Contactors

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Contactors > Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors

Introduction Standards Compliance and Certifications Product Selection Bulletin 100-D/104-D Accessories
Bulletin 100/104-K, 100/104-C, 100/104-D, 100S/104S-C, 100S-D Specifications Bulletin 100-D/104-D Life-Load Curves Bulletin 100-D Approximate Dimensions Renewal Parts
Bulletin 100-D/104-D Accessories

Auxiliary Contacts

    Description Click to enlarge - 100M-66-3 Click to enlarge - 100M-66-4 Connection Diagram For Use With Standard Auxiliary Contact
Cat. No.
Bifurcated Auxiliary Contact
Cat. No.
No. of N.O. Contacts No. of N.C. Contacts
Click to enlarge - 100-DS_GS Click to enlarge - 100-MCA00_GS Auxiliary Contacts
Side-mounted
With IEC sequence terminal designations
Standard contacts 17V/10 mA
Bifurcated contacts for signals down to 5V/2 mA
1 1 Click to enlarge - 100D-91-5 100-D left or right inside mounting 100-DS1-11 100-DS1-B11H
1 1 Click to enlarge - 100D-91-6 100-D Left or Right Inside Mounting 100-DS2-11 100-DS2-B11H
1 1L Click to enlarge - 100-DS1-L11_Dia 100-D left or right inside mounting 100-DS1-L11
2 0 Click to enlarge - 100D-91-8 100-D left or right inside mounting 100-DS1-20 100-DS1-B20H
2 0 Click to enlarge - 100D-91-9 100-D left or right outside mounting 100-DS2-20 100-DS2-B20H
Auxiliary Contacts
Electronically compatible auxiliary contacts
Ideal for use when switching low-power control circuits
With IEC sequence terminal designations
Contact ratings:
AC-12, 250V, 0.1 A
AC-15, DC-13, 3...125V, 1...100 mA
1 1 Click to enlarge - 100D-91-10 100-D left or right inside mounting 100-DS1-B11
Auxiliary Contacts
Side-mounted
Without IEC sequence terminal designations
Standard contacts 17V/10 mA
Bifurcated contacts for signals down to 5V/2 mA
1 1 Click to enlarge - 100-DS0-11 100-D left or right inside mounting 100-DS0-11 100-DS0-B11H
2 0 Click to enlarge - 100-DS0-20_Dia 100-D left or right inside mounting 100-DS0-20 100-DS0-B20H
1 1L Click to enlarge - 100-DS0-L11_Dia 100-D left or right inside mounting 100-DS0-L11
Auxiliary Contacts
Electronically compatible auxiliary contacts
Ideal for use when switching low-power control circuits
Without IEC sequence terminal designations
Contact ratings:
AC-12, 250V, 0.1 A
AC-15, DC-13, 3...125V, 1...100 mA
1 1 Click to enlarge - 100-DS0-B11 100-D left or right inside mounting 100-DS0-B11
  

Marking Systems (For 100-D95…D860 contactors)

  Description Pkg. Qty.¬  Cat. No.
Click to enlarge - 100-C_104-C-89-2 Label Sheet
105 self-adhesive paper labels each, 6 x 17 mm
10 100-FMS
Click to enlarge - 100-C_104-C-89-3 Marking Tag Sheet
160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
10 100-FMP
Transparent Cover
To be used with marking tag sheets
100 100-FMC
Click to enlarge - 100-FMA1 Marking Tag Adapters
To be used with marking tag: System V4/V5
100 100-FMA1
Marking Tag Adapters
To be used with marking tag: System 1492 W
100 100-FMA2
  
¬ Must be ordered in multiples of package quantities.

Suppressor Modules

  Description Connection Diagram Suppressor Rating For Use With Cat. No.
Click to enlarge - 100-DFSC48_GS Suppressor Module for Bul. 100-D Contactors
•   For limiting surge voltage when coil circuits are interrupted
•   Supplied as standard on all conventional DC coil contactors and all electronic coil contactors (as part of the supply module or delivered with separate suppressor module)
Click to enlarge - 100D-92-2 RC Module (AC control)
for contactors with conventional coil
21...48V, 50 Hz; 24...55V, 60 Hz
100-D95...100-D180   

100-DFSC48
95...110V, 50 Hz; 110...127V, 60 Hz 100-DFSC110
180...277V, 50 Hz; 208...277V, 60 Hz 100-DFSC240
380...550V, 50 Hz; 440...600V, 60 Hz 100-DFSC550
Click to enlarge - 100D-92-3 Varistor Module
for contactors with conventional coil
55V AC
100-D95...100-D180   

100-DFSV55
56...136V AC 100-DFSV136
137...277V AC 100-DFSV277
278...600V AC 100-DFSV575
208...277V AC¬  100-D95...100-D180 100-DFSV550
  
¬ For overvoltage category IV (IEC 947 for 100-D...-EI) e.g., lightning protection requirements.
Package Quantity = 1

