Description
|
Connection Diagrams
|
|
|
For Use With
|
Pkg. Qty.
|
Screw Type Terminals
|
Spring Clamp Terminals
|
| N.O.
|
N.C.
|
Cat. No.
|
Cat. No.
|
|
Front-Mounted Auxiliary Contacts Auxiliary contact blocks 2- and 4-pole versions Choice of contact configurations Snap on, no tools required Electronic-compatible bifurcated contacts for signals down to 15V/2 mA Mirror Contact performance per IEC 60947-4-1
|
|
0
|
2
|
100-K05…K12
|
1
|
100-KFC02
|
100-KRFC02
|
|
1
|
1
|
100-K05…K12
|
1
|
100-KFC11
|
100-KRFC11
|
|
2
|
0
|
100-K05…K12
|
1
|
100-KFC20
|
100-KRFC20
|
|
|
0
|
4
|
100-K05…K12
|
1
|
100-KFC04
|
100-KRFC04
|
|
1
|
3
|
100-K05…K12
|
1
|
100-KFC13
|
100-KRFC13
|
|
3
|
1
|
100-K05…K12
|
1
|
100-KFC31
|
100-KRFC31
|
|
2
|
2
|
100-K05…K12
|
1
|
100-KFC22
|
100-KRFC22
|
|
4
|
0
|
100-K05…K12
|
1
|
100-KFC40
|
100-KRFC40
|
|
|
0
|
2
|
100/104-K, 700-K
|
1
|
100-KFA02E
|
100-KRFA02E
|
|
1
|
1
|
100/104-K, 700-K
|
1
|
100-KFA11E
|
100-KRFA11E
|
|
2
|
0
|
100/104-K, 700-K
|
1
|
100-KFA20E
|
100-KRFA20E
|
|
|
0
|
4
|
100/104-K, 700-K
|
1
|
100-KFA04E
|
100-KRFA04E
|
|
1
|
3
|
100/104-K, 700-K
|
1
|
100-KFA13E
|
100-KRFA13E
|
|
2
|
2
|
100/104-K, 700-K
|
1
|
100-KFA22Z
|
100-KRFA22Z
|
|
3
|
1
|
100/104-K, 700-K
|
1
|
100-KFA31Z
|
100-KRFA31Z
|
|
4
|
0
|
100/104-K, 700-K
|
1
|
100-KFA40E
|
100-KRFA40E
|
|
|
|
|
Description
|
Connection Diagrams
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
Mechanical Interlock For interlocking of two adjacent contactors No added width to contactor assembly Front mount plug-in type Optional auxiliary contact blocks and suppressor modules mount onto the interlock
|
|
100/104-K/-KR, 700-K/-KR
|
1
|
100-KMCH
|
|
Surge Suppressor Plug-in type Limits surge voltage on coil drop-off
|
RC Suppressor
|
24…48V AC
|
|
100/104-K/-KR, 700-K/-KR
|
1 ⋆
|
100-KFSC50
|
| 110…280V AC
|
1 ⋆
|
100-KFSC280
|
| 380…480V AC
|
1 ⋆
|
100-KFSC480
|
| MOV Suppressor
|
12…55V AC, 12…77V DC
|
|
100/104-K/-KR, 700-K/-KR
|
1 ⋆
|
100-KFSV55
|
| 56…136V AC, 78…180V DC
|
1 ⋆
|
100-KFSV136
|
| 137…277V AC, 181…250V DC
|
1 ⋆
|
100-KFSV277
|
| Diode Suppressor
|
12…250V DC
|
|
100/104-K/-KR, 700-K/-KR
|
1 ⋆
|
100-KFSD250
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.
|
|
|
Description
|
|
Connection Diagrams
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
Solid-State Timing Element 110…250V AC or DC Includes 35 mm Hat Rail adapter
|
On-Delay, 0.1…3 s
|
|
100/104-K, 700-K
|
10
|
100-KT3S
|
On-Delay, 1…30 s
|
100-KT30S
|
|
|
|
|
Description
|
For Use With
|
Pkg. Qty.
|
Cat. No.
|
|
ECO Connecting Module — 12 A For DOL and reversing starters Eco-starters mount on single DIN Rail (140M on DIN Rail) Electrical and mechanical interconnection of 140M and 100-K contactors
|
Connects: 140M-C circuit breakers with 100-K contactors
|
140M-C to 100-K
|
1 ⋆
|
140M-C-PEK12
|
|
Power Wiring Kit For Reversing and Star/Delta combinations. Star-point bridge not included. Min. interruption time 50 ms
|
|
100-K
|
1
|
100-KPR
|
|
Feeder Terminal for Compact Bus Bars Max. current 34 A
|
Supply of compact bus bars
|
100-K
|
1
|
100-KWT
|
|
Three-Phase Compact Bus Bars Max. current 34 A
|
For 100-K, 5…12 A contactors 45 mm spacing (3 connections)
|
100-K
|
1
|
100-KW453
|
For 100-K, 5…12 A contactors 45 mm spacing (4 connections)
|
100-K
|
1
|
100-KW454
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 140M-C-PEK12M.
