Bulletin 132/133-C IEC Pump Control Panels
|
Bulletins 132 and 133 IEC Pump Control Panel Starters
- IP32 (Type 3R)
- Bimetallic Class 10 overload relays
- Solid-state overload relays
- Enclosure with extra panel space for mounting accessory devices
- Factory-installed disconnect switch or circuit breaker
- Handle with defeater mechanism
- Service entrance rated
Bulletin 132 and 133 pump control panels are specifically designed for irrigation and similar outdoor pumping applications.
The Bulletin 132 pump control panel includes a Bulletin 194R IEC fusible rotary disconnect switch, a Bulletin 100 IEC contactor, a Bulletin 193 bimetallic overload relay or solid-state overload relays, a HAND-OFF-AUTO selector switch, and a START button. All starters include a normally open auxiliary contact as standard. The Bulletin 133 pump control panels are supplied with a motor circuit protector instead of a fusible disconnect switch. IEC pump control panels include an IP32 (Type 3R) weather-resistant enclosure with a rugged, outdoor finish and brackets for pole or cross-bar mounting. Conduit knockouts are located at the bottom of the enclosure. Padlock provisions are furnished on the door latches and the handle (both the ON and OFF positions).
Your order must include: Cat. No. of the pump control panel, coil voltage code, overload relay suffix code, and, if required, factory-installed modifications suffix code and/or Cat. No. of any accessories.
Standards Compliance and Certifications
Standards Compliance
UL 508
Certifications
cULus Listed (File No. E 125316, Guide NKJH, NKJH7)
Product Selection
Fusible Disconnect Type
| Ratings (AC3, AC4) | Fuse Clip Rating Amperes/UL Class |
IP32 (Type 3R) Sleet Resistant, Outdoor Sheet Metal Enclosure (Hinged Cover) | |||||
| Max Ie [A] |
kW | Hp | |||||
| 3-Phase | 3-Phase | ||||||
| 380/415V | 200V | 230V | 460V | 575V | Cat. No. | ||
| 9 | 4 | 2 | 2 | 5 | 7-1/2 | 30 A/Class CC | 132-C09Mĵ |
| 12 | 5-1/2 | 3 | 3 | 7-1/2 | 10 | 30 A/Class J | 132-C12Mĵ |
| 23 | 11 | 5 | 7-1/2 | 15 | 15 | 30 A/Class J | 132-C23Mĵ |
| 30 | 15 | 7-1/2 | 10 | 20 | 25 | 60 A/Class J | 132-C30Mĵ |
| 43 | 22 | 10 | 15 | 30 | 30 | 60 A/Class J | 132-C43Mĵ |
| 60 | 30 | 15 | 20 | 40 | 50 | 100 A/Class J | 132-C60Mĵ |
| 72 | 37 | 20 | 25 | 50 | 60 | 100 A/Class J | 132-C72Mĵ |
Ä Coil Voltage Code—see Ä Coil Voltage Code
µ Overload Relay Code—see µ Overload Relay Code
Circuit Breaker Type
| Ratings (AC3, AC4) | IP32 (Type 3R) Sleet Resistant, Outdoor Sheet Metal Enclosure (Hinged Cover) | ||||
| Max. Ie [A] |
Hp⋆ | ||||
| 3Æ | |||||
| 200V | 230V | 460V | 575V | Cat. No. | |
| 30 | 1/2 | 1/2 | — | — | 133-C30Mĵ-33 |
| 3/4…1 | 3/4…1 | 1/2…1 | — | 133-C30Mĵ-35 | |
| — | — | — | 1/2…1-1/2 | 133-C30Mĵ-36 | |
| 1-1/2…3 | 1-1/2…3 | 1-1/2…3 | 2…3 | 133-C30Mĵ-38 | |
| 5 | — | — | — | 133-C30Mĵ-39 | |
| 7-1/2 | 5…7-1/2 | 5…7-1/2 | — | 133-C30Mĵ-40 | |
| — | 10 | — | 5…10 | 133-C30Mĵ-41 | |
| — | — | 10 | — | 133-C30Mĵ-42 | |
| — | — | 20 | 15…20 | 133-C30Mĵ-43 | |
| — | — | — | 25 | 133-C30Mĵ-44 | |
| 43 | 7-1/2…10 | 10 | — | — | 133-C43Mĵ-41 |
| — | 15 | — | — | 133-C43Mĵ-42 | |
| — | — | 20…25 | — | 133-C43Mĵ-44 | |
| — | — | 30 | 25…30 | 133-C43Mĵ-45 | |
| 60 | 15 | — | — | — | 133-C60Mĵ-42 |
| — | 15…20 | — | — | 133-C60Mĵ-43 | |
| — | — | 40 | 40 | 133-C60Mĵ-46 | |
| 72 | 15…20 | — | — | — | 133-C72Mĵ-43 |
| — | 20…25 | — | — | 133-C72Mĵ-44 | |
| — | — | 40…50 | — | 133-C72Mĵ-47 | |
| — | — | — | 40…60 | 133-C72Mĵ-48 | |
Ä Coil Voltage Code