Connecting Components

  Description Output
Connection
For Use With Terminal
Connection
Cat. No.
100-D95…180 100-D210…420 100-D630…860
Click to enlarge - 100-D180_VL Reversing: Input Connection
Wye-Delta: Main-Delta connection
50 mm2 X     Lugs, 100-DL… 100-D180-VL
120 mm2   X   100-D420-VL
350 mm2     X 100-D860-VL
Click to enlarge - 100-D180_VLTB 50 mm2 X     Terminal Blocks,
100-DTB…
100-D180-VLTB
120 mm2   X   100-D420-VLTB
Click to enlarge - 100-D180_VT Reversing: Output Connection
Wye-Delta: Delta-Wye connection
50 mm2 X     Lugs, 100-DL… 100-D180-VT
120 mm2   X   100-D420-VT
350 mm2
    X 100-D860-VT
Click to enlarge - 100-D180_VTTB 50 mm2
X     Terminal Blocks,
100-DTB…
100-D180-VTTB
120 mm2   X   100-D420-VTTB
Click to enlarge - 100-D420_VYTB Delta-Wye connection if 100-D95…180 is used as a Wye contactor 80 mm2 X   Terminal Blocks,
100-DTB…
100-D420-VYTB
Click to enlarge - 100-D180_VYU Wye-Delta: Neutral bridge X     100-D180-VYU
  X   100-D420-VYU
    X 100-D860-VYU
Click to enlarge - 100D_Acc_PowerWiringKits Power Wiring Kits (for contactors using 100-DL lug kits) For 100-D95…D100-D180
  • Reversing

  • Two-speed, or changeover

  • Wye-Delta/Star-Delta
  • 100-DPW180
    100-D180-VL
    100-DPY180
    For D100-D210…100-D420
  • Reversing

  • Two-speed, or changeover

  • Wye-Delta/Star-Delta
  • 100-DPW420
    100-D420-VL
    100-DPY420
    For 100-D630…100-D860
  • Reversing

  • Two-speed, or changeover
  • 100-DPW860
    100-D860-VL
      
    Package Quantity = 1

      Description For Use With Cat. No.
    Click to enlarge - 100-DTB_GS Terminal Lugs
    Set of two
    Protection class IP2X per IEC 60529 and DIN 40 050
    100-D95, 100-D110 100-DTB110
    100-D140, 100-D180, 100-D95E…D180E, 193-EC_F, 193-EE_F 100-DTB180
    100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G 100-DTB420
    Click to enlarge - 100D-93-2 Terminal Lugs (UL/CSA), Copper Frame
    Set of three
    100-D95, 100-D110 100-DL110
    100-D95E, 100-D110E, 193-EC_F, 193-EE_F 100-DLE110
    100-D140, 100-D180, 193-EC_F, 193-EE_F 100-DL180
    100-D210…100-D420, 193-EC_G, 193-EE_G 100-DL420
    100-D630, 100-D860, 193-EC_H, 193-EE_H 100-DL630
    100-D630, 100-D860, 193-EC_H, 193-EE_H 100-DL860
    Click to enlarge - 100D-93-3 Control Circuit Terminal
    2 x 2.5 mm2
    Connects to Cat. Nos. 100-D95...D180 100-DAT1
    Connects to Cat. Nos. 100-D210...D420 100-DAT2
    Click to enlarge - 100-DTS_GS Terminal Shields
    Set of two
    Protection class IP10 per IEC 60529 and DIN 40 050
    For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
    100-D95, 100-D110 100-DTS110
    100-D140, 100-D180, 100-D95-E…100-D180-E 100-DTS180
    100-D210...100-D420 100-DTS420
    Click to enlarge - 100D-93-5 Terminal Covers
    Protection class IP20 per IEC 60529 and DIN 40 050
    For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
    100-D95…100-D180, 193-EC_F, 193-EE_F 100-DTC180
    100-D210...100-D420, 193-EC_G, 193-EE_G 100-DTC420
    100-D630…100-D860, 193-EC_H, 193-EE_H 100-DTC860
    Terminal Covers
    Line-side panel relay and reversing cover
    100-D630…100-D860, 193-EC_H, 193-EE_H 100-DTCE860
    Terminal Covers
    Reversing starter/relay cover
    100-DTCR860
    Terminal Covers
    DOL Starter/relay cover
    100-DTCS860
    Click to enlarge - Backplate-17335_gs Mounting Plate
    Galvanized steel plate for starter combinations
    For direct-on-line, reversing, two-speed, wye-delta/
    star-delta, and Dahlander assemblies
    100-D95...100-D180 Direct-on-line 100-DMS180
    Reversing, two-speed or changeover 100-DMU180
    Y-D or Dahlander 100-DMY180
    100-D210...100-D420 Direct-on-line 100-DMS420
    Reversing, two-speed or changeover 100-DMU420
    Y-D or Dahlander 100-DMY420
    100-D630...100-D860 Direct-on-line 100-DMS860
    Reversing, two-speed or changeover 100-DMU860
    Y-D or Dahlander 100-DMY860
    Mounting Plate
    For two-speed or changeover switches
    For interlocking between 100-C60…C85 and 100-D95…D180 contactors 100-DMU85
      
    Package Quantity = 2

    Interlocks

      Description Circuit Diagram For Use With Cat. No.
    Click to enlarge - 100-DMA00_GS Interlock — Mechanical Only
    No additional space required
    Click to enlarge - 100-KMHC_Dia 100-D95…100-D420 100-DMA00
    Click to enlarge - 100-DMD02 Interlock — Dual Electrical/Mechanical
    No additional space required
    Two N.C. auxiliary contacts
    Click to enlarge - 100D-93-11 100-D95…100-D860 100-DMD02
    Interlock — Mechanical Only
    No additional space required
    Click to enlarge - 100d_interlock-diagram 100-D95…100-D860 100-DMD00
    Interlock — Mechanical Only
    Provides interlocking between Bul. 100-C and Bul. 100-D contactors
    Click to enlarge - 100d_interlock-diagram 100-C60…100-C85 between 100-D95…100-D180 100-DMC00
    Interlock — Dual Electrical/Mechanical
    Provides interlocking between Bul. 100-C and Bul. 100-D contactors
    Two N.C. auxiliary contacts
    Click to enlarge - 100D-93-11 100-C60…100-C85 between 100-D95…100-D180 100-DMC02
      
    Package Quantity = 1