|
| Combinations possible. Example: For 6 contactor connections use one cat. no. 100-KW453 and one cat. no. 100-KW454.
|
|
|
Description
|
Pkg. Qty.
|
Cat. No.
|
|
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm
|
10
|
100-FMS
|
|
Snap-In Marker Card
|
5
|
1492-M6X12
|
|
|
|
|
Description
|
|
|
Connection Diagrams
|
For Use With
|
Standard Auxiliary Contact Cat. No.§
|
Bifurcated Auxiliary Contact Cat. No.
|
| N.O.
|
N.C.
|
|
Auxiliary Contact Blocks for Front Mounting⋆ 2- and 4-pole Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 5 mA Mechanically linked performance between N.O. and N.C. poles and to the main contactor poles (except for L types) Models with equal function with several terminal numbering choices 1L = Late break N.C./early make N.O. Bifurcated version for switching down to 5V, 3 mA also available
|
0
|
2
|
|
100-C all
|
100-FA02
|
100-FAB02
|
| C30Ä00…C97Ä00
|
100-FB02
|
100-FBB02
|
| 1
|
1
|
100-C all
|
100-FA11
|
100-FAB11
|
| C30Ä00…C97Ä00
|
100-FB11
|
100-FBB11
|
| C09Ä10…C23Ä10
|
100-FC11
|
100-FCB11
|
| 2
|
0
|
100-C all
|
100-FA20
|
100-FAB20
|
| C30Ä00…C97Ä00
|
100-FB20
|
100-FBB20
|
| 1L
|
1L
|
100-C all
|
100-FAL11
|
—
|
| C30Ä00…C97Ä00
|
100-FBL11
|
—
|
|
0
|
4
|
100-C all
|
100-FA04
|
100-FAB04
|
| 1
|
3
|
100-C all
|
100-FA13
|
100-FAB13
|
| 2
|
2
|
100-C all
|
100-FA22
|
100-FAB22
|
| C30Ä00…C97Ä00
|
100-FB22
|
100-FBB22
|
| C09Ä10…C23Ä10
|
100-FC22
|
100-FCB22
|
| 3
|
1
|
100-C all
|
100-FA31
|
100-FAB31
|
| C09Ä10…C23Ä10
|
100-FC31
|
100-FCB31
|
| 4
|
0
|
100-C all
|
100-FA40
|
100-FAB40
|
| 1+1L
|
1+1L
|
100-C all
|
100-FAL22
|
—
|
|
Auxiliary Contact Blocks for Side Mounting without Sequence Terminal Designations⋆ 1- and 2-pole Two-way numbering for right or left mounting on the contactor Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 10 mA Mirror contact performance to the main contactor poles 1L = Late break N.C./early make N.O.
|
0
|
1
|
|
100-C all
|
100-SA01
|
—
|
1
|
0
|
100-C all
|
100-SA10
|
—
|
0
|
2
|
100-C all
|
100-SA02
|
—
|
|
1
|
1
|
100-C all
|
100-SA11
|
—
|
2
|
0
|
100-C all
|
100-SA20
|
—
|
1L
|
1L
|
100-C all
|
100-SAL11
|
—
|
|
Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations⋆ 1- and 2-pole Two-way numbering for right or left mounting on the contactor Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 10 mA Mirror contact performance to the main contactor poles 1L = Late break N.C./early make N.O.
|
0
|
1
|
|
100-C
|
100-SB01
|
—
|
1
|
0
|
100-C
|
100-SB10
|
—
|
0
|
2
|
100-C
|
100-SB02
|
—
|
|
1
|
1
|
100-C
|
100-SB11
|
—
|
2
|
0
|
100-C
|
100-SB20
|
—
|
1L
|
1L
|
100-C
|
100-SBL11
|
—
|
|
|
⋆ Max. number of auxiliary contacts that may be mounted: AC and 24V DC electronic coil contactors — max. 4 N.O. contacts on the front of the contactor, 2 N.O. contacts on the side, 4 N.C. front or side, 6 total. DC coil contactors — max. 4 N.O. contacts on the front of the contactor or max 2 N.O. contacts on the side, 4 N.C. front or side, 4 total.
|
| Double numbering — Left-side mounting only is recommended for Cat. No. 100-C09…100-C23 due to double numbering.
|
| § For screwless terminals (front mount only), insert "CR" after the "100-" in the catalog number. Example: Cat. No. 100-FA02 becomes Cat. No. 100-CRFA02.
|
|
|
Description
|
Connection Diagrams
|
For Use With
|
Cat. No.