The Cat. No. as listed is incomplete. Select a Coil Voltage Code from the table below to complete the Cat. No. Example: Cat. No. 132-C12Mĵ becomes Cat. No. 132-C12MBµ
| Voltage [V] | 208 | 230…240 | 460…480 | 575…600 | |
| Common Control Coil Voltage Suffix Code |
60 Hz | H | A | B | C |
| 120V Separate Control (without transformer) Coil Voltage Suffix Code |
AD | AD | CD | CD | |
µ Overload Relay Code
The Cat. No. as listed is incomplete. Select an overload relay code from Bulletin 193 E1 Plus electronic overload relay for 3-phase applications:
Selectable Trip Class 10, 15, 20, 30, selectable manual/auto reset to complete the Cat. No.
⋆ For horsepower ratings less than those shown, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
When selecting a factory-installed control circuit transformer (see Modifications Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109 with metal enclosures, 100L)), use the Common Control Coil Voltage Code to denote the transformer primary voltage. The starter coil and transformer secondary voltage will both be 120V by default. Example: Cat. No. 132-C09MBµ-6P will have a transformer with a 480V primary/120V secondary and a 120V starter coil. If a starter coil voltage other than 120V is desired, a second Coil Voltage Code must be added to denote the coil/transformer secondary voltage. Example: Cat. No. 132-C09MBJµ-6P will have a transformer with a 480V primary/24V secondary and a 24V starter coil.
Bulletin 100 Line Starter Accessories
For Bulletins 105, 106, 109, 112, and 113
|
Description | For Use With Bulletin No. | Enclosure Type | Cat. No. | ||
| Red "ON" Pilot Light⋆ Full Voltage Type |
120V | All | Metal Lift-off, Metal Hinged, and Molded Plastic | | 198-PL21R | |
| 208V | | 198-PL25R | ||||
| 240V | | 198-PL22R | ||||
| 24V | 103H | Metal Hinged | | 198-PL26R | ||
| 120V | | 198-PL27R | ||||
| 240V | | 198-PL28R | ||||
|
Green Pilot Light⋆ Full Voltage Type |
24V | All | Metal Lift-off, Metal Hinged, and Molded Plastic | | 198-PL26G |
| 120V | All | | 198-PL21G | |||
| 240V | All | | 198-PL22G | |||
|
Dual "ON" Pilot Light⋆ Forward — Red Reverse — White Full Voltage Type |
120V | 105, 106 | Metal Hinged | 198-PL21RW | |
| 240V | 198-PL22RW | |||||
|
Pilot Device Mounting Bracket (required when mounting pilot devices in metal lift-off enclosures) |
105, 109 | Metal Lift-off | 198-BR1 | ||
|
Control Circuit Fuse Block For Class CC rejection type fuses (fuses not included) |
All | Metal Lift-off and Metal Hinged | 1491-R162 | ||
|
Grounding Bushing Adapts to 1/2 in. N.P.T., PG 16.5 & BS20 mm threads |
109 | Molded Plastic | 198-GR1 | ||
|
Single Pole N.O. Auxiliary Contact for Disconnect Switch | 106, 112 | Metal Hinged | § | 195-GA10 | |
|
Closing Button For 22.5mm Round Panel Hole |
All | All | 198-N1 | ||
|
"OFF-ON" Selector Switch 2-Position Maintained |
All | Metal Lift-off and Metal Hinged | | 198-MT3 | |
| ⋆ Does not include legend plate. See Two-Color Molded Legend Caps — Non-Illuminated Push Buttons for Bulletin 800F Legend Plate. Legend Plates for use on metal-hinged enclosures only. | ||||||
| Requires mounting bracket Cat. No. 198-BR1 when using metal lift-off enclosures. | ||||||
| § An auxiliary contact adaptor, Cat. No. 194R-AA, is required when installing auxiliary contact, Cat. No. 195-GA10. | ||||||
| ♣ 3 required for disconnect switch. | ||||||
For Bulletins 105, 106, 109, 112, and 113
Modifications
Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 109 with metal enclosures, 100L)
