
100-KFSD250
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.
|
|
|
Description
|
|
Connection Diagrams
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
Solid-State Timing Element 110…250V AC or DC Includes 35 mm Hat Rail adapter
|
On-Delay, 0.1…3 s
|
|
100/104-K, 700-K
|
10
|
100-KT3S
|
On-Delay, 1…30 s
|
100-KT30S
|
|
|
|
|
Description
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
ECO Connecting Module — 12 A For DOL and reversing starters Eco-starters mount on single DIN Rail (140M on DIN Rail) Electrical and mechanical interconnection of 140M and 100-K contactors
|
Connects: 140M-C circuit breakers with 100-K contactors
|
140M-C to 100-K
|
1 ⋆
|
140M-C-PEK12
|
|
Power Wiring Kit For Reversing and Star/Delta combinations. Star-point bridge not included. Min. interruption time 50 ms
|
|
100-K
|
1
|
100-KPR
|
|
Feeder Terminal for Compact Bus Bars Max. current 34 A
|
Supply of compact bus bars
|
100-K
|
1
|
100-KWT
|
|
Three-Phase Compact Bus Bars Max. current 34 A
|
For 100-K, 5…12 A contactors 45 mm spacing (3 connections)
|
100-K
|
1
|
100-KW453
|
For 100-K, 5…12 A contactors 45 mm spacing (4 connections)
|
100-K
|
1
|
100-KW454
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 140M-C-PEK12M.
|
| Combinations possible. Example: For 6 contactor connections use one cat. no. 100-KW453 and one cat. no. 100-KW454.
|
|
|
Description
|
Pkg. Qty.
|
Cat. No.
|
|
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm
|
10
|
100-FMS
|
|
Snap-In Marker Card
|
5
|
1492-M6X12
|
|
|