|
|
Pneumatic Timing Modules Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.
|
On-Delay 0.3…30 s Range
|
|
100-C or 700-CF with AC coils or DC electronic coils§
|
100-FPTA30
|
| 2…180 s Range
|
100-FPTA180
|
Off-Delay 0.3…30 s Range
|
|
100-C all, 700-CF all
|
100-FPTB30
|
| 2…180 s Range
|
100-FPTB180
|
|
Electronic Timing Modules — On-Delay Delay of the contactor or control relay solenoid. The contactor or control relay is energized at the end of the delay time.
|
0.1…3 s Range
|
|
100-C or 700-CF with 110…240V, 50/60 Hz or 110…250V DC coils
|
100-ETA3
|
| 1…30 s Range
|
100-ETA30
|
| 10…180 s Range
|
100-ETA180
|
| 0.1…3 s Range
|
|
100-C or 700-CF with 24…48V DC coils
|
100-ETAZJ3
|
| 0.1…3 s Range
|
100-ETA3
|
| 10…180 s Range
|
100-ETAZJ180
|
|
Electronic Timing Modules — Off-Delay Delay of the contactor or control relay solenoid. After interruption of the control signal, the contactor or control relay is deenergized at the end of the delay time.
|
0.3…3 s Range
|
|
100-C09…C37 or 700-CF with 24V 50/60 Hz coils
|
100-ETBKJ3
|
| 1…30 s Range
|
100-ETBKJ30
|
| 10…180 s Range
|
100-ETBKJ180
|
| 0.3…3 s Range
|
100-C or 700-CF with 110…240V 50/60 Hz coils
|
100-ETB3
|
| 1…30 s Range
|
100-ETB30
|
| 10…180 s Range
|
100-ETB180
|
|
Electronic Timing Modules Delay of the contactor solenoid. Contactor K 3 (Y) is de-energized (off) and K 2 (D) is energized (on) after the end of the set Y end time. (Switching delay at 50 ms.) Continuous adjustment range High repeat accuracy
|
Transition Time Y Contactor 1…30 s Range
|
|
100-C with 110…240V, 50/60 Hz coils
|
100-ETY30
|
|
Mechanical Interlocks For interlocking of two contactors. Common interlock for all Bul. 100-C contactor sizes Interlocking of different sizes possible Mechanical and electrical interlocking possible in one module by means of integrated auxiliary contacts 9 mm dovetail connector included
|
Mechanical only, without auxiliary contacts
|
|
100-C (except 100-C40, -C90)
|
100-MCA00
|
| Mechanical/ electrical interlock with 2 N.C. auxiliary contacts
|
|
100-C (except 100-C40, -C90)
|
100-MCA02
|
|
Mechanical Latch Following contactor latching, the contactor coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66). Electrical or manual release 1 N.O. + 1 N.C. auxiliary contacts Suitable for all Bul. 100-C contactor sizes, 9…97 A
|
Maximum command duration 0.03…10 s
|
|
100-C with AC or 24V DC electronic coils (except 100-C90)
|
100-FL11Ä
|
|
|
| § Cannot be used with side-mounted auxiliary contacts on 700-CF DC relays.
|
| Voltage⋆ [V]
|
24
|
48
|
100
|
110
|
120
|
230…240
|
240
|
277
|
380…400
|
400…415
|
440
|
480
|
| 50 Hz
|
K
|
Y
|
KP
|
D
|
—
|
VA
|
KA
|
—
|
N
|
G
|
B
|
—
|
| 60 Hz
|
J
|
—
|
—
|
—
|
D
|
—
|
KA
|
T
|
—
|
—
|
N
|
B
|
|
|
| ⋆ For special voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
|
|
Description
|
Voltage Range
|
Connection Diagrams
|
For Use With
|
Cat. No.
|
DC Interface (Electronic) Interface between the DC control signal (PLC) and the AC operating mechanism of the contactor. Requires no additional surge suppression on the relay coils
|
Input: 12V DC Output: 110…240V AC
|
|
100-C with AC coils 110…240V AC
|
100-JE12
|
Input: 18…30V DC Output: 110…240V AC
|
100-JE
|
Input: 48V DC Output: 110…240V AC
|
100-JE48
|
|
Surge Suppressors For limitation of coil switching transients. Plug-in, coil mounted. Suitable for 100-C contactor sizes, 9…97 A. RC, varistor, and diode versions.