Listed on this and the following pages are factory-installed modifications and special features which are available for the low voltage (600V maximum) starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product Cat. No. Example: Cat. No. 109-C09ADA1E-1
| Description of Modification | Suffix Code | Enclosure Design | C09/CA | C12/CB | C16/CC | 100L-C20 | C23/CD | C30 | C37 | C43 | C60 | C72 | C85 |
| START-STOP Push Button | 1 | Metal Lift-off | A | A | A | NA | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | NA | A | A | A | A | A | A | A | ||
| ON-OFF Push Button | 1E | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| HAND-OFF-AUTO Selector Switch | 3 | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| OFF-ON Selector Switch | 3E | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| RUN-Red Pilot Light⋆ | 4R | Plastic Lift-off | A | A | A | NA | A | A | A | A | A | A | A |
| RUN-Green Pilot Light⋆ | 4G | A | A | A | NA | A | A | A | A | A | A | A | |
| RUN-Yellow Pilot Light⋆ | 4Y | A | A | A | NA | A | A | A | A | A | A | A | |
| Red LED Pilot Light (120V) | 4R1 | Plastic Lift-off | A | A | A | NA | A | NA | NA | NA | NA | NA | NA |
| Red LED Pilot Light (240V) | 4R2 | Plastic Lift-off | A | A | A | NA | A | NA | NA | NA | NA | NA | NA |
| Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) | 6P | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| External Reset | 7 | Plastic Lift-off | A | A | A | NA | A | NA | NA | NA | NA | NA | NA |
| Metal Lift-off | A | A | A | NA | A | A | A | A | A | A | A | ||
| Metal Hinged | A | A | A | NA | A | A | A | A | A | A | A | ||
| Control Circuit Fuse Block 2 Fuses Provided | 22 | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on Contactor (100L only) | 90 | Metal Lift-off | NA | NA | NA | A | NA | NA | NA | NA | NA | NA | NA |
| Metal Hinged | NA | NA | NA | A | NA | NA | NA | NA | NA | NA | NA | ||
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on Contactor | 901 | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| Additional 1 N.O. 1 N.C. (Front Mount) Auxiliary Contact on Contactor | 901T | Metal Lift-off | A | A | A | A | A | A | A | A | A | A | A |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | A | ||
| ⋆ With Bulletin 800F Integrated LED Module. Pilot light is available for control voltages of 240Vor less. If applicable, seelct a transformer. For starters with molded plastic lift-off enclosures, the voltage of the LED module must equal the starter's coil voltage. | |||||||||||||
Non-Reversing Circuit Breaker Combination Starters (Bulletin 113)
| Description of Modification | Suffix Code |
Enclosure Design |
C09 | C12 | C16 | C23 | C30 | C37 | C43 | C60 | C72 | C85 |
| START-STOP Push Button | 1 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| HAND-OFF-AUTO | 3 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Red Pilot Light§ | 4R | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) | 6P | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| External Reset | 7 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Control Circuit Fuse Block 2 Fuses Provided | 22 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Additional 1 N.O. - 1 N.C. (Side Mount) Auxiliary Contact on Contactor | 901 | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| Additional 1 N.O. - 1 N.C. (Front Mount) Auxiliary Contact on Contactor | 901T | ALL | NA | NA | NA | NA | A | NA | A | A | A | NA |
| A=Available Option | ||||||||||||
| NA=Not Available | ||||||||||||
| § Transformer Type. | ||||||||||||
| When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code. | ||||||||||||
