Contactors

Catalogs > Industrial Controls Catalog > Motor Control, IEC > Contactors > Bulletin 100-K Miniature Contactors

Bulletin 100-K Miniature Contactors

Introduction Standards Compliance and Certifications Product Selection Assignment of Contacts
Accessories Bulletin 100/104-K, 100/104-C, 100/104-D, 100S/104S-C, 100S-D Specifications Bulletin 100-K/104-K Life-Load Curves Approximate Dimensions
Product Selection

3-Pole AC- and DC-Operated Contactors

Rated Operational Current Ie [A] Ratings for switching AC motors - AC-2, AC-3, AC-4 Auxiliary Contacts Pkg. Qty.¬  Cat. No.
3Æ kW (50 Hz) Hp (60 Hz) Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a
40 °C 230V 400/415V 500V 690V 1Æ 3Æ
AC-1 115V 230V 200V 230V 460V 575V N.O. N.C.
20 1.5 2.2 2.2 2.2 1/2 1 1-1/2 1-1/2 3 3 1 0 1 100-K05Ä10
0 1 1 100-K05Ä01
20 3 4 4 4 1/2 1-1/2 2 2 5 5 1 0 1 100-K09Ä10
0 1 1 100-K09Ä01
20 3 5.5 5.5 5.5 3/4 2 3 3 7-1/2 7-1/2 1 0 1 100-K12Ä10
0 1 1 100-K12Ä01
  
¬ May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 100-K09ZJ10M.
Ä The Cat. No. as listed is incomplete. Select a Coil Voltage Code from Ä Coil Voltage Code to complete the Cat. No.
    Example: 24V DC: Cat. No. 100-K05Ä10 becomes Cat. No. 100-K05ZJ10.

4-Pole AC- and DC-Operated Contactors

Rated Operational Current Ie [A] Ratings for switching AC motors - AC-2, AC-3 Contact Configuration, Main Pole Pkg. Qty.¬  Cat. No.
3Æ kW (50 Hz) Hp (60 Hz) Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a
40 °C 230V 400/415V 500V 690V 1Æ 3Æ
AC-1 115V 230V 200V 230V 460V 575V N.O. N.C.
20 1.5 2.2 2.2 2.2 1/2 1 1-1/2 1-1/2 3 3 4 0 1 100-K05Ä400
3 1 1 100-K05Ä300
2 2 1 100-K05Ä200
20 3 4 4 4 1/2 1-1/2 2 2 5 5 4 0 1 100-K09Ä400
3 1 1 100-K09Ä300
2 2 1 100-K09Ä200
20 3 5.5 5.5 5.5 3/4 2 3 3 7-1/2 7-1/2 4 0 1 100-K12Ä400
3 1 1 100-K12Ä300
2 2 1 100-K12Ä200
  
¬ May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 100-K09ZJ400M.
Ä The Cat. No. as listed is incomplete. Select a Coil Voltage Code from Ä Coil Voltage Code to complete the Cat. No.
    Example: 24V DC: Cat. No. 100-K05Ä400 becomes Cat. No. 100-K05ZJ400.

Reversing AC- and DC-Operated Contactors

Rated Operational Current Ie [A] Ratings for switching AC motors - AC-2, AC-3, AC-4 Auxiliary Contacts per Contactor ¬  Cat. No.
3Æ kW (50 Hz) Hp (60 Hz) Click to enlarge - 100M-66-3a Click to enlarge - 100M-66-4a
40 °C 230V 400/415V 500V 690V 1Æ 3Æ
AC-1 115V 230V 200V 230V 460V 575V N.O. N.C.
20 1.5 2.2 2.2 2.2 1-1/2 1-1/2 3 3 0 1 104-K05Ä02
20 3 4 4 4 2 2 5 5 0 1 104-K09Ä02
20 3 5.5 5.5 5.5 3 3 7-1/2 7-1/2 0 1 104-K12Ä02
  
¬ Used for electrical interlocking
Ä The Cat. No. as listed is incomplete. Select a standard Coil Voltage Code from Ä Coil Voltage Code to complete the Cat. No.
    Example: 230V, 50/60 Hz: Cat. No. 104-K05Ä02 becomes Cat. No. 104-K05KF02.
Bulletin 104-K reversing contactors are factory assembled and include contactors, mechanical interlock (Cat. No. 100-KMCH) and wiring kit (Cat. No. 100-KPR) for power and control circuit (electrical interlock). Wiring schematic see 100-KPR

Ä Coil Voltage Code

The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz:
Cat. No. 100-K09Ä10 becomes Cat. No.100-K09D10.


AC Voltages [V] 24 110 120 230 240 400 480 600
50 Hz D
60 Hz D B VC
50/60 Hz KJ KF KA KN
  

DC Voltages [V] 12 24 110 125 220 250
Standard ZQ ZJ ZD ZS ZA ZT
with Integrated Diode DJ