|
RC Module AC operating mechanism
|
24…48V AC, 50/60 Hz
|
|
100-C with AC coils
|
§
|
100-FSC48
|
| 110…280V AC, 50/60 Hz
|
§
|
100-FSC280
|
| 380…480V AC, 50/60 Hz
|
§
|
100-FSC480
|
Varistor Module AC/DC operating mechanism
|
12…55V AC/ 12…77V DC
|
|
100-C with AC coils or 100-C09…-C43 with DC coils
|
§
|
100-FSV55
|
| 56…136V AC/ 78…180V DC
|
§
|
100-FSV136
|
| 137…277V AC/ 181…350V DC
|
§
|
100-FSV277
|
| 278…575V AC
|
§
|
100-FSV575
|
Diode Module DC operating mechanism
|
12…250V DC
|
|
100-C09…-C43 with DC coils
|
§
|
100-FSD250
|
|
|
| § For screwless terminals, insert "CR" after the "100-" in the catalog number. Example: Cat. No. 100-FSC48 becomes Cat. No. 100-CRFSC48.
|
|
|
Description
|
For Use With
|
Pkg. Quantity
|
Cat. No.
|
|
Dovetail Connectors For use in contactor and starter assemblies. Single Connector — 0 mm Spacing
|
100-C
|
10
|
100-S0
|
| Cat. No. 100-S0
|
Dovetail Connectors For use in contactor and starter assemblies. Dual Connector — 9 mm Spacing
|
10
|
100-S9
|
|
Protective Covers Provides protection against unintended manual operation For contactors and front-mounted auxiliary contacts, pneumatic timers, and latches
|
100-C all
|
1
|
100-SCCA
|
| Cat. No. 100-SCCA
|
|
100-FA, -FB, -FC, -FP, -FL;
|
10
|
100-SCFA
|
| Cat. No. 100-SCFA
|
|
Reversing Power Wiring Kits For reversing connection with a solid-state or thermal overload relay
|
100-C09…C23
|
1
|
105-PW23
|
100-C30…C37
|
1
|
105-PW37
|
100-C43
|
1
|
105-PW43
|
| Cat. No. 105-PW23
|
100-C60…C97
|
1
|
105-PW85
|
|
DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m
|
140M-D 140M-F 100-C all
|
10
|
199-DR1
|
|
|
|
|
Description
|
Pkg. Qty.⋆
|
Cat. No.
|
|
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm
|
10
|
100-FMS
|
|
Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
|
10
|
100-FMP
|
Transparent Cover To be used with marking tag sheets
|
100
|
100-FMC
|
|
Marking Tag Adapters To be used with marking tag: System V4/V5
|
100
|
100-FMA1
|
Marking Tag Adapters To be used with marking tag: System 1492 W
|
100
|
100-FMA2
|
|
|
| ⋆ Must be ordered in multiples of package quantities.
|
|
|
Description
|
Max. Current Ratings and Wire Sizes
|
Pkg. Qty.⋆
|
Cat. No.
|
|
Stab Connector Kit Dual stab (0.250 in.) for 100-C coil terminals For 100-C09…C97 contactors
|
20
|
199-SC2
|
|
Stab Connector Kit Dual stab (0.250 in.) for 100-C power terminals For 100-C09…C23 contactors
|
100
|
199-SC10
|
|
3-Pole Terminal Lug Kit For Cat. No. 100-C09…C23 (Line side)
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
45 A (4…16 mm2 , fine stranded w/ ferrule) 45 A (4…25 mm2, coarse stranded/solid) 40 A (#10…4 AWG, stranded/solid)
|
1
|
100-CTN23
|
3-Pole Terminal Lug Kit For Cat. No. 100-C09…C23 (Load side)
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
45 A (4…16 mm2 , fine stranded w/ ferrule) 45 A (4…25 mm2, coarse stranded/solid) 40 A (#10…4 AWG, stranded/solid)
|
1
|
100-CTL23
|
3-Pole Terminal Lug Kit For Cat. No. 100-C30…C37 (Line and load side)
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
60 A (4…16 mm2 , fine stranded w/ ferrule) 60 A (4…25 mm2, coarse stranded/solid) 55 A (#10…4 AWG, stranded/solid)
|
1
|
100-CT37
|
|
1-Pole Terminal Lug Kit For Cat. No. 100-C43
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
90 A (6…35 mm2, fine stranded w/ ferrule) 90 A (6…50 mm2, coarse stranded/solid) 75 A (#8…2 AWG, stranded/solid)
|
3
|
100-CT43
|
1-Pole Terminal Lug Kit For Cat. No. 100-C60…C97
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
130 A (10…70 mm2, fine stranded w/ ferrule) 130 A (10…95 mm2, coarse stranded/solid) 130 A (#8…2/0 AWG, stranded/solid)
|
3
|
100-CT85
|
|
3-Pole Paralleling Kit For Cat. No. 100-C09…C23
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
100 A (35…70 mm2, fine stranded w/ ferrule) 100 A (35…95 mm2, coarse stranded/solid) 100 A (#0…2/0 AWG, stranded/solid)
|
2
|
100-CP23
|
3-Pole Paralleling Kit For Cat. No. 100-C30…C37
|
IEC @ 40 °C IEC @ 40 °C UL/CSA (Encl.)