Full Voltage Reversing and Multi-Speed Starters (Bulletin 105 with metal enclosures)
| Description of Modification | Suffix Code |
Enclosure Design | C09 | C12 | C16 | C23 | C30 | C37 | C43 | C60 | C72 | C85 |
| FOR-REV-STOP Push Buttons (105 Only) | 1 | Metal Lift-off | A | A | A | A | A | A | A | A | A | NA |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | ||
| FOR-OFF-REV Selector Switch (105 Only) | 3 | Metal Lift-off | A | A | A | A | A | A | A | A | A | NA |
| Metal Hinged | A | A | A | A | A | A | A | A | A | A | ||
| Red FOR/ White REV Pilot Lights⋆ (105 Only) | 4RW | Metal Hinged | A | A | A | A | A | A | A | A | A | A |
| A | A | A | A | A | A | A | A | A | A | |||
| Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) | 6P | ALL | A | A | A | A | A | A | A | A | A | A |
| 1 External Reset (105 Only) | 7 | ALL | A | A | A | A | A | A | A | A | A | A |
| Control Circuit Fuse Block 2 Fuses Provided | 22 | ALL | A | A | A | A | A | A | A | A | A | A |
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on Each Contactor | 901 | ALL | A | A | A | A | A | A | A | A | A | A |
| Additional 1 N.O. 1 N.C. (Front Mount) Auxiliary Contact on Each Contactor | 901T | ALL | A | A | A | A | A | A | A | A | A | A |
Reversing and Non-Reversing Fusible Combination Starters (Bulletins 106, 112)
| Description of Modification | Suffix Code |
Enclosure Design |
C09 | C12 | C16 | C23 | C30 | C37 | C43 | C60 | C72 | C85 |
| START-STOP Push Button (112 Only) | 1 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| FOR-REV-STOP Push Buttons (106 Only) | 1 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| HAND-OFF-AUTO Selector Switch (112 Only) | 3 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| FOR-REV-STOP Selector Switch (106 Only) | 3 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Red Pilot Light⋆ (112 Only) | 4R | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Red FOR/ White REV Pilot Lights⋆ (106 Only) | 4RW | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) | 6P | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| External Reset | 7 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Fuse Cover For Disconnect Switch | 8 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Control Circuit Fuse Block 2 Fuses Provided | 22 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| N.O. Auxiliary Contact On Disconnect Switch | 98 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on Contactor (112 Only) | 901 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Additional 1 N.O. 1 N.C. (Side Mount) Auxiliary Contact on each Contactor (106 Only) | 901 | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Additional 1 N.O. 1 N.C. (Front Mount) Auxiliary Contact on Contactor (112 Only) | 901T | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| Additional 1 N.O. 1 N.C. (Front Mount) Auxiliary Contact on each Contactor (106 Only) | 901T | ALL | A | A | NA | A | A | NA | A | A | A | NA |
| A=Available Option | ||||||||||||
| NA=Not Available | ||||||||||||
| ⋆ Transformer Type. | ||||||||||||
| When ordering in Canada, use suffix 6. Primary fusing is not required by the Canadian Electrical Code. | ||||||||||||
Bul. 100 Line Starters Approximate Dimensions
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 109 Plastic Lift-Off Enclosure
|
Cat. Nos. 198E-C2S4, -C0S4R, and -C0C4R Plastic Enclosures
Approximate dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes.
|
|
Approximate dimensions are shown in millimeters (inches). Dimensions are not to be used for manufacturing purposes.
