Catalogs > Industrial Controls Catalog > Motor Control, IEC > Enclosed Starters > Bulletin 103H/107H/140M Enclosed Combination Starters and Motor Protectors

Bulletin 103H/107H/140M Enclosed Combination Starters and Motor Protectors

Introduction Features Standards Compliance and Certifications Product Selection Modifications Wiring Diagram Enclosure Dimensions
Modifications

Bulletin 103H/107H Factory Installed Modifications

Note:For modifications add (option code ♣ ) for desired features to cat. no.

♣ Add desired option codes. Example: 103H-AND2-CA16X-KY


Coil Options
JE⋆  Electronic Interfaces (100-C)
R⋆  Surge Suppressor RC (100-C)
V⋆  Surge Suppressor Varistor (100-C)
D⋆  Surge Suppressor Diode (100-C)
Additional Contactor Auxiliaries (Side Mount)
S01⋆  1 N.C.
S10⋆  1 N.O.
S11⋆  1 N.O. + 1 N.C.
S20⋆  2 N.O.
Additional 140M Auxiliaries (Side Mount)
A02 2 N.C.
A20 2 N.O.
A11 1 N.O. + 1 N.C.
Additional 140M Trip Contacts (Side Mount)
R00 1 N.O. Thermal-Mag + 1 N.O. Mag Only
R01 1 N.O. Thermal-Mag + 1 N.C. Mag Only
R10 1 N.C. Thermal-Mag + 1 N.O. Mag Only
R11 1 N.C. Thermal-Mag + 1 N.C. Mag Only
M11 1 N.O. Mag Only + 1 N.C. Mag Only
Control Options
1 Push Button — 103H Start-Stop / 107H For-Rev-Stop
1M Multifunction Push Button — 103H Start-Stop / 107H For-Rev-Stop
14RM Multifunction Push Button — 103H Start-Stop-Pilot Light
3 Selector Switch — 103H Hand-Off-Auto / 107H For-Off-Rev
4R Pilot Light (red, ON) (103H only)
4RW Pilot Light (red—FOR, White — REV) (107H only)
6P‡ §  Control Transformer§  (not available with enclosure size A)
KY Bulletin 140M External Handle — Red/Yellow
  

⋆ 107H - One per contactor, for a total of two per option code.
‡ Starters in enclosure size "A" will change to enclosure size "B" when a control transformer is factory installed.
§ Auxiliary contacy option "A20" is required when seelcting this control transformer.


140M Factory Installed Modifications (Enclosed)

Note:For modifications add (option code ♣ ) for desired features to cat. no.

♣ Add desired option codes. Example: 140M-F-CA16X-UVB


Modifications
UVÄ Undervoltage Trip
SNÄ Shunt Trip
Additional 140M Auxiliaries (Side Mount)
A02 2 N.C.
A20 2 N.O.
A11 1 N.O. + 1 N.C.
Additional 140M Trip Contacts (Side Mount)
R00 1 N.O. Thermal-Mag + 1 N.O. Mag Only
R01 1 N.O. Thermal-Mag + 1 N.C. Mag Only
R10 1 N.C. Thermal-Mag + 1 N.O. Mag Only
R11 1 N.C. Thermal-Mag + 1 N.C. Mag Only
M11 1 N.O. Mag Only + 1 N.C. Mag Only
  

Line and Coil Voltage Codes

µ Line Voltage Codes

The Cat. No. as listed is incomplete. Select a line voltage code from the table below to complete the Cat. No.
Example: 208V 60 Hz: Cat. No. 103H-AFµÄ2-CA16X becomes Cat. No. 103H-AFHÄ2-CA16X.


Line Voltages [V] 208 230 240 380 400 415 480 600
60 Hz H A B C
50 Hz F N KN G
  

Ä Coil Voltage Codes

The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No.
Example: 120V 60 Hz: Cat. No. 103H-AFHÄ-CA16X becomes Cat. No. 103H-AFHD2-CA16X.


Standard Coil
Voltages [V]
24 110 120 208 220…230 240…260 277 380…400 415 480 600
AC, 50 Hz K D P F N B
AC, 60 Hz J D H A T B C
AC, 50/60 Hz KJ KD
  

Standard Coil
Voltages [V]
24
DC Standard ZJ
With integrated diode KJ