|
150 A (35…70 mm2, fine stranded w/ ferrule) 150 A (35…95 mm2, coarse stranded/solid) 150 A (#0…2/0 AWG, stranded/solid)
|
2
|
100-CP37
|
|
|
| ⋆ Must be ordered in multiples of the package quantity.
|
| 16 mm2 max. according to IEC 60947; actual max. 25 mm2.
|
|
|
Description
|
Input Voltage
|
For Use With§
|
Options
|
Cat. No.
|
|
SEMI-F47 Module Meets SEMI-F47 voltage sag immunity requirements Direct mounting to coil terminals of 100-C contactors and 700-CF control relays Requires DC coil contactor Optional 1…30 s ON-delay timer version
|
24…240V AC
|
100-C09…C97 700-CF
|
without timer
|
100-CSF47
|
| 110…240V AC
|
100-C09…C97 700-CF
|
with 1…30 s ON-delay timer
|
100-CSF47A30
|
|
|
| § Contactor must have DC coil at the same voltage as AC input. Example: for 24V AC control, select Cat. No. 100-C09ZJ10 (24V DC coil).
|
|
|
|
Description
|
|
|
Connection Diagram
|
For Use With
|
Standard Auxiliary Contact Cat. No.
|
Bifurcated Cat. No.
|
| No. of N.O. Contacts
|
No. of N.C. Contacts
|
|
|
Auxiliary Contacts Side-mounted Without IEC sequence terminal designations Standard contacts 17V/10 mA Bifurcated contacts for signals down to 5V/2 mA
|
1
|
1
|
|
100-D left or right inside mounting
|
100-DS1-11
|
100-DS1-B11H
|
| 1
|
1
|
|
100-D left or right outside mounting
|
100-DS2-11
|
100-DS2-B11H
|
| 1
|
1L
|
|
100-D left or right inside mounting
|
100-DS1-L11
|
—
|
| 2
|
0
|
|
100-D left or right inside mounting
|
100-DS1-20
|
100-DS1-B20H
|
| 2
|
0
|
|
100-D left or right outside mounting
|
100-DS2-20
|
100-DS2-B20H
|
Auxiliary Contacts Electronic-compatible auxiliary contacts Ideal for use when switching low-power control circuits With IEC sequence terminal designations Contact ratings: AC-12, 250V, 0.1 A AC-15, DC-13, 3...125V, 1...100 mA
|
1
|
1
|
|
100-D left or right inside mounting
|
100-DS1-B11
|
—
|
Auxiliary Contacts Side-mounted Without IEC sequence terminal designations Standard contacts 17V/10 mA Bifurcated contacts for signals down to 5V/2 mA
|
1
|
1
|
|
100-D left or right inside mounting
|
100-DS0-11
|
100-DS0-B11H
|
| 2
|
0
|
|
100-D left or right inside mounting
|
100-DS0-20
|
100-DS0-B20H
|
| 1
|
1L
|
|
100-D left or right inside mounting
|
100-DS0-L11
|
—
|
Auxiliary Contacts Electronic-compatible auxiliary contacts Ideal for use when switching low-power control circuits Without IEC sequence terminal designations Contact ratings: AC-12, 250V, 0.1 A AC-15, DC-13, 3...125V, 1...100 mA
|
1
|
1
|
|
100-D left or right inside mounting
|
100-DS0-B11
|
—
|
|
|
|
|
Description
|
Pkg. Qty.⋆
|
Cat. No.
|
|
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm
|
10
|
100-FMS
|
|
Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
|
10
|
100-FMP
|
Transparent Cover To be used with marking tag sheets
|
100
|
100-FMC
|
|
Marking Tag Adapters To be used with marking tag: System V4/V5
|
100
|
100-FMA1
|
Marking Tag Adapters To be used with marking tag: System 1492 W
|
100
|
100-FMA2
|
|
|
| ⋆ Must be ordered in multiples of package quantities.
|
|
|
Description
|
Connection Diagram
|
Suppressor Rating
|
For Use With
|
Cat. No.
|
|
Suppressor Module for Bul. 100-D Contactors For limiting surge voltage when coil circuits are interrupted Supplied as standard on all conventional DC coil contactors and all electronic coil contactors (as part of the supply module or delivered with separate suppressor module)
|
|
RC Module (AC control) for contactors with conventional coil 21...48V, 50 Hz; 24...55V, 60 Hz
|
100-D115...100-D180
|
100-DFSC48
|
| 95...110V, 50 Hz; 110...127V, 60 Hz
|
100-DFSC110
|
| 180...277V, 50 Hz; 208...277V, 60 Hz
|
100-DFSC240
|
| 380...550V, 50 Hz; 440...600V, 60 Hz
|
100-DFSC550
|
|
Varistor Module for contactors with conventional coil 55V AC
|
100-D115...100-D420
|
100-DFSV55
|
| 56...136V AC
|
100-DFSV136
|
| 137...277V AC
|
100-DFSV277
|
| 278...600V AC
|
100-DFSV575
|
Varistor Module for contactors with electronic coil 208...277V AC⋆
|
100-D115...100-D420
|
100-DFSV550
|
| 380...500V AC
|
100-D115...100-D300
|
100-DFSV500
|
|
|
| ⋆ For overvoltage category IV (IEC 947 for 100-D...-EI) e.g., lightning protection requirements.