|
Bulletin 109 Metal Lift-Off Enclosures Type 1 (IP42)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F |
| IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (Without Transformer) | ||||||
| C09…C23 | 315 (12-27/64) |
188 (7-23/64) |
203 (8) |
270 (10-5/8) |
140 (5-33/64) |
24 (15/16) |
| C30…C43 | ||||||
| C60…C72 | 305 (12) |
178 (7) |
203 (8) |
270 (10-5/8) |
140 (5-33/64) |
24 (15/16) |
| C85 | 585 (23-1/32) |
257 (10-7/64) |
203 (8) |
540 (21-17/64) |
210 (8-17/64) |
23.5 (59/64) |
| IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 109 (With Transformer) | ||||||
| C09…C23 | 305 (12) |
178 (7) |
203 (8) |
245 (9-41/64) |
140 (5-33/64) |
24 (15/16) |
| C30…C43 | 290 (11-27/64) |
270 (10-5/8) |
152 (5-31/32) |
245 (9-41/64) |
225 (8-55/64) |
22.5 (57/64) |
| C60…C72 | 315 (12-27/64) |
325 (12-51/64) |
203 (8) |
270 (10-5/8) |
280 (11-1/64) |
22.5 (57/64) |
| C85 | 585 (23-1/32) |
257 (10-7/64) |
203 (8) |
540 (21-17/64) |
210 (8-17/64) |
23.5 (59/64) |
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Bulletins 105 and 120E Metal Lift-Off Enclosures Type 1 (IP42)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F | G (dia.) |
| IP42 (Type 1) General Purpose Metal Lift-off Enclosure for Bulletin 105 and 120E (Without Transformer) | |||||||
| C09…C23 | 220 (8-21/32) |
235 (9-1/4) |
152 (5-31/32) |
175 (6-57/64) |
190 (7-31/64) |
22.5 (57/64) |
— |
| C30…C43 | 290 (11-27/64) |
270 (10-5/8) |
152 (5-31/32) |
245 (9-41/32) |
225 (8-55/64) |
22.5 (57/64) |
— |
| C60…C72 | 315 (12-27/64) |
325 (12-51/64) |
203 (8) |
270 (10-5/8) |
280 (11-1/64) |
22.5 (57/64) |
— |
| C85 | 610 (24) |
406 (16) |
230 (9-1/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
11 (7-16) |
| IP42 (Type 1) General Purpose Metal Lift-Off Enclosure for Bulletin 105 and 120E (With Transformer) | |||||||
| C09…C23 | 290 (11-27/64) |
270 (10-5/8) |
152 (5-31/32) |
245 (9-41/64) |
225 (8-55/64) |
22.5 (57/64) |
— |
| C30…C43 | 315 (12-27/64) |
325 (12-51/64) |
203 (8) |
270 (10-5/8) |
280 (11-1/64) |
22.5 (57/64) |
— |
Bulletins 106, 112, and 113 Metal Hinged Enclosures Type 1 (IP42), Type 3/4/12 (IP66)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F | G (dia.) |
| IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 106 (With and Without Transformer) | |||||||
| C30…C43 | 350 (13-25/32) |
400 (15-3/4) |
200 (7-7/8) |
315 (12-13/32) |
178 (7) |
62 (2-7/16) |
6.4 (1/4) |
| C60…C72 | 610 (24) |
406 (16) |
224 (8-13/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
12.7 (1/2) |
| IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 112 (With and Without Transformer) | |||||||
| C09…C23 | 350 (13-25/32) |
200 (7-7/8) |
200 (7-7/8) |
315 (12-13/32) |
76 (3) |
62 (2-7/16) |
6.4 (1/4) |
| C30…C43 | 350 (13-25/32) |
400 (15-3/4) |
200 (7-7/8) |
315 (12-13/32) |
178 (7) |
111 (4-3/8) |
6.4 (1/4) |
| C60…C72 | 610 (24) |
406 (16) |
224 (8-13/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
12.7 (1/2) |
| IP42 (Type 1) and IP66 (Type 3/4/12) General Purpose Metal Hinged Enclosure for Bulletin 113 (With and Without Transformer) | |||||||
| C30…C72 | 610 (24) |
406 (16) |
224 (8-13/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
12.7 (1/2) |