|
| For surge pulse >1 kV
|
| Package Quantity = 1
|
|
|
Description
|
Cross-section
|
For Use With
|
Terminal Connection
|
Cat. No.
|
| 100-D115…180
|
100-D210…420
|
100-D630…860
|
|
Reversing: Input Connection Wye-Delta: Main-Delta connection
|
50 mm2
|
X
|
|
|
Terminal Blocks, 100-DTB… Lugs, 100-DL…
|
100-D180-VLTB
|
| 120 mm2
|
|
X
|
|
100-D420-VLTB
|
| 350 mm2
|
|
|
X
|
Lugs, 100-DL…
|
100-D860-VL
|
|
Reversing: Output Connection Wye-Delta: Delta-Wye connection
|
50 mm2
|
X
|
|
|
Lugs, 100-DL…
|
100-D180-VT
|
| 120 mm2
|
|
X
|
|
100-D420-VT
|
350 mm2
|
|
|
X
|
100-D860-VT
|
|
50 mm2
|
X
|
|
|
Terminal Blocks, 100-DTB…
|
100-D180-VTTB
|
|
Delta-Wye connection if 100-D115…180 is used as a Wye contactor
|
80 mm2
|
—
|
X
|
|
Terminal Blocks, 100-DTB…
|
100-D420-VYTB
|
|
Wye-Delta: Neutral bridge
|
—
|
X
|
|
|
—
|
100-D180-VYU
|
| —
|
|
X
|
|
—
|
100-D420-VYU
|
| —
|
|
|
X
|
—
|
100-D860-VYU
|
|
Power Wiring Kits (for contactors using 100-DL lug kits)
|
For 100-D115…D100-D180
|
Reversing
|
100-DPW180
|
| Two-speed, or changeover
|
100-D180-VLTB
|
| Wye-Delta/Star-Delta
|
100-DPY180
|
For 100-D210…100-D420 Reversing Two-speed, or changeover Wye-Delta/Star-Delta
|
100-DPW420 100-D420-VLTB 100-DPY420
|
For 100-D630…100-D860 Reversing Two-speed, or changeover
|
100-DPW860 100-D860-VL
|
|
|
| Package Quantity = 1
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Terminal Lugs Set of two Protection class IP2X per IEC 60529 and DIN 40 050
|
100-D115, 100-D140, 100-D180, 100-D115E…D180E, 193-EC_F, 193-EE_F
|
100-DTB180
|
| 100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G
|
100-DTB420
|
|
Terminal Lugs (UL/CSA), Copper Frame Set of three
|
100-D115, 100-D140, 100-D180, 193-EC_F, 193-EE_F
|
100-DL180
|
| 100-D210…100-D420, 193-EC_G, 193-EE_G
|
100-DL420
|
| 100-D630, 100-D860, 193-EC_H, 193-EE_H
|
100-DL630
|
| 100-D630, 100-D860, 193-EC_H, 193-EE_H
|
100-DL860
|
|
Control Circuit Terminal 2 x 2.5 mm2
|
Connects to Cat. Nos. 100-D115...D180
|
100-DAT1
|
| Connects to Cat. Nos. 100-D210...D420
|
100-DAT2
|
|
Terminal Shields Set of two Protection class IP10 per IEC 60529 and DIN 40 050 For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
|
100-D115…100-D180, 193-FE
|
100-DTS180
|
| 100-D210...100-D420, 193-FE
|
100-DTS420
|
|
Terminal Covers Protection class IP20 per IEC 60529 and DIN 40 050 For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
|
100-D115…100-D180, 193-EC_F, 193-EE_F
|
100-DTC180
|
| 100-D210...100-D420, 193-EC_G, 193-EE_G
|
100-DTC420
|
| 100-D630…100-D860, 193-EC_H, 193-EE_H
|
100-DTC860
|
Terminal Covers Line-side panel relay and reversing cover
|
100-D630…100-D860, 193-EC_H, 193-EE_H
|
100-DTCE860
|
Terminal Covers Reversing starter/relay cover
|
100-DTCR860
|
Terminal Covers DOL Starter/relay cover
|
100-DTCS860
|
|
Mounting Plate Galvanized steel plate for starter combinations For direct-on-line, reversing, two-speed, wye-delta/ star-delta, and Dahlander assemblies
|
100-D115...100-D180
|
Direct-on-line
|
100-DMS180
|
| Reversing, two-speed or changeover
|
100-DMU180
|
| Y-D or Dahlander
|
100-DMY180
|
| 100-D210...100-D420
|
Direct-on-line
|
100-DMS420
|
| Reversing, two-speed or changeover
|
100-DMU420
|
| Y-D or Dahlander
|
100-DMY420
|
| 100-D630...100-D860
|
Direct-on-line
|
100-DMS860
|
| Reversing, two-speed or changeover
|
100-DMU860
|
| Y-D or Dahlander
|
100-DMY860
|
Mounting Plate For two-speed or changeover switches
|
For interlocking between 100-C60…C97 and 100-D115…D180 contactors
|
100-DMU85
|
|
|
| Package Quantity = 2
|
|
|
Description
|
Circuit Diagram
|
For Use With
|
Cat. No.
|
|
Interlock — Mechanical Only No additional space required
|
|
100-D115…100-D420
|
100-DMA00
|
|
Interlock — Dual Electrical/Mechanical No additional space required Two N.C. auxiliary contacts
|
|
100-D115…100-D860
|
100-DMD02
|
Interlock — Mechanical Only No additional space required
|
|
100-D115…100-D860
|
100-DMD00
|
Interlock — Mechanical Only Provides interlocking between Bul. 100-C and Bul. 100-D contactors
|
|
100-C60…100-C97 between 100-D115…100-D180
|
100-DMC00
|
Interlock — Dual Electrical/Mechanical Provides interlocking between Bul. 100-C and Bul. 100-D contactors Two N.C. auxiliary contacts
|
|
100-C60…100-C97 between 100-D115…100-D180
|
100-DMC02
|
|
|
| Package Quantity = 1
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Auxiliary Contact Block For mounting between T1 & T2 or between T2 & T3 Adjustable; provides normal, delayed, or overlapping contacts Max. two blocks/contactor Alternate terminal marking tags included 2 N.O. and 2 N.C. contacts
|
|
100-G550…100-G860
|
100-EF22
|
| Standard Terminal marking for mounting between T1 & T2
|
|
| Alternate terminal marking for mounting between T2 & T3
|
| 4-Pole
|
|
Auxiliary Contact Block For side mounting on either side of the contactor Max. four blocks/contactor Alternate terminal marking tags included 1 N.O. and 1 N.C. contact
|
|
100-G1000…100-G1200
|
100-EB11
|
| Standard terminal marking
|
|
|
| Alternate terminal markings
|
| 2-Pole
|
|
Fourth Add-On Neutral Switching Pole Left- or right-side mountable Note: no UL/cUL
|
Ith AC-1 500 A
|
100-G550
|
100-NP800-5
|
| 100-G700, 100-G860
|
100-NP500-6
|
| Ith AC-1 1000A
|
100-G700, 100-G860
|
100-NP1000-6
|
| 100-G1000, 100-G1200
|
100-NP1000-7
|
|
Mechanical Latch Mechanical life: 0.5 million operations Direct and Impulse Control
|
Direct and Impulse Contact control
|
100-G550
|
100-FLAM5Ä
|
| Direct and Impulse Contact control
|
100-G700, 100-G860
|
100-FLAM6Ä
|
|
Mechanical Interlock — Horizontal
|
100-G550 to 100-G550
|
100-MC00-5H
|
| 100-G550 to 100-G700 or 100-G860
|
100-MC00-56H
|
| 100-G700 or 100-G860 to 100-G700 or 100-G860
|
100-MC00-6H
|
| 100-G700 or 100-G860 to 100-G1000 or 100-G1200
|
100-MC00-67H
|
| 100-G1000 or 100-G1200 to 100-G1000 or 100-G1200
|
100-MC00-7H
|
|
Mechanical Interlock — Vertical
|
100-G550 to 100-G550
|
100-MC00-5V
|
| 100-G550 to 100-G700 or 100-G860
|
100-MC00-56V
|
| 100-G700 or 100-G860 to 100-G700 or 100-G860
|
100-MC00-6V
|
| 100-G700 or 100-G860 to 100-G1000 or 100-G1200
|
100-MC00-67V
|
| 100-G1000 or 100-G1200 to 100-G1000 or 100-G1200
|
100-MC00-7V
|
|
|
| Package Quantity = 1
|
| For use with
|
[V]
|
110...120
|
220...240
|
380...415
|
440...480
|
| 100-G550... 100-G860
|
50-60 Hz
|
KD
|
KF
|
KN
|
KB
|
|
|
| ⋆ For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
|
|
Description
|
For Use With Bulletin No.
|
Enclosure Type
|
Cat. No.