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Bulletin 109 Metal Hinged Enclosures Type 3/4/12 (IP66)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F | G (dia.) |
| IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (Without Transformer) | |||||||
| C09…C43 | 300 (11-13/16) |
200 (7-7/8) |
160 (6-5/16) |
265 (10-7/16) |
76 (3) |
62 (2-7/16) |
5.5 (7/32) |
| C60…C72 | 350 (13/25/32) |
200 (7-7/8) |
210 (8-9/32) |
315 (12-13/32) |
76 (3) |
62 (2-7/16) |
5.5 (7/32) |
| C85 | 762 (30) |
305 (12) |
276 (10-7/8) |
724 (28-1/2) |
267 (10-1/2) |
19 (3/4) |
11 (7/16) |
| IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletin 109 (With Transformer) | |||||||
| C09…C23 | 300 (11-13/16) |
200 (7-7/8) |
160 (6-5/16) |
265 (10-7/16) |
76 (3) |
62 (2-7/16) |
5.5 (7/32) |
| C30…C43 | 300 (11-13/16) |
300 (11-13/16) |
160 (6-5/16) |
236 (9-5/16) |
178 (7) |
61 (2-13/32) |
5.5 (7/32) |
| C60…C72 | 350 (13-25/32) |
400 (15-3/4) |
210 (8-9/32) |
315 (12-13/32) |
178 (7) |
111 (4-3/8) |
5.5 (7/32) |
| C85 | 610 (24) |
406 (16) |
230 (9-1/16) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
11 (7/16) |
Bulletins 105 and 120E Metal Hinged Enclosures Type 3/4/12 (IP66)
|
| Contactor Size | A Height | B Width | C Depth | D | E (Mtg.) | F | G (dia.) |
| IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletins 105 and 120E (Without Transformer) | |||||||
| C09…C23 | 250 (9-13/16) |
250 (9-13/16) |
160 (6-5/16) |
186 (7-5/16) |
76 (3) |
87 (3-13/32) |
5.5 (7/32) |
| C30…C43 | 300 (11-13/16) |
300 (11-13/16) |
160 (6-5/16) |
236 (9-5/16) |
178 (7) |
61 (2-13/32) |
5.5 (7/32) |
| C60…C72 | 350 (13/25/32) |
400 (15-3/4) |
210 (8-9/32) |
315 (12-13/32) |
178 (7) |
111 (4-3/8) |
5.5 (7/32) |
| C85 | 610 (24) |
406 (16) |
230 (9-1/06) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
11 (7/16) |
| IP66 (Type 3/4/12) Metal Hinged Enclosure for Bulletins 105 and 120E (With Transformer) | |||||||
| C09…C23 | 300 (11-13/16) |
300 (11-13/16) |
160 (6-5/16) |
236 (9-5/16) |
178 (7) |
61 (2-13/32) |
5.5 (7/32) |
| C30…C43 | 350 (13-25/32) |
400 (15-3/4) |
210 (8-9/32) |
315 (12-13/32) |
178 (7) |
111 (4-3/8) |
5.5 (7/32) |
| C60…C72 | 610 (24) |
406 (16) |
230 (9-1/06) |
572 (22-1/2) |
368 (14-1/2) |
19 (3/4) |
11 (7/16) |
| C85 | 762 (30) |
610 (24) |
281 (11-1/16) |
724 (28-1/2) |
572 (22-1/2) |
19 (3/4) |
11 (7/16) |
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Bulletins 132 and 133 Metal Hinged Enclosures with Extra Space Type 3R (IP32)
|
| Contactor Size | A Height | B Width | C Depth | D | E | F | G | H | J | K |
| IP 32 (Type 3R) Rainproof Metal Hinged Enclosure for Bulletins 132 and 133 (With and Without Transformer) | ||||||||||
| C09…C43 | 584 (23) |
320 (12-19/32) |
187 (7-5/16) |
711 (28) |
105 (4-1/8) |
108 (4-1/4) |
679 (26-3/4) |
667 (26-1/4) |
105 (4-1/8) |
105 (4-1/8) |
| C60…C72 | 864 (34) |
447 (17-19/32) |
238 (9-5/16) |
991 (39) |
105 (4-1/8) |
171 (6-3/4) |
959 (37-3/4) |
946 (37-1/4) |
105 (4-1/8) |
169 (6-12/32) |
| B110 | 1067 (42) |
762 (30) |
305 (12) |
1118 (44) |
686 (27) |
38 (1-1/2) |
1092 (43) |
1092 (43) |
— | — |
| B180…B250 | 1219 (48) |
914 (36) |
305 (12) |
1270 (50) |
686 (27) |
114 (4-1/2) |
1245 (49) |
1245 (49) |
— | — |