|
Red "ON" Pilot Light⋆ Full Voltage Type
|
120V
|
All
|
Metal Lift-off, Metal Hinged, and Molded Plastic
|
|
198-PL21R
|
| 208V
|
|
198-PL25R
|
| 240V
|
|
198-PL22R
|
| 24V
|
103H
|
Metal Hinged
|
|
198-PL26R
|
| 120V
|
|
198-PL27R
|
| 240V
|
|
198-PL28R
|
|
Green Pilot Light⋆ Full Voltage Type
|
24V
|
All
|
Metal Lift-off, Metal Hinged, and Molded Plastic
|
|
198-PL26G
|
| 120V
|
All
|
|
198-PL21G
|
| 240V
|
All
|
|
198-PL22G
|
|
Dual "ON" Pilot Light⋆ Forward — Red Reverse — White Full Voltage Type
|
120V
|
105, 106
|
Metal Hinged
|
198-PL21RW
|
| 240V
|
198-PL22RW
|
|
Pilot Device Mounting Bracket (required when mounting pilot devices in metal lift-off enclosures)
|
105, 109
|
Metal Lift-off
|
198-BR1
|
|
Control Circuit Fuse Block For Class CC rejection type fuses (fuses not included)
|
All
|
Metal Lift-off and Metal Hinged
|
1491-R162
|
|
Grounding Bushing Adapts to 1/2 in. N.P.T., PG 16.5 & BS20 mm threads
|
109
|
Molded Plastic
|
198-GR1
|
|
Single Pole N.O. Auxiliary Contact for Disconnect Switch
|
106, 112
|
Metal Hinged
|
§
|
195-GA10
|
|
Closing Button For 22.5mm Round Panel Hole
|
All
|
All
|
198-N1
|
|
"OFF-ON" Selector Switch 2-Position Maintained
|
All
|
Metal Lift-off and Metal Hinged
|
|
198-MT3
|
|
|
| ⋆ Does not include legend plate. See Two-Color Molded Legend Caps — Non-Illuminated Push Buttons for Bulletin 800F Legend Plate. Legend Plates for use on metal-hinged enclosures only.
|
| Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures.
|
| § An auxiliary contact adaptor, Cat. No. 194R-AA, is required when installing auxiliary contact, Cat. No. 195-GA10.
|
| ♣ 3 required for disconnect switch.
|
|
Description
|
For Use With Bulletin No.
|
Enclosure Type
|
Cat. No.
|
"HAND-OFF-AUTO" Selector Switch 3-Position Maintained, Includes Legend Plate
|
105, 106, 109, 112, 113
|
Metal Lift-off and Metal Hinged
|
⋆
|
198-MT1
|
| 103H
|
Metal Hinged
|
198-MT4
|
"FORWARD-OFF-REVERSE" Selector Switch 3-Position Maintained
|
105, 106
|
Metal Lift-off and Metal Hinged
|
⋆
|
198-MT2
|
|
"START-STOP" Push Button Flush green "I/START" Extended red "O/STOP"
|
105, 109
|
Metal Lift-off
|
⋆
|
198-MS3
|
| 103H
|
Metal Hinged
|
198-MS23
|
|
"START" Push Button Flush green "START"
|
All
|
Metal Hinged
|
198-MS13
|
|
"ON-OFF" Push Button
|
105, 109
|
Metal Lift-off
|
⋆
|
198-MS6
|
|
"FORWARD, REVERSE-STOP" Push Button
|
105
|
Metal Lift-off
|
⋆
|
198-MS7
|
|
"STOP" Push Button Flush red "STOP"
|
All
|
Metal Hinged
|
198-MS14
|
|
"ON" Push Button Flush green "ON"
|
All
|
Metal Hinged
|
198-MS15
|
|
"OFF" Push Button Flush red "OFF"
|
All
|
Metal Hinged
|
198-MS16
|
|
"FORWARD, REVERSE-STOP" Push Buttons
|
105, 106
|
Metal Hinged
|
198-MS17
|
|
"START" Push Button Flush green "START" and "STOP" Push Button Flush red "STOP"
|
103H
|
Metal Hinged
|
198-MS22
|
|
|
"RESET" Push Button
|
All
|
Metal Lift-off and Metal Hinged
|
|
198-MR3
|
|
|
Wiring Kit for Starters IEC ModCenter
|
103H
|
—
|
198-W103H
|
| 109
|
—
|
198-W109
|
| 112
|
—
|
198-W112
|
Wiring Kit for Transformers IEC ModCenter
|
103H
|
—
|
198-WT2
|
| 109, 112
|
—
|
198-WT1
|
|
|
| ⋆ Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures.
|
| Requires reset adapter Cat. No. 193-RA3 for 193-T1 bimetallic overload relay and reset adapter Cat. No. 193-ERA for Bulletin 193 E1 Plus electronic overload